HomeMy WebLinkAboutEELECTRICAL PLAN E111 PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). INTENT IS TO REUSE EXISTING SYSTEM. CONTRACTOR TO CONFIRM. SEE DOOR SCHEDULE FOR MORE DETAILS. COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 60" A.F.F. PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. COORDINATE WITH MILLWORKER AS REQUIRED FOR CASEWORK LOCATIONS. PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND DATA. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. SOME LOCATIONS MAY REQUIRE MULTIPLE DATA CONNECTIONS. PROVIDE POWER AT THIS LOCATION FOR TENANT'S DISHWASHER AND/OR GARBAGE DISPOSAL. TENANT'S FURNITURE VENDOR TO CONFIRM IF LOCATION OF EXISTING FLOOR CORE(S) IS ACCEPTABLE. REMOVE AND/OR RELOCATE AS REQUIRED. POWER AND DATA FOR COPIER TO BE FED THROUGH FURNITURE SYSTEM. COORDINATE RECEPTACLES WITH TENANT AND FURNITURE VENDOR. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. CONFIRM POWER AND DATA REQUIREMENTS FOR SERVER ROOM WITH TENANT. PROVIDE POWER AS REQUIRED FOR LIT MIRROR IN THIS LOCATION. SEE A141 FOR MORE INFORMATION. RECEPTACLE IN THIS LOCATION TO BE BLACK. COORDINATE LOCATION WITH WOOD SLATS ON WALL. PROVIDE CABLE, POWER AND DATA RECEPTACLE FOR WALL MOUNTED TELEVISION. CONFIRM EXACT HEIGHT AND LOCATION WITH TENANT. COORDINATE WITH MILLWORKER AS REQUIRED FOR CASEWORK LOCATIONS. PROVIDE DIRECT HDMI/VGA CONDUIT CONNECTION FROM FLOOR CORE POKE THRU DEVICE TO WALL MOUNTED MONITOR(S) OR CEILING MOUNTED PROJECTOR. PROVIDE POWER IN CASEWORK AS REQUIRED FOR WARMING DRAWERS. CONFIRM LOCATION AND HEIGHT WITH TENANT. ABOVE COUNTER OUTLETS TO BE INSTALLED HORIZONTALLY. CONFIRM DEVICE AND FACEPLATE COVER WITH TENANT. PLAN NOTES ELECTRICAL PLAN LEGEND DESCRIPTIONDATE ISSUE 08.31.20 75% REVIEW SET 09.02.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBER DRAWN BYPROJ. MGR STERLING INVESTORSLIFE INSURANCEMERIDIAN TOWER - SUITE 24010201 N. ILLINOIS ST, INDIANAPOLIS, IN 46290MSSDH/MS 2020.162 2ND FLOOR N 0 2'4' 8' 16' 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW AS REQUIRED. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND AUTOMATIC SHUTOFF VALVES AS REQUIRED. 5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 6. AT ROOMS WITH SOUND BARRIER DRYWALL ELECTRICIAN TO STAGGER OUTLETS AS MUCH AS POSSIBLE TO ELIMINATE SOUND TRANSFER BETWEEN ROOMS. GENERAL NOTES DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, QUADRUPLEX JUNCTION BOX POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX BOX, BLANK COVER PLATE BOX, OPEN BOX, BLANK COVER PLATE BOX, OPEN PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE CONNECTION. POWER POLE BY OTHERS. POWER AND DATA POLE FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE CEILING MOUNTED JUNCTION BOX CEILING MOUNTED JUNCTION BOX J J B O J +42" AREA NOT IN CONTRACT AREA OF WORK 10/02/20