Loading...
HomeMy WebLinkAboutTRUEBLOODCARMEL_FULLPERMITSET_090920_tenant signedTVTVFEELNELNELNELNELNELN DOCUMENT APPROVAL TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS. _________________________________________________________________ __________________ TENANT/CLIENT COMPANY NAME DATE _________________________________________ ___________________________________________ TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN-OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT. THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. COVER SHEET AND GENERAL NOTES T111 DESCRIPTIONDATE ISSUE 06.12.20 REVIEW SET 06.29.20 UPDATED SET 09.09.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 07.29.20 EH PLAN UPDATE 08.12.20 EH CLG UPDATES THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032EHEH 2019.288 1ST FLOOR T111 COVER SHEET AND GENERAL PROJECT NOTES L100 LIFE SAFETY PLAN A111 DECONSTRUCTION PLAN / ARCHITECTURAL FLOOR PLAN A121 ELECTRICAL PLAN / REFLECTED CEILING PLAN A131 FINISH PLAN A141 RESTROOM DETAILS A211 DOOR SCHEDULE / INTERIOR DETAILS M101 ENGINEERED MECHANICAL PLAN E100 ENGINEERED ELECTRICAL PLAN P100 ENGINEERED PLUMBING PLAN P200 ENGINEERED PLUMBING PLAN P300 ENGINEERED PLUMBING PLAN INDEX OF DRAWINGS VICINITY MAP NOT TO SCALE NOT TO SCALE KEY PLAN - 1ST FLOOR N GENERAL PROJECT NOTES 1. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 2. DESIGN BUILD FIRE PROTECTION SYSTEM: FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC. IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 3. FIRE PROTECTION SYSTEM CODE COMPLIANCE: THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. 4. FIRE PROTECTION DESIGN DRAWINGS: THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. SPRINKLER HEADS: PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK. FIRE PROTECTION NOTES 1. STATE BUILDING COMPLIANCE FOR FINISHES: ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. 2. GYPSUM ASSOCIATION CONFORMITY: FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS, CORNER BEADS, ETC.). PROVIDE NEW CEMENT BACKER BOARD AS A SUBSTRATE FOR NEW WALL TILE PER MANUFACTURER'S RECOMMENDATIONS. 3. COVER PLATES: REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE PAINTING AND REINSTALL AFTERWARD. CONTRACTOR TO CONFIRM DESIRED COLOR PRIOR TO PURCHASING NEW. 4. PAINTING: ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH COATS. 5. FLOORING TRANSITION STRIPS: FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS AS NOTED ON FINISH PLAN UNLESS NOTED OTHERWISE (I.E. WHERE VCT MEETS CARPET). 6. DELIVERY OF COMPREHENSIVE WORK PRODUCT: WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. 7. WALL DEMOLITION: REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. 8. PHONE BOARDS: WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. 9. MILLWORK SAMPLES: SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 10. INTERIOR ELEVATION DETAILS: REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH INFORMATION. 11. PAINT & ADHESIVE VOC'S: ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE ZERO VOC CONTENT. 12. ADHESIVE MANUFACTURER RECOMMENDATIONS: ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT MANUFACTURER. FINISH NOTES 1. CASEWORK/MILLORK: CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE PROVIDED UNDER THE GENERAL CONTRACT. 2. AWI COMPLIANCE: UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK. 3. MILLWORK SHOP DRAWINGS: FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION. 4. MILLWORK FIELD VERIFICATION: WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON PLANS AGAINST DIMENSIONS OF AS-BUILT CONDITIONS IN FIELD. REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS. 5. DRAWING REVIEW AND DISCREPANCIES: VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION DRAWINGS WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. 6. MILLWORK REQUIREMENTS: REFER TO MILLWORK SECTIONS & ELEVATIONS . UNLESS OTHERWISE SHOWN, PLASTIC LAMINATE CLAD COUNTERTOPS WITH 4" BACKSPLASH WHERE INDICATED, BACKSPLASH TO BE FIELD APPLIED. REFER TO MILLWORK SECTIONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS (CUSTOM PLASTIC LAMINATE OR PRE-MANUFACTURED STOCK CABINETRY). EDGES OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED OTHERWISE. 7. MILLWORK WALL BLOCKING: PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED. MILL/CASEWORK NOTES 1. DECONSTRUCTION DEFINITION: CAREFULLY DISMANTLE SPACES WITH THE GOAL OF MAXIMIZING THE REUSE POTENTIAL OF ITS COMPONENTS. 2. RECYCLING: GENERAL CONTRACTOR IS RESPONSIBLE FOR RECYCLING OF ALL CARPET AND METALS AT A MINIMUM, AND COORDINATING THE APPROPRIATE HAULING CONTAINERS WITH THE WASTE MANAGEMENT SUB-CONTRACTOR AND KRUSE CARPET RECYCLING. REFER TO DECONSTRUCTION D111 SHEET FOR SPECIFIC INSTRUCTIONS. 3. EXISTING STRUCTURAL ELEMENTS OF BUILDING: NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED, DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR OTHERWISE LOAD-BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM. 4. EQUIPMENT, FIXTURE, FINISH RE-USE: WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 5. DECONSTRUCTION PLANS: REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DECONSTRUCTION PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DECONSTRUCTION. 6. FIELD VERIFICATION OF EXISTING CONDITIONS: REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING FINISHES TO REMAIN. 7. PROTECTION OF BUILDING ELEMENTS TO REMAIN: USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE OWNER'S USE IN THE PROJECT. 8. REMOVAL OF ABANDONED CABLING & WIRING: PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION) REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS, AND PLTC CABLES. REFER TO SECTION 300.21. ANY SUCH CABLE OR WIRING SHOULD BE PULLED AND REMOVED BACK TO THEIR MAIN SOURCES ON THE FLOOR (I.E. ELECTRICAL PANELS, PHONE BOARDS, ETC.) 9. PROTECTION OF ABANDONED/TERMINATED BUILDING SYSTEM ELEMENTS: WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING, MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN "AS-BUILT" SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 10. HAZARDOUS MATERIALS: GENERAL CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ANY AND ALL ITEMS THAT MAY CONTAIN HAZARDOUS OR HARMFUL MATERIALS. ALL IDENTIFIED ITEMS MUST BE PROPERLY DISPOSED OF PER EPA AND INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT RULES AND REGULATIONS. DECONSTRUCTION NOTES 1. BUILDING CODE COMPLIANCE: ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE AND ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK. ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. 2. CONTRACTOR SITE VISITS: CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. 3. CONTRACTOR FIELD VERIFICATION: FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS; NOTED DIMENSIONS TAKE PRECEDENCE. VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCIES THROUGH THE GENERAL CONTRACTOR TO SCHOTT DESIGN, INC. 4. GENERAL CONTRACTOR COORDINATION WITH OWNER: THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON-SITE ACTIVITIES SUCH AS, BUT NOT LIMITED TO: WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. 5. PROJECT MATERIAL LEAD TIMES: FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. 6. MATERIAL SUBSTITUTIONS: SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION. 7. SAFE WORK AREA: SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, BE IN CHARGE OF, OR BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES. 8. GENERAL CONTRACTOR CLEANUP PROCEDURES: THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT. 9. STAGING/ PARKING/ DUMPSTERS/ RESTROOMS: THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING RESTROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS. 10. DUST CONTROL: THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS @ 24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH SIDE. 11. PROJECT INSTALLATION CONFLICTS: CONTACT THE DESIGNER IMMEDIATELY IF CONFLICTS ARE DISCOVERED IN THE FIELD BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN). 12. SCHOTT DESIGN HAZARDOUS MATERIALS WAIVER: SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE. 13. WOOD BLOCKING IN WALLS: PROVIDE FIRE-TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC. 14. SHOP DRAWINGS: SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 15. PROJECT APPROVALS: ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER. 16. CHANGE ORDERS: REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT. 17. FURNITURE AND EQUIPMENT EXCLUSIONS: FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED. 18. WALL PATCHING: PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. 19. CONSTRUCTION CLEANING: EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCES WORK & DO NOT LEAK. 20. O & M MATERIALS: PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. 21. PLAN DIMENSIONS: ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 22. WINDOW BLINDS: CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING STANDARD. 23. PERMITTING: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. 24. FIRE SEALING: FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE-RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN INDICATOR OF BUILDING TYPE. BUILDING TYPE LISTED ON LIFE SAFETY PLAN IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION. 25. WALL PENETRATIONS: WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. 26. FLOOR LEVELING: CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED. 27. REPAIR GYPSUM WALLBOARD: REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. 28. EQUIPMENT INSTALLATION: ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. 1. HVAC THERMOSTAT LOCATIONS: POSITION ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR OTHER CONFLICTS. 2. PHONE AND DATA ACCOMMODATIONS: AT EACH PHONE/DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE. 3. ELECTRICAL SWITCH PLATES: PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCH PLATES TO MATCH EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO PURCHASE. 4. WORK STATION POWER: PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN. REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL CONDUITS TO JUNCTION BOXES. 5. LIGHTING CIRCUITS: VERIFY EXISTING LIGHTING CIRCUITING; SIZE NEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES. 6. ELECTRICAL OUTLETS: ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET ADA REQUIREMENTS. 7. LIGHTING SWITCH PLATES: WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVER PLATE. 8. FIXTURE PLACEMENT: CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED. 9. EMERGENCY LIGHTING: PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 10. FIRE ALARM SYSTEM: FIRE SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN-BUILD CONTRACTOR AND MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM DESIGN-BUILD CONTRACTORS ARE RESPONSIBLE FOR COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 11. FIRE ALARM DEVICE LOCATIONS: COORDINATE WITH OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT-INSTALLED ITEMS (I.E. PRESENTATION BOARDS, A/V EQUIPMENT AND PROJECTION SCREENS). FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 12. EXISTING LIGHT FIXTURE RELAMP: IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTING SPACES. CONSULT WITH LANDLORD. 13. HVAC CONTRACTOR AIR BALANCE: CONTRACTOR TO PERFORM AIR BALANCE UPON COMPLETION OF HVAC SCOPE. PROVIDE REPORT TO LANDLORD. 14. HVAC FLEX DUCT: FLEX DUCT MUST MEET ASHRAE STANDARD BUILDING CODES FOR FLEX DUCT LENGTH. 15. ENGINEERED MEP DRAWINGS: THE MECHANICAL, ELECTRICAL AND PLUMBING DESIGN-BUILD CONTRACTORS SHALL COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. WHEN REQUIRED BY STATE BUILDING CODE, THE CONTRACTOR(S) SHALL PROVIDE DESIGN/BUILD DRAWINGS FOR MECHANICAL, PLUMBING, ELECTRICAL, OR FIRE SUPPRESSION. DRAWINGS SHALL BE CERTIFIED BY A LICENSED ENGINEER AND SUBMITTED BY THE CONTRACTOR FOR STATE DESIGN REVIEW. 16. EQUIPMENT INSTALLATIONS: ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. MECHANICAL & ELECTRICAL NOTES - GENERAL ADMINISTRATIVE RULES (675 IAC 12) - 1NDIANA BUILDING CODE, 2014 EDITION (IBC, 2012 EDITION, 675 IAC 13-2.6) - HANDICAPPED ACCESSIBILITY CODE: 2014 INDIANA BUILDING CODE CHAPTER 11, ANSI A117.1-2009, 675 IAC 13-2.6-12) - INDIANA FIRE CODE, 2014 EDITION (IFC 2012 EDITION, 675 IAC 22-2.5) - INDIANA PLUMBING CODE, 2006 EDITION (675 IAC 16-1.4) - INDIANA ELECTRICAL CODE, 2009 EDITION (2008 NFPA 70, 675 IAC 17-1.8) - INDIANA MECHANICAL CODE, 2014 EDITION (IMC, 2012 EDITION, 675 IAC 18-1.6) - ENERGY CONSERVATION CODE, 2010 (ASHREA 90.1, 2007 EDITION, 675 IAC 19.3) EFFECTIVE CODES DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20 x OFFICE 113 11'-4"10'-6" x OFFICE 114 10'-4"10'-6" x OFFICE 115 10'-4"10'-6" x OFFICE 119 10'-1"11'-0" x OFFICE 118 10'-1"11'-0" x OFFICE 117 10'-1"11'-0" OPEN OFFICE 116 COMPETE 106 x SERVER/STG 110 9'-3"11'-10"x RESTROOM 112 6'-6"8'-0" WELCOME 101 x CONFERENCE 103 20'-5"11'-2" x CONFERENCE 107 18'-3"10'-9" x OFFICE 109 10'-6"10'-9" DRINK + GATHER 105 x OFFICE 108 10'-6"10'-9" x OFFICE 102 10'-0"10'-9" OPEN OFFICE 104 FEELNELNELNELNELNELN LIFE SAFETY PLAN L100LIFE SAFETY PLAN DESCRIPTIONDATE ISSUE 06.12.20 REVIEW SET 06.29.20 UPDATED SET 09.09.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 07.29.20 EH PLAN UPDATE 08.12.20 EH CLG UPDATES2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032EHEH 2019.288 1ST FLOOR N 1 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. LIFE SAFETY NOTES L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. GENERAL NOTES 0 8' 16'4' EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT EP EX LEGEND FIRE EXTINGUISHER EXIT SIGN FE EMERGENCY LIGHT FE AREA NOT IN CONTRACT AREA OF WORK TRAVEL DISTANCE - LED EDGE LIT BUSINESS BUSINESS EX EX EX EX EX EX EX SCOPE OF WORK OFFICE REMODEL OF SHELL OFFICE SPACE TOTAL BUILDING AREA TOTAL PROJECT AREA CHANGE OF OCCUPANCY CLASS? OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD NO OCCUPANCY CLASSIFICATION B(USINESS) GEN. OFFICE SF 100 NUMBER OF EXITS REQUIRED: 2 PROVIDED: 3 SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 TOTAL AREA ON THE FLOOR SF SF/FLOOR X STORIES SF SF 19,305 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A = TOTAL OCCUPANTS IN PROJECT AREA 44 CODE SUMMARY PREVIOUS USE OF SPACE B(USINESS) ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN) BUILT BEFORE 1978? NO 4,372 4,372 19,305 4 77,220 44 BUILDING CONSTRUCTION TYPE II-B EP TRAVEL DISTANCE = 152' 1 DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20 FEOFFICE 113 OFFICE 114 OFFICE 115 OFFICE 119 OFFICE 118 OFFICE 117 OPEN OFFICE 116 COMPETE 106 SERVER/STG 110 RESTROOM 112 WELCOME 101 CONFERENCE 103 CONFERENCE 107 OFFICE 109 DRINK + GATHER 105 OFFICE 108 OFFICE 102 OPEN OFFICE 104 11'-5"10'-6" 10'-6"8'-5"3'-10" 9'-71 2" 10'-101 2"10'-103 4" 11'-134"11'-134" 9'-734"11'-7" 10'-43 4"14'-3"4'-0" 8'-0" 5'-91 2"7'-5"8'-934"10'-81 2" 5'-0" CLEAR FE13'-7"WALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT TYPICAL WALL TYPE METAL STUD EXISTING WINDOW MULLION EQUAL & ARCHITECTURAL FLOOR PLAN A111 ARCHITECTURAL PLAN AREA NOT IN CONTRACT AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL WINDOW / SIDELIGHTWINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL DEMISING WALL TO DECK WITH INSULATION 35 8" METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W1 W2 PARTIAL HEIGHT WALL 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 3'-4 12"; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED. WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DESCRIPTIONDATE ISSUE 06.12.20 REVIEW SET 06.29.20 UPDATED SET 09.09.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 07.29.20 EH PLAN UPDATE 08.12.20 EH CLG UPDATES2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032EHEH 2019.288 1ST FLOOR N 1 0 2' 4' 8' 16' DECONSTRUCTION PLAN REMOVE PORTION OF EXISTING WINDOW IN PREPARATION FOR NEW SLIDING DOOR SYSTEM. REFER TO DOOR SCHEDULE. COORDINATE STORAGE OF REMOVED WINDOW WITH PROPERTY MANAGEMENT. RELOCATE EXISTING BUILDING EQUIPMENT FROM THIS LOCATION TO NEW; REFER TO ARCHITECTURAL PLAN. CONTRACTOR TO CONFIRM PURPOSE OF EXISTING POST AT THIS LOCATION. RELOCATE OR RECONFIGURE AS REQUIRED. RELOCATE EXISTING FIRE EXTINGUISHER AND CABINET - REFER TO ARCHITECTURAL PLAN. DECON. PLAN NOTES ELECTRIC OUTLET(S) DATA OR COMMUNICATION OUTLET EXISTING TO BE REMOVED EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WALL DOOR AND FRAME CEILING GRID AND TILES, 2'x4' SUPPLY AIR DIFFUSERS LIGHT FIXTURE, FLUORESCENT, 2'x4' LIGHT FIXTURE, CAN LIGHT SWITCH LIGHT FIXTURE, FLUORESCENT, 2'x2' WINDOW / SIDELIGHT CEILING GRID AND TILES, 2'x2' LIGHT FIXTURE, TRACK LIGHT FIXTURE, SCONCE LIGHT FIXTURE, PENDANT EXIT LIGHT DECONSTRUCTION LEGEND AREA NOT IN CONTRACT AREA OF WORK DECONSTRUCTION ARCH. GENERAL NOTES PARTIAL HEIGHT WALLPARTIAL HEIGHT WALL ARCH. PLAN NOTES TYP. A111 1 0 2' 4' 8' 16' NOT TO SCALE WALL AT MULLION DETAIL A111 1 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. ALL STEEL, CROSSBRACING, AND COLUMNS TO REMAIN EXPOSED UNLESS NOTED OTHERWISE. REFER TO FINISH PLAN FOR MORE INFORMATION. 4. PROVIDE BUILDING STANDARD MANUALLY OPERATED WINDOW SHADES AT ALL EXTERIOR WINDOWS. CONFIRM SPEC AND COLOR OF SHADES WITH TENANT. ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. CONTRACTOR TO INSTALL SALVAGED FIRE EXTINGUISHER AND CABINET AT THIS LOCATION. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE NEW AS REQUIRED. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. NEW WALL CONSTRUCTION TO MATCH ADJACENT COMMON CORRIDOR WALL CONSTRUCTION. WRAP COLUMN AS TIGHTLY AS POSSIBLE WITH NEW WALL CONSTRUCTION. IN AREA WITH EXPOSED CEILING DECK, ENSURE THAT DRYWALL ON ALL NEW AND EXISTING WALLS EXTENDS TO DECK; PROVIDE NEW DRYWALL AS REQUIRED. TRANSITION TO BE A CLEAN HORIZONTAL LINE FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. SEE REFLECTED CEILING PLAN FOR EXACT AREA OF EXPOSED CEILING. NOT USED. PROVIDE 1 2" TEMPERED BUTT-GLAZED GLASS FRAMELESS CORNER WINDOW AT THIS LOCATION. REFER TO DOOR SCHEDULE AND FRAME TYPE FOR MORE INFORMATION. COORDINATE ALL REQUIREMENTS FOR TENANT'S KEG AT THIS LOCATION. EMERGENCY LIGHT 1. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T111. 2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR SALVAGED FOR LANLORD. FOR ALL ITEMS DETERMINED FOR REMOVAL, REFER TO THE RECYCLING INSTRUCTIONS. 3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. 4. SALVAGE REMOVED LIGHT FIXTURES AND HVAC DIFFUSERS FOR REUSE. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. DECON. GENERAL NOTES RECYCLING INSTRUCTIONS METALS ONLY RECYCLING BIN: 1. CONTACT WASTE HAULER TO ORDER TRASH DUMPSTER(S) AS REQUIRED AND (1) "METALS ONLY" RECYCLING BIN FOR THE DEMOLITION PORTION OF PROJECT ONLY. SIZE OF "METALS ONLY" BIN IS DETERMINED BY THE AMOUNT OF DEMOLITION (10-40 YARD CONTAINERS AVAILABLE). 2. DRYWALL MUST BE REMOVED FROM ALL METAL STUDS PRIOR TO PLACING IN "METALS ONLY" BIN. ANY ADDED LABOR COST WILL BE COVERED BY METAL CREDITS RECEIVED FROM WASTE HAULER. 3. WASTE HAULER WILL APPLY CREDIT FOR METALS OBTAINED IN "METALS ONLY" BIN TOWARDS CONTRACTORS OVERALL INVOICE. 4. DATA/DIVERSION REPORTS ARE NOT REQUIRED NOR ANY LEED PROCESSES OR PAPERWORK. APPROVED METAL ITEMS: 5. METAL STUDS, DOOR FRAMES, DOOR HARDWARE, CEILING GRID, LIGHT BOX FIXTURES, METAL CABINETS, METAL PLUMBING FIXTURES, ELECTRICAL AND DATA WIRING/CONDUIT, HVAC COMPONENTS, AND ELECTRICAL/DATA/SWITCH BOXES CONTACT EMILY HILLYER (317) 762-7840 AT SCHOTT DESIGN FOR ANY QUESTIONS REGARDING THE RECYCLING PROCESSES. W2 W2 W2 A141 4 SUPPORT COUNTER AS REQUIRED WITH CENTERLINE BRACKET'S FRONT MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. DESIGN INTENT IS FOR VERTICAL SUPPORT TO BE CONCEALED BY DRYWALL. REFER TO ELEVATION AND SECTION FOR MORE INFORMATION. AT EXISTING STEEL COLUMN, COORDINATE WITH TENANT ON EXACT TV SPECIFICATIONS AND PROVIDE APPROPRIATE CEILING MOUNTED SUPPORT + BRACKET AS REQUIRED FOR TELEVISION. COORDINATE MOUNTING HEIGHT WITH TENANT. PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. PROVIDE WATER LINE FOR TENANT'S COFFEE MAKER AND WATER MACHINE. CONFIRM FINAL LOCATIONS WITH TENANT. PROVIDE COLD WATER SUPPLY AND WATER LINES AS REQUIRED FOR NEW TOILET. RELOCATE EXISTING BUILDING EQUIPMENT TO THIS LOCATION. A211 1 A211 2 A211 2 SIM A211 3,4,5 A211 6 1 1 DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20 OFFICE 113 OFFICE 114 OFFICE 115 OFFICE 119 OFFICE 118 OFFICE 117 OPEN OFFICE 116 COMPETE 106 SERVER/STG 110 RESTROOM 112 WELCOME 101 TVCONFERENCE 103 CONFERENCE 107 OFFICE 109 DRINK + GATHER 105 U.C. REFRIG U.C. KEG TV321123OFFICE 108 OFFICE 102 OPEN OFFICE 104 +60"+60"+42"GFCI+44"GFCIJJJJJJ +42" GFCI +60" +60"DED+60"+60"+60" +60"+60" +60"+60"+60"+60" +60"+60" +60" +60" +60" +60" +60" +60" +60" +44"GFCI +72" +72" OFFICE 113 OFFICE 114 OFFICE 115 OFFICE 119 OFFICE 118 OFFICE 117 OPEN OFFICE 116 COMPETE 106 SERVER/STG 110 RESTROOM 112 WELCOME 101 TVCONFERENCE 103 CONFERENCE 107 OFFICE 109 DRINK + GATHER 105 U.C. REFRIG U.C. KEG TV321123OFFICE 108 OFFICE 102 OPEN OFFICE 104 +60"+60"+42"GFCI+44"GFCIJ JJJJJ +42" GFCI +60" +60"DED+60"+60"+60" +60"+60" +60" +60"+60"+60" +60"+60" +60" +60" +60" +60" +60" +60" +60" +44"GFCI +72" +72"SN16'-0" 12'-0" TYP.8'-0"L; 8'-6" AFFELNELNELNELNELNELN SNSNSNSNS N SNSN3SNSNSNSNS NSNSN3 SNSN3SN3SN16'-0" 12'-0" TYP.8'-0"L; 8'-6" AFFELNELNELNELNELNELN SNSNSNSNS N SNSN3SNSNSNSNS NSNSN3 SNSN3SN38'-0"9'-0"REFLECTED CEILING PLAN A121 REFLECTED CEILING PLAN DESCRIPTIONDATE ISSUE 06.12.20 REVIEW SET 06.29.20 UPDATED SET 09.09.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 07.29.20 EH PLAN UPDATE 08.12.20 EH CLG UPDATES2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032EHEH 2019.288 1ST FLOOR N 1 0 2' 4' 8' 16' AREA NOT IN CONTRACT AREA OF WORK AREA NOT IN CONTRACT AREA OF WORK ELECTRICAL PLAN NOTES ELECTRICAL PLAN DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, QUADRUPLEX JUNCTION BOX POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX BOX, BLANK COVER PLATE BOX, OPEN BOX, BLANK COVER PLATE BOX, OPEN POWER AND DATA POLE FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL LEGEND CEILING MOUNTED JUNCTION BOX CEILING MOUNTED JUNCTION BOX ELECTRICAL PLAN/ RCP PLAN NOTES GENERAL ELEC. NOTES CONTROL WELCOME 101, OPEN OFFICE 104, COMPETE 106, OPEN OFFICE 116 AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. CLEAN ALL EXPOSED SURFACES; EXISTING SURFACES TO REMAIN AS-IS. PROVIDE RIGID SPIRAL DUCT AND ROUND SUPPLY DIFFUSERS AS REQUIRED IN THIS AREA. INSTALL TENANT'S OVERHEAD PROJECTOR + AUTOMATIC PROJECTOR SCREEN IN THIS AREA. ALL FINAL DETAILS AND LOCATION TO BE COORDINATED WITH TENANT. INSTALL FLOATING CLOUD WITH ARMSTRONG AXIOM TRIM AROUND PERIMETER (6"; WHITE). GRID AND TILE TO BE 2'x2' SUITE STANDARD (REFER TO GENERAL CEILING NOTE 1). HEIGHT TO UNDERSIDE OF CEILING CLOUD TO BE AT 10'-0" AFF. FLOAT CLOUD WITH ALL-THREAD INSTALLED 15" FROM EDGES. PAINT ALL THREAD SAME COLOR AS CEILING DECK. INSTALL MINIMAL QUANTITY OF ALL-THREAD SUPPORTS AS POSSIBLE AND MAKE ALL THREAD SUPPORTS AS VISUALLY UNOBTRUSIVE AS POSSIBLE. CONSULT WITH PHIL CAITO (317.519.2829) FOR FINAL SIZES, SPECIFICATIONS, ETC. NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW CLOUD. FIRE SPRINKLER CONTRACTOR TO PROVIDE SUBMITTAL OF FINAL LAY-OUT FOR FINAL APPROVAL PRIOR TO INSTALLATION. PROVIDE 4 7 8" WIDE BULKHEAD AT 8'-10" AFF AT THIS LOCATION. BULKHEAD TO EXTEND TO DECK AND ALIGN WITH ADJACENT WALLS AS SHOWN. INTENT IS FOR CEILING GRID AT 9'-0" TO DIE INTO BULKHEAD AS SHOWN. ALL FACES OF BULKHEAD TO BE PAINTED PT2; FLAT FINISH. PROVIDE DRYWALL CEILING AT 10'-0" AFF THIS LOCATION WITH ARMSTRONG AXIOM TRIM AROUND PERIMETER (6"; WHITE) - REFER TO PLANS FOR DIMENSIONS. INTENT IS FOR DRYWALL CEILING TO ALIGN WITH ADJACENT WALL AS SHOWN. UNDERSIDE OF DRYWALL CEILING TO RECEIVE SPECIALTY FINISH - REFER TO FINISH PLANS. CLEAN ALL EXPOSED SURFACES AND PREPARE FOR DRYFALL PAINT (PT6) AS NOTED ON PLAN PER MANUFACTURER'S RECOMMENDATIONS. PAINT EXISTING EXPOSED STRUCTURAL BEAMS AND CROSSBRACING IN ACCORDANCE WITH NFPA 13 6.3.8. ALL STRUCTURAL BEAMS INTENDED TO BE PAINTED ARE CURRENTLY DARK GRAY; CONFIRM AREAS TO BE PAINTED WITH SDI AS REQUIRED. BASE BID: UNDERSIDE OF DECK TO REMAIN AS-IS AND BE CLEANED AS NEEDED. SEPARATE PRICE: ON UNDERSIDE OF DECK ONLY (NO OTHER CEILING ELEMENTS), PROVIDE K13 ACOUSTICAL CEILING TREATMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND ALL STATE + LOCAL CODES. K13 TO BE PAINTED WITH DRYFALL PAINT (PT5). 0 2' 4' 8' 16' 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL EXISTING AND NEW DEVICES + FACE PLATES TO BE WHITE; REPLACE AS REQUIRED. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. J J B O J +42" PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. COORDINATE POWER REQUIREMENTS IN THIS ROOM WITH TENANT. PROVIDE DEDICATED RECEPTACLES AS REQUIRED. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. PROVIDE POWER FOR TENANT'S UNDERCOUNTER REFRIGERATOR AND/OR KEG. PROVIDE POWER FOR TENANT'S OVERHEAD PROJECTOR + AUTOMATIC PROJECTOR SCREEN IN THIS AREA. FINAL DETAILS AND LOCATION TO BE COORDINATED WITH TENANT. PROVIDE DIRECT HDMI/VGA CONDUIT CONNECTION FROM FLOOR CORE POKE THRU DEVICE TO WALL MOUNTED MONITOR(S). PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND/OR JUNCTION BOX + DATA. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. OUTLETS AT THIS LOCATION TO BE INSTALLED HORIZONTALLY. ALL ABOVE COUNTER OUTLETS ARE FOR DEDICATED APPLIANCE USE ONLY. CONVENIENCE OUTLETS ARE LOCATED ELSEWHERE IN ROOM. PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE CONNECTION. POWER POLE BY OTHERS. LIGHT CIRCUIT LIGHT SWITCH, 3-WAY DIMMER LIGHT SWITCH, DIMMERN N3 3 EXIT LIGHT FIXTURE CEILING GRID, SUSPENDED, 2'x2' NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, PENDANT LIGHT FIXTURE, 1'x4', FLUORESCENT, INDIRECT EXIT LIGHT FIXTURE LIGHT CIRCUIT LIGHT SWITCH, 3-WAY LIGHT SWITCH GYPSUM BOARD CEILING LIGHT FIXTURE, 2'x2', FLUORESCENT, PARABOLIC LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC RCP LEGEND RECESSED LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EXHAUST FAN, 2'x2' EXPOSED TO DECK 1. WHERE SHOWN, PROVIDE NEW 2'x2' 916" CEILING GRID AND 2'x2' FINE FISSURED REVEAL EDGE CEILING TILE (ARMSTRONG DUNE, OR SIMILAR). GRID TO BE INSTALLED AT 9'-0" AFF. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 5. EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE; REPLACE AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.  ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 7. PROVIDE SOUND DAMPERS IN HVAC SYSTEM SUCH THAT SOUND TRANSMISSION BETWEEN ROOMS IS REDUCED. 8. EXHAUST FAN IN RESTROOM TO BE TIED INTO SWITCH FOR LIGHT FIXTURE SUCH THAT SWITCH CONTROLS BOTH. SPECIFICATION FOR EXHAUST FAN MUST BE APPROVED BY TENANT PRIOR TO ORDERING. 9. PROVIDE SEPARATE PRICE FOR (25) ARMSTRONG TECTUM DIRECT-ATTACH ACOUSTICAL CEILING PANELS; 24X48, VERTICAL LINE DESIGN, WHITE. IF SEPARATE PRICE IS ACCEPTED, COORDINATE WITH SDI ON INSTALLATION LOCATIONS. GENERAL NOTES LIGHT FIXTURE, LED PENDANT - KUZCO LIGHTING MONAE - MEDIUM SIZE. MOUNT AT 8'-0" TO BOTTOM OF FIXTURE. LIGHT FIXTURE, 2'x4', LED, COLUMBIA LIGHTING LCAT, 3500K (OR EQUAL) LIGHT FIXTURE, FINELITE HP-2 I/D (OR EQUAL), MOUNT AT 9'-0" AFF TO BOTTOM OF FIXTURE. SEE LENGTH OF FIXTURE AS NOTED ON PLAN. LIGHT FIXTURE, 6" LED CAN LIGHT; 3500K PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND/OR JUNCTION BOX + DATA. INTENT IS FOR POKE THRU DEVICE AT THIS LOCATION TO BE COMPLETELY FLUSH WITH ADJACENT FLOOR AND CONCEAL POWER AND DATA BELOW. COORDINATE WITH TENANT + TENANT'S FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. AT EXISTING STEEL COLUMN, COORDINATE WITH TENANT ON EXACT TV SPECIFICATIONS AND PROVIDE APPROPRIATE POWER + DATA, CONDUIT, AND J-BOX AS REQUIRED FOR TELEVISION. COORDINATE MOUNTING HEIGHT WITH TENANT. PROVIDE POWER AS REQURED FOR TENANT'S WATER MACHINE AND UNDERCOUNTER REFRIGERATOR AT THIS LOCATION. 1 1 2 DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20 BASE AS SCHEDULED PT3 PT1 6'-0"4'-0"PT3 DESIGN INTENT IS FOR EDGES OF PAINTED AREA TO ALIGN AT CORNERS FOR CONTINUOUS/ WRAPPED APPEARANCE OFFICE 113 OFFICE 114 OFFICE 115 OFFICE 119 OFFICE 118 OFFICE 117 OPEN OFFICE 116 COMPETE 106 SERVER/STG 110 RESTROOM 112 WELCOME 101 CONFERENCE 103 CONFERENCE 107 OFFICE 109 DRINK + GATHER 105 U.C. REFRIG U.C. KEG OFFICE 108 OFFICE 102 OPEN OFFICE 104 12'-0"31'-0"BASE AS SCHEDULED PT3 PT1 4'-0"7'-0"PT3 DESIGN INTENT IS FOR EDGES OF PAINTED AREA TO ALIGN AT CORNERS FOR CONTINUOUS/ WRAPPED APPEARANCE CORNER OF SERVER/STG 110 BASE AS SCHEDULED PT3 PT1 7'-0"4'-0"PT3 DESIGN INTENT IS FOR EDGES OF PAINTED AREA TO ALIGN AT CORNERS FOR CONTINUOUS/ WRAPPED APPEARANCE CORNER OF SERVER/STG 110 CORNER OF RESTROOM 112 FINISH PLAN A131FINISH PLANAREA NOT IN CONTRACT AREA OF WORK DESCRIPTIONDATE ISSUE 06.12.20 REVIEW SET 06.29.20 UPDATED SET 09.09.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 07.29.20 EH PLAN UPDATE 08.12.20 EH CLG UPDATES2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032EHEH 2019.288 1ST FLOOR N 1 0 2' 4' 8' 16' 0 2' 4'1' ELEVATION - OPEN OFFICE 116 A131 1 1. REFER TO LEGEND FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 2. CONTRACTOR TO EVALUATE EXISTING FLOORING CONDITIONS AFTER DECONSTRUCTION IS COMPLETE AND PREP AS NECESSARY PER MANUFACTURERS RECOMMENDATIONS. SEALCOAT THE CONCRETE FLOOR PRIOR TO LAYING ADHESIVE IF DEEMED NECESSARY. 3. AT ALL FLOOR TILE LOCATIONS PROVIDE WATERPROOFING CRACK ISOLATION MEMBRANE:  TEC HYDRAFLEX FULL COVERAGE PER TCNA F125-11 FULL. PROVIDE CONTROL JOINTS EVERY 12' AT MINIMUM OR AS RECOMMENDED BY MANUFACTURER. 4. AT NEW WALL TILE LOCATIONS PROVIDE APPROPRIATE SUBSTRATE FOR WALL TILE (AT NEW WALLS CEMENT BACKER BOARD) AS RECOMMENDED BY MANUFACTURER. 5. CLEAN ALL EXPOSED SURFACES OF EXISTING EXPOSED STRUCTURAL BEAMS, CROSSBRACING, AND EXPOSED COLUMNS AND PREPARE FOR DRYFALL PAINT (PT6) PER MANUFACTURER'S RECOMMENDATIONS. PAINT IN ACCORDANCE WITH NFPA 13 6.3.8. ALL STRUCTURAL BEAMS INTENDED TO BE PAINTED ARE CURRENTLY DARK GRAY; CONFIRM AREAS TO BE PAINTED WITH SDI AS REQUIRED. DRYWALL BEHIND CROSSBRACING TO BE WALLCOVERING AS NOTED ON PLANS. PLAN NOTES ALL FINISHES SHALL MEET ALL CLASS A FIRE RATINGS AND COMPLY WITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE. LEGEND GENERAL NOTES CARPET FLOOR COVERINGS MFG: J+J FLOORING TYPE: MODULAR CARPET TILE; 24X24 PATTERN: WELL VERSED 7072 COLOR: BLAKE 2027 INSTALL: BRICK WALL BASE MFG: JOHNSONITE TYPE: 4" VINYL COVE, 18" GAUGE COLOR: 48 GREY PAINT / WALLCOVERING MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: SILVERPLATE SW7649 FINISH: EGGSHELL PLASTIC LAMINATE / SOLID SURFACE MFG: WILSONART COLOR: MAGNOLIA 5012K-19 MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: EXTRA WHITE SW7006 FINISH: EGGSHELL MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: IRON ORE SW7069 FINISH: EGGSHELL MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: HABANERO CHILE SW7589 FINISH: EGGSHELL MFG: CORIAN QUARTZ COLOR: GALAXY BLACK MISCELLANEOUS MFG: STIKWOOD (WOOD PANELING) COLOR: RECLAIMED ARABICA NOTES: PANELS UTILIZE PEEL AND STICK INSTALL. 316" THICK, 5" WIDE, RANDOM VARIATION OF 1' TO 4' LENGTHS. INSTALL TO GO FROM TOP OF CARPET TO UNDERSIDE OF CEILING. NO VINYL BASE AT THIS WALL; PROVIDE QUARTER-ROUND STAINED TO MATCH AT BASE (UNLESS NOTED OTHERWISE) AND ALL EXPOSED EDGES. CONTACT CHERI LONGERBONE AT 317.402.3467 TO ENSURE SPECIAL PRICING. FLOOR TILE MFG: LOUISVILLE TILE - CROSSVILLE SIZE: 12X24 COLOR: GOTHAM - PAVEMENT GROUT: EQUAL TO TEC 550 POWER GROUT; JOINT TO BE 18"; COLOR: CHARCOAL GREY INSTALL: MONOLITHIC; FLOOR AND WALL TILE GROUT LINES TO ALIGN MFG: MDC - THOM FILICIA TYPE: VINYL PATTERN: TOGGLE COLOR: TFC1224 HADLEY MFG: WILSONART COLOR: WALNUT HEIGHTS 7965K-12 MFG: KRYLON TYPE: ACRYLIC DRYFALL COLOR: TO MATCH SHERWIN WILLIAMS EXTRA WHITE SW7006 FINISH: EGGSHELL MFG: MDC - THOM FILICIA TYPE: VINYL PATTERN: TOGGLE COLOR: TFC1225 WRAITH MFG: LOUISVILLE TILE - CROSSVILLE SIZE: 12X24 COLOR: GOTHAM - PAVEMENT GROUT: EQUAL TO TEC 550 POWER GROUT; JOINT TO BE 18"; COLOR: CHARCOAL GREY INSTALL: TILE TO EXTEND TO 48" AFF ON ALL WALLS. INSTALLMONOLITHICALLY/STACKED BOND WITH LENGTH OF TILE RUNNING HORIZONTALLY. PROVIDE APPROPRIATE SCHULTER TRIM PIECE AT EXPOSED TOP OF TILE IN BRUSHED STAINLESS. ANY GROUT LINES TO ALIGN WITH GROUT LINES OF FLOOR TILE. CONCRETE POLISHED CONCRETE FLOOR MFG: SHAW CONTRACT TYPE: MODULAR CARPET TILE PATTERN: INSIDE SHAPES - IMPRESSION II 5T258 COLOR: GREY DARK IM007 INSTALL: RANDOM PROVIDE SCHLUTER RENO-U METAL TRANSITION STRIP AT TRANSITION FROM CONCRETE FLOOR TO TILE/CARPET. FINISH: STAINLESS STEEL. WALL TO BE PAINTED IN PT3 PRIOR TO INSTALLATION OF WP1. LEVEL 5 SURFACE NOT REQUIRED AT THIS LOCATION. AT UNDERSIDE OF DRYWALL CEILING IN THIS LOCATION, PAINT SURFACE IN PT3, THEN INSTALL WP1. LEVEL 5 SURFACE NOT REQUIRED AT THIS LOCATION. COORDINATE ALL FINISH REQUIREMENTS WITH LANDLORD IN COMMON CORRIDOR . DESIGN INTENT IS FOR NEW FINISHES TO MATCH AND APPEAR CONTINUOUS WITH EXISTING. MFG: KRYLON TYPE: ACRYLIC DRYFALL COLOR: TO MATCH SHERWIN WILLIAMS TRICORN BLACK SW6258 FINISH: EGGSHELL MFG: CORIAN QUARTZ COLOR: INDUS RED MFG: CORIAN QUARTZ COLOR: SNOW FLURRY A131 1 A131 2 A131 3 0 2' 4'1' ELEVATION - OPEN OFFICE 116 A131 2 0 2' 4'1' ELEVATION - OPEN OFFICE 116 A131 3 1 DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20 WATERCLOSET - WALL MOUNT SIDE VIEW FRONT VIEW 60"W. x 60"D. CLEAR SPACE 18" 12" 44" MAX17"-19"33"-36"24"44" MAX.12" MAX 54"MIN 36"MAX 33"-36"39" TO 41"112" MIN.7"-9"18"17"-19"24" PREFERRED(19" MIN.)39"-41"24" PREFERRED(19" MIN.)MANUAL FLUSH CONTROL ON SIDE OPPOSITE WALL 18" AWAYGRAB BAR TOILET PAPER DISPENSER INSTALLED AS HIGH AS ALLOWABLE PER ADA GUIDELINES COORDINATE LOCATION OF FLUSH VALVE WITH GRAB BARS POSITION FLUSH CONTROL ON WIDE SIDE OF TOILET STALL CL COUNTERTOP LAVATORY - SECTION VIEW 6"MAX 27" MIN8" MIN.34" MAX38" MAX30"W. x 48"D. CLEAR SPACE 24" (17" MIN.)9" MINMIRROR SOAP DISPENSER KNEE AND TOE CLEAR AREA KEEP PLUMBING AWAY FROM KNEE AND TOE CLEAR AREA BOTTOM OF MIRROR REFLECTING SURFACE 4"H QUARTZ (QZ3) BACK SPLASH 7"H QUARTZ (QZ3) FIXED PANEL REMOVABLE PLASTIC LAMINATE (PL2) PANEL, PROVIDE CLIPS TO ATTACH 34" MAXMIRROR 27" MINCOUNTERTOP SINGLE LAVATORY - FRONT VIEW FIXED PANEL, QZ3 REMOVABLE PANEL, PROVIDE CLIPS TO ATTACH. PL2 SOAP DISPENSER 38" MAX 9" MIN2'-0"3'-6" 3'-6"L X 2'-0"D COUNTERTOP, QZ1 7"PAPER TOWEL DISPENSER AND DISPOSAL FORWARD REACHTO INSURE59.5" MAX.48" MAXEXIST 4"V. EXIST 4"W. 4"W. F.F. 2"W. 4"W. SINK TO BUILDING DRAIN F.F. CLG. CLG. TO EXISTING STACK 3"W. 2"V. W.C. 112"V. 2"V. EXIST 4"V. EXIST 4"W. 2"W. F.F. 2"W. 2"W. SINK TO BUILDING DRAIN F.F. 112"V. CLG. 112"V. CLG. TO EXISTING STACK RESTROOM DETAILS A141NOTE: ALL A.D.A. COMPLIANT CONSTRUCTION, FIXTURE MOUNTINGS, AND ACCESSORY MOUNTINGS MUST COMPLY WITH INDIANA ACCESSIBILITY REGULATIONS (INDIANA BUILDING CODE (IBC), CHAPTER 11: ACCESSIBILITY; 675 IAC 13-2.6). DESCRIPTIONDATE ISSUE 06.12.20 REVIEW SET 06.29.20 UPDATED SET 09.09.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 07.29.20 EH PLAN UPDATE 08.12.20 EH CLG UPDATES THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032EHEH 2019.288 1ST FLOOR N 0 2' 4'1' ENLARGED PLAN - RESTROOM 112 A141 4 0 1' 2' 4'6" ADA ACCESSORY DETAILS A141 3 0 1' 2' 4'6" ADA PLUMBING FIXTURE DETAILS A141 1 GENERAL NOTES: AC1. FURNISH CUT SHEETS OF ACCESSORIES TO GENERAL CONTRACTOR FOR APPROVAL. AC2. PROVIDE BUILDING STANDARD RESTROOM SIGNAGE AS REQUIRED. GENERAL NOTES: PF1. ALL PLUMBING FIXTURES AND ACCESSORIES ARE TO BE SELECTED BY THE PLUMBING CONTRACTOR. PF2. VERIFY EXISTING FIXTURES IN EXISTING BUILDING RESTROOMS AND SELECT SIMILAR FIXTURES. PF3. FURNISH CUT SHEETS OF ALL FIXTURES TO GENERAL CONTRACTOR FOR APPROVAL. LAVATORY - ADA ACCESSIBLE: UNDERMOUNT WHITE PORCELAIN (SEE DETAILS FOR MOUNTING HEIGHTS) PLUMBING FIXTURE LEGENDACCESSORIES LEGEND GRAB BAR: 112" DIAMETER, BRUSHED STAINLESS 42" LONG (BESIDE TOILET) (SEE DETAILS FOR MOUNTING HEIGHTS) GRAB BAR: 112" DIAMETER, BRUSHED STAINLESS 36" LONG (BEHIND TOILET) (SEE DETAILS FOR MOUNTING HEIGHTS) MIRROR (ABOVE COUNTER - TRUEBLOOD RESTROOM): CB2 INFINITY BLACK ROUND WALL MIRROR 24" BLACK FRAME (SEE DETAILS FOR MOUNTING HEIGHT) PAPER TOWEL DISPENSER/TRASH RECEPTACLE: SEMI-RECESSED (312" RECESS), BRUSHED STAINLESS (SEE DETAILS FOR MOUNTING HEIGHT) TOILET PAPER HOLDER (DOUBLE): DOUBLE ROLL, BRUSHED STAINLESS WALL MOUNTED (SEE DETAILS FOR MOUNTING HEIGHTS) GRAB BAR: 112" DIAMETER, BRUSHED STAINLESS 18" LONG (VERTICAL BESIDE TOILET) (SEE DETAILS FOR MOUNTING HEIGHTS) MANUAL FAUCET: SINGLE LEVER CONTROL, BRUSHED STAINLESS SIGNAGE: PROVIDE BUILDING STANDARD DOOR SIGNAGE AS REQUIRED. SIGNAGE TO COMPLY WITH ALL INDIANA ACCESSIBILITY REGULATIONS. CONFIRM EXACT LOCATION WITH BUILDING LANDLORD/TENANT. WATER CLOSET - ADA ACCESSIBLE: WALL MOUNTED WITH MANUAL VALVE (SEE DETAILS FOR MOUNTING HEIGHTS) MANUAL SOAP DISPENSER: RECESSED COUNTER MOUNT. REFER TO PLAN. NOT TO SCALE RISER DIAGRAMS A141 2 RESTROOM 112 SINGLE SINK LOCATIONS NOTE: REFER TO FLOOR PLAN AND CASEWORK ELEVATIONS FOR LOCATIONS DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20 PROVIDE 3/8" TEMPERED GLASS WINDOW. WINDOW TO BE FRAMELESS WITH RECESSED CONCEALED U-CHANNELS AS REQUIRED. WINDOW TO BE CENTERED ON WALL. PROVIDE PAINTED (PT3) WALL SURFACE WITH STIKWOOD WALL PANELING (WP1) INSTALLED OVER. PROVIDE QUARTER ROUND STAINED TO MATCH FLOOR AND ALL REQUIRED EDGE PIECES AT EXPOSED EDGE. INTENT IS FOR THIS FACE OF DRYWALL AND UNDERSIDE OF BULKHEAD ABOVE TO BE FINISHED IN THIS WAY.2'-0" 5'-0" 5'-0" 106°74°106°74 °5'-0" ARMSTRONG AXIOM TRIM (6", WHITE)3'-0"8'-0" PROVIDE SEPARATE PRICE FOR CLEAR ACRYLIC PANEL AT THIS LOCATION WITH EDGE LIT RGB LED STRIP LIGHT AT BOTTOM CHANNEL. PROVIDE SUBMITTAL TO SDI FOR PROPOSED STRIP LIGHTING IF SEPARATE PRICE IS ACCEPTED. F2 F1 3'-0" 3'-4" 2" 2"REFER TO DOOR SCHED. 2" F4 F5F3 7'-8" 3'-0" 2" REFER TO DOOR SCHED. 2"2" 4'-2" 2" 3 8" TEMPERED BUTT GLAZED GLASS; PROVIDE CLEAR POLYMER STRIP AT JOINT 9'-2" 3'-0" 2" REFER TO DOOR SCHED. 2"2" 5'-8" 2" 3 8" TEMPERED BUTT GLAZED GLASS; PROVIDE CLEAR POLYMER STRIP AT JOINT 9'-8" 3'-0" 2" REFER TO DOOR SCHED. 2"2" 6'-2" 2" 3 8" TEMPERED BUTT GLAZED GLASS; PROVIDE CLEAR POLYMER STRIP AT JOINT 4" STAINLESS STEEL TOP RAIL 12" TEMPERED BUTT GLAZED GLASS; PROVIDE CLEAR POLYMER STRIP AT JOINTS 4" STAINLESS STEEL BOTTOM RAIL 10'-0" EQ. EQ. EQ. EQ.REFER TO DOOR SCHED.D1 3'-0"1'-0" 8"7" 7"REFER TO DOOR SCHED.3'-0" D2 D3 14" TEMPERED GLASS 3'-0" PROVIDE ONE PULL ON EACH SIDE OF DOOR (TOTAL COUNT 2), AS NOTED 4" STAINLESS STEEL TOP RAIL 1/2" TEMPERED GLASS 4" STAINLESS STEEL BOTTOM RAIL 3'-0" REFER TO DOOR SCHED.D4 3'-0" PROVIDE ONE PULL ON EACH SIDE OF DOOR (TOTAL COUNT 2), AS NOTED 4" STAINLESS STEEL TOP RAIL 12" TEMPERED BUTT GLAZED GLASS; PROVIDE CLEAR POLYMER STRIP AT JOINTS 4" STAINLESS STEEL BOTTOM RAIL EQ. REFER TO DOOR SCHED.17'-0" EQ. EQ. EQ. EQ. D5 3'-0" PROVIDE ONE PULL ON EACH SIDE OF DOOR (TOTAL COUNT 2), AS NOTED 4" STAINLESS STEEL TOP RAIL 12" TEMPERED BUTT GLAZED GLASS; PROVIDE CLEAR POLYMER STRIP AT JOINTS 4" STAINLESS STEEL BOTTOM RAIL 9'-0" EQ. EQ. 1'-0"3'-6"15" DEEP QUARTZ (QZ2) BAR TOP VINYL BASE AS SCHEDULED WALLCOVERING AS SCHEDULED PROVIDE MITRED WATERFALL EDGE AT BAR TOP (QZ2). NO VINYL BASE AT QUARTZ.3'-0" 6"UNDER COUNTER REFRIG. BY TENANT UNDER COUNTER KEG BY TENANT 4'-0" 25" DEEP QUARTZ (QZ1) COUNTERTOP WITH 5" HIGH BACK SPLASH. INTENT IS FOR BACKSPLASH TO ALIGN WITH OUTSIDE EDGE OF BAR TOP. PROVIDE 15" DEEP QUARTZ (QZ2) COUNTERTOP AT 42" AFF WITH MITREFOLD EDGE DETAIL AT CORNER SUCH THAT HORIZONTAL QUARTZ WATERFALLS TO FLOOR. NO VINYL BASE AT QUARTZ AND NO MITREFOLD/WATERFALL AT STANDARD HEIGHT COUNTER. PROVIDE PLASTIC LAMINATE (PL1) END PANEL AT THIS LOCATION. PROVIDE PLASTIC LAMINATE (PL1) FILLER PANEL AT THIS LOCATION. VERTICAL SUPPORTS MUST BE CONCEALED BY DRYWALL.2'-10"DROP COUNTER TO 34" AFF AND PROVIDE MITRED TRANSITION BETWEEN DIFFERING COUNTERTOP HEIGHTS 3'-11" SINGLE BOWL SINK: ELKAY QUARTZ CLASSIC 245 8"x18 12"x912" SINGLE BOWL UNDERMOUNT SINK ELGU2522BK0, COLOR: BLACK, KOHLER SIMPLICE FAUCET #K-597-BL(OR EQUAL) PLASTIC LAMINATE (PL1) END PANEL 3'-0"6"15" DEEP QUARTZ (QZ2) COUNTER TOP 25" DEEP QUARTZ (QZ1) COUNTERTOP WITH 5" HIGH BACK SPLASH. INTENT IS FOR BACKSPLASH TO MITRE WITH OUTSIDE EDGE OF BAR TOP (QZ2). MITREFOLDED WATERFALL EDGE MITREFOLDED WATERFALL EDGE PLASTIC LAMINATE (PL1) END PANEL PLASTIC LAMINATE (PL1) BASE CABINETS (SEE CASEWORK NOTE 1) DROP COUNTER TO 34" AFF AND PROVIDE MITRED TRANSITION BETWEEN DIFFERING COUNTERTOP HEIGHTS.2'-10" 8" 25" DEEP QUARTZ (QZ1) COUNTERTOP WITH 5" HIGH BACK SPLASH. INTENT IS FOR BACKSPLASH TO MITRE WITH OUTSIDE EDGE OF BAR TOP (QZ2). PROVIDE 15" DEEP QUARTZ (QZ2) COUNTERTOP AT 42" AFF WITH MITREFOLD EDGE DETAIL AT CORNER SUCH THAT HORIZONTAL QUARTZ WATERFALLS TO FLOOR. NO VINYL BASE AT QUARTZ AND NO MITREFOLD/WATERFALL AT STANDARD HEIGHT COUNTER. PROVIDE PLASTIC LAMINATE (PL1) END PANEL AT THIS LOCATION. 2'-9" PLASTIC LAMINATE (PL1) BASE CABINETS (SEE CASEWORK NOTE 1) VERTICAL SUPPORTS MUST BE CONCEALED BY DRYWALL. DROP COUNTER TO 34" AFF AND PROVIDE MITRED TRANSITION BETWEEN DIFFERING COUNTERTOP HEIGHTS. 2'-0" PULL OUT TRASH DRAWER TO BE PLASTIC LAMINATE (PL1) FRONT PANEL WITH ROLLING HARDWARE AND 8" HIGH DRAWER INSIDE FOR TENANT'S TRASH CAN TENANT PROVIDED FLATSCREEN. PROVIDE BLOCKING AS REQUIRED. CONFIRM EXACT POWER REQUIREMENTS WITH TENANT. 3'-0" U.C. FRIDGE BY TENANT 2'-0" PROVIDE PLASTIC LAMINATE (PL1) END PANEL AT THIS LOCATION. WATER MACHINE BY TENANT 3'-0"PLASTIC LAMINATE (PL1) BASE CABINETS (SEE CASEWORK NOTE 1) 25" DEEP QUARTZ (QZ2) COUNTERTOP WITH 4" HIGH BACK + SIDE SPLASH DOOR SCHEDULE # DIMENSIONS DOOR FRAME HARDWARE REM. 01 R2, R3 02 03 R3, R4 06 R5 07 R3 08 09 10 11 12 13 14 15 16 R1 17 18 19 DOOR SCHEDULE INTERIOR DETAILS A211 GENERAL NOTE: CONTRACTOR TO CONFIRM THAT SINKS NOTED IN ELEVATIONS PROPERLY COORDINATE WITH WIDTH AND DEPTH OF BASE CABINET PRIOR TO ORDERING. 1. PROVIDE A.W.I. CUSTOM GRADE, FLUSH-OVERLAY CABINETS. FABRICATE WITH PLASTIC LAMINATE (AS NOTED IN ELEVATIONS) COVERED M.D.O. BOARD WITH MOCKETT DP3B-4 PULLS, FINISH: MATTE BLACK. COORDINATE WITH ELEVATIONS FOR QUANTITIES. - AT DRINK + GATHER PROVIDE: 25" DEEP COUNTERTOPS 24" DEEP BASE CABINETS 1112" DEEP (INTERIOR CLEAR DIMENSION) UPPER CABINETS - 4" BASE AT CABINETS TO BE VINYL BASE AS SPECIFIED, UNLESS NOTED OTHERWISE. CASEWORK NOTES CL CLOSER CH COAT HOOK CR CARD READER BY TENANT (N.I.C.) DB DEADBOLT DL DUMMY LEVER EL ELECTROMAGNETIC LOCK (PER IBC 2012) ES ELECTRIC STRIKE BY TENANT (N.I.C.) H HOLD OPEN KP KICK PLATE KS KICK STOP OL OFFICE LOCKSET PH PANIC HARDWARE PL PRIVACY LOCKSET - ASSA ABLOY SARGENT 65 PRIVACYBATH/BEDROOM NON-KEYED MORTISE LOCK WITH OCCUPANCY INDICATOR WITH EMERGENCY RELEASE. PP PUSH/PULL PS PASSAGE LATCHSET PV PIVOT HINGE RL ROLLER LATCHES SL STOREROOM LOCKSET TS TOP STRIKES HARDWARE LEGEND DESCRIPTIONDATE ISSUE 06.12.20 REVIEW SET 06.29.20 UPDATED SET 09.09.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 07.29.20 EH PLAN UPDATE 08.12.20 EH CLG UPDATES2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032EHEH 2019.288 1ST FLOOR 1 DOOR/FRAME TYPES 0 2' 4'1' ELEVATION - WELCOME 101 A211 1 R1. FINISH TENANT SIDE OF DOOR AND FRAME TO MATCH SUITE STANDARD STAIN COLOR. FINISH CORRIDOR SIDE OF DOOR AND FRAME TO MATCH BUILDING STANDARD STAIN COLOR IN COMMON CORRIDOR. R2. CAP ENDS AND HEADER OF DRYWALL WRAPPED OPENING WITH ALUMINUM CASING. R3. PULLS TO BE ROCKWOOD 20" RM4020-US32D WITH CLEAR COATED HICKORY WOOD AND BACK TO BACK MOUNTING. R4. PROVIDE FRAMELESS GLASS CORNER AT THIS LOCATION; REFER TO FRAME TYPE F5 FOR DIMENSIONS. R5. INTENT IS TO REMOVE (4) SECTIONS OF EXISTING STOREFRONT WINDOW SYSTEM AND TO PROVIDE NEW SET OF LOCKABLE, COMMERCIAL GRADE SLIDING DOORS WITH SCREENS. SYSTEM MUST INTEGRATE AS CLOSELY AS POSSIBLE WITH EXISTING STOREFRONT. PROVIDE SUBMITTAL TO SDI FOR APPROVAL. IF STRUCTURAL PLANS ARE REQUIRED, TO BE COMPLETED BY OTHERS. REMARKS DOOR/FRAME NOTES 1. REUSE DOORS FROM DECONSTRUCTION WHERE POSSIBLE; TOUCH UP EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS TO MATCH EXISTING. PRE-MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. 2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED. 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN. 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: · 7'-0" HT. TO HAVE 3 HINGES · GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES · FINISH TO MATCH HARDWARE SET 8. PROVIDE (1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE BLOCKING BEHIND WALL STOP. TYPE MATERIAL FINISH TYPE MATERIAL FINISH 3'-0"x9'-0" D3 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING EL, CR, CL, PP 3'-0"x8'-0"x13 4" D2 SOLID CORE BIRCH VNR. MASONITE COCOA BEAN F3 TIMELY BLACK PS 0 2' 4'1' ELEVATION - DRINK + GATHER 105 A211 2 0 2' 4'1' ELEVATION - DRINK + GATHER 105 A211 3 0 2' 4'1' ELEVATION - DRINK + GATHER 105 A211 4 0 2' 4'1' ELEVATION - DRINK + GATHER 105 A211 5 3'-0"x9'-0" D4 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING PP, CL 3'-0"x9'-0" D5 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING PP, CL 3'-0"x8'-0"x13 4" D2 SOLID CORE BIRCH VNR. MASONITE COCOA BEAN F4 TIMELY BLACK PS 3'-0"x8'-0"x13 4" D2 SOLID CORE BIRCH VNR. MASONITE COCOA BEAN F4 TIMELY BLACK PS 3'-0"x8'-0"x13 4" D2 SOLID CORE BIRCH VNR. MASONITE COCOA BEAN F4 TIMELY BLACK PS 3'-0"x8'-0"x13 4" D2 SOLID CORE BIRCH VNR. MASONITE COCOA BEAN F4 TIMELY BLACK PS 3'-0"x8'-0"x13 4" D2 SOLID CORE BIRCH VNR. MASONITE COCOA BEAN F4 TIMELY BLACK PS 3'-0"x8'-0"x13 4" D2 SOLID CORE BIRCH VNR. MASONITE COCOA BEAN F2 TIMELY BLACK PS 3'-0"x8'-0"x13 4" D2 SOLID CORE BIRCH VNR. MASONITE COCOA BEAN F3 TIMELY BLACK PS 3'-0"x8'-0"x13 4" D2 SOLID CORE BIRCH VNR. MASONITE COCOA BEAN F2 TIMELY BLACK PS SL, CL3'-0"x8'-0"x13 4" D1 SOLID CORE BIRCH VNR. MASONITE COCOA BEAN F1 TIMELY BLACK --NOT USED -- -- -- -- -- -- PL, CL, CH3'-0"x8'-0"x13 4" D1 SOLID CORE BIRCH VNR. MASONITE COCOA BEAN F1 TIMELY BLACK EXISTING -- -- -- -- -- -- -- SEE REMARK -- -- -- -- -- -- -- 0 2' 4'1' ELEVATION - ENTRY 101 A211 6 1 DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20 200 CFM 200 CFM 110 CFM 110 CFM 125 CFM 100 CFM 175 CFM 265 CFM 265 CFM 210 CFM100 CFM100 CFM 225 CFM CEF-1 CEF-2 350 CFM 350 CFM 140 CFM 180 CFM 180 CFM 180 CFM 180 CFM FPB-2 FPB-1 FPB-3 1 1 110 CFM 180 CFM 2 2 2 2 2 3 SR-2 SR-2 SR-1 SR-1 SR-1 SR-1 SR-2 SR-2 3 33 3 3 44 44 333 5157 East 64th StreetIndianapolis, IN 46220317-879-8200www.enviro-max.netTRUEBLOOD REALTYHVAC PLAN SCALE: 1/4"=1'-0"NORTH PLAN NOTES: 1 2 GENERAL NOTES: 3 4 M101 DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20 +60"+60"+42"GFCI+44"GFCIJ JJJJJ +42" GFCI +60" +60"DED+60"+60"+60" +60"+60" +60"+60"+60"+60" +60"+60" +60" +60" +60" +60" +60" +60" +60" +44"GFCI +72" +72"TVU.C. REFRIG U.C. KEG TV321123CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NO DESCCATCODEPLCLEADTIM E PRICEFINISHPSON CAPPN CAPPD CAPMG CAPMC CAPGC CAPQ T CAPPL PSPNPSECPSMCPSQTPSUT1PRO D_NODESC CATCO DE PLCLEADTIMEPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM CPSQ TPSU T1PR OD _NODESCCATCO D EPLCLEADT IM EPR I C EFINISHPSO N CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM C PSQTPSUT1PRO D_ NO DESCCATCO DE PLCLEADT I M E PRIC E FINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATC ODEPLCLEADTIMEPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEADTIM EPRICEFINISHPSONCAPPNCAPPDCAPMGCAPM CCAPGCCAPQTCAPP LPSPNPSECPSMCPSQTPSUT1PRO D _N ODESCCATCODEPLCLEADT IM EPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM CPSQ TPSU T1PR OD _NODESCCATCO D EPLCLEADT IM EPR IC EFINISHPSO N CAP P N CAP P D CAP M G CAP M C CAP G C CAP Q T CAP P L PSP N PSE C PSM C PSQ T PRO D _ N O DESC CAT C O D E PLCLEA D T I M E PRIC E FINI S H PSO N CAP P N CAP P D CAP M G CAP M C CAP G C CAP Q T CAP P L PSP N PSE C PSM C PSQ T PSU T 1 PRO D _ N O DESC CAT C O D E PLCLEA D T I M E PRIC E FINI S H PSO NCAPPNCAPPDCAPMGCAPMCCAPGCCAPQ TCAPPL PSPN PSEC PSMC PSQT PSUT1 PRO D_NODESC CATCO DEPLC LEADTIME PRICE FINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NO DESCCATC ODE PLCLEADTIMEPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM CPSQ TPSU T1PR OD _NODESCCATCO D EPLCLEADT IM EPR I C EFINISHPSO N CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM C PSQTPSUT1PRO D_ NO DESCCATCO DE PLCLEADT I M E PRIC E FINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQ TCAPPLPSPNPSECPSMCPSQTPSUT1PRO D_NODESCCATCO DEPLCLEADTIMEPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATC ODEPLCLEADTIMEPRICEFINISHPSON CAPPNCAPPDCAPMGCAPM CCAPGCCAPQTCAPP LPSPNPSECPSMCPSQTPSUT1PRO D _N ODESCCATCODEPLCLEADT IM EPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM CPSQ TPSU T1PR OD _NODESCCATCO D EPLCLEADT IM EPR IC EFINISHPSO N CAP P N CAP P D CAP M G CAP M C CAP G C CAP Q T CAP P L PSP N PSE C PSM C PSQ T PRO D _ N O DESC CAT C O D E PLCLEA D T I M E PRIC E FINI S H PSO N CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEADTIM EPRICEFINISHPSONCAP PN CAP PD CAP MG CAP MC CAP GC CAP QT CAP PL PSPNPSECPSM C PSQ T PSU T 1 PR O D_NODESC CATCO DE PLCLEADTIMEPR IC E FINISHPSO N CAP PN CAP PD CAP MG CAP MC CAP GC CAP QT CAP PL PSPNPSE C PSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEAD TI M E PRIC E FINISHPSON CAPP N CAPP D CAPM G CAPM C CAPG C CAPQ T CAPP L PSPNPSECPSMCPSQTPROD _ N O DESCCATC O D E PLCLEADT I M E PRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEADTIMEPRICEFINISHPSONCAP PN CAP PD CAP MG CAP MC CAP GC CAP QT CAP PL PSPNPSECPSM C PSQ T PSU T 1 PR O D_NODESC CATCO DE PLCLEADTIMEPR IC E FINISHPSO N CAP PN CAP PD CAP MG CAP MC CAP GC CAP QT CAP PL PSPNPSE C PSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEAD TI M E PRIC E FINISHPSON CAPP N CAPP D CAPM G CAPM C CAPG C CAPQ T CAPP L PSPNPSECPSMCPSQTPROD _ N O DESCCATC O D E PLCLEADT I M E PRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEADTIMEPRICEFINISHPSONFEOL1-1 OL1-3 OL1-5 OL1-7 OL1-9 OL1-11 OL1-13 OL1-15 OL1-17 OL1-21 OL1-23 OL1-25 OL1-27OL1-29 OL1-19 RTU-1 DGFCI RTU-1 DGFCI OH1 OH1 OH1 OH1 OH1 VAV 1 VAV 2 VAV 3 ELNELN ELNELNELNELN TV U.C. REFRIG U.C. KEG TV321123CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEADTIM EPRICEFINISHPSON CAPPN CAPPD CAPMG CAPMC CAPGC CAPQ TCAPPL PSPN PSEC PSMC PSQT PSUT1 PRO D_NODESC CATCO DEPLC LEADTIME PRICE FINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM CPSQ TPSU T1PR OD _NODESCCATCO D EPLCLEADT IM EPR I C EFINISHPSO N CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM C PSQTPSUT1PRO D_ NO DESCCATCO DE PLCLEADT I M E PRIC E FINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATC ODEPLCLEADTIMEPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEADTIM EPRICEFINISHPSONCAPPNCAPPDCAPMGCAPM CCAPGCCAPQTCAPP LPSPNPSECPSMCPSQTPSUT1PRO D _N ODESCCATCODEPLCLEADT IM EPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM CPSQ TPSU T1PR OD _NODESCCATCO D EPLCLEADT IM EPR IC EFINISHPSO N CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPROD_NODESCCATCODEPLCLEADTIM EPRICEFINISHPSONCAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEADTIM EPRICEFINISHPSONCAPPNCAPPDCAPMGCAPMCCAPGCCAPQ T CAPPLPSPNPSECPSMCPSQTPSUT1PRO D_NODESC CATCO DE PLCLEADTIMEPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEADTIM EPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM CPSQ TPSU T1PR OD _NODESCCATCO D EPLCLEADT IM EPR I C EFINISHPSO N CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM C PSQTPSUT1PRO D_ NO DESCCATCO DE PLCLEADT I M E PRIC E FINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQ TCAPPLPSPNPSECPSMCPSQTPSUT1PRO D_NODESCCATCO DEPLCLEADTIMEPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATC ODEPLCLEADTIMEPRICEFINISHPSONCAPPNCAPPDCAPMGCAPM CCAPGCCAPQTCAPP LPSPNPSECPSMCPSQTPSUT1PRO D _N ODESCCATCODEPLCLEADT IM EPRICEFINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSM CPSQ TPSU T1PR OD _NODESCCATCO D EPLCLEADT IM EPR IC EFINISHPSO N CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPROD_NODESCCATCODEPLCLEADTIM EPRICEFINISHPSONCAP P N CAP P D CAP M G CAP M C CAP G C CAP Q T CAP P L PSP N PSE C PSM C PSQ T PSU T 1 PRO D _ N O DESC CAT C O D E PLCLEA D T I M E PRIC E FINI S H PSO N CAP PN CAP PD CAP MG CAP MC CAP GC CAP QT CAP PL PSPNPSECPSM C PSQ T PSU T 1 PR O D_NODESC CATCO DE PLCLEADTIMEPR IC E FINISHPSO N CAP PN CAP PD CAP MG CAP MC CAP GC CAP QT CAP PL PSPNPSE C PSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEAD TI M E PRIC E FINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPROD_NODESCCATCODEPLCLEADTIMEPRICEFINISHPSONCAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEADTIMEPRICEFINISHPSONCAP PN CAP PD CAP MG CAP MC CAP GC CAP QT CAP PL PSPNPSECPSM C PSQ T PSU T 1 PR O D_NODESC CATCO DE PLCLEADTIMEPR IC E FINISHPSO N CAP PN CAP PD CAP MG CAP MC CAP GC CAP QT CAP PL PSPNPSE C PSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEAD TI M E PRIC E FINISHPSON CAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPROD_NODESCCATCODEPLCLEADTIMEPRICEFINISHPSONCAPPNCAPPDCAPMGCAPMCCAPGCCAPQTCAPPLPSPNPSECPSMCPSQTPSUT1PROD_NODESCCATCODEPLCLEADTIMEPRICEFINISHPSONFEOS OS OS OS OS OS OS OS OS OS OS OS OS L4 L4 L4L4 L3 L3 L3 L3 L3 L3L3L3 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1L1 L1 L1 L1 L1 L1 L1 L1L1 L1 L1 L2 L2 L2 L2 L2 L2 L2 L2 L2 EX EX EX EX OS OS OFFICE POWER PLAN 1/8" = 1'-0" K.VAUGHNL.SHEETZ OFFICE LIGHTING PLAN 1/8" = 1'-0" E-100 Luminaire Schedule Symbol Qty Label Arrangement Total Lamp Lumens LLF Description 24 L1 SINGLE 4509 0.900 2"X4" COLUMBIA LIGHTING 3500K 132' L2 SINGLE -- FINELITE HP-2 I/D 6 ELN SINGLE EXIT/EMERGENCY (R.C.) 4 EX SINGLE REMOTE HEAD 8 L3 SINGLE TROY ORIGAMI PENDANT 4 L4 SINGLE 888 0.900 6" LED CAN; 3500K Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min Conf Rm Illuminance Fc 71.31 92.8 46.5 1.53 2.00 Typ Rm Illuminance Fc 52.85 75.3 34.4 1.54 2.19 -- -- -- -- -- -- -- ELN DESCRIPTIONDATE ISSUE REVISIONS DESCRIPTIONMARKDATEDB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER DRAWN BYPROJ. MGR N Indianapolis - Cincinnati - Columbus, OH 2350 North Shadeland Avenue Phone: (317) 543-3460 Electrical & Mechanical Indianapolis, IN 46219-1736 Fax: (317) 543-3476TRUEBLOODREALTY MIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032DESCRIPTIONDATE ISSUE REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER DRAWN BYPROJ. MGR Indianapolis - Cincinnati - Columbus, OH 2350 North Shadeland Avenue Phone: (317) 543-3460 Electrical & Mechanical Indianapolis, IN 46219-1736 Fax: (317) 543-3476TRUEBLOODREALTY MIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032OVERALL POWER AND LIGHTING 20019 TYP. HORN STROBE/PULL STATION INSTALL AT MAN DOOR NOT TO SCALED.4 34" 48" WITHIN 5' OF DOORWAY HORN STROBE PULL STATION PROVIDE SAFETY CABLE AT EACH CORNER FIXTURE HOUSING SECURE EARTHQUAKE CLIPS TO CEILING GRID AT EACH SIDE 7/8"Ø TOP VIEW 4"x1-1/2" BOX ADDITIONAL ROD OR WIRE SUPPORT CEILING GRID LAY-IN CEILING EXIT JUNCTION BOX FLEXIBLE CONDUIT SUPPORT BRACKET STEEL JOIST OR BEAMS END VIEW CEILING SUPPORT WIRE CL CL 23 3/4" 4" OCTAGONAL JUNCTION BOX (AT LEAST 1.5" DEEP). DO NOT INSTALL SENSOR WITHOUT JUNCTION BOX. DEPLUGGABLE TERMINAL SENSOR (2) MOUNTING SCREWS FRONT COVER CEILING5 3/8"1"1/2" 1/2" TYP. DROP IN 2X4 FIXTURE NOT TO SCALE D.1 CEILING MOUNTED EXIT FIXTURE NOT TO SCALED.2 CEILING MOUNTED OCCUPANCY SENSOR NOT TO SCALE D.3 N.5 VERIFY EXISTING CIRCUITRY N.1 TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. N.2 ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL EXISTING AND NEW DEVICES + FACE PLATES TO BE WHITE; REPLACE AS REQUIRED. N.3 REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. N.4 ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. ELECTRICAL LEGEND POWER OUTLET, DUPLEX NEW CONSTRUCTION J J B O POWER OUTLET, QUADRUPLEX JUNCTION BOX CEILING MOUNTED JUNCTION BOX BOX, BLANK COVER PLATE BOX, OPEN FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED J FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42" HEIGHT OF ELECTRICAL OR DATA DEVICE EXISTING TO REMAIN POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX CEILING MOUNTED JUNCTION BOX BOX, BLANK COVER PLATE BOX, OPEN POWER AND DATA POLE FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED DATA/COMMUNICATION OUTLET PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE CONNECTION. POWER POLE BY OTHERS GENERAL ELEC. NOTESELECTRICAL PLAN NOTES PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. COORDINATE POWER REQUIREMENTS IN THIS ROOM WITH TENANT. PROVIDE DEDICATED RECEPTACLES AS REQUIRED. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. PROVIDE POWER FOR TENANT'S UNDERCOUNTER REFRIGERATOR AND/OR KEG. PROVIDE POWER FOR TENANT'S OVERHEAD PROJECTOR + AUTOMATIC PROJECTOR SCREEN IN THIS AREA. FINAL DETAILS AND LOCATION TO BE COORDINATED WITH TENANT. PROVIDE DIRECT HDMI/VGA CONDUIT CONNECTION FROM FLOOR CORE POKE THRU DEVICE TO WALL MOUNTED MONITOR(S). PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND/OR JUNCTION BOX + DATA. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. OUTLETS AT THIS LOCATION TO BE INSTALLED HORIZONTALLY. ALL ABOVE COUNTER OUTLETS ARE FOR DEDICATED APPLIANCE USE ONLY. CONVENIENCE OUTLETS ARE LOCATED ELSEWHERE IN ROOM. PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND/OR JUNCTION BOX + DATA. INTENT IS FOR POKE THRU DEVICE AT THIS LOCATION TO BE COMPLETELY FLUSH WITH ADJACENT FLOOR AND CONCEAL POWER AND DATA BELOW. COORDINATE WITH TENANT + TENANT'S FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. AT EXISTING STEEL COLUMN, COORDINATE WITH TENANT ON EXACT TV SPECIFICATIONS AND PROVIDE APPROPRIATE POWER + DATA, CONDUIT, AND J-BOX AS REQUIRED FOR TELEVISION. COORDINATE MOUNTING HEIGHT WITH TENANT. PROVIDE POWER AS REQURED FOR TENANT'S WATER MACHINE AND UNDERCOUNTER REFRIGERATOR AT THIS LOCATION. HORN/STROBE COMBO PULL STATION D DISCONNECT AREA NOT IN CONTRACT AREA OF WORK AREA NOT IN CONTRACT AREA OF WORK DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20 TVTVFEREC 1/2" DCW DOWN 1/2" DCW UNDERGROUND 1/2" DCW UNDERGROUND EXISTING 4" CO 2" SAN2"SAN 2"SAN 4"SAN LAV-1H WC-1H SK-1 2" FD 2" FD Indianapolis - Cincinnati - Columbus, OH 2350 North Shadeland Avenue Phone: (317) 543-3460 Indianapolis, IN 46219-1736 Fax: (317) 543-3476 Electrical & Mechanical PDSONEINERN G .SI No. I S TER E S GRE D D I A N AI ESTATE OF 20158 NRPJAMOF NALIO SS M E E N 0 2' 4' 8' 16' DESCRIPTIONDATE ISSUE REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 4603220019 1/4" = 1'-0" Checker Author SANITARY P100 1/4" = 1'-0"1 1-SANITARY 1 9.3.20 GW STATE SUBMIT 9/4/20 STATE SUBMIT DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20 TVTVFEREC 1/2" DCW DOWN CONNECT TO EXISTING DOMESTIC WATER 3/4" DCW INSTA HOT LAV-1H WC-1H 3/4"DCW 2" V 3/4"DCW 2" V 2" V 3/4" DCW TO INSTA HOTINSTA HOT 3/4" DCW DOWN FOR ICE MAKER AND COFFE SK-1 EXISTING 4" CO 2" FD 2" FD TO EXISTING VENT 3/4"DCW DOWN TO INSTA HOT 3/4" DCW 2" V Indianapolis - Cincinnati - Columbus, OH 2350 North Shadeland Avenue Phone: (317) 543-3460 Indianapolis, IN 46219-1736 Fax: (317) 543-3476 Electrical & Mechanical PDSONEINERN G .SI No. I S TER E S GRE D D I A N AI ESTATE OF 20158 NRPJAMOF NALIO SS M E E N 0 2' 4' 8' 16' DESCRIPTIONDATE ISSUE REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 4603220019 1/4" = 1'-0" BD GOW DOMESTIC P200 1/4" = 1'-0"1 2-DOMESTIC 9/4/20 STATE SUBMIT 1 9.3.20 GW STATE SUBMIT DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20 INSTA HOT LAV-1H 2" SAN 2" SAN FD-1 FD-1 WC-1H 2" V CONNECT TO EXISTING VENT LINE 2" SAN 4" SAN EXISTING 4" CO 3" SAN 2" V 2" SAN INSTA HOT SK-1 2" V 1/2" DCW UNDER GROUND 3/4" DCW FOR ICE MAKER AND COFFE MAKER 3/4" DCW CONNECT TO EXISTING 3/4" DCW 1/2" DCW DOWN 3/4" DCW 2" V 3/4" DCW 1/2" DCW UNDERGROUND Indianapolis - Cincinnati - Columbus, OH 2350 North Shadeland Avenue Phone: (317) 543-3460 Indianapolis, IN 46219-1736 Fax: (317) 543-3476 Electrical & Mechanical PDSONEINERN G .SI No. I S TER E S GRE D D I A N AI ESTATE OF 20158 NRPJAMOF NALIO SS M E E N 0 2' 4' 8' 16' DESCRIPTIONDATE ISSUE REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 4603220019 BD GOW SANITARY AND DOMESTIC ISOMETRIC DIAGRAM P300 1 9.3.20 GW STATE SUBMIT 9/4/20 STATE SUBMIT 1 SANITARY AND DOMESTIC ISOMETRIC DIAGRAM DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20