HomeMy WebLinkAboutElectricalArch_A111CORRIDOR 401 WOMEN'S RR 402 MEN'S RR 403 FE FE ARCHITECTURAL & ELECTRICAL PLAN A111 ARCHITECTURAL & ELECTRICAL PLANAREA NOT IN CONTRACT AREA OF WORK WALL DOOR AND FRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHTWINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL DESCRIPTIONDATE ISSUE 08.11.20 REVIEW SET 08.11.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR COMMONAREA REMODELTWO PENN MARK - 4TH FLOOR11555 N. MERIDIAN ST. CARMEL, IN 46032EHEH 2020.203 4TH FLOOR N0 2' 4' 8' 16' DECONSTRUCTION PLAN REMOVE EXISTING COUNTERTOP. REMOVE EXISTING SINK AND FAUCET. NO SERVICE SINKS ARE BEING REMOVED. NEW SINKS TO BE IN SAME LOCATION; REUSE EXISTING PLUMBING IF POSSIBLE. REMOVE EXISTING CEILING TILE IN THIS ROOM; EXISTING CEILING GRID TO REMAIN. REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATION. REMOVE EXISTING PLUMBING FIXTURES. SALVAGE FOR REUSE IN SAME LOCATION. REFER TO SHEET A141 FOR ADDITIONAL INFORMATION. REUSE EXISTING PLUMBING IF POSSIBLE. REMOVE EXISTING HAND DRYER. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. REMOVE ALL EXISTING RESTROOM ACCESSORIES AND SALVAGE FOR REUSE, UNLESS OTHERWISE NOTED. REFER TO SHEET A141 FOR ADDITIONAL INFORMATION. EXISTING DRINKING FOUNTAIN TO REMAIN. REMOVE EXISTING TOILET PARTITIONS. NEW PARTITIONS TO BE IN SAME LOCATION AS EXISTING; REFER TO A141 FOR MORE INFORMATION. DECON. PLAN NOTES ELECTRIC OUTLET(S) DATA OR COMMUNICATION OUTLET EXISTING TO BE REMOVED EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHT WALL DOOR AND FRAME SUPPLY AIR DIFFUSERS LIGHT FIXTURE, FLUORESCENT, 2'x4' LIGHT FIXTURE, CAN LIGHT SWITCH LIGHT FIXTURE, FLUORESCENT, 2'x2' WINDOW / SIDELIGHT CEILING GRID AND TILES, 2'x2' LIGHT FIXTURE, PENDANT EXIT LIGHT DECONSTRUCTION LEGEND AREA NOT IN CONTRACT AREA OF WORK DECONST. PLAN/ PARTIAL HEIGHT WALLPARTIAL HEIGHT WALL ARCH. PLAN NOTES 0 2' 4' 8' 16' GENERAL ELEC. NOTES 1. ALL EXISTING FACE PLATES TO BE WHITE. REPLACE WITH NEW AS REQUIRED. 2. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 3. NO ELECTRICAL WORK NEEDED; UNLESS OTHERWISE NOTED. CONTRACTOR TO CONFIRM IF THERE IS AN EXISTING FIRE EXTINGUISHER. IF SO, EXISTING TO REMAIN IF IN PROPER WORKING ORDER. IF NOT, NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE DUROCK BRAND CEMENT BOARD ON EXISTING WET WALLS AS REQUIRED. REFER TO DETAIL 3/A141 FOR MORE INFORMATION ON NEW COUNTERTOP. _______________________________________________________________ REUSE EXISTING POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REUSE EXISTING COLD WATER SUPPLY AND WATER LINES AS REQUIRED WHERE SALVAGED TOILETS AND URINAL ARE REINSTALLED. PLUMBING FIXTURES ARE TO BE REINSTALLED AFTER NEW FINISHES ARE COMPLETE. 1. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET T111. 2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR SALVAGED FOR LANLORD. FOR ALL ITEMS DETERMINED FOR REMOVAL, REFER TO THE RECYCLING INSTRUCTIONS. 3. REMOVE EXISTING SIGNAGE THROUGHOUT CORRIDOR. SALVAGE FOR REUSE IN SAME LOCATION. DECON. GENERAL NOTES RECYCLING INSTRUCTIONS METALS ONLY RECYCLING BIN: 1. CONTACT WASTE HAULER TO ORDER TRASH DUMPSTER(S) AS REQUIRED AND (1) "METALS ONLY" RECYCLING BIN FOR THE DEMOLITION PORTION OF PROJECT ONLY. SIZE OF "METALS ONLY" BIN IS DETERMINED BY THE AMOUNT OF DEMOLITION (10-40 YARD CONTAINERS AVAILABLE). 2. DRYWALL MUST BE REMOVED FROM ALL METAL STUDS PRIOR TO PLACING IN "METALS ONLY" BIN. ANY ADDED LABOR COST WILL BE COVERED BY METAL CREDITS RECEIVED FROM WASTE HAULER. 3. WASTE HAULER WILL APPLY CREDIT FOR METALS OBTAINED IN "METALS ONLY" BIN TOWARDS CONTRACTORS OVERALL INVOICE. 4. DATA/DIVERSION REPORTS ARE NOT REQUIRED NOR ANY LEED PROCESSES OR PAPERWORK. APPROVED METAL ITEMS: 5. METAL STUDS, DOOR FRAMES, DOOR HARDWARE, CEILING GRID, LIGHT BOX FIXTURES, METAL CABINETS, METAL PLUMBING FIXTURES, ELECTRICAL AND DATA WIRING/CONDUIT, HVAC COMPONENTS, AND ELECTRICAL/DATA/SWITCH BOXES CARPET RECYCLING: 6. CONTACT KRUSE CARPET RECYCLING TO SCHEDULE DROP OFF OF ALL CARPET BEING REMOVED (BROADLOOM AND CARPET TILE). COORDINATE REQUIREMENTS WITH SUSAN SHAFER (317) 337-1950. DEMOLITION CREW IS NOT RESPONSIBLE FOR KRUSE SERVICE FEES AND WILL ALSO RECOGNIZE A SAVINGS BY NO LONGER PAYING HAULING/TIPPING FEES ON CARPET DISPOSAL WITH WASTE HAULER. 7. KRUSE WILL PROVIDE AN ON-SITE BIN ON DAYS REQUIRED. DEMOLITION CREW IS TO PLACE CARPET DIRECTLY INTO BIN; DOES NOT NEED TO BE PALLETIZED. CONTRACTOR IS RESPONSIBLE FOR KEEPING BINS CLEAN AND DRY AS TO NOT CONTAMINATE CONTENTS. 8. KRUSE PICK UP AND RECYCLING FEES ARE TO BE PAID THROUGH SCHOTT DESIGN'S "NO COST ADD PROGRAM". CARPET MANUFACTURER IS TO PAY $1.00 PER SQUARE YARD FOR CARPET RECYCLING BY REDUCING PRICE OF CARPET MATERIAL BY $1.00. FLOORING CONTRACTOR IS RESPONSIBLE FOR DEDUCTING MATERIAL PRICE AND PAYING $1.00 PER SQUARE YARD TO KRUSE. SCHOTTXCHANGE: 9. CONTACT SCHOTTXCHANGE BEFORE DEMOLITION OF ITEMS THAT CANNOT BE RECYCLED OR SALVAGE FOR LANDLORD. SCHOTTXCHANGE CONSIDERS: DOORS, GLASS WINDOW SYSTEMS, CABINETS, DECORATIVE LIGHTS, AND FURNITURE. IF ITEMS ARE ACCEPTED FOR OUR INVENTORY, COORDINATE PICKUP AFTER DEMOLITION WITH EMILY HILLYER (317) 762-7840 AT SCHOTTXCHANGE AT NO COST TO THE PROJECT. CONTACT EMILY HILLYER (317) 762-7840 AT SCHOTT DESIGN FOR ANY QUESTIONS REGARDING THE RECYCLING PROCESSES. A141 5 10/13/20