HomeMy WebLinkAboutA010.0WALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
METAL STUD
EXISTING WINDOW
MULLION
EQUAL
ARCHITECTURAL
FLOOR PLAN
A111
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x8'x3
4", PAINTED WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING TO NFPA 10. CABINETS TO BE WEBER FIRE AND
SAFETY - SOLID DOOR WITH VERTICAL ENGRAVED LETTERS (#8
STAINLESS STEEL).
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W2". IF NOT,
ALTER EXISTING WALL AS REQUIRED TO MATCH "W2".
EXTEND DRYWALL ABOVE WINDOWS AND AT COLUMN
SURROUNDS TO UNDERSIDE OF DECK AS REQUIRED. REFER TO
REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATION.
2'-0" H X 16'-0" LONG TEMPERED GLASS CLERESTORY WINDOW
WITH 1" STAINLESS STEEL TOP AND BOTTOM RAILS TO BE INSTALLED
CENTERED ON WALL IN THIS LOCATION. GLASS TO BE BUTT JOINED
AT VERTICAL SEAMS WITH CLEAR POLYMER SOUND SEALS.
BOTTOM OF WINDOW TO BE AT 6'-0" A.F.F. CONFIRM WINDOW
SPECIFICATIONS WITH BUILDING MANAGEMENT.
WALL AT THIS LOCATION TO BE CONSTRUCTED USING 2 1/2"
STUDS.
WALLS IN THIS AREA TO RECEIVE SOUND BARRIER DRYWALL.
PLAN NOTES
ARCHITECTURAL PLAN
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHTWINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
DEMISING WALL TO DECK
WITH INSULATION
358" METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W1 WALL WITH INSULATION
358 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
SEE PLAN NOTE A08 FOR 2 1/2" STUD LOCATIONS
W2
PARTIAL HEIGHT WALL
358 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE;
SEE ELEVATION FOR WALL HEIGHT;
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED;
W3
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
DESCRIPTIONDATE
ISSUE
08.31.20 75% REVIEW SET
09.02.20 PERMIT SET
REVISIONS
DESCRIPTIONMARK DATE DB
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBER
DRAWN BYPROJ. MGR STERLING INVESTORSLIFE INSURANCEMERIDIAN TOWER - SUITE 24010201 N. ILLINOIS ST, INDIANAPOLIS, IN 46290MSSDH/MS
2020.162
2ND FLOOR
N
0 2'4' 8' 16'
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
3. IN AREA WITH EXPOSED CEILING DECK, ENSURE THAT DRYWALL
ON ALL NEW AND EXISTING WALLS EXTENDS TO DECK; PROVIDE
NEW DRYWALL AS REQUIRED. TRANSITION TO BE A CLEAN
HORIZONTAL LINE FINISHED SUCH THAT CONTRASTING PAINT
COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING
LINE. SEE REFLECTED CEILING PLAN FOR EXACT AREA OF EXPOSED
CEILING.
GENERAL NOTES
NOT TO SCALE
WALL AT MULLION DETAIL
A111
1
W?
AREA NOT IN CONTRACT
AREA OF WORK
A211
2
A211
4
A211
3
A211
6
A111
2
A211
7
TYP.
A111
1
NOT TO SCALE
EXEC. ENTRY DESK DETAIL
A111
2
A212
7
A212
5
A211
8
A212
1
A212
1
A212
2
A212
3
A212
5
A212
6
A141
4
A141
3
0 1' 2'6"
WALL DETAIL
A111
3
TYP.
A111
3
W3
W2 W2
W2
W2
W2
W2
W2
FURNITURE WALL SYSTEM
MANUFACTURER: DHIVE
FINISH: BLACK
HEIGHT: 8'-0"
NOTE: DESIGN INTENT IS FOR FRAME TO BE AT
EXTERIOR BORDER ONLY. INTERIOR
GLASS SEAMS TO BE BUTT JOINED. GLASS
DOORS TO BE FRAMELESS. REFER TO
DETAIL 3/A111 FOR ADDITIONAL
INFORMATION ON DRYWALL TO GLASS
TRANSITION.
CONTACT: SCOTT MCCOY 317-417- 6776
NOTE: FURNITURE WALL SYSTEM TO BE
PROVIDED BY GC.
W4
W4
W4
W4
W4 W4 W4
W4
W4
W4 W4
W4
W4
_______________________________________________________________
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
PROVIDE WATER LINE FOR COFFEE AND/OR REFRIGERATOR.
CONFIRM LOCATION WITH TENANT.
PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT
PROVIDED DISHWASHER AT THIS LOCATION.
PROVIDE COLD WATER SUPPLY AND WATER LINES AS REQUIRED
FOR NEW TOILETS AND URINAL.
PROVIDE ALL REQUIRED PLUMBING AND DRAINS FOR TENANT
PROVIDED ICE MAKER.
WHERE DRYWALL WALL CONSTRUCTION
ENDS, PROVIDE VERTICAL DHIVE FURNITURE
SYSTEM MULLION. FRAMING TO BE
INSTALLED CENTERED ON THICKNESS OF
DRYWALL WALL CONSTRUCTION. PROVIDE
SHOP DRAWINGS OF DHIVE WALL SYSTEM
TO TENANT FOR APPROVAL.
A212
8
FURNITURE WALL SYSTEM -
SEE WALL TYPE W4 FOR
ADDITIONAL
INFORMATION
W2 W2
W2
W2
W2