HomeMy WebLinkAboutA111 - 1st Floor Deconstruction & Architectural Floor PlanFEOFFICE
113
OFFICE
114
OFFICE
115
OFFICE
119
OFFICE
118
OFFICE
117
OPEN OFFICE
116
COMPETE
106
SERVER/STG
110
RESTROOM
112
WELCOME
101
CONFERENCE
103
CONFERENCE
107
OFFICE
109
DRINK +
GATHER
105
OFFICE
108
OFFICE
102
OPEN OFFICE
104
11'-5"10'-6" 10'-6"8'-5"3'-10" 9'-71
2"
10'-101
2"10'-103
4" 11'-134"11'-134" 9'-734"11'-7"
10'-43
4"14'-3"4'-0" 8'-0"
5'-91
2"7'-5"8'-934"10'-81
2"
5'-0"
CLEAR
FE13'-7"WALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
TYPICAL WALL TYPE
METAL STUD
EXISTING WINDOW
MULLION
EQUAL
& ARCHITECTURAL
FLOOR PLAN
A111
ARCHITECTURAL PLAN AREA NOT IN CONTRACT
AREA OF WORK
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
WINDOW / SIDELIGHTWINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
DEMISING WALL TO DECK WITH INSULATION
358" METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W1
W2 PARTIAL HEIGHT WALL
358 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO 3'-4 12";
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED.
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
DESCRIPTIONDATE
ISSUE
06.12.20 REVIEW SET
06.29.20 UPDATED SET
09.09.20 PERMIT SET
REVISIONS
DESCRIPTIONMARK DATE DB
07.29.20 EH PLAN UPDATE
08.12.20 EH CLG UPDATES2
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032EHEH
2019.288
1ST FLOOR
N
1
0 2' 4' 8' 16'
DECONSTRUCTION PLAN
REMOVE PORTION OF EXISTING WINDOW IN PREPARATION FOR
NEW SLIDING DOOR SYSTEM. REFER TO DOOR SCHEDULE.
COORDINATE STORAGE OF REMOVED WINDOW WITH PROPERTY
MANAGEMENT.
RELOCATE EXISTING BUILDING EQUIPMENT FROM THIS LOCATION
TO NEW; REFER TO ARCHITECTURAL PLAN.
CONTRACTOR TO CONFIRM PURPOSE OF EXISTING POST AT THIS
LOCATION. RELOCATE OR RECONFIGURE AS REQUIRED.
RELOCATE EXISTING FIRE EXTINGUISHER AND CABINET - REFER TO
ARCHITECTURAL PLAN.
DECON. PLAN NOTES
ELECTRIC OUTLET(S)
DATA OR
COMMUNICATION
OUTLET
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT
WALL
DOOR AND FRAME
CEILING GRID AND
TILES, 2'x4'
SUPPLY AIR DIFFUSERS
LIGHT FIXTURE,
FLUORESCENT, 2'x4'
LIGHT FIXTURE, CAN
LIGHT SWITCH
LIGHT FIXTURE,
FLUORESCENT, 2'x2'
WINDOW / SIDELIGHT
CEILING GRID AND
TILES, 2'x2'
LIGHT FIXTURE, TRACK
LIGHT FIXTURE, SCONCE
LIGHT FIXTURE,
PENDANT
EXIT LIGHT
DECONSTRUCTION LEGEND
AREA NOT IN CONTRACT
AREA OF WORK
DECONSTRUCTION
ARCH. GENERAL NOTES
PARTIAL HEIGHT WALLPARTIAL HEIGHT WALL
ARCH. PLAN NOTES
TYP.
A111
1
0 2' 4' 8' 16'
NOT TO SCALE
WALL AT MULLION DETAIL
A111
1
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH.
REFER TO MANUFACTURER RECOMMENDATIONS.
3. ALL STEEL, CROSSBRACING, AND COLUMNS TO REMAIN EXPOSED UNLESS NOTED OTHERWISE. REFER TO FINISH PLAN FOR MORE
INFORMATION.
4. PROVIDE BUILDING STANDARD MANUALLY OPERATED WINDOW SHADES AT ALL EXTERIOR WINDOWS. CONFIRM SPEC AND COLOR OF
SHADES WITH TENANT.
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW
WALLS ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x8'x3
4", PAINTED WITH
FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH.
VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION.
CONTRACTOR TO INSTALL SALVAGED FIRE EXTINGUISHER AND
CABINET AT THIS LOCATION. ALL FIRE EXTINGUISHERS ARE TO
BE INSTALLED ACCORDING TO NFPA 10. PROVIDE NEW AS
REQUIRED.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
NEW WALL CONSTRUCTION TO MATCH ADJACENT COMMON
CORRIDOR WALL CONSTRUCTION.
WRAP COLUMN AS TIGHTLY AS POSSIBLE WITH NEW WALL
CONSTRUCTION.
IN AREA WITH EXPOSED CEILING DECK, ENSURE THAT DRYWALL
ON ALL NEW AND EXISTING WALLS EXTENDS TO DECK;
PROVIDE NEW DRYWALL AS REQUIRED. TRANSITION TO BE A
CLEAN HORIZONTAL LINE FINISHED SUCH THAT CONTRASTING
PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO
CEILING LINE. SEE REFLECTED CEILING PLAN FOR EXACT AREA
OF EXPOSED CEILING.
NOT USED.
PROVIDE 1
2" TEMPERED BUTT-GLAZED GLASS FRAMELESS
CORNER WINDOW AT THIS LOCATION. REFER TO DOOR
SCHEDULE AND FRAME TYPE FOR MORE INFORMATION.
COORDINATE ALL REQUIREMENTS FOR TENANT'S KEG AT THIS
LOCATION.
EMERGENCY LIGHT
1. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T111.
2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE
CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR
SALVAGED FOR LANLORD. FOR ALL ITEMS DETERMINED FOR
REMOVAL, REFER TO THE RECYCLING INSTRUCTIONS.
3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN
ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW
FINISHES AS REQUIRED.
4. SALVAGE REMOVED LIGHT FIXTURES AND HVAC DIFFUSERS FOR
REUSE. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION.
DECON. GENERAL NOTES
RECYCLING INSTRUCTIONS
METALS ONLY RECYCLING BIN:
1. CONTACT WASTE HAULER TO ORDER TRASH DUMPSTER(S) AS
REQUIRED AND (1) "METALS ONLY" RECYCLING BIN FOR THE
DEMOLITION PORTION OF PROJECT ONLY. SIZE OF "METALS ONLY"
BIN IS DETERMINED BY THE AMOUNT OF DEMOLITION (10-40 YARD
CONTAINERS AVAILABLE).
2. DRYWALL MUST BE REMOVED FROM ALL METAL STUDS PRIOR TO
PLACING IN "METALS ONLY" BIN. ANY ADDED LABOR COST WILL BE
COVERED BY METAL CREDITS RECEIVED FROM WASTE HAULER.
3. WASTE HAULER WILL APPLY CREDIT FOR METALS OBTAINED IN
"METALS ONLY" BIN TOWARDS CONTRACTORS OVERALL INVOICE.
4. DATA/DIVERSION REPORTS ARE NOT REQUIRED NOR ANY LEED
PROCESSES OR PAPERWORK.
APPROVED METAL ITEMS:
5. METAL STUDS, DOOR FRAMES, DOOR HARDWARE, CEILING GRID,
LIGHT BOX FIXTURES, METAL CABINETS, METAL PLUMBING FIXTURES,
ELECTRICAL AND DATA WIRING/CONDUIT, HVAC COMPONENTS,
AND ELECTRICAL/DATA/SWITCH BOXES
CONTACT EMILY HILLYER (317) 762-7840 AT SCHOTT DESIGN FOR ANY
QUESTIONS REGARDING THE RECYCLING PROCESSES.
W2
W2
W2
A141
4
SUPPORT COUNTER AS REQUIRED WITH CENTERLINE BRACKET'S
FRONT MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS
WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER
VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL
BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL.
COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL
INSTALLATION AS NEEDED. DESIGN INTENT IS FOR VERTICAL
SUPPORT TO BE CONCEALED BY DRYWALL. REFER TO
ELEVATION AND SECTION FOR MORE INFORMATION.
AT EXISTING STEEL COLUMN, COORDINATE WITH TENANT ON
EXACT TV SPECIFICATIONS AND PROVIDE APPROPRIATE
CEILING MOUNTED SUPPORT + BRACKET AS REQUIRED FOR
TELEVISION. COORDINATE MOUNTING HEIGHT WITH TENANT.
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY
WASTE AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
PROVIDE WATER LINE FOR TENANT'S COFFEE MAKER AND
WATER MACHINE. CONFIRM FINAL LOCATIONS WITH TENANT.
PROVIDE COLD WATER SUPPLY AND WATER LINES AS
REQUIRED FOR NEW TOILET.
RELOCATE EXISTING BUILDING EQUIPMENT TO THIS LOCATION.
A211
1
A211
2
A211
2
SIM
A211
3,4,5
A211
6
1
1