Loading...
HomeMy WebLinkAboutSM01 Ductwork RunSD5 210 CFM SD5 210 CFM SD5 210 CFM SD5 210 CFM SD5 210 CFM SD5 210 CFM SD2 225 CFM SD2 200 CFM SD3 240 CFM SD3 240 CFM SD5 155 CFM SD2 200 CFM SD2 200 CFM SD3 300 CFM SD2 225 CFM SD2 225 CFM SD4 100 CFM SD5 155 CFM SD2 140 CFM SD5 155 CFM SD5 155 CFM SD5 155 CFM SD5 155 CFM SD5 218 CFM SD5 218 CFM SD5 218 CFM SD5 155 CFM SD5 155 CFM SD5 218 CFM SD3 240 CFM SD3 240 CFM SD2 155 CFM ED1 75 CFM RG1 RG1 RG1RG1 RG1RG1 RG1 RG5 RG3 RG1 P.F. P.F. P.F. ED2 150 CFM RG4 ED1 75 CFM ED1 75 CFM ED1 75 CFM SD5 155 CFM SD5 155 CFM RA RB RC RD RE RF RG RH R1 R1.8 R2 R3 R4 R5 R6 R7 R8 TOD= 12' - 4"BOD= 11' - 6"TOD= 12' - 6" BOD= 11' - 6"TOD= 12' - 5"BOD= 11' - 9"TOD= 12' - 8" BOD= 11' - 10" TOD= 12' - 8" BOD= 11' - 10" 18"x10" 14"x8"14"x8"10"ø 8"ø6"ø8"øBALANCE TO 628 CFM BALANCE TO 322 CFM 14X14 ID TRANSFER 13'-0" T.O.D. 14X12 TRANSFER 13'-0" T.O.D. BALANCE TO 321 CFM BALANCE TO154 CFM12"ø10"ø 8"ø6"ø 8"ø 8"ø 14"x10"12"ø 10"ø 8"ø8"ø14"ø 12"ø 14"x10"18"x14" 8"ø8"ø10"ø 10"ø8"ø 8"ø 12"ø10"ø 12"ø 8"ø 10"ø 8"ø 8"ø 12"ø 8"ø 14"ø 16"ø8"ø 10"ø 12"ø 12"ø12"x12" 8"ø 10"ø8"ø8"ø12"ø 8"ø8"ø14"ø 8"ø8"ø16"ø 18"x14"8"ø14"x10" 10"ø 12"ø 8"ø 8"ø 10"ø6"ø8"ø 8"ø FILTER FILTERFILTERFILTER FILTER FILTERFILTER 10"ø BALANCE TO321 CFMBALANCE TO 154 8"ø 12"ø 12"ø10"ø 8"ø FCU-2W-1FCU-2E-4FCU-2E-2 FCU-2W-2 FCU-2W-3FCU-2E-3FCU-2E-1 8"øRG5 REMOVE EXISTING DAMPER BALANCE AT 830 CFM BALANCE AT 830 CFMTOD= 13' - 2"BOD= 11' - 10"TOD= 13' - 1"BOD= 11' - 11"TOD= 12' - 4"BOD= 11' - 4"TOD= 12' - 3"BOD= 11' - 5"TOD= 12' - 2" BOD= 11' - 6"TOD= 11' - 8"BOD= 11' - 0"TOD= 11' - 9" BOD= 10' - 11" TOD= 11' - 10" BOD= 10' - 10" TOD= 11' - 4"BOD= 10' - 4"TOD= 11' - 10"BOD= 10' - 8"TOD= 11' - 4"BOD= 10' - 2"TOD= 11' - 8"BOD= 10' - 10"TOD= 11' - 7" BOD= 10' - 11" TOD= 11' - 7" BOD= 10' - 11" TOD= 11' - 9" BOD= 10' - 9" TOD= 13' - 2" BOD= 12' - 4"TOD= 12' - 8" BOD= 11' - 10" TOD= 12' - 9" BOD= 11' - 9"TOD= 12' - 7"BOD= 11' - 11"TOD= 11' - 11" BOD= 11' - 1" TOD= 12' - 0" BOD= 11' - 0" TOD= 11' - 10" BOD= 11' - 2" TOD= 11' - 9" BOD= 11' - 3"TOD= 11' - 10"BOD= 11' - 2"TOD= 12' - 11" BOD= 12' - 1" TOD= 13' - 0" BOD= 12' - 0" TOD= 12' - 11" BOD= 12' - 1"TOD= 13' - 0"BOD= 12' - 4"TOD= 12' - 11"BOD= 12' - 5"TOD= 13' - 0" BOD= 12' - 4"TOD= 14' - 3"BOD= 13' - 3"TOD= 13' - 7"BOD= 12' - 7"TOD= 12' - 5"BOD= 11' - 5"TOD= 12' - 6" BOD= 11' - 6"TOD= 12' - 5"BOD= 11' - 7"TOD= 12' - 10"BOD= 12' - 2"TOD= 12' - 5" BOD= 11' - 9" TOD= 12' - 3" BOD= 10' - 11" TOD= 12' - 2" BOD= 11' - 0" TOD= 12' - 1" BOD= 11' - 1" TOD= 11' - 10" BOD= 11' - 0"TOD= 11' - 11"BOD= 10' - 11"TOD= 13' - 2"BOD= 12' - 2"TOD= 12' - 0" BOD= 11' - 0"TOD= 13' - 0"BOD= 12' - 0"TOD= 12' - 4"BOD= 11' - 8"TOD= 12' - 6"BOD= 11' - 6"TOD= 13' - 2"BOD= 12' - 4"TOD= 13' - 3"BOD= 12' - 3"12X10 TRANSFER 13'-0" T.O.D. CONNECT TO EXISTING 12"ø 22.5° 22.5° 22.5° 22.5° 45° 45° 22.5° 22.5° 22.5° 45° 45° 45° 45° 22.5° 22.5° 22.5° 22.5° 22.5° 22.5°16"120" 86"19"13"92" 120" 24" CAP 120" 29" 10"35" 76" 49"5" 7" 104" 120" 85" 33"120" 120" 38"55"14" 6" 18" 26" 16" 12" 120" 120" 120" 51" 55"CAP 46" 120" 120" 42" 120" 120" 88" 120"13"13"14"14"15"15"CAPVD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD VD 63"20"60"77" 108" 23" 6" 24"120" 46"120" 120" 120" 35" 96"219" 27"219"118" 33"36" 40"47" 120" 36"27"85" 33" 12" 120" 49" 120" 21" 24" 120" 71"120" 72" 72" 65" 40" 47" 41" 69"72"31" 66" 120" 36" 23" 74"22" 18" 15"20" 18" 1 FOR 12" ℄℄℄℄ ℄℄℄℄12" TOD= 12' - 4" BOD= 11' - 8" ROLL OFFSET DOWN TO UNDER BEAM 14"20"FOR12" FOT 2 12" ℄℄℄℄14" 31" 3 4 DIFFUSER MOUNTED AT 10' - 0" AFF TYPICAL 17" 16" 8" 9" 12" 1X 12" 90° ELBOW TAPPED OUT TOP OF EXISTING DUCT SYMBOL MAUNUFACTURER/MODEL MATERIAL & TYPE MAX CFM NOM SIZE NECK SIZE NC REMARKS GRILLES, REGISTERS, AND DIFFUSERSSD1 115 24X24 6" 15 3,5METALAIRE STEEL 5750 SQUARE PLAQUE FACE SD2 225 8" 16 3,5METALAIRE STEEL 5750 SQUARE PLAQUE FACE SD3 375 10" 20 3,5METALAIRE STEEL 5750 SQUARE PLAQUE FACE SD4 100 16-1/8 6" 15 6METALAIRE STEEL 3100S-2 ROUND FIXED DROP CONE SD5 185 16-1/8 8" 17 6METALAIRE STEEL 3100S-2 ROUND FIXED DROP CONE RG1 N/A 24X12 22X10 N/A 2,3METALAIRE ALUMINUM CC5 EGGCRATE RETURN RG2 N/A 18X14 N/A 4METALAIRE RG3 N/A 26X20 24X18 N/A 4METALAIRE RG4 N/A N/A 4METALAIRE STEEL SRH RETURN GRILLE METALAIRE STEEL 24X24 24X24 20X16 38X16 36X14 1. 3-Way Perimeter Diffuser w/blank- off. 2. Provide Insulated Sound Boot. 3. Lay-in Mount. 4. Surface Mount. 5. Provide Plaster Frame where required.RG5 N/A N/A 4SRH RETURN GRILLE 10X8 8X6 STEEL SRH RETURN GRILLE STEEL SRH RETURN GRILLE ED2 150 24X24 8" 15 3,5METALAIRE STEEL 5750 SQUARE PLAQUE FACE ED1 115 24X24 6" 15 3,5METALAIRE STEEL 5750 SQUARE PLAQUE FACE 6. Duct Mount. PLAN NOTES: 1. BOTTOM DOWN 9 1/2" 2. BOTTOM DOWN 4 1/2" 3. BOTTOM DOWN 3 1/2" 4. BOTTOM DOWN 9" DUCT PRESSURE CLASSIFICATION TERMINAL BOXES TO DIFFUSERS ALL SUPPLY DUCTS FROM VAV ALL RETURN AIR DUCTS ALL GENERAL EXHAUST DUCTS -2"wg +2"wg -2"wg ALL CONSTANT VOLUME SUPPLY +2"wg ALL TRANSFER AIR DUCTS 1/2"wg ALL OUTSIDE AIR DUCTS +2"wg FLEXIBLE DUCT AND NECK SIZE DIFFUSER/GRILLE TYPE - CFM TOP & BOTTOM DUCT ELEVATION TRANSITION FLAT ON TOP SYMBOL LEGEND 90° ELBOW W/TURNING VANES ACCESS DOOR IN DUCT FIRE DAMPER VOLUME DAMPER GRILLE DIFFUSER FOT TOD = BOD = SD - 300 12 ∅ TRANSITION FLAT ON LEFTFOB FD A.D. MOTORIZED DAMPERM VD DUCT SIZE AND LENGTHW x H L(x) DUCT SIZE AND LENGTHW x H L(x) LINED DUCT SIZE AND LENGTHW x H L(x) DIMENSIONS ARE O.D. DUCT SIZE FLEXIBLE CONNECTION GENERAL NOTES 1. ALL DUCTWORK TO BE FABRICATED AND INSTALLED PER S.M.A.C.N.A. STANDARDS, PROJECT SPECIFICATIONS, ADDENDUMS, AND SHOP STANDARDS SUBMITTAL PER THIS PROJECT. 2. ALL DUCT ELEVATIONS ARE FROM FINISHED FLOOR 0'-0" UNLESS NOTED ON DRAWINGS. 3. ALL DUCT DIMENSIONS ARE NOTED AS OUTSIDE DIMENSIONS. 4. ALL SQUARE 90° ELBOWS AND TEES TO HAVE TURNING VANES. 5. ALL SQUARE 90° ELBOWS AND TEES ARE 6" THROATS UNLESS NOTED ON DRAWINGS. 6. ALL RADIUS 90° ELBOWS ARE 1 1/2 (x) AT CENTERLINE UNLESS NOTED ON DRAWINGS. 7. VERIFY LOCATION AND ELEVATION OF DUCT, ARRANGEMENT OF GRD's, EQUIPMENT AND ACCESS DOORS AFTER COORDINATION WITH OTHER TRADES. 2514 East Bethel Avenue, Indianapolis, IN 46203 Phone (317)780-1864 Fax (317)780-7968 MECHANICAL CONTRACTOR: CONSTRUCTION NOT INDICATED HEREIN WILL IN NO WAY BE PERMITTED OR CONVEY ADDED SPECIFIED AND THAT ANY USE OF THESE DESIGNS, EITHER IN WHOLE OR IN PART, FOR OTHER IT IS THE INTENT OF THIS CONTRACTOR THAT THESE DRAWINGS BE USED ONLY FOR THE PROJECT INTENT OR RESPONSIBILITY BY METAL MASTERS INC. DRAWN BY: DRAWING OF: DUCTWORK PLAN SCALE: ARCH E1 (30.00 X 42.00 INCHES)PROJECT NUMBER: 8. RETURN AIR CANOPY - LINER IS FIBER-FREE FLAME/SMOKE < 25/50 9. ALL DUCTWORK MATERIAL IS G90 GALVANIZED A653 10.ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED PER SMACNA HVAC DUCT CONSTRUCTION STANDARDS THIRD EDITION 11.FLEXIBLE DUCTOWRK = HART & COOLEY F114, UL 181 AND NFPA 90-A & 90B COMPLIANCE, R-4.2, FLAME/SMOKE < 25/50, 12: W.C. POS. AND .75" W.C. NEG. ALL FLEXIBLE DUCTWORK IS 10" DIA. OR LESS. MAX FLEX LENGTH IS 5'-0". NYLON CABLE TIES FOR CONNECTIONS TO DUCTWORK AND DIFFUSER. USE SMART FLOW ELBOW FOR CONNECTION TO EACH DIFFUSER. 00000 LEACH & RUSSELLSIMPLIFEYESIMPLIFEYESIMPLIFEYESIMPLIFEYESUITE 200 BUILD OUTSUITE 200 BUILD OUTSUITE 200 BUILD OUTSUITE 200 BUILD OUT211 W. MAIN ST.CARMEL, IN 46032SM-01 JBG Building/Area 1/4" = 1'-0" NNNN REVISION SCHEDULE NO. DESCRIPTION DATE 1 PERMIT SET 08/17/20 10/07/20