Loading...
HomeMy WebLinkAboutA010.0WALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT METAL STUD EXISTING WINDOW MULLION EQUAL ARCHITECTURAL FLOOR PLAN A111 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. CABINETS TO BE WEBER FIRE AND SAFETY - SOLID DOOR WITH VERTICAL ENGRAVED LETTERS (#8 STAINLESS STEEL). PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W2". IF NOT, ALTER EXISTING WALL AS REQUIRED TO MATCH "W2". EXTEND DRYWALL ABOVE WINDOWS AND AT COLUMN SURROUNDS TO UNDERSIDE OF DECK AS REQUIRED. REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATION. 2'-0" H X 16'-0" LONG TEMPERED GLASS CLERESTORY WINDOW WITH 1" STAINLESS STEEL TOP AND BOTTOM RAILS TO BE INSTALLED CENTERED ON WALL IN THIS LOCATION. GLASS TO BE BUTT JOINED AT VERTICAL SEAMS WITH CLEAR POLYMER SOUND SEALS. BOTTOM OF WINDOW TO BE AT 6'-0" A.F.F. CONFIRM WINDOW SPECIFICATIONS WITH BUILDING MANAGEMENT. WALL AT THIS LOCATION TO BE CONSTRUCTED USING 2 1/2" STUDS. WALLS IN THIS AREA TO RECEIVE SOUND BARRIER DRYWALL. PLAN NOTES ARCHITECTURAL PLAN WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHTWINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL DEMISING WALL TO DECK WITH INSULATION 358" METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W1 WALL WITH INSULATION 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING SEE PLAN NOTE A08 FOR 2 1/2" STUD LOCATIONS W2 PARTIAL HEIGHT WALL 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; SEE ELEVATION FOR WALL HEIGHT; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; W3 WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DESCRIPTIONDATE ISSUE 08.31.20 75% REVIEW SET 09.02.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBER DRAWN BYPROJ. MGR STERLING INVESTORSLIFE INSURANCEMERIDIAN TOWER - SUITE 24010201 N. ILLINOIS ST, INDIANAPOLIS, IN 46290MSSDH/MS 2020.162 2ND FLOOR N 0 2'4' 8' 16' 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. IN AREA WITH EXPOSED CEILING DECK, ENSURE THAT DRYWALL ON ALL NEW AND EXISTING WALLS EXTENDS TO DECK; PROVIDE NEW DRYWALL AS REQUIRED. TRANSITION TO BE A CLEAN HORIZONTAL LINE FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. SEE REFLECTED CEILING PLAN FOR EXACT AREA OF EXPOSED CEILING. GENERAL NOTES NOT TO SCALE WALL AT MULLION DETAIL A111 1 W? AREA NOT IN CONTRACT AREA OF WORK A211 2 A211 4 A211 3 A211 6 A111 2 A211 7 TYP. A111 1 NOT TO SCALE EXEC. ENTRY DESK DETAIL A111 2 A212 7 A212 5 A211 8 A212 1 A212 1 A212 2 A212 3 A212 5 A212 6 A141 4 A141 3 0 1' 2'6" WALL DETAIL A111 3 TYP. A111 3 W3 W2 W2 W2 W2 W2 W2 W2 FURNITURE WALL SYSTEM MANUFACTURER: DHIVE FINISH: BLACK HEIGHT: 8'-0" NOTE: DESIGN INTENT IS FOR FRAME TO BE AT EXTERIOR BORDER ONLY. INTERIOR GLASS SEAMS TO BE BUTT JOINED. GLASS DOORS TO BE FRAMELESS. REFER TO DETAIL 3/A111 FOR ADDITIONAL INFORMATION ON DRYWALL TO GLASS TRANSITION. CONTACT: SCOTT MCCOY 317-417- 6776 NOTE: FURNITURE WALL SYSTEM TO BE PROVIDED BY GC. W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES AS REQUIRED. PROVIDE WATER LINE FOR COFFEE AND/OR REFRIGERATOR. CONFIRM LOCATION WITH TENANT. PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT PROVIDED DISHWASHER AT THIS LOCATION. PROVIDE COLD WATER SUPPLY AND WATER LINES AS REQUIRED FOR NEW TOILETS AND URINAL. PROVIDE ALL REQUIRED PLUMBING AND DRAINS FOR TENANT PROVIDED ICE MAKER. WHERE DRYWALL WALL CONSTRUCTION ENDS, PROVIDE VERTICAL DHIVE FURNITURE SYSTEM MULLION. FRAMING TO BE INSTALLED CENTERED ON THICKNESS OF DRYWALL WALL CONSTRUCTION. PROVIDE SHOP DRAWINGS OF DHIVE WALL SYSTEM TO TENANT FOR APPROVAL. A212 8 FURNITURE WALL SYSTEM - SEE WALL TYPE W4 FOR ADDITIONAL INFORMATION W2 W2 W2 W2 W2 10/02/20