Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M003.0
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). September 21,2020 Liu, Xuegang Pages or sheets covered by this seal: I42888615 thru I42888634 My license renewal date for the state of Indiana is July 31, 2022. B20002764 Pyatt Builders - 149 TG - Lemos IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss GE01 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888615 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:09 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-qL6zLYc?ai2vQQsVrWiX04wqG8wtel36Oot7?MybT38 Scale = 1:69.3 1 2 3 4 5 6 7 8 9 10 11 12 23 22 20 19 18 17 16 15 14 13 24 55 56 57 58 21 59 60 3x6 4x8 3x4 3x6 4x8 3x4 3x6 3x6 2x4 3x6 2x4 3x8 3x4 3x8 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 9-4-8 9-4-8 15-10-0 6-5-8 18-5-8 2-7-8 27-10-0 9-4-8 -1-0-0 1-0-0 7-1-4 7-1-4 13-11-0 6-9-12 20-8-12 6-9-12 27-10-0 7-1-4 28-10-0 1-0-0 0-9-010-0-50-9-08.00 12 Plate Offsets (X,Y)-- [2:0-4-13,Edge], [7:0-1-8,0-1-8], [11:0-4-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.51 0.70 0.30 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.36 0.03 (loc) 23-49 23-49 2 l/defl >932 >521 n/a L/d 240 180 n/a PLATES MT20 Weight: 182 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 7-19,7-23: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-19 JOINTS 1 Brace at Jt(s): 24 REACTIONS.All bearings 12-3-8 except (jt=length) 2=0-3-8, 21=0-3-8. (lb) - Max Horz 2=-158(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 19, 11, 20, 14, 13 Max Grav All reactions 250 lb or less at joint(s) 20, 18, 17, 16, 15, 14, 13, 21 except 2=901(LC 17), 19=761(LC 1), 11=337(LC 1), 11=337(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-890/64, 4-5=-824/80, 5-7=-735/99 BOT CHORD 2-23=0/843, 21-23=0/486, 20-21=0/486, 19-20=0/343 WEBS 7-19=-469/0, 9-19=-376/132, 23-24=0/616, 7-24=0/615 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-11-0, Exterior(2R) 13-11-0 to 16-11-0, Interior(1) 16-11-0 to 28-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 19, 11, 20, 14, 13, 11. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss GE01A Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888616 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:12 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-Fwo5zaetsdRUHtb4XfFEejYLZMx9r6qY5m6nchybT35 Scale = 1:68.7 1 2 3 4 5 6 7 8 9 10 11 12 26 25 23 22 21 20 19 18 17 16 15 14 13 27 28 60 61 62 63 24 64 65 3x6 4x8 3x4 3x6 4x8 3x4 3x6 3x6 3x6 3x8 3x4 3x8 3x12 9-4-8 9-4-8 12-4-8 3-0-0 18-5-8 6-1-0 27-10-0 9-4-8 -1-0-0 1-0-0 7-1-4 7-1-4 13-11-0 6-9-12 20-8-12 6-9-12 27-10-0 7-1-4 28-10-0 1-0-0 0-9-010-0-50-9-08.00 12 Plate Offsets (X,Y)-- [2:0-4-9,0-0-3], [7:0-1-9,0-1-8], [11:0-4-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.50 0.66 0.30 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.19 -0.34 0.02 (loc) 26-54 26-54 2 l/defl >803 >448 n/a L/d 240 180 n/a PLATES MT20 Weight: 193 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 7-19,7-26: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 7-22: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-19 JOINTS 1 Brace at Jt(s): 27 REACTIONS.All bearings 15-5-8 except (jt=length) 2=0-3-8, 24=0-3-8. (lb) - Max Horz 2=-158(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 19, 11, 14, 13 except 24=-148(LC 16) Max Grav All reactions 250 lb or less at joint(s) 22, 21, 20, 18, 17, 16, 15, 14, 13 except 2=851(LC 17), 19=781(LC 1), 11=314(LC 24), 23=296(LC 16), 11=305(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-846/60, 4-5=-658/63, 5-7=-647/124 BOT CHORD 2-26=0/809, 24-26=0/553, 23-24=0/553, 22-23=0/306, 21-22=0/306, 20-21=0/306, 19-20=0/306 WEBS 7-19=-488/0, 9-19=-375/132, 26-27=-14/510, 7-27=-13/508, 5-28=-255/128, 23-27=-296/19, 27-28=-284/19 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-11-0, Exterior(2R) 13-11-0 to 16-11-0, Interior(1) 16-11-0 to 28-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 19, 11, 14, 13, 11 except (jt=lb) 24=148. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss GE02 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888617 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:13 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-j6LUAwfVdwZLv1AG4MmTAw5VhmJNabSiJQrK87ybT34 Scale = 1:42.1 1 2 3 4 5 6 7 8 12 11 10 9 13 30 31 32 33 3x8 3x4 4x8 4x6 2x4 4x6 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 7-11-0 7-11-0 15-10-0 7-11-0 -1-0-0 1-0-0 7-11-0 7-11-0 15-10-0 7-11-0 16-10-0 1-0-0 0-9-06-0-50-9-08.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [7:0-4-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.54 0.54 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.15 0.01 (loc) 12-24 12-24 2 l/defl >999 >917 n/a L/d 240 180 n/a PLATES MT20 Weight: 73 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x6 SPF No.2 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 13 REACTIONS.All bearings 5-6-8 except (jt=length) 2=0-3-8. (lb) - Max Horz 2=-93(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 11 except 10=-148(LC 24), 9=-123(LC 12) Max Grav All reactions 250 lb or less at joint(s) 11, 10 except 2=627(LC 1), 7=403(LC 1), 9=350(LC 24), 7=403(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-602/41, 4-5=-417/35, 5-7=-494/565 BOT CHORD 2-12=0/477, 11-12=0/474, 10-11=0/315, 9-10=0/315, 7-9=0/315 WEBS 12-13=0/277, 5-13=0/275 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-11-0, Exterior(2R) 7-11-0 to 10-11-0, Interior(1) 10-11-0 to 16-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11 except (jt=lb) 10=148, 9=123. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss GE03 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888618 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:15 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-fVTEbbgl9Yp38LJfCnoxFLAznZ7y2Xn?nkKRD0ybT32 Scale = 1:27.2 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 19 20 4x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 4x8 2x4 2x4 2x4 2x4 2x4 4x8 10-7-0 10-7-0 -1-0-0 1-0-0 5-3-8 5-3-8 10-7-0 5-3-8 11-7-0 1-0-0 0-9-04-3-50-9-08.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-0-3], [10:0-2-0,0-1-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.06 0.02 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 11 11 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-5-4, Right 2x4 SPF-S Stud 1-5-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-7-0. (lb) - Max Horz 2=-66(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 10, 16, 17, 18, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 2, 10, 15, 16, 17, 18, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 5-3-8, Corner(3R) 5-3-8 to 8-3-8, Exterior(2N) 8-3-8 to 11-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10, 16, 17, 18, 14, 13, 12. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss GE04 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888619 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:17 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-bub_0Hi0h93nNeT1JCrPLmFJHNoBWR_HE1pYHuybT30 Scale = 1:31.3 1 2 3 4 5 6 7 8 9 10 11 12 13 20 19 18 17 16 15 14 21 22 4x6 3x6 3x4 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 12-8-0 12-8-0 -1-0-0 1-0-0 6-4-0 6-4-0 12-8-0 6-4-0 13-8-0 1-0-0 0-9-04-11-110-9-08.00 12 Plate Offsets (X,Y)-- [2:0-4-1,0-0-3], [12:0-4-1,0-0-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.06 0.03 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 12 12 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 58 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-7-2, Right 2x4 SPF-S Stud 1-7-2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-8-0. (lb) - Max Horz 2=-76(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 12, 18, 19, 20, 16, 15, 14 Max Grav All reactions 250 lb or less at joint(s) 2, 12, 17, 18, 19, 20, 16, 15, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 6-4-0, Corner(3R) 6-4-0 to 9-4-0, Exterior(2N) 9-4-0 to 13-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 12, 18, 19, 20, 16, 15, 14. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss GE05 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888620 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:18 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-349NEdjeSTBe?o2EtvMet_oTun8BFuPRThZ5qKybT3? Scale = 1:38.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 31 30 29 28 27 26 25 24 23 22 21 20 19 18 32 33 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 21-8-0 21-8-0 -1-0-0 1-0-0 10-10-0 10-10-0 21-8-0 10-10-0 22-8-0 1-0-0 0-5-104-11-130-5-105.00 12 Plate Offsets (X,Y)-- [25:0-2-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.06 0.05 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 16 17 16 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 88 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 21-8-0. (lb) - Max Horz 2=-49(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 27, 28, 29, 30, 22, 21, 20, 19, 16 Max Grav All reactions 250 lb or less at joint(s) 2, 24, 26, 27, 28, 29, 30, 31, 23, 22, 21, 20, 19, 18, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 10-10-0, Corner(3R) 10-10-0 to 13-10-0, Exterior(2N) 13-10-0 to 22-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 27, 28, 29, 30, 22, 21, 20, 19, 16. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss GE06 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888621 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:19 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-YGjlRzkGDmJVdydQRdttQBLeqAT3_KAaiLIfMnybT3_ Scale = 1:19.2 1 2 3 4 5 6 7 12 11 10 9 8 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 8-7-8 8-7-8 0-4-83-3-04.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.12 0.07 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 1 1 8 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-7-8. (lb) - Max Horz 2=82(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 8, 2, 9, 11 Max Grav All reactions 250 lb or less at joint(s) 8, 2, 9, 10, 11 except 12=251(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 8-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2, 9, 11. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss GE06A Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888622 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:20 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-0SG7eJku_4RLE6Cc?KO6yPtpFaqWjnMkw?2CtDybT2z Scale = 1:14.8 1 2 3 4 5 8 7 6 3x4 3x4 3x4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 5-7-8 5-7-8 0-4-82-3-04.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.07 0.06 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-7-8. (lb) - Max Horz 2=55(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 2, 7 Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 5-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss GE07 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888623 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:21 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-UfqVsflWlOZCsGnoY2vLVcQ_f_9XSESt9fnlPfybT2y Scale = 1:15.4 1 2 3 4 5 8 7 6 3x4 3x4 3x4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 5-11-8 5-11-8 0-4-82-4-54.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.07 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-11-8. (lb) - Max Horz 2=58(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 7 Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7 except 8=251(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 5-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss GE07A Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888624 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:22 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-yrOt3?m8Whh3UQM?6lQa1qz9POVmBhf0OJXJy6ybT2x Scale = 1:12.3 1 2 3 4 6 5 3x4 3x4 3x4 2x4 2x4 -1-0-0 1-0-0 4-7-8 4-7-8 0-4-81-11-04.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.07 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=4-7-8, 2=4-7-8, 6=4-7-8 Max Horz 2=46(LC 9) Max Uplift 5=-15(LC 18), 2=-21(LC 12) Max Grav 5=1(LC 12), 2=179(LC 1), 6=251(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 4-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss M01 Truss Type Monopitch Qty 4 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888625 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:23 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-Q1yGHKnnH?pw5ZxBgSypa1VKMorhw8EAdzGsUYybT2w Scale = 1:11.4 2 41 3 3x4 -1-0-0 1-0-0 1-0-0 1-0-0 0-4-31-0-70-7-120-5-30-7-41-0-78.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.08 0.03 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 3=0-1-8 Max Horz 1=29(LC 12) Max Uplift 3=-9(LC 12) Max Grav 1=79(LC 1), 3=76(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss T01 Truss Type Common Qty 17 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888626 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:24 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-uEWeUgnP2JxnjjVNEAT27F2OFB_vfXvJrd0Q0_ybT2v Scale = 1:62.5 1 2 3 4 5 6 7 8 9 10 11 14 13 12 23 24 25 26 27 28 29 30 3x6 4x6 3x6 5x8 3x4 3x6 3x6 2x4 3x6 2x4 5x8 3x4 9-4-8 9-4-8 18-5-8 9-1-0 27-10-0 9-4-8 -1-0-0 1-0-0 7-1-4 7-1-4 13-11-0 6-9-12 20-8-12 6-9-12 27-10-0 7-1-4 28-10-0 1-0-0 0-9-010-0-50-9-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.52 0.86 0.29 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.23 -0.36 0.05 (loc) 12-14 12-14 10 l/defl >999 >938 n/a L/d 240 180 n/a PLATES MT20 Weight: 111 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 8-12,4-14: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=158(LC 11) Max Uplift 2=-2(LC 12), 10=-2(LC 12) Max Grav 2=1339(LC 17), 10=1339(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1674/40, 4-6=-1594/106, 6-8=-1594/106, 8-10=-1674/40 BOT CHORD 2-14=0/1457, 12-14=0/978, 10-12=0/1353 WEBS 6-12=-12/787, 8-12=-367/131, 6-14=-12/787, 4-14=-367/131 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-11-0, Exterior(2R) 13-11-0 to 16-11-0, Interior(1) 16-11-0 to 28-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss T01A Truss Type Roof Special Qty 3 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888627 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:25 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-MQ40i0o1oc3eLt4ant_HfSbYybQsOsTT4HlzYQybT2u Scale = 1:65.1 1 2 3 4 5 6 7 8 9 10 11 12 20 19 18 14 13 17 16 15 29 303x6 4x6 3x6 4x8 3x4 5x6 3x4 5x12 3x6 5x6 3x8 3x4 3x6 3x8 4x8 5x12 3x6 2x4 7-1-4 7-1-4 14-0-12 6-11-8 14-7-8 0-6-12 17-7-8 3-0-0 20-8-12 3-1-4 27-10-0 7-1-4 -1-0-0 1-0-0 7-1-4 7-1-4 13-11-0 6-9-12 17-7-8 3-8-8 20-8-12 3-1-4 27-10-0 7-1-4 28-10-0 1-0-0 0-9-010-0-50-9-02-0-08.00 12 Plate Offsets (X,Y)-- [2:0-4-13,Edge], [11:0-4-13,Edge], [13:0-3-8,0-2-0], [14:0-3-0,0-3-0], [15:0-6-8,0-4-4], [17:0-3-12,0-2-8], [18:0-3-0,0-3-0], [20:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.52 0.49 0.79 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.17 0.10 (loc) 15-16 19-20 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 136 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 7-14: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. Except: 10-0-0 oc bracing: 15-16, 14-15 JOINTS 1 Brace at Jt(s): 17, 15 REACTIONS. (size)2=0-3-8, 11=0-3-8 Max Horz 2=158(LC 11) Max Uplift 2=-2(LC 12), 11=-2(LC 12) Max Grav 2=1173(LC 1), 11=1173(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1514/28, 4-6=-1341/58, 6-7=-1270/65, 7-9=-1818/27, 9-11=-1500/29 BOT CHORD 2-20=0/1188, 11-13=0/1168, 17-19=0/312, 6-17=0/1028, 16-17=0/1459, 15-16=0/1465, 7-15=0/743 WEBS 17-20=0/1182, 4-17=-264/99, 7-17=-745/30, 13-15=0/1437, 9-15=0/410, 9-13=-770/2 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-11-0, Exterior(2R) 13-11-0 to 16-11-0, Interior(1) 16-11-0 to 28-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. DOTTED MEMBERS TO BE REMOVED CONNECTOR PLATES TO BE CUT CLEANLY AND ACCURATELY AND THE REMAINING PLATE MUST BE FULLY EMBEDDED AND UNDISTURBED. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss T02 Truss Type Common Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888628 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:26 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-qceOvMpfZwBVy1fmLbVWCg7h6?j17SPcJxVW5tybT2t Scale = 1:38.2 1 2 3 4 5 6 7 8 17 18 19 20 21 22 3x8 3x4 3x8 3x4 2x4 4x8 7-11-0 7-11-0 15-10-0 7-11-0 -1-0-0 1-0-0 7-11-0 7-11-0 15-10-0 7-11-0 16-10-0 1-0-0 0-9-06-0-50-9-08.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [6:0-4-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.69 0.69 0.23 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.21 0.05 (loc) 8-11 8-11 2 l/defl >999 >902 n/a L/d 240 180 n/a PLATES MT20 Weight: 52 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=-93(LC 10) Max Uplift 2=-11(LC 12), 6=-11(LC 12) Max Grav 2=781(LC 17), 6=781(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-791/64, 4-6=-791/64 BOT CHORD 2-8=0/630, 6-8=0/630 WEBS 4-8=0/451 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-11-0, Exterior(2R) 7-11-0 to 10-11-0, Interior(1) 10-11-0 to 16-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss T04 Truss Type Common Qty 1 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888629 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:27 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-JpCm6iqHKEJMaBEyvI0lktgwZP8zsw3mXbE4dJybT2s Scale = 1:31.5 1 2 3 4 5 6 7 8 17 18 3x6 3x4 3x6 3x4 2x4 4x6 6-4-0 6-4-0 12-8-0 6-4-0 -1-0-0 1-0-0 6-4-0 6-4-0 12-8-0 6-4-0 13-8-0 1-0-0 0-9-04-11-110-9-08.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-0-3], [6:0-3-9,0-0-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.39 0.32 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.07 0.02 (loc) 8-15 8-15 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0, Right 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=-76(LC 10) Max Uplift 2=-13(LC 12), 6=-13(LC 12) Max Grav 2=567(LC 1), 6=567(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-471/75, 4-6=-471/75 BOT CHORD 2-8=0/388, 6-8=0/388 WEBS 4-8=0/275 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-4-0, Exterior(2R) 6-4-0 to 9-4-0, Interior(1) 9-4-0 to 13-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss T05 Truss Type Common Qty 4 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888630 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:28 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-n?l9K2rv5XSDCLp9T0X_H5D6JpRhbLFvmF_d9lybT2r Scale = 1:37.9 1 2 3 4 5 6 7 10 9 8 11 12 13 14 4x6 3x6 3x6 3x6 2x4 3x6 2x4 3x6 7-4-0 7-4-0 14-4-0 7-0-0 21-8-0 7-4-0 -1-0-0 1-0-0 5-7-0 5-7-0 10-10-0 5-3-0 16-1-0 5-3-0 21-8-0 5-7-0 22-8-0 1-0-0 0-5-104-11-130-5-105.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-7], [6:0-0-0,0-0-7] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.32 0.55 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.19 0.04 (loc) 2-10 6-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 71 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=49(LC 11) Max Uplift 2=-10(LC 12), 6=-10(LC 12) Max Grav 2=924(LC 1), 6=924(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1636/102, 3-4=-1437/102, 4-5=-1437/102, 5-6=-1636/102 BOT CHORD 2-10=-42/1435, 8-10=0/977, 6-8=-44/1435 WEBS 4-8=0/495, 5-8=-304/108, 4-10=0/495, 3-10=-304/108 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 10-10-0, Exterior(2R) 10-10-0 to 13-10-0, Interior(1) 13-10-0 to 22-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss T06 Truss Type Monopitch Qty 7 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888631 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:29 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-FBJXXOrXsra4pUOL0j2DqIl8dCn9Kjl2?vjBiCybT2q Scale = 1:20.4 1 2 3 5 4 6 7 5x10 MT18HS 5x8 3x6 3x4 8-7-8 8-7-8 -1-0-0 1-0-0 8-7-8 8-7-8 0-4-83-3-01-6-23-3-04.00 12 Plate Offsets (X,Y)-- [2:Edge,0-0-9], [3:0-2-11,0-2-7], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.93 0.47 0.64 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.24 -0.01 (loc) 2-5 2-5 7 l/defl >944 >420 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 25 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-0, 7=0-1-8 Max Horz 2=64(LC 9) Max Uplift 2=-12(LC 12) Max Grav 2=409(LC 1), 7=317(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-313/39, 3-6=-465/382 WEBS 3-7=-242/257 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 7. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss T06A Truss Type MONOPITCH Qty 6 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888632 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:30 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-jOtvlksAd9ixRezXaRaSMWIR8cA13JzCEZTkEeybT2p Scale = 1:14.8 1 2 3 4 3x4 3x4 3x4 5-7-8 5-7-8 -1-0-0 1-0-0 5-6-0 5-6-0 5-7-8 0-1-8 0-4-82-3-01-11-80-3-82-3-04.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.43 0.30 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.10 0.00 (loc) 2-4 2-4 4 l/defl >999 >659 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=55(LC 11) Max Uplift 2=-23(LC 12) Max Grav 2=289(LC 1), 4=206(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss T07 Truss Type Monopitch Qty 2 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888633 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:31 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-BaRHy4toOSqo3oYj885hvjrd60YMoj8LSDCHm4ybT2o Scale = 1:17.1 1 2 3 6 5 4 7 8 5x6 3x4 3x6 3x4 3x4 5-9-10 5-9-10 -1-1-14 1-1-14 5-9-10 5-9-10 0-8-140-7-122-11-90-3-80-10-122-11-94.00 12 Plate Offsets (X,Y)-- [3:0-2-8,0-2-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.35 0.17 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 -0.01 (loc) 5-6 5-6 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-1-8, 8=0-1-8 Max Horz 6=55(LC 12) Max Uplift 6=-15(LC 12), 8=-2(LC 12) Max Grav 6=311(LC 1), 8=199(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-266/157 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-1-14 to 1-10-2, Interior(1) 1-10-2 to 5-5-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 6, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6, 8. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B20002764 Truss T07A Truss Type Monopitch Qty 5 Ply 1 Pyatt Builders - 149 TG - Lemos Job Reference (optional) I42888634 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Sep 21 08:25:32 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-fm?fAPuQ9myegy7wircwRxNqJQveXDSVhtyrIWybT2n Scale = 1:15.4 1 2 3 6 5 7 4 3x12 3x4 3x6 3x4 5-8-2 1-11-6-1-1-14 1-1-14 4-5-10 4-5-10 0-8-140-7-122-6-40-3-80-3-84.00 12 Plate Offsets (X,Y)-- [3:0-8-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.19 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.01 (loc) 5-6 5-6 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 6=0-1-8, 7=0-1-8 Max Horz 6=62(LC 9) Max Uplift 6=-28(LC 12) Max Grav 4=18(LC 3), 6=245(LC 1), 7=172(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-1-14 to 1-10-2, Interior(1) 1-10-2 to 4-2-2 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 6, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6, 7. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. September 21,2020 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths