HomeMy WebLinkAboutA121 - 1st Floor Electrical Plan RCPOFFICE 113 OFFICE 114 OFFICE 115 OFFICE 119 OFFICE 118 OFFICE 117 OPEN OFFICE 116 COMPETE 106 SERVER/STG 110 RESTROOM 112 WELCOME 101 TVCONFERENCE 103 CONFERENCE 107 OFFICE 109 DRINK + GATHER 105 U.C. REFRIG U.C. KEG TV321123OFFICE 108 OFFICE 102 OPEN OFFICE 104 +60"+60"+42"GFCI+44"GFCIJJJJJJ +42" GFCI +60" +60"DED+60"+60"+60" +60"+60" +60"+60"+60"+60" +60"+60" +60" +60" +60" +60" +60" +60" +60" +44"GFCI +72" +72" OFFICE 113 OFFICE 114 OFFICE 115 OFFICE 119 OFFICE 118 OFFICE 117 OPEN OFFICE 116 COMPETE 106 SERVER/STG 110 RESTROOM 112 WELCOME 101 TVCONFERENCE 103 CONFERENCE 107 OFFICE 109 DRINK + GATHER 105 U.C. REFRIG U.C. KEG TV321123OFFICE 108 OFFICE 102 OPEN OFFICE 104 +60"+60"+42"GFCI+44"GFCIJ JJJJJ +42" GFCI +60" +60"DED+60"+60"+60" +60"+60" +60" +60"+60"+60" +60"+60" +60" +60" +60" +60" +60" +60" +60" +44"GFCI +72" +72"SN16'-0" 12'-0" TYP.8'-0"L; 8'-6" AFFELNELNELNELNELNELN SNSNSNSNS N SNSN3SNSNSNSNS NSNSN3 SNSN3SN3SN16'-0" 12'-0" TYP.8'-0"L; 8'-6" AFFELNELNELNELNELNELN SNSNSNSNS N SNSN3SNSNSNSNS NSNSN3 SNSN3SN38'-0"9'-0"REFLECTED CEILING PLAN A121 REFLECTED CEILING PLAN DESCRIPTIONDATE ISSUE 06.12.20 REVIEW SET 06.29.20 UPDATED SET 09.09.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 07.29.20 EH PLAN UPDATE 08.12.20 EH CLG UPDATES2 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TRUEBLOODREALTYMIDTOWN EAST | SUITE 100571 MONON BLVD, CARMEL, IN 46032EHEH 2019.288 1ST FLOOR N 1 0 2' 4' 8' 16' AREA NOT IN CONTRACT AREA OF WORK AREA NOT IN CONTRACT AREA OF WORK ELECTRICAL PLAN NOTES ELECTRICAL PLAN DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, QUADRUPLEX JUNCTION BOX POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX BOX, BLANK COVER PLATE BOX, OPEN BOX, BLANK COVER PLATE BOX, OPEN POWER AND DATA POLE FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL LEGEND CEILING MOUNTED JUNCTION BOX CEILING MOUNTED JUNCTION BOX ELECTRICAL PLAN/ RCP PLAN NOTES GENERAL ELEC. NOTES CONTROL WELCOME 101, OPEN OFFICE 104, COMPETE 106, OPEN OFFICE 116 AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. CLEAN ALL EXPOSED SURFACES; EXISTING SURFACES TO REMAIN AS-IS. PROVIDE RIGID SPIRAL DUCT AND ROUND SUPPLY DIFFUSERS AS REQUIRED IN THIS AREA. INSTALL TENANT'S OVERHEAD PROJECTOR + AUTOMATIC PROJECTOR SCREEN IN THIS AREA. ALL FINAL DETAILS AND LOCATION TO BE COORDINATED WITH TENANT. INSTALL FLOATING CLOUD WITH ARMSTRONG AXIOM TRIM AROUND PERIMETER (6"; WHITE). GRID AND TILE TO BE 2'x2' SUITE STANDARD (REFER TO GENERAL CEILING NOTE 1). HEIGHT TO UNDERSIDE OF CEILING CLOUD TO BE AT 10'-0" AFF. FLOAT CLOUD WITH ALL-THREAD INSTALLED 15" FROM EDGES. PAINT ALL THREAD SAME COLOR AS CEILING DECK. INSTALL MINIMAL QUANTITY OF ALL-THREAD SUPPORTS AS POSSIBLE AND MAKE ALL THREAD SUPPORTS AS VISUALLY UNOBTRUSIVE AS POSSIBLE. CONSULT WITH PHIL CAITO (317.519.2829) FOR FINAL SIZES, SPECIFICATIONS, ETC. NOTE THAT SPRINKLERS MAY BE REQUIRED ABOVE AND BELOW CLOUD. FIRE SPRINKLER CONTRACTOR TO PROVIDE SUBMITTAL OF FINAL LAY-OUT FOR FINAL APPROVAL PRIOR TO INSTALLATION. PROVIDE 4 78" WIDE BULKHEAD AT 8'-10" AFF AT THIS LOCATION. BULKHEAD TO EXTEND TO DECK AND ALIGN WITH ADJACENT WALLS AS SHOWN. INTENT IS FOR CEILING GRID AT 9'-0" TO DIE INTO BULKHEAD AS SHOWN. ALL FACES OF BULKHEAD TO BE PAINTED PT2; FLAT FINISH. PROVIDE DRYWALL CEILING AT 10'-0" AFF THIS LOCATION WITH ARMSTRONG AXIOM TRIM AROUND PERIMETER (6"; WHITE) - REFER TO PLANS FOR DIMENSIONS. INTENT IS FOR DRYWALL CEILING TO ALIGN WITH ADJACENT WALL AS SHOWN. UNDERSIDE OF DRYWALL CEILING TO RECEIVE SPECIALTY FINISH - REFER TO FINISH PLANS. CLEAN ALL EXPOSED SURFACES AND PREPARE FOR DRYFALL PAINT (PT6) AS NOTED ON PLAN PER MANUFACTURER'S RECOMMENDATIONS. PAINT EXISTING EXPOSED STRUCTURAL BEAMS AND CROSSBRACING IN ACCORDANCE WITH NFPA 13 6.3.8. ALL STRUCTURAL BEAMS INTENDED TO BE PAINTED ARE CURRENTLY DARK GRAY; CONFIRM AREAS TO BE PAINTED WITH SDI AS REQUIRED. BASE BID: UNDERSIDE OF DECK TO REMAIN AS-IS AND BE CLEANED AS NEEDED. SEPARATE PRICE: ON UNDERSIDE OF DECK ONLY (NO OTHER CEILING ELEMENTS), PROVIDE K13 ACOUSTICAL CEILING TREATMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND ALL STATE + LOCAL CODES. K13 TO BE PAINTED WITH DRYFALL PAINT (PT5). 0 2' 4' 8' 16' 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL EXISTING AND NEW DEVICES + FACE PLATES TO BE WHITE; REPLACE AS REQUIRED. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. J J B O J +42" PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. COORDINATE POWER REQUIREMENTS IN THIS ROOM WITH TENANT. PROVIDE DEDICATED RECEPTACLES AS REQUIRED. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. PROVIDE POWER FOR TENANT'S UNDERCOUNTER REFRIGERATOR AND/OR KEG. PROVIDE POWER FOR TENANT'S OVERHEAD PROJECTOR + AUTOMATIC PROJECTOR SCREEN IN THIS AREA. FINAL DETAILS AND LOCATION TO BE COORDINATED WITH TENANT. PROVIDE DIRECT HDMI/VGA CONDUIT CONNECTION FROM FLOOR CORE POKE THRU DEVICE TO WALL MOUNTED MONITOR(S). PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND/OR JUNCTION BOX + DATA. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. OUTLETS AT THIS LOCATION TO BE INSTALLED HORIZONTALLY. ALL ABOVE COUNTER OUTLETS ARE FOR DEDICATED APPLIANCE USE ONLY. CONVENIENCE OUTLETS ARE LOCATED ELSEWHERE IN ROOM. PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE CONNECTION. POWER POLE BY OTHERS. LIGHT CIRCUIT LIGHT SWITCH, 3-WAY DIMMER LIGHT SWITCH, DIMMERN N3 3 EXIT LIGHT FIXTURE CEILING GRID, SUSPENDED, 2'x2' NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, PENDANT LIGHT FIXTURE, 1'x4', FLUORESCENT, INDIRECT EXIT LIGHT FIXTURE LIGHT CIRCUIT LIGHT SWITCH, 3-WAY LIGHT SWITCH GYPSUM BOARD CEILING LIGHT FIXTURE, 2'x2', FLUORESCENT, PARABOLIC LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC RCP LEGEND RECESSED LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EXHAUST FAN, 2'x2' EXPOSED TO DECK 1. WHERE SHOWN, PROVIDE NEW 2'x2' 916" CEILING GRID AND 2'x2' FINE FISSURED REVEAL EDGE CEILING TILE (ARMSTRONG DUNE, OR SIMILAR). GRID TO BE INSTALLED AT 9'-0" AFF. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 5. EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE; REPLACE AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.  ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 7. PROVIDE SOUND DAMPERS IN HVAC SYSTEM SUCH THAT SOUND TRANSMISSION BETWEEN ROOMS IS REDUCED. 8. EXHAUST FAN IN RESTROOM TO BE TIED INTO SWITCH FOR LIGHT FIXTURE SUCH THAT SWITCH CONTROLS BOTH. SPECIFICATION FOR EXHAUST FAN MUST BE APPROVED BY TENANT PRIOR TO ORDERING. 9. PROVIDE SEPARATE PRICE FOR (25) ARMSTRONG TECTUM DIRECT-ATTACH ACOUSTICAL CEILING PANELS; 24X48, VERTICAL LINE DESIGN, WHITE. IF SEPARATE PRICE IS ACCEPTED, COORDINATE WITH SDI ON INSTALLATION LOCATIONS. GENERAL NOTES LIGHT FIXTURE, LED PENDANT - KUZCO LIGHTING MONAE - MEDIUM SIZE. MOUNT AT 8'-0" TO BOTTOM OF FIXTURE. LIGHT FIXTURE, 2'x4', LED, COLUMBIA LIGHTING LCAT, 3500K (OR EQUAL) LIGHT FIXTURE, FINELITE HP-2 I/D (OR EQUAL), MOUNT AT 9'-0" AFF TO BOTTOM OF FIXTURE. SEE LENGTH OF FIXTURE AS NOTED ON PLAN. LIGHT FIXTURE, 6" LED CAN LIGHT; 3500K PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND/OR JUNCTION BOX + DATA. INTENT IS FOR POKE THRU DEVICE AT THIS LOCATION TO BE COMPLETELY FLUSH WITH ADJACENT FLOOR AND CONCEAL POWER AND DATA BELOW. COORDINATE WITH TENANT + TENANT'S FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. AT EXISTING STEEL COLUMN, COORDINATE WITH TENANT ON EXACT TV SPECIFICATIONS AND PROVIDE APPROPRIATE POWER + DATA, CONDUIT, AND J-BOX AS REQUIRED FOR TELEVISION. COORDINATE MOUNTING HEIGHT WITH TENANT. PROVIDE POWER AS REQURED FOR TENANT'S WATER MACHINE AND UNDERCOUNTER REFRIGERATOR AT THIS LOCATION. 1 1 2 DocuSign Envelope ID: 7A87EDB6-ABFD-4D95-B805-21494CB57175 9/10/2020 10/02/20