HomeMy WebLinkAboutElectricalArch_A111CORRIDOR
401
WOMEN'S
RR
402
MEN'S
RR
403
FE
FE
ARCHITECTURAL &
ELECTRICAL PLAN
A111
ARCHITECTURAL & ELECTRICAL PLANAREA NOT IN CONTRACT
AREA OF WORK
WALL
DOOR AND FRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHTWINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL
PARTIAL HEIGHT WALL
DESCRIPTIONDATE
ISSUE
08.11.20 REVIEW SET
08.11.20 PERMIT SET
REVISIONS
DESCRIPTIONMARK DATE DB
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR COMMONAREA REMODELTWO PENN MARK - 4TH FLOOR11555 N. MERIDIAN ST. CARMEL, IN 46032EHEH
2020.203
4TH FLOOR
N0 2' 4' 8' 16'
DECONSTRUCTION PLAN
REMOVE EXISTING COUNTERTOP.
REMOVE EXISTING SINK AND FAUCET. NO SERVICE SINKS ARE
BEING REMOVED. NEW SINKS TO BE IN SAME LOCATION; REUSE
EXISTING PLUMBING IF POSSIBLE.
REMOVE EXISTING CEILING TILE IN THIS ROOM; EXISTING CEILING
GRID TO REMAIN. REFER TO REFLECTED CEILING PLAN FOR
ADDITIONAL INFORMATION.
REMOVE EXISTING PLUMBING FIXTURES. SALVAGE FOR REUSE IN
SAME LOCATION. REFER TO SHEET A141 FOR ADDITIONAL
INFORMATION. REUSE EXISTING PLUMBING IF POSSIBLE.
REMOVE EXISTING HAND DRYER. PATCH WALL AND PREPARE FOR
NEW FINISHES AS REQUIRED.
REMOVE ALL EXISTING RESTROOM ACCESSORIES AND SALVAGE
FOR REUSE, UNLESS OTHERWISE NOTED. REFER TO SHEET A141 FOR
ADDITIONAL INFORMATION.
EXISTING DRINKING FOUNTAIN TO REMAIN.
REMOVE EXISTING TOILET PARTITIONS. NEW PARTITIONS TO BE IN
SAME LOCATION AS EXISTING; REFER TO A141 FOR MORE
INFORMATION.
DECON. PLAN NOTES
ELECTRIC OUTLET(S)
DATA OR
COMMUNICATION
OUTLET
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHT
WALL
DOOR AND FRAME
SUPPLY AIR DIFFUSERS
LIGHT FIXTURE,
FLUORESCENT, 2'x4'
LIGHT FIXTURE, CAN
LIGHT SWITCH
LIGHT FIXTURE,
FLUORESCENT, 2'x2'
WINDOW / SIDELIGHT
CEILING GRID AND
TILES, 2'x2'
LIGHT FIXTURE,
PENDANT
EXIT LIGHT
DECONSTRUCTION LEGEND
AREA NOT IN CONTRACT
AREA OF WORK
DECONST. PLAN/
PARTIAL HEIGHT WALLPARTIAL HEIGHT WALL
ARCH. PLAN NOTES
0 2' 4' 8' 16'
GENERAL ELEC. NOTES
1. ALL EXISTING FACE PLATES TO BE WHITE. REPLACE WITH
NEW AS REQUIRED.
2. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE
AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL
WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF
ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT
EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL
SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS
REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED
AND MUST COMPLY WITH ALL APPLICABLE CODES.
3. NO ELECTRICAL WORK NEEDED; UNLESS OTHERWISE
NOTED.
CONTRACTOR TO CONFIRM IF THERE IS AN EXISTING FIRE
EXTINGUISHER. IF SO, EXISTING TO REMAIN IF IN PROPER WORKING
ORDER. IF NOT, NEW FIRE EXTINGUISHER TO BE PROVIDED AND
INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE
INSTALLED ACCORDING TO NFPA 10.
PROVIDE DUROCK BRAND CEMENT BOARD ON EXISTING WET
WALLS AS REQUIRED.
REFER TO DETAIL 3/A141 FOR MORE INFORMATION ON NEW
COUNTERTOP.
_______________________________________________________________
REUSE EXISTING POTABLE HOT AND COLD WATER AND SANITARY
WASTE AND VENT PIPING FOR SINKS.
REUSE EXISTING COLD WATER SUPPLY AND WATER LINES AS
REQUIRED WHERE SALVAGED TOILETS AND URINAL ARE
REINSTALLED. PLUMBING FIXTURES ARE TO BE REINSTALLED AFTER
NEW FINISHES ARE COMPLETE.
1. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T111.
2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE
CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR
SALVAGED FOR LANLORD. FOR ALL ITEMS DETERMINED FOR
REMOVAL, REFER TO THE RECYCLING INSTRUCTIONS.
3. REMOVE EXISTING SIGNAGE THROUGHOUT CORRIDOR.
SALVAGE FOR REUSE IN SAME LOCATION.
DECON. GENERAL NOTES
RECYCLING INSTRUCTIONS
METALS ONLY RECYCLING BIN:
1. CONTACT WASTE HAULER TO ORDER TRASH DUMPSTER(S) AS
REQUIRED AND (1) "METALS ONLY" RECYCLING BIN FOR THE
DEMOLITION PORTION OF PROJECT ONLY. SIZE OF "METALS ONLY"
BIN IS DETERMINED BY THE AMOUNT OF DEMOLITION (10-40 YARD
CONTAINERS AVAILABLE).
2. DRYWALL MUST BE REMOVED FROM ALL METAL STUDS PRIOR TO
PLACING IN "METALS ONLY" BIN. ANY ADDED LABOR COST WILL BE
COVERED BY METAL CREDITS RECEIVED FROM WASTE HAULER.
3. WASTE HAULER WILL APPLY CREDIT FOR METALS OBTAINED IN
"METALS ONLY" BIN TOWARDS CONTRACTORS OVERALL INVOICE.
4. DATA/DIVERSION REPORTS ARE NOT REQUIRED NOR ANY LEED
PROCESSES OR PAPERWORK.
APPROVED METAL ITEMS:
5. METAL STUDS, DOOR FRAMES, DOOR HARDWARE, CEILING GRID,
LIGHT BOX FIXTURES, METAL CABINETS, METAL PLUMBING FIXTURES,
ELECTRICAL AND DATA WIRING/CONDUIT, HVAC COMPONENTS,
AND ELECTRICAL/DATA/SWITCH BOXES
CARPET RECYCLING:
6. CONTACT KRUSE CARPET RECYCLING TO SCHEDULE DROP OFF OF
ALL CARPET BEING REMOVED (BROADLOOM AND CARPET TILE).
COORDINATE REQUIREMENTS WITH SUSAN SHAFER (317) 337-1950.
DEMOLITION CREW IS NOT RESPONSIBLE FOR KRUSE SERVICE FEES
AND WILL ALSO RECOGNIZE A SAVINGS BY NO LONGER PAYING
HAULING/TIPPING FEES ON CARPET DISPOSAL WITH WASTE
HAULER.
7. KRUSE WILL PROVIDE AN ON-SITE BIN ON DAYS REQUIRED.
DEMOLITION CREW IS TO PLACE CARPET DIRECTLY INTO BIN; DOES
NOT NEED TO BE PALLETIZED. CONTRACTOR IS RESPONSIBLE FOR
KEEPING BINS CLEAN AND DRY AS TO NOT CONTAMINATE
CONTENTS.
8. KRUSE PICK UP AND RECYCLING FEES ARE TO BE PAID THROUGH
SCHOTT DESIGN'S "NO COST ADD PROGRAM". CARPET
MANUFACTURER IS TO PAY $1.00 PER SQUARE YARD FOR CARPET
RECYCLING BY REDUCING PRICE OF CARPET MATERIAL BY $1.00.
FLOORING CONTRACTOR IS RESPONSIBLE FOR DEDUCTING
MATERIAL PRICE AND PAYING $1.00 PER SQUARE YARD TO KRUSE.
SCHOTTXCHANGE:
9. CONTACT SCHOTTXCHANGE BEFORE DEMOLITION OF ITEMS THAT
CANNOT BE RECYCLED OR SALVAGE FOR LANDLORD.
SCHOTTXCHANGE CONSIDERS: DOORS, GLASS WINDOW SYSTEMS,
CABINETS, DECORATIVE LIGHTS, AND FURNITURE. IF ITEMS ARE
ACCEPTED FOR OUR INVENTORY, COORDINATE PICKUP AFTER
DEMOLITION WITH EMILY HILLYER (317) 762-7840 AT
SCHOTTXCHANGE AT NO COST TO THE PROJECT.
CONTACT EMILY HILLYER (317) 762-7840 AT SCHOTT DESIGN FOR ANY
QUESTIONS REGARDING THE RECYCLING PROCESSES.
A141
5
10/13/20