Loading...
HomeMy WebLinkAboutAS1-1 - Wendys Exterior Cooler - Filing Sheet -- Rev 2EXISTING DUMPSTER ENCLOSURE EXTENDED EXISTING WALL HEIGHT NEW EXTERIOR FREEZER UNIT NEW FREEZER ENCLOSURE WALL NEW 8'X14' STAND ALONE FREEZER ON NEW 9'X15' CONCRETE SLAB - SEE DETAIL THIS PAGE REMOVE LANDSCAPING - EXTEND DUMPSTER ENCLOSURE - TO WRAP AROUND NEW COOLER EXISTING PARKING AREA PROPERTY LINE EXISTING PARKING AREA N. MICHIGAN ROADWALNUT CREEK DRIVEEXISTING BUILDING NEW POWER SUPPLY -VERIFY ROUTE IN FIELD 208V 1Ø 25 AMP POWER SUPPLY FROM EXISTING BUILDING PANEL FILE01/12/20STORAGE 11-B SHEET:TITLE: 211 S. RITTER AVE. - SUITE H INDIANAPOLIS, IN 46129 PH: 317-828-1166 FAX: 317-493-1805 e-mail: JTDESIGNERSINC@GMAIL Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or descibed, the trade contractors shall furnish all items required for the proper execution and completion of the work. 112 sf REV1 CITY COMMENT 09/14/20 S2 WENDY'S BREADCARMEL, IN 46032MARION COUNTY10585 MICHIGAN ROAD ROADATTN: David Mazza REVIEWEXTERIOR COOLER(317) 417 – 4985 Aquila Construction Services 172 W King St Franklin, IN 46131 david@ aquila-construction .com WENDY'S EXTERIOR BREAD FREEZER AS1.1 FREEZER UNIT ELEVATIONS 14' 8' 2'8'8' 2'8' 2' 8' 2' 14' 8' STAND ALONE UL LISTED FREEZER W/ WHITE GALVANIZED EXTERIOR CONDENSING UNIT SIDE SIDE BACK FRONT PLAN VIEW : 0'-6' AFF SCALE: 1/4" = 1'-0" PLAN VIEW : 6'-10' AFF SCALE: 1/4" = 1'-0" 9'15'-4" 3'-4" 1'-4" F.V.10'15'-4" PROPOSED NEW FREEZER UNIT EXISTING MASONRY WALL 8" CMU MASONRY WALL BRICK MASONRY VENEER- MATCH EXISTING 4" CMU MASONRY SCREEN WALL BRICK MASONRY VENEER- MATCH EXISTING 4" CMU MASONRY SCREEN WALL PROPOSED NEW FREEZER UNIT ARCHITECTURAL SITE PLAN SCALE: 1" = 20'-0" SECTION 1 SCALE: 3/4" = 1'-0" SECTION 2 SCALE: 3/4" = 1'-0" SECTION 3 SCALE: 3/4" = 1'-0" NEW 12"X36" CONCRETE GRADE BEAM #5 REBAR TOP AND BOTTOM NEW CONCRETE SLAB MASONRY VENEER WITH WIRE TIES EVERY THIRD COURSE 4" CMU NEW WALK-IN FREEZER UNIT CONCRETE CAP TO MATCH EXISTING #5 REBAR IN GROUTED CELLS AT 48" O.C. - MAX EXISTING FOUNDATION NEW 8" CMU AT EXISTING MAN OPENING IN WALL NEW 4" CMU NEW WALK-IN FREEZER UNIT CONCRETE CAP TO MATCH EXISTING REMOVE EXISTING WALL CAP NEW CONCRETE SLAB MASONRY VENEER WITH WIRE TIES EVERY THIRD COURSE NEW #5 REBAR IN GROUTED CELLS- 48" O.C. MAX. GROUT CORES SOLID REINFORCING TIE-IN LOCATIONS EXISTING FOUNDATION EXISTING 4" CMU AND MASONRY VENEER WALL TO REMAIN NEW 4" CMU NEW WALK-IN FREEZER UNIT CONCRETE CAP TO MATCH EXISTING REMOVE EXISTING WALL CAP NEW CONCRETE SLAB MASONRY VENEER WITH WIRE TIES EVERY THIRD COURSE NEW #5 REBAR IN GROUTED CELLS- 48" O.C. MAX. GROUT CORES SOLID REINFORCING TIE-IN LOCATIONS FOUNDATION PLAN SCALE: 1/4" = 1'-0" NEW 12" X 36" CONC GRADE BEAM 1 #5 REBAR T&B #4 TIES AT 24" O.C. EXISTING FOUNDATION WALL AND SPREAD FOOTING9'-6"15'-8"1'-4"8'-2" 2" OFFSET2 1 3 3 5" 7'-8"14'-10"8' 2'10'-4" SCREEN WALL HIGHER THAN COOLER AND EQUIPMENT10'-4"10'-4"OPTIONAL GATE UNIT OPTIONAL GATE UNIT NEW CONCRETE AREA W/ BICYCLE RACKS NEW CONCRETE AREA 15' 15'-11 1 2 " NEW POWER SUPPLY -VERIFY ROUTE IN FIELD 208V 1Ø 25 AMP POWER SUPPLY FROM EXISTING BUILDING PANEL 10/02/20