Loading...
HomeMy WebLinkAboutA111 - 1st Floor Deconstruction & Architectural Floor PlanFEOFFICE 113 OFFICE 114 OFFICE 115 OFFICE 119 OFFICE 118 OFFICE 117 OPEN OFFICE 116 COMPETE 106 SERVER/STG 110 RESTROOM 112 WELCOME 101 CONFERENCE 103 CONFERENCE 107 OFFICE 109 DRINK + GATHER 105 OFFICE 108 OFFICE 102 OPEN OFFICE 104 11'-5"10'-6" 10'-6"8'-5"3'-10" 9'-71 2" 10'-101 2"10'-103 4" 11'-134"11'-134" 9'-734"11'-7" 10'-43 4"14'-3"4'-0" 8'-0" 5'-91 2"7'-5"8'-934"10'-81 2" 5'-0" CLEAR FE13'-7"WALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT TYPICAL WALL TYPE METAL STUD EXISTING WINDOW MULLION EQUAL & ARCHITECTURAL FLOOR PLAN A111 ARCHITECTURAL PLAN AREA NOT IN CONTRACT AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL WINDOW / SIDELIGHTWINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL DEMISING WALL TO DECK WITH INSULATION 358" METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W1 W2 PARTIAL HEIGHT WALL 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO 3'-4 12"; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED. WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DESCRIPTIONDATE ISSUE 06.12.20 REVIEW SET 06.29.20 UPDATED SET 09.09.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 07.29.20 EH PLAN UPDATE 08.12.20 EH CLG UPDATES2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032EHEH 2019.288 1ST FLOOR N 1 0 2' 4' 8' 16' DECONSTRUCTION PLAN REMOVE PORTION OF EXISTING WINDOW IN PREPARATION FOR NEW SLIDING DOOR SYSTEM. REFER TO DOOR SCHEDULE. COORDINATE STORAGE OF REMOVED WINDOW WITH PROPERTY MANAGEMENT. RELOCATE EXISTING BUILDING EQUIPMENT FROM THIS LOCATION TO NEW; REFER TO ARCHITECTURAL PLAN. CONTRACTOR TO CONFIRM PURPOSE OF EXISTING POST AT THIS LOCATION. RELOCATE OR RECONFIGURE AS REQUIRED. RELOCATE EXISTING FIRE EXTINGUISHER AND CABINET - REFER TO ARCHITECTURAL PLAN. DECON. PLAN NOTES ELECTRIC OUTLET(S) DATA OR COMMUNICATION OUTLET EXISTING TO BE REMOVED EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WALL DOOR AND FRAME CEILING GRID AND TILES, 2'x4' SUPPLY AIR DIFFUSERS LIGHT FIXTURE, FLUORESCENT, 2'x4' LIGHT FIXTURE, CAN LIGHT SWITCH LIGHT FIXTURE, FLUORESCENT, 2'x2' WINDOW / SIDELIGHT CEILING GRID AND TILES, 2'x2' LIGHT FIXTURE, TRACK LIGHT FIXTURE, SCONCE LIGHT FIXTURE, PENDANT EXIT LIGHT DECONSTRUCTION LEGEND AREA NOT IN CONTRACT AREA OF WORK DECONSTRUCTION ARCH. GENERAL NOTES PARTIAL HEIGHT WALLPARTIAL HEIGHT WALL ARCH. PLAN NOTES TYP. A111 1 0 2' 4' 8' 16' NOT TO SCALE WALL AT MULLION DETAIL A111 1 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. ALL STEEL, CROSSBRACING, AND COLUMNS TO REMAIN EXPOSED UNLESS NOTED OTHERWISE. REFER TO FINISH PLAN FOR MORE INFORMATION. 4. PROVIDE BUILDING STANDARD MANUALLY OPERATED WINDOW SHADES AT ALL EXTERIOR WINDOWS. CONFIRM SPEC AND COLOR OF SHADES WITH TENANT. ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. CONTRACTOR TO INSTALL SALVAGED FIRE EXTINGUISHER AND CABINET AT THIS LOCATION. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE NEW AS REQUIRED. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. NEW WALL CONSTRUCTION TO MATCH ADJACENT COMMON CORRIDOR WALL CONSTRUCTION. WRAP COLUMN AS TIGHTLY AS POSSIBLE WITH NEW WALL CONSTRUCTION. IN AREA WITH EXPOSED CEILING DECK, ENSURE THAT DRYWALL ON ALL NEW AND EXISTING WALLS EXTENDS TO DECK; PROVIDE NEW DRYWALL AS REQUIRED. TRANSITION TO BE A CLEAN HORIZONTAL LINE FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. SEE REFLECTED CEILING PLAN FOR EXACT AREA OF EXPOSED CEILING. NOT USED. PROVIDE 1 2" TEMPERED BUTT-GLAZED GLASS FRAMELESS CORNER WINDOW AT THIS LOCATION. REFER TO DOOR SCHEDULE AND FRAME TYPE FOR MORE INFORMATION. COORDINATE ALL REQUIREMENTS FOR TENANT'S KEG AT THIS LOCATION. EMERGENCY LIGHT 1. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T111. 2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR SALVAGED FOR LANLORD. FOR ALL ITEMS DETERMINED FOR REMOVAL, REFER TO THE RECYCLING INSTRUCTIONS. 3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. 4. SALVAGE REMOVED LIGHT FIXTURES AND HVAC DIFFUSERS FOR REUSE. SEE REFLECTED CEILING PLAN FOR MORE INFORMATION. DECON. GENERAL NOTES RECYCLING INSTRUCTIONS METALS ONLY RECYCLING BIN: 1. CONTACT WASTE HAULER TO ORDER TRASH DUMPSTER(S) AS REQUIRED AND (1) "METALS ONLY" RECYCLING BIN FOR THE DEMOLITION PORTION OF PROJECT ONLY. SIZE OF "METALS ONLY" BIN IS DETERMINED BY THE AMOUNT OF DEMOLITION (10-40 YARD CONTAINERS AVAILABLE). 2. DRYWALL MUST BE REMOVED FROM ALL METAL STUDS PRIOR TO PLACING IN "METALS ONLY" BIN. ANY ADDED LABOR COST WILL BE COVERED BY METAL CREDITS RECEIVED FROM WASTE HAULER. 3. WASTE HAULER WILL APPLY CREDIT FOR METALS OBTAINED IN "METALS ONLY" BIN TOWARDS CONTRACTORS OVERALL INVOICE. 4. DATA/DIVERSION REPORTS ARE NOT REQUIRED NOR ANY LEED PROCESSES OR PAPERWORK. APPROVED METAL ITEMS: 5. METAL STUDS, DOOR FRAMES, DOOR HARDWARE, CEILING GRID, LIGHT BOX FIXTURES, METAL CABINETS, METAL PLUMBING FIXTURES, ELECTRICAL AND DATA WIRING/CONDUIT, HVAC COMPONENTS, AND ELECTRICAL/DATA/SWITCH BOXES CONTACT EMILY HILLYER (317) 762-7840 AT SCHOTT DESIGN FOR ANY QUESTIONS REGARDING THE RECYCLING PROCESSES. W2 W2 W2 A141 4 SUPPORT COUNTER AS REQUIRED WITH CENTERLINE BRACKET'S FRONT MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. DESIGN INTENT IS FOR VERTICAL SUPPORT TO BE CONCEALED BY DRYWALL. REFER TO ELEVATION AND SECTION FOR MORE INFORMATION. AT EXISTING STEEL COLUMN, COORDINATE WITH TENANT ON EXACT TV SPECIFICATIONS AND PROVIDE APPROPRIATE CEILING MOUNTED SUPPORT + BRACKET AS REQUIRED FOR TELEVISION. COORDINATE MOUNTING HEIGHT WITH TENANT. PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. PROVIDE WATER LINE FOR TENANT'S COFFEE MAKER AND WATER MACHINE. CONFIRM FINAL LOCATIONS WITH TENANT. PROVIDE COLD WATER SUPPLY AND WATER LINES AS REQUIRED FOR NEW TOILET. RELOCATE EXISTING BUILDING EQUIPMENT TO THIS LOCATION. A211 1 A211 2 A211 2 SIM A211 3,4,5 A211 6 1 1 DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20