HomeMy WebLinkAboutRefectedFinish_A121TILETILE AS SCHEDULED SILICONE TRIM PIECE (TR1) DRYWALL TILE AS SPECIFIED; SEE FINISH LEGENDEL EL REFLECTED CEILING PLAN & FINISH PLAN A121 REFLECTED CEILING PLANAREA NOT IN CONTRACT AREA OF WORK DESCRIPTIONDATE ISSUE 08.11.20 REVIEW SET 08.11.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR COMMONAREA REMODELTWO PENN MARK - 4TH FLOOR11555 N. MERIDIAN ST. CARMEL, IN 46032EHEH 2020.203 4TH FLOOR N0 2' 4' 8' 16' LIGHT CIRCUIT EXIT LIGHT FIXTURE RECESSED LIGHT FIXTURE LIGHT FIXTURE, 2'x2', LED, BUILDING STANDARD LIGHT FIXTURE, 2'x4', LED, BUILDING STANDARD EXISTING/RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES SALVAGED FROM DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. NEW OR RELOCATED EXISTING TO REMAIN EXIT LIGHT FIXTURE LIGHT CIRCUIT CEILING GRID, SUSPENDED, 2'x2' DIFFUSER, LAY-IN, 2'x2' LIGHT FIXTURE, 2'x2', PARABOLIC LIGHT FIXTURE, 2'x4', PRISMATIC RCP LEGEND RECESSED LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH EXHAUST FAN, 2'x2' EXISTING EXHAUST FAN, 2'x2' LIGHT FIXTURE, 4"x48'", FLUORESCENT, INDIRECT LIGHT FIXTURE, 4"x48", FLUORESCENT, INDIRECT 1. REUSE EXISTING CEILING GRID UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2; CEILING HEIGHTS VARY. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE CEILING TILES IN RESTROOMS WITH NEW BUILDING STANDARD TILES. COORDINATE WITH LANDLORD FOR SPECIFICATIONS. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 5. ALL EXISTING AND NEW SWITCHES AND FACE PLATES TO BE WHITE; REPLACE EXISTING WITH NEW AS REQUIRED. GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.  ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. GENERAL NOTES MECHANICAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED.  ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED;  MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. RCP PLAN NOTES PAINT EXISTING BULKHEAD IN PT1; FLAT FINISH. NEW LIGHT FIXTURES TO BE CONTROLLED BY EXISTING SWITCHES/ CIRCUITS. CONFIRM EXACT REQUIREMENTS WITH BUILDING MANAGER. CARPET FLOOR COVERINGS MFG: SHAW CONTRACT TYPE: MODULAR TILE PATTERN: OFFSET COLOR: MIRROR GRAY INSTALL: BRICK; MATCH 2ND FLOOR INSTALLATION WALL BASE MFG: JOHNSONITE TYPE: 4" VINYL COVE, 18" GAUGE COLOR: MOON ROCK 29 PAINT / WALL TILE MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: DORIAN GRAY SW7017 FINISH: EGGSHELL PLASTIC LAMINATE MFG: WILSONART COLOR: WHITE CARRARA 4924-38 ALL FINISHES TO BE SELECTED. FINISHES SHALL MEET ALL CLASS A FIRE RATINGS AND COMPLY WITH CHAPTER 8 OF INTERNATIONAL BUILDING CODE. FINISH LEGEND MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: DORIAN GRAY SW7017 FINISH: SEMI-GLOSS FLOOR TILE TRIM PEICES MFG: SCHLUTER (FINISH TRIM ATOP ALL TB1 LOCATIONS) STYLE: JOLLY COLOR: MATCH 2ND FLOOR NOTE: INSTALL ALL SCHLUTER EDGING TRIM PIECES TO BE FLUSH WITH ADJACENT TILE SURFACE, WITH NO OVERHANG.  CONTRACTOR RESPONSIBLE FOR SELECTING PROPER TRIM THICKNESS.  DESIGNER TO APPROVE SAMPLE PRIOR TO INSTALLATION. SEE DETAIL 1/A121 FOR MORE INFORMATION. MFG: SCHLUTER (VERTICAL TRIM FOR OUTSIDE CORNERS OF WT2) STYLE: JOLLY COLOR: MATCH 2ND FLOOR NOTE: INSTALL ALL SCHLUTER EDGING TRIM PIECES TO BE FLUSH WITH ADJACENT TILE SURFACE WITH NO OVERHANG.  CONTRACTOR RESPONSIBLE FOR SELECTING PROPER TRIM THICKNESS.  DESIGNER TO APPROVE SAMPLE PRIOR TO INSTALLATION. MFG: SHERWIN WILLIAMS (METAL DOORS & DOOR FRAMES) PRIMER: PRO-CRYL TOP COAT: PRO INDUSTRIAL RECATALYZED WATERBASED EPOXY K46W151 COLOR: GAUNTLET GRAY SW7019 FINISH: SEMI-GLOSS INSTALL: PREP AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS FOR MAXIMUM ADHESION. THIS INCLUDES CLEANING AND SCUFF SANDING PRIOR TO APPLYING NEW FINISH. APPLY USING SPRAY APPLICATION. NOT TO SCALE DETAIL - WALL TILE TRIM A121 1 FINISH PLAN NOTES PROVIDE SCHLUTER SCHIENE TRANSITION STRIP AT CARPET TO TILE TRANSITION, FINISH: BRUSHED STAINLESS STEEL (EB). PROVIDE LEVELING LATEX UNDER CARPET AS SUCH THAT TOP OF FINISHES ARE LEVEL. SEAM SEAL CARPET EDGES. TRANSITION STRIP MUST BE LEVEL WITH OR SLIGHTLY HIGHER THAN TILE EDGE. CONTRACTOR TO CONFIRM THAT TRANSITION PROFILE MUST IS APPROPRIATE FOR FLOORING MATERIALS. PREP METAL DOOR AND FRAME ON BOTH SIDES TO RECEIVE PAINT (PT3). REPLACE ALL EXISTING BRASS HARDWARE WITH NEW BRUSHED CHROME. PREP METAL FRAME ONLY ON CORRIDOR SIDE TO RECEIVE PAINT (PT3). WOOD DOOR TO BE PREPPED AND REPAINTED PT4 ON COMMON CORRIDOR SIDE. REPLACE ALL EXISTING BRASS HARDWARE WITH NEW BRUSHED CHROME. PREP METAL DOOR AND FRAME ON CORRIDOR SIDE AND RESTROOM SIDE TO RECEIVE PAINT (PT3). REPLACE ALL EXISTING BRASS HARDWARE WITH NEW BRUSHED CHROME. HARDWARE FUNCTION TO BE SAME AS EXISTING. PREP ELEVATOR DOORS AND FRAMES AS REQUIRED TO ACHIEVE MAXIMUM ADHESION FOR PAINT (PT3). INSTALL WALL TILE (WT1) FROM FLOOR TO CEILING AT THIS LOCATION. 1. REFER TO LEGEND FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 2. CONTRACTOR TO EVALUATE EXISTING FLOORING CONDITIONS AFTER DECONSTRUCTION IS COMPLETE AND PREP AS NECESSARY PER MANUFACTURERS RECOMMENDATIONS. SEALCOAT THE CONCRETE FLOOR PRIOR TO LAYING ADHESIVE IF DEEMED NECESSARY. 3. AT ALL FLOOR TILE LOCATIONS PROVIDE WATERPROOFING CRACK ISOLATION MEMBRANE:  TEC HYDRAFLEX FULL COVERAGE PER TCNA F125-11 FULL. PROVIDE CONTROL JOINTS EVERY 12' AT MINIMUM OR AS RECOMMENDED BY MANUFACTURER. 4. AT NEW WALL TILE LOCATIONS PROVIDE APPROPRIATE SUBSTRATE FOR WALL TILE (AT EXISTING WALLS SCHLUTER KERDI BOARD OR EQUAL) (AT NEW WALLS CEMENT BACKER BOARD) AS RECOMMENDED BY MANUFACTURER. 5. PAINT ALL CEILING TRIM IN COMMON CORRIDOR TO MATCH ADJACENT WALL COLOR. GENERAL FINISH NOTES FINISH PLAN 0 2' 4' 8' 16' AREA NOT IN CONTRACT AREA OF WORK MFG: PIONITE COLOR: SLATE SG228 MFG: SHERWIN WILLIAMS PRIMER: MULTI-PURPOSE LATEX PRIMER B51W450 TOP COAT: SOLO COLOR: GAUNTLET GRAY SW7019 FINISH: SEMI- GLOSS INSTALL: PREP AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS FOR MAXIMUM ADHESION. THIS INCLUDES CLEANING AND SCUFF SANDING PRIOR TO APPLYING NEW FINISH. APPLY USING SPRAY APPLICATION. MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: JUBILEE SW6248 FINISH: SEMI-GLOSS MFG: SHERWIN WILLIAMS TYPE: PROMAR 200 ZERO VOC INTERIOR LATEX COLOR: INCREDIBLE WHITE SW7028 FINISH: EGGSHELL MFG: CROSSVILLE - LOUISVILLE TILE SIZE: 12X24 STYLE: JAVA JOINT COLOR: HOUSE BLEND GROUT: 3/16" WIDTH, TEC POWER GROUT AND ULTIMATE MORTAR, COLOR SILHOUETTE INSTALL METHOD: 13 OFFSET. LENGTH OF TILE TO RUN IN DIRECTION OF ARROWS ON PLAN. NOTE: USE TL1 + TR1 AS WALL BASE. ALIGN GROUT LINES WHERE TILE BASE MEETS FLOOR. MFG: CROSSVILLE - LOUISVILLE TILE SIZE: 12X24, CUT DOWN TO 6X24 STYLE: JAVA JOINT COLOR: HOUSE BLEND GROUT: 3/16" WIDTH, TEC POWER GROUT AND ULTIMATE MORTAR, COLOR SILHOUETTE NOTE: ALIGN GROUT LINES WHERE TILE BASE MEETS FLOOR. MFG: CROSSVILLE - LOUISVILLE TILE SIZE: 12X24 STYLE: JAVA JOINT COLOR: HOUSE BLEND GROUT: 3/16" WIDTH, TEC POWER GROUT AND ULTIMATE MORTAR, COLOR SILHOUETTE INSTALL METHOD: 13 OFFSET. PLANKS TO RUN HORIZONTALLY ON WALL TO 4'-0" AFF. NOTE: WHERE POSSIBLE, ALIGN GROUT LINES WHERE WALL TILE MEETS FLOOR. 10/13/20