HomeMy WebLinkAboutEvans May Mechanical ComCheckCOMcheck Software Version 4.1.4.0 Mechanical Compliance Certificate Project Title: 90.1 (2007) Standard Project Type:Alteration Location:Carmel, Indiana Climate Zone:5a Construction Site: 211 W. Main ST Carmel, IN 46032 Owner/Agent: Erice Hannum Monon Developments Company 3050 Poplar Street Terre Haute, IN 47803 (317) 518-5768 ehannum@garmong.net Designer/Contractor: William Maltby Genesis Engineering 91 S. Main Street, Suite 200 Zionsville, IN 46077 (317) 847-7480 wmaltby@genesis-engineering.com Project Information Energy Code: Evans May Wealth Mechanical Systems List Quantity System Type & Description VRF Condensing Unit, Air Cooled w/ Heat Recovery Heat Pump Heating Mode: Capacity = 162 kBtu/h, Cooling Mode: Capacity = 144 kBtu/h, , Unknown Economizer Fan System: None SYSTEM COMPLIANCE EXEMPTION APPLIES Exemption: Refrigerant change. 1 HRU-3 EAST VRF Condensing Unit, Air Cooled w/ Heat Recovery Heat Pump Heating Mode: Capacity = 81 kBtu/h, No minimum efficiency requirement applies Cooling Mode: Capacity = 72 kBtu/h, No minimum efficiency requirement applies Fan System: None SYSTEM VERIFICATION REQUIRED. 1 HRU-3 WEST Cooling: 1 each - VRF Zone Fan Unit, Capacity = 54 kBtu/h, No Economizer, Economizer exception: High Efficiency Equipment No minimum efficiency requirement applies Fan System: Unspecified SYSTEM VERIFICATION REQUIRED. 1 FCU-3W-1 Cooling: 1 each - VRF Zone Fan Unit, Capacity = 48 kBtu/h No minimum efficiency requirement applies Fan System: Unspecified SYSTEM VERIFICATION REQUIRED. 2 FCU-3E-4,5 Cooling: 1 each - VRF Zone Fan Unit, Capacity = 36 kBtu/h No minimum efficiency requirement applies Fan System: Unspecified SYSTEM VERIFICATION REQUIRED. 1 FCU-3E-6 Project Title: Data filename: Evans May Wealth P:\_2020 Projects\Leach and Russell - Monon on Main Second and Third Floor Buldout\COMCheck\Mechanical COMCheck 3rd Floor.cck 09/08/20Report date: 101 ofPage Quantity System Type & Description Cooling: 1 each - VRF Zone Fan Unit, Capacity = 24 kBtu/h Fan System: Unspecified SYSTEM COMPLIANCE EXEMPTION APPLIES Exemption: Relocation of existing equipment. 3 FCU-3E-1,2 AND FCU-3W-2 Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.1.4.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Data filename: Evans May Wealth P:\_2020 Projects\Leach and Russell - Monon on Main Second and Third Floor Buldout\COMCheck\Mechanical COMCheck 3rd Floor.cck 09/08/20Report date: 102 ofPage William Maltby PE 09/08/2020 Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.4.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2007) Standard Section # & Req.ID Plan Review Complies?Comments/Assumptions 4.2.2, 6.4.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Complies Does Not Not Observable Not Applicable Requirement will be met. 4.2.2, 7.4.1 [PR3]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: NOT APPLICABLE 6.7.2.4 [PR5]1 Detailed instructions for HVAC systems commissioning included on the plans or specifications for projects >=50,000 ft2. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Evans May Wealth P:\_2020 Projects\Leach and Russell - Monon on Main Second and Third Floor Buldout\COMCheck\Mechanical COMCheck 3rd Floor.cck 09/08/20Report date: 103 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions 6.4.3.8 [FO9]3 Freeze protection and snow/ice melting system sensors for future connection to controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Evans May Wealth P:\_2020 Projects\Leach and Russell - Monon on Main Second and Third Floor Buldout\COMCheck\Mechanical COMCheck 3rd Floor.cck 09/08/20Report date: 104 ofPage Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 6.4.1.4, 6.4.1.5 [ME1]2 HVAC equipment efficiency verified. Non-NAECA HVAC equipment labeled as meeting 90.1. Efficiency:_____Efficiency:_____Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. 6.4.3.4.1 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.4.3.4.2, 6.4.3.4.3, 6.4.3.4.4 [ME4]3 Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: EXISTING ERV 6.4.3.4.5 [ME5]3 Ventilation fans >0.75 hp have automatic controls to shut off fan when not required. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: NOT APPLICABLE 6.4.3.9 [ME6]1 Demand control ventilation provided for spaces >500 ft2 and >40 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: EXISTING ERV 6.4.4.1.1 [ME7]3 Insulation exposed to weather protected from damage. Insulation outside of the conditioned space and associated with cooling systems is vapor retardant. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.1.2 [ME8]2 HVAC ducts and plenums insulated. R-_____R-_____Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.1.3 [ME9]2 HVAC piping insulation thickness._____ in._____ in.Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.2.1 [ME10]2 Ducts and plenums sealed based on static pressure and location. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Evans May Wealth P:\_2020 Projects\Leach and Russell - Monon on Main Second and Third Floor Buldout\COMCheck\Mechanical COMCheck 3rd Floor.cck 09/08/20Report date: 105 ofPage Section # & Req.ID Mechanical Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.4.4.2.2 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.1, 6.5.1.1.1, 6.5.1.1.2, 6.5.1.1.3, 6.5.1.3 [ME12]1 Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high- limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. Complies Does Not Not Observable Not Applicable 6.5.2.3 [ME19]3 Dehumidification controls provided to prevent reheating, recooling, mixing of hot and cold airstreams or concurrent heating and cooling of the same airstream. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: NOT APPLICABLE 6.5.4.1 [ME25]3 HVAC pumping systems >10 hp designed for variable fluid flow. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: NOT APPLICABLE 6.5.6.1 [ME30]1 Exhaust air energy recovery on systems >=5,000 cfm and 70% of design supply air. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: EXISTING ERV 6.5.7.1 [ME32]2 Kitchen hoods >5,000 cfm have make up air >=50% of exhaust air volume. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.7.2 [ME33]1 Fume hoods exhaust systems >=15,000 cfm have VAV hood exhaust and supply systems, direct make-up air or heat recovery. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 6.5.8.1 [ME34]3 Unenclosed spaces that are heated use only radiant heat. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Evans May Wealth P:\_2020 Projects\Leach and Russell - Monon on Main Second and Third Floor Buldout\COMCheck\Mechanical COMCheck 3rd Floor.cck 09/08/20Report date: 106 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions 10.4.1 [EL9]2 Electric motors meet requirements where applicable. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Evans May Wealth P:\_2020 Projects\Leach and Russell - Monon on Main Second and Third Floor Buldout\COMCheck\Mechanical COMCheck 3rd Floor.cck 09/08/20Report date: 107 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions 6.4.3.1.1 [FI2]2 Heating and cooling to each zone is controlled by a thermostat control. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.1.2, 6.4.3.2, 6.4.3.3, 6.4.3.3.1, 6.4.3.3.2 [FI3]2 Thermostatic controls have a 5 °F deadband. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.5 [FI5]3 Heat pump controls prevent supplemental electric resistance heat from coming on when not needed. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: NOT APPLICABLE 6.4.3.5 [FI5]3 Heat pump controls prevent supplemental electric resistance heat from coming on when not needed. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: NOT APPLICABLE 6.4.3.7 [FI6]3 When humidification and dehumidification are provided to a zone, simultaneous operation is prohibited. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: NOT APPLICABLE 6.7.2.1 [FI7]3 Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.2 [FI8]3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.3 [FI9]1 An air and/or hydronic system balancing report is provided for HVAC systems serving zones >5,000 ft2 of conditioned area. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.7.2.4 [FI10]1 HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.2 [FI20]1 Temperature controls have setpoint overlap restrictions. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.3.1 [FI21]1 HVAC systems equipped with at least one automatic shutdown control. Complies Does Not Not Observable Not Applicable Requirement will be met. 6.4.3.3.2 [FI22]1 Setback controls allow automatic restart and temporary operation as required for maintenance. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Evans May Wealth P:\_2020 Projects\Leach and Russell - Monon on Main Second and Third Floor Buldout\COMCheck\Mechanical COMCheck 3rd Floor.cck 09/08/20Report date: 108 ofPage 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Evans May Wealth P:\_2020 Projects\Leach and Russell - Monon on Main Second and Third Floor Buldout\COMCheck\Mechanical COMCheck 3rd Floor.cck 09/08/20Report date: 109 ofPage Project Title: Data filename: Evans May Wealth P:\_2020 Projects\Leach and Russell - Monon on Main Second and Third Floor Buldout\COMCheck\Mechanical COMCheck 3rd Floor.cck 09/08/20Report date: 1010 ofPage