HomeMy WebLinkAbout1st floor layoutrequired for cantilever.BCI joist blocking
23/32" min. plywood/OSB
into each flange.
Nail with 8d nails
or rimboard closure.
®
F05
See Boise literature for
Nail Boise Rimboard
nail into each flange.
to BCI joist with 8d
Bo ise R
i
mboa
r
d
vertical load capacity.
®
F07
vertical load capacity.See Boise literature forF07-A
of Boise joist & rimboard for
total vertical load capacity.
Sum vertical load capacities
F07-C
(stacked over wall below)
Load bearing wall above
See Boise literature for
vertical load capacity.
BCI Joist Blocking®
F06
above to bearing below.
Solid block all posts from
F08
required for cantilever.BCI / AJS joist blocking
LVL Rim
8d nails @ 6" o.c.
®
Inverted hanger
F05-A
against top flange with 1/8"
Boise Rim Board
Web Stiffener for 14" & 16" joists.
5 - 3" (10d) nails
gap between bottom flange
1/8"
Stiffeners are required on both sides
- Hangers with side nailing.
- Any hanger with sides not
containing the top flange
with 3 - 3" (10d)
- Web stiffener nailed
of the joist.
11 7/8" joists, and
nails for 9 1/2" and
of the web when :
Point Load from above > 1500 lbs. (Factored)
Install web stiffeners tight
For Point Load from above:
F16-E
2x block
(stacked over wall below)
1/16"
Load bearing wall aboveF09
10-10d nails.
Nail with
Filler block.
Install tight to top flange.
mount hanger load exceeds 250 lbs.
Backer block required where top
Backer block (12" wide min.)
Nail with 10- 10d nails.
Install tight to top flange.
Joist hanger
F10
(see literature)Filler Block
Contact Boise EWP Engineering for specific conditions.
Connection valid for all applications.
Nailing 12" OCWeb-Filler
Connection
Double BCI Joist®F58
Start Framing Here
16" O.C Spacing
Products
PlotIDLengthProduct Plies Net QtyFab Type
FJ1 44' 0" 16" AJS® 24 1 1 MFD
FJ2 40' 0" 16" AJS® 24 1 1 MFD
FJ3 38' 0" 16" AJS® 24 1 2 MFD
FJ4 36' 0" 16" AJS® 24 1 10 MFD
FJ5 34' 0" 16" AJS® 24 1 2 MFD
FJ6 32' 0" 16" AJS® 24 1 7 MFD
FJ7 30' 0" 16" AJS® 24 1 1 MFD
FJ8 28' 0" 16" AJS® 24 1 3 MFD
FJ9-2 28' 0" 16" AJS® 24 2 2 MFD
FJ10 26' 0" 16" AJS® 24 1 13 MFD
FJ11-2 26' 0" 16" AJS® 24 2 2 MFD
FJ12 24' 0" 16" AJS® 24 1 8 MFD
FJ13 20' 0" 16" AJS® 24 1 27 MFD
FJ14-2 20' 0" 16" AJS® 24 2 6 MFD
FJ15-2 18' 0" 16" AJS® 24 2 2 MFD
FJ16 16' 0" 16" AJS® 24 1 8 MFD
FJ17 14' 0" 16" AJS® 24 1 1 MFD
FJ18 12' 0" 16" AJS® 24 1 1 MFD
FJ19 8' 0" 16" AJS® 24 1 3 MFD
FJ20 4' 0" 16" AJS® 24 1 1 MFD
FJ21 2' 0" 16" AJS® 24 1 1 MFD
BM-3 10' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 3 3 FF
BM-4 10' 0" 1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 3 3 FF
BM-61 28' 0" 1-3/4" x 16" VERSA-LAM® 2.0 3100 SP 2 2 FF
BM-60 12' 0" 1-3/4" x 16" VERSA-LAM® 2.0 3100 SP 4 4 FF
BM-58 6' 0" 1-3/4" x 16" VERSA-LAM® 2.0 3100 SP 1 1 FF
BM-59 6' 0" 1-3/4" x 16" VERSA-LAM® 2.0 3100 SP 2 2 FF
BM-2 20' 0" 1-3/4" x 18" VERSA-LAM® 2.0 3100 SP 4 4 FF
BM-1 14' 0" 1-3/4" x 18" VERSA-LAM® 2.0 3100 SP 4 4 FF
Ca1 12' 0" 1" x 16" BC RIM BOARD OSB 1 26 FF
Bk1 2' 0" 16" AJS® 24 1 18 FF
Bk2 2' 0" 16" AJS® 24 1 6 MFD
Connector Summary
PlotIDQtyManufProduct Flange
H1 1 USP THDH7214 None
USEDWALL FOR BEARNG.
PLEASE VERIFY FOOTING
FRAMING BY
OTHER. PLEASE
VERIFY
BEAM BM - 1 FAILEDDUETO
BEARING LENGTH. IT
REQUIRES 6" BEARING
LENGTH. PLEASE VERIFY
ADDFLUSHEDBEAM TO
SUPPORT POINT LOAD
ABOVE. PLEASE VERIFY
PRELIMINARY- NOT FOR CONSTRUCTION - VERIFY
STAIRCASE FRAMING WITH BUILDERPRIOR TO SHIPMENT BM-1BM-2
BM-3 BM-4
B
M
-
5
8
B
M
-
5
9
BM-60BM-61Ca1Ca1Ca1 C a1
Ca1 Ca1
Ca1Ca1Ca1Ca1
Ca1Ca1Ca1 Ca1 Ca1Ca1Ca1Ca1
Ca1Ca1Ca1
Ca1
Ca
1Ca1Ca
1Ca1Ca1Ca1 Ca1
Ca1 Ca1
Ca1
Ca1Ca1 Ca1
Ca1
Ca1
Ca1
Ca1
Ca1
Ca1
Ca1Ca1 Bk2 Ca1Ca1Ca1Ca1Ca1Ca1Ca1Ca1Ca1
C
a
1
C
a1
Ca1
Ca1Ca1Ca1Ca1Ca1
Ca1
Ca 1 Ca1
Ca
1
C
a
1
Ca
1
Ca1Ca1Ca1Ca1Ca1Ca1
Ca1Ca1 FJ7FJ15-2 FJ17FJ6FJ6FJ13 FJ9-2FJ21 FJ10 FJ3FJ3FJ2FJ18 FJ1FJ14-2FJ10FJ10FJ10FJ10FJ20 FJ11-2FJ13FJ13FJ6
FJ6
FJ5
FJ16
FJ16
FJ8
FJ12FJ12FJ12
FJ13FJ13
FJ10
FJ4FJ4
FJ19
FJ13
FJ14-2
Bk1
Bk1
Bk2
Bk2
Bk2
U
n
d
e
s
i
g
n
e
d
U
n
d
e
s
i
g
n
e
d
H1
1X1X
1' 6 1/4" 1' 1 3/4"By:
Date:
Scale:1/4"=1'
BC FRAMER
RIMBOARDISNOT TO BE CUT. IF A PIECE OF
RIMBOARDENDSBETWEEN TWO JOISTS, BUTT
THE NEXT PIECE UP TO IT.
Boise I-Joist can be offset up to 3" to avoid vertical plumbing.
Joist
3" max
C L Joist
3" max
C L
OJ-AFASTENALL2-PLY LVL'S UP TO 11-7/8" WITH 2 ROWS OF 16DSINKER NAILS @12" OC STAGGERED
FASTEN ALL 2-PLY LVL'S 14"-18" 3 ROWS OF 16DSINKER NAILS @12" OC STAGGERED
FASTEN ALL 2-PLY LVL'S 20"-24" WITH 2 ROWS OF 16DSINKER NAILS @12" OC STAGGERED
FASTEN ALL 3-PLY LVL'S UP TO 11-7/8" WITH 2 ROWS OF 16DSINKER NAILS @12" OC STAGGERED, FROM BOTH SIDES
FASTEN ALL 3-PLY LVL'S 14"-18" 3 ROWS OF 16DSINKER NAILS @12" OC STAGGERED, FROM BOTH SIDES
FASTEN ALL 3-PLY LVL'S 20"-24" WITH 2 ROWS OF 16DSINKER NAILS @12" OC STAGGERED, FROM BOTH SIDES
FASTEN ALL 4-PLY LVL'S UP TO 18" WITH 2 ROWS OF 1/2" STAGGEREDTHROUGH BOLTS @12" OC STAGGERED
FASTEN ALL 4-PLY LVL'S 20"-24" WITH 3 ROWS OF 1/2" STAGGEREDTHROUGH BOLTS @12" OC STAGGERED
ALL 1/2" BOLTS , CAN BE REPLACEDWITH SDW22634 SCREWS
UNLESS OTHERWISE NOTEDON THE LAYOUT FOR ALL CONNECTION DETAILS
Revision Date:
Revision Date:1ST FLR FRAMINGCarter Lumber, Franklin INSigma - PandaSigma10/01/20