HomeMy WebLinkAboutA010.1REFLECTED CEILING PLAN A121 CONTROL COPY 208, OPEN OFFICE 209, AND COPY 214 LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. CONTROL EXEC ENTRY 219 AND COPY/COFFEE 220 LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. ACOUSTICAL CEILING (TILES AND GRID) IN ENTRY 201 TO BE PAINTED PT3. REFER TO FINISH LEGEND FOR ADDITIONAL INFORMATION. IN AREA TO BE EXPOSED TO DECK, REPLACE LOW PRESSURE SUPPLY BRANCH LINE DUCT AND WITH NEW RIGID SPIRAL DUCT AND RECTANGULAR SUPPLY DIFFUSERS AS REQUIRED. CLEAN AND PREPARE FOR DRYFALL PAINT (PT4). AS SPECIFIED, PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS FIREPROOFING, ETC. IN ACCORDANCE WITH NFPA 13 6.3.8. CEILING CLOUD TO BE INSTALLED AT 10'-0". AT PERIMETER, PROVIDE 4" AXIOM TRIM (WHITE). CLOUD TO BE INSTALLED AT 9'-0". CONFIRM HEIGHT WITH TENANT. DRYWALL BULKHEAD TO ALIGN WITH CORNER IN THIS LOCATION. BOTTOM OF BULKHEAD TO BE AT 8'-0". TRANSITION FROM CEILING GRID TO EXPOSED CEILING TO BE A DRYWALL BULKHEAD EXTENDING FROM 1" BELOW ACOUSTICAL CEILING TO DECK. TRANSITION TO BE A CLEAN VERTICAL BULKHEAD, FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. VERTICAL FACE OF DRYWALL TO BE PAINTED COLOR OF ADJACENT WALL. CONFIRM INSTALLATION LOCATION AND MOUNTING HEIGHTS WITH TENANT IN FIELD. PROVIDE UNDER CABINET LIGHT FIXTURES AT FULL LENGTH OF UPPER CABINETS, CONTROLLED WITH SEPARATE SWITCH. SEE ELEVATION FOR MORE INFORMATION. LIT MIRROR TO BE ON SAME CIRCUIT AS CAN LIGHTS. CONFIRM WITH TENANT. PROVIDE DRYWALL BULKHEAD AT THIS LOCATION AS REQUIRED FOR DHIVE WALL SYSTEM. COORDINATE WITH MANUFACTURER AS REQUIRED. ABOVE COUNTER SWITCH TO BE INSTALLED HORIZONTALLY. PLAN NOTES LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH ND N N3 D 3 EXIT LIGHT FIXTURE - LED EDGE LIT LIGHT FIXTURE, PENDANT (PROVIDED BY TENANT) RECESSED LIGHT FIXTURE, LED LIGHT FIXTURE, 2'x2', BUILDING STANDARD LED LIGHT FIXTURE, 2'x4', BUILDING STANDARD LED RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' - ARMSTRONG - LYRA - GRID TO BE 9/16 IN SILVER, TILES TO MATCH PT3 NEW OR RELOCATED EXISTING TO REMAIN WALL SCONCE LIGHT FIXTURE (PROVIDED BY TENANT) EXIT LIGHT FIXTURE LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x2' DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 4'x4' - ARMSTRONG LYRA CONCEALED CEILING GRID, SUSPENDED, 4'x4' GYPSUM BOARD CEILING LEGEND REFLECTED CEILING PLAN RECESSED LIGHT FIXTURE, LED WALL SCONCE LIGHT FIXTURE DESCRIPTIONDATE ISSUE 08.31.20 75% REVIEW SET 09.02.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBER DRAWN BYPROJ. MGR STERLING INVESTORSLIFE INSURANCEMERIDIAN TOWER - SUITE 24010201 N. ILLINOIS ST, INDIANAPOLIS, IN 46290MSSDH/MS 2020.162 2ND FLOOR N 0 2'4' 8' 16' EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP EXHAUST FAN, 2'x2' EXHAUST FAN, 2'x2' SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) NG G SWITCH, GARBAGE DISPOSAL EXPOSED TO DECK A121 1 SWITCH, EXHAUST FAN NE E SWITCH, EXHAUST FAN 1. PROVIDE NEW CEILING GRID AND TILE THROUGHOUT. GRID TO BE 10'-0" A.F.F. REFER TO PLAN AND LEGEND FOR MORE INFORMATION. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 5. ALL NEW AND EXISTING FACE PLATES TO BE WHITE. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.¬ ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 4. CONFIRM INSTALLATION LOCATIONS OF ALL LIGHTING FIXTURES ON SITE WITH TENANT. 5. TENANT TO CONFIRM ALL DIMMING REQUIREMENTS. 6. PROVIDE SUBMITTALS/SHOP DRAWINGS FOR ALL CEILINGS AND LIGHTING FIXTURES TO TENANT FOR APPROVAL. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.¬NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED.¬ ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED;¬ MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES AREA NOT IN CONTRACT AREA OF WORK LIGHT FIXTURE, 2'x2', BUILDING STANDARD LED LIGHT FIXTURE, 2'x4', BUILDING STANDARD LED LIGHT FIXTURE, PENDANT (PROVIDED BY TENANT) LIGHT FIXTURE, PENDANT LIGHT FIXTURE, PENDANT (PROVIDED BY TENANT) LIGHT FIXTURE, PENDANT (PROVIDED BY TENANT) LIGHT FIXTURE, PENDANT - AXIS - STENCIL - 4'-0" - BLACK (OR EQUAL) A LIGHT FIXTURE, PENDANT - AXIS - BEAM 2 - 8'-0" - WHITE (OR EQUAL) B LIGHT FIXTURE, PENDANT - AXIS - STENCIL - 8'-0" - BLACK (OR EQUAL) C LIGHT FIXTURE, PENDANT - AXIS - STENCIL - 6'-0" - BLACK (OR EQUAL) D LIGHT FIXTURE, PENDANT - AXIS - STENCIL - LENGTHS VARY - BLACK (OR EQUAL) E SUSPENDED CLOUD - ARMSTRONG SOUNDSCAPES - HEXAGON - 48" - WHITE LIGHT FIXTURE, RECESSED - AXIS - BEAM 2 - 6'-0" (OR EQUAL) F LIGHT FIXTURE, RECESSED - AXIS - BEAM 2 - 8'-0" (OR EQUAL) G LIGHT FIXTURE, RECESSED - AXIS - BEAM 2 - 16'-0" (OR EQUAL) H A B C D LIGHT FIXTURE, PENDANT - AXIS - BEAM 4 - 8'-0" BLACK (OR EQUAL) J LIGHT FIXTURE, RECESSED - AXIS - BEAM 2 - 4'-0" (OR EQUAL) K LIGHT FIXTURE, RECESSED - AXIS - PERFEKT WALL WASHER - 8'-0" (OR EQUAL) L LIGHT FIXTURE, RECESSED - AXIS - PERFEKT WALL WASHER - 4'-0" (OR EQUAL) M A WALL SCONCE LIGHT FIXTURE (PROVIDED BY TENANT) B CEILING FAN, CRAFTMADE - MONDO - 72" - CONFIRM FINISH WITH TENANT CONTACT GINA WILLIAMS AT ESL SPECTRUM FOR MORE INFORMATION AND PRICING ON AXIS FIXTURES - 317-223-2614 10/02/20