HomeMy WebLinkAboutM001.0Indiana 2�2fl Performan�e �omplian�e
Praperty
7128 CHERRY CREEK 6LVD
CARMEL, IN 46033
Madel: STDCKBRIaGE
Cammunity: THE GROVEAT LEGA[
THE GROVE AT LEGACY 198A
GL198A �A5 ❑E51GNE�}
❑rganixatian
TSI Energy Solutions
❑evin Sielschott
6uilder
PYATT 6lJILQERS, LLC
Ins e�tion 5tatus _ T���nergyS�lutir�ns
p
Results are projected
This report is based an a proposed design and does not �anfirm field enforcement of design elements.
Annual Energy Cost
Design
Heating
Cooling
Water Heating
Mechanical Ventilation
SubTotal - Used to determine �omplian�e
Lights & Appliances wlout Ventilation
�nsite generation
Total
Indiana 2020 Performance
$i,a45
$1�2
$313
$33
$1,562
$592
$�
$2,154
Requirements
�
�
�
�
�
�
�
�
11D5
11 D2.4.12
11 D2.5
11 D2.5
11 D4.1
fAandatory Checklist
11 D3.6
11 D3.6.1
Performance-based compliance passes by 1.5°:0
Air Leakage Testing
Area-weighted a�erage fenestration SHGC
Area-weighted a�erage fenestration Ll-Factor
Lighting Equipment Efficiency
hlandatory code requirements that are not
checked by Ekotrope must be met.
Mechanical Ventilation Rate
hlechanical Ventilation Efficacy
As Qesigned
��,a��
$192
$313
$12
$1,539
$592
$d
$2,'131
Air sealing is 4.50 AGH at 50 Pa. It must not exceed 5.0� ACH at 5a Pa.
Design exceeds requirements fvr Indiana �Q20 Perfvrmance compliance hy 1.5°Io.
As a 3rd party extension of the code jurisdi�tion utilizing these reports. I certify that this energy code compliance document has been created in accordan�e with the requirements of
Chapter 4 of the adopted Intemational Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the huilding design des�ribed herein is consistent with
the building plans, specifications, and other �al�ulations submitted titiith the permit application. If rating is Confirmed, I �ertiTy that the address referenced above has been
inspected.+tested and that the mandatory pro�isions of the IECC have 6een installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name
Drganization
Devin Sielschott
T51 Energy Salutians
5ignature:
aate: 8f28120 a# 1:32 PM
Ekatrape RATER - Versian 3.2.3.2513
Indiana 2�20 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm, including appropriate amendmen[s.
Ekatrope RATER is a RESNET '�ccredited HERS Rating Tool. All results are 6ased on data entered 6y Ekotrope users.
Ekotrope disclaims all lia6ility for the information shown on this report.
7'I�S CHERRY CREEK BLVD
Ceiling Attic, R-38
1�1•" t:l*f:t�]'�:T C-f'i'Fl I� Cai 67
7+17iii'.FTiC•i7'i'F11�►1►,1
Framed Floar N!A
51ab R-1�.0 Perirneter, R-1D.0
Under
Ilnfiltration 4.5 ACHS�
Window U-Valu�: fl.31, SHGC: 0.3
Building Features
Duct Supply R-25.0, Return R-25.0
Duct Leakage to Outside 4 CFM25! 10� ft2
Total Duct Leakage 8 CFM251 10� ft2 (Past-Canstruction}
Heating Furnace • IVatural Gas • 92.1 AFIJE
Cooling Air Canditianer • Electri� • 13 SEER
Water Heating Water Heater • Electri� • 0.93 Energy Factor
As a 3rtl par[y extension of the code junsdf�tfon utflizing these reports, I certffy that this energy �ode compliance document has been created in a��ortlan�e ��tiith the requirements of
Chapter 4 of the adopted International Energy Conservation Code dased on Climate Zone 5. If rating is Projected, I certify that the building design descrided herein is consistent t�ith the
building plans; specifications, and other calculations submitted with the permit appli�ation. If rating is Confrmed; I certify that the address referenced ahove has been inspected.+tested and
that the mardatory �rovisions of the IECC have been installed to meet or exceed the intent ofthe IECC or v,�ill be verifed as such by another party.
Name: Devin 5ielschott
Si�r�ature:
Organization: TSI Energy Solutions aate: 81�8120 at 1:32 PM
- Version 3.2.3.2513
I�dia�a 2�2C �e�t�fcate compliance results calculated using Ekotrope RATER's energy and code compliance algarithm. including appropriate amendinents.
-4;o:rope �=.TER is a R-SNETHcc-editad HERS Rat rg Tool. =.1 resul:s a•e based o� data entered h•y Ekat•ooe use•s.
-�o i��:= :is=1a -ia a lial: :.: i� t a in-c n a ic� a�:�::n o� 1� s r=��c t
CARM E L, I N 4G833
6uilder: PYATT BUILDERS, LLC
Madel: ST�CKBRIDGE �ammunity: THE GR�VE AT LEGACY 198A
This repart is based an a propased design and does nat confirm field enfarGement of design elements.
Energy �ode Inspection Checklist
Property ❑rganixatian
7128 CHERRY CREEK 6LVD TSI Energy Solutions
CARMEL, IN 46033 ❑evin Sielschott
Madel: STDCKBRIaGE
Cammunity: THE GROVEAT LEGA[ 6uilder
PYATT 6lJILQERS, LLC
THE GROVE AT LEGACY 198A
GL198A �A5 ❑E51GNE�}
�eneral Building Infvrmatian
Conditioned Area �sq ft}
Canditioned Valume (�ubic ft)
Insulated 5hell Area (sq fty
2,267
23,D98
6,873
Ins e�tion 5tatus _ T���nergyS�lutir�ns
p
Results are projected
The building energy model in Ekatrope reflects the building assemhlies and energy features listed below. Sametimes energy
features will �hange in the field frorn what has been modeled. The inspection pro�ess should identify any �hanges and ensure
that the home continues to meet the applicable energy code.
51ab
� Name: SLAB(1,685 s.f., 1�6 ft. exterior perirneter}
R-10 perimeter insulation, R-10 under slab insulation.
Framed Flvar
Nane Present
Faundation Wall
Nane Present
Abvve �rade Wall
1� Name: C�NDlAM6 �2,501 s.f.}
a--� R-0 continuous insulation, R-15 cavity insulatian
Insulation Grade: I
1� Name: C�N DlGAR �63D s.f. y
a--� R-0 continuous insulation, R-15 cavity insulatian
Insulation Grade: I
� Name: CaNDlATTIC �212 s.f.}
R-a continuous insulation, R-15 cavity insulatian
Insulation Grade: I
� Name: C�NDlCDNa (160 s.f.}
R-a continuous insulation, R-22 cavity insulatian
Insulation Grade: I
Energy �ode Inspection Checklist
Property ❑rganixatian
7128 CHERRY CREEK 6LVD TSI Energy Solutions
CARMEL, IN 46033 ❑evin Sielschott
Madel: STDCKBRIaGE
Cammunity: THE GROVEAT LEGA[ 6uilder
PYATT 6lJILQERS, LLC
THE GROVE AT LEGACY 198A
GL198A �A5 ❑E51GNE�}
Rim Jaist
Nane Present
Ceiling 1 Rvvf
1� Name: MAI N� 1,685 s.f. y
�--� R-27.�5 continuaus insulation, R-1 D.15 �avity insulation
Insulation Grade: I
Dpaque Daar
� Name: FR�NT (20 s.f.}
U: 0.182
� Name: GARAGE (18 s.f.}
U: 0.182
�lazing
Inspe�tion 5tatus
Results are projected
� Name: FR�NT (60 s.f.}, U: D.310, SHGC: 0.3, �rientation: N�RTH
� Name: SLIDER (120 s.f.}, U: 0.310, SHGC: 0.3, Drientatian: S�UTH
1� Name: BAGK (168 s.f.}, Ll: D.31 D, SHGC: 0.3, �rientatian: SDUTH
a--G
� Name: LEFT SIaE �1�9 s.f.}, lJ: 0.310, SHGC: D.3, Drientation: EAST
� Name: SLIDER (48 s.f.J, U: 0.310, SHGC: a.3, Orientation: EAST
� Name: RIGHT 51�E �34 s.f.}, lJ: 0.310, SHGC: 0.3, ❑rientation: WEST
5kylight
Nane Present
+ TS��nergyS�lutir�ns
2
Mechanical Ventilativn
Energy �ode Inspection Checklist
Property ❑rganixatian
7128 CHERRY CREEK 6LVD TSI Energy Solutions
CARMEL, IN 46033 ❑evin Sielschott
Madel: STDCKBRIaGE
Cammunity: THE GROVEAT LEGA[ 6uilder
PYATT 6lJILQERS, LLC
THE GROVE AT LEGACY 198A
GL198A �A5 ❑E51GNE�}
Inspe�tion 5tatus
Results are projected
1� Mechanical ventilatian system rated for, and capable of, providing continuous �entilation.
�--� System shall include automatic timing controls.
System type: Exhaust �nly, 24 hrslday, 141Natts
IVlechanical Equipment
�
�!
!!!
Fuel-fired air distribution • Natural Gas • 10D°Io Heating Load �a 92.1 AFUE
Air conditioner • Electric � 100°Io Cooling Load @ 13 SEER
Water Heating • Electri� • 10D°Io Hat Water Load �7a 0.93 Energy Fact�r
Air Leakage Cvntral
1� Test Status: 6lower-door tested
a--� House is air-sealed as to achieve 1,732 CFM50 �4.50 AGH50) ar less at final blower-door test.
Infiltration Requirements for IECC in Climate Zone 5
2a09 IECC Infiltration limit f�r the design hame is 7 ACHS�.
2a12 IECC Infiltratian limit for the design hame is 3 ACHS�.
2a15 IECC Infiltration limit for the design home is 3 ACHS�.
2a18 IECC Infiltration limit for the design hame is 3 ACHS�.
Duct Leakage
Duct System 1
NOT entirely within conditioned spa�e, testing required
Leakage to ❑utside specified as: � CFM251 1 DD ftz
Total Leakage spe�ified as: 8 CFM251 1D� ft2 �Post-Constru�tion}
+ TS��nergyS�lutir�ns
3
Energy �ode Inspection Checklist
Property ❑rganixatian
7128 CHERRY CREEK 6LVD TSI Energy Solutions
CARMEL, IN 46033 ❑evin Sielschott
Madel: STDCKBRIaGE
Cammunity: THE GROVEAT LEGA[ 6uilder
PYATT 6lJILQERS, LLC
THE GROVE AT LEGACY 198A
GL198A �A5 ❑E51GNE�}
Duct Leakage Cvde Requirements fvr IECC
zao� iEcc:
Ins e�tion 5tatus _ T���nergyS�lutir�ns
p
Results are projected
P�stconstruction Leakage Test: Duct Leakage to Dutdoors �= 8 CFM25 ! 100 sq ft CFR.
Rough in Test with AHU: Total auct Leakage �= 6 CFM251 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage �= 4 CFM25 1 100 sq ft CFA.
2012 IECC Mandatory, 2D15 and 2018 IECC Prescriptive Paths:
Postconstructian Leakage Test: Tatal au�t Leaka�e �= 4 CFM251 100 sq ft CFA.
Rough in Test with AHU: Total auct Leakage �= 4 CFM251 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage �= 3 CFM25 1 10fl sq ft CFA.
2015 and 2018 IECC Performance Paths �Cost Compliancey:
Leakage testing is required UNLESS all ducts and air handlers are located entirely within tha thermal envelope.
There is no passlfail threshold for duct leakage on the performance path.
Praject Nates
4°Io DUCT LEAKAGE
4.5 ACH
PDSSIBLY MDREALLDUVA6LE DEPENDING ❑N R�TATIDN �F HDME
4
Building 5ummary
Property
7128 CHERRY CREEK 6LVD
CARI,�EL. IN 45033
hlodel: STDCK6RIDGE
Communitv: THE GRDVE AT LEGACY 198A
THE GROVE A7 LEGRCY 198A
GL198A{AS DESIGNED]
General Building Informatian
Number Of Bedroar�s
Number Of Floors
Conditioned FlaorArea [sq. ft.]
Has Ele�tric VehiGe Ready 5pa�e
Unconditioned; attached garage7
Canditioned Valume [�u. ft.]
Total Units in Building
Residence Type
Flaar Number
Madel
Cammunity
Climate Zone
argan ixation
TSI Energy Solutians
�evin Sielschatt
Builder
PYATT BL11L6ER5, LLC
3
2
2;2fi7
ND
Yes
23; 698
1
❑uplex; single unit
STDCKBRIDGE
THE GROVEAT LEGACY 198A
5A
Foundatian Wall
None Present
Faundativn Wall Liprary List
None Present
Slab
Name Library Type
SLA6 R-10. 1'dotvn. 2' in
Perimeter Floor Grade
156 OnGrade
Inspectian Status � �nergy S�lutir�ns
Results are proje�ted
Carpet R Exposed SurtaceArea Location
Masonry Area
1.23 0 1.685.D ft� Exposed Exterior
Enclosing
Conditioned
Spa�e
Slab Lihrary List
Name Wall Construction SIaG CQmpletely� LJnderslah Perimeter Perimeter Thermal Break Effective R-value
T�pe Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value
R-10, 1'down. 2' in �,Nood Frame ? Dther fVo 2 1 1 D Yes 16.00
Framed Flvar
None Present
�
Building 5ummary
Property
7128 CHERRY CREEK 6LVD
CARI,�EL. IN 45033
hlodel: STDCK6RIDGE
Communitv: THE GRDVE AT LEGACY 198A
THE GROVE A7 LEGRCY 198A
GL198A{AS DESIGNED]
Framed Floar Library List
Rim Jaist
Rim Jaist Library List
����
Name
CaND.�Ah16
C� M D'ATTI C
CaND.+CaND
CaN D.'GAR
I Wall Library List
Name
Gi R-15 BATT. dS6
G1 R-15 GarVdalls
G1 R-22 �bl l'�+all
argan ixation
TSI Energy Solutians
�evin Sielschatt
Builder
PYATT BL11L6ER5, LLC
None Present
None Present
None Present
Liqrary Type
G1 R-15 6ATT. �SB
G1 R-15 6ATT. �SB
G1 R-22 Dbl 4"Jall
G1 R-15Gar4^Jalls
�
EYfective R-value
13.423
11. 972
18.407
Inspectian Status
Results are proje�ted
Surtace Colar
f�ledium
f�ledium
F�ledium
f�ledium
5 urtace Area
2.501.a f[�
212.D f[�
16�.D f[�
63�.D f[�
+ TS��nergyS�lutir�ns
Location
Exposed Ex[erior
Atti�
Conditioned Space {Adiabatic}
Unconditioned. atta�hed garage
�
Building 5ummary
Property
7128 CHERRY CREEK 6LVD
CARI,�EL. IN 45033
hlodel: STDCK6RIDGE
Communitv: THE GRDVE AT LEGACY 198A
THE GROVE A7 LEGRCY 198A
GL198A{AS DESIGNED]
argan ixation
TSI Energy Solutians
�evin Sielschatt
Builder
PYATT BL11L6ER5, LLC
Glazing
Name Lihrary Type Wall Foundation Is Operaqle
Assignment Wall
Assignment
6.��K U-.31. CDNa+AI,�B Yes
SHGC-.3�
FRCVT U-.31. CONQ+RI�1B Yes
SHGC-.3�
LEF7SI�E U-.31. CDND+AI�1B Yes
SHGC-.3�
RIGH7SI�E U-.31. CDNa+'RI,�B Yes
S H GC-.30
SLIDER U-.31. CDNa+'RI,�B Yes
SHGC-.30
SLIDER U-.31. CDNa+'RI,�B Yes
SHGC-.30
Glazing Library List
Name
lJ-.31. 5 H G C-.30
Skylight
5kylight Library List
None Present
❑paque Davr
Name Library Type WallAssignment Fauandation Wall
Assignment
FRDNT Fiberglass+'Steel GOND.+AIAB
Door
GARAGE Fiberglass+'Steel COND.+GAR
Door
Inspectian Status � �nergy S�lutir�ns
Results are proje�ted
Overhang Dverhang Ft To Overhang Ft To ❑rientation SurfaceArea
❑epth Tap Bottom
0 � D South 168.� ft�
� 0 0 North 60.� ft�
0 0 D East 109.0 ft�
❑ 0 a West 34. � ft�
❑ 0 D South 120.� ft�
❑ 0 0 East 48. � ft�
� �
Shgc U-factar
0.3 �.310
None Present
Emittance Solar SurtaceColor SurtaceArea Location
Aqsarptance
0.9 0.75 Pvfedium 20.D f[� Exposed Exterior
�.9 0.75 h9edium 18.D f[� Exposed Exterior
�
Building 5ummary
Property
7128 CHERRY CREEK 6LVD
CARI,�EL. IN 45033
hlodel: STDCK6RIDGE
Communitv: THE GRDVE AT LEGACY 198A
THE GROVE A7 LEGRCY 198A
GL198A{AS DESIGNED]
❑paque Daor Library List
Name
Fiberglass.+Steel Door
argan ixation
TSI Energy Solutians
�evin Sielschatt
Builder
PYATT BL11L6ER5, LLC
Effective L!-factar
0.182
Inspectian Status � �nergy S�lutir�ns
Results are proje�ted
Ravf Insulation *
Name Library iype Attic ExteriorArea [ft'] Clay or Concrete Roof 5urtace Color 5urtaceArea Location
Tiles
h9AIN R-38 Blo�tin, GRi 1,G85 No hledium 1,685.0 f[� Atti�
R�vf Insulatian Library List
Name Has Radiant Barrier
R-38 Blown. GRi Na
Whale House Infiltratian
Infiltration Measurement Type
4.5ACH at 50 Pa Blower�oor tested
Mechanical Ventilation
Ventilation Type Ventilatifln Rate [ft' I Dperational haurs per day
M i n ute]
Exhaust �nly 53 CFI,� [unmeasured} 24
Effective R-value
38.268
Shelter Class
4
Fan Watts Runs once every three Energy Recovery Percenl
haurs
14 U"Jatts Yes 0
Lighting
% Interior Fluorescent =5 Interior LED Lighting :� Exterior Fluorescent l Exterior LEO Lighting `.: Garage Fluorescent I Garage LED Lighting
Lighting �ighting Lighting
90 Q 9D � 90 0
4
Building 5ummary
Property
7128 CHERRY CREEK 6LVD
CARI,�EL. IN 45033
hlodel: STDCK6RIDGE
Communitv: THE GRDVE AT LEGACY 198A
THE GROVE A7 LEGRCY 198A
GL198A{AS DESIGNED]
argan ixation
TSI Energy Solutians
�evin Sielschatt
Builder
PYATT BL11L6ER5, LLC
Inspectian Status � �nergy S�lutir�ns
Results are proje�ted
❑nsite Generation
None Present
❑nsite Generation Library List
None Present
Solar Generativn
None Present
Solar Generativn Library List
None Present
C�nditioning Equipment
Name Lihrary Type
Ai r con d iti o ner
Fuel-fred air
distrihution
1Nater Heating
CA13NA�36
9125A48�S6S17
ENT 50 1 D�
Equipment Type: 912SA48a6�S1�
Fuel Ty;�e Natural Gas
Disiri�utian Type Farced Air
�u�atorType PSG {Single Speed}
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtu.�h] 56
Use default EAE No
EAE [kWh] �49
Heating Percent Laad Cooling Percent Load Hot Water Percent Load
0 °.�
100°n
0°n
1 DO I
0%
0%
D°o
D°o
1�D°o
Location
Conditioned Space
Conditioned Space
Conditioned Space
�
Building 5ummary
Property
7128 CHERRY CREEK 6LVD
CARI,�EL. IN 45033
hlodel: STDCK6RIDGE
Communitv: THE GRDVE AT LEGACY 198A
THE GROVE A7 LEGRCY 198A
GL198A{AS DESIGNED]
Equipment Type: CA13NAa3G
Fuel T;rae
Distributian Type
Mator Type
Caaling Efficien�y
Cooling Capa�ity [kBtu.�h]
�quipment Type: ENT 5a 10a
�Fuel T,;,e
Distributian Type
Hot Water E�cien�y
Tank Capacity {gal.}
Hot Water Capa�ity [kBtu,'h]
Recavery Efficiency
argan ixation
TSI Energy Solutians
�evin Sielschatt
Builder
PYATT BL11L6ER5, LLC
Electri�
FQrced Air
PSG {Singfe Speed}
13 SEER
34 2
Inspectian Status � �nergy S�lutir�ns
Results are proje�ted
Electri�
Hydranic Delivery {Radiant]
0.93 Energy Factar
5�
15.4
0.98
Building 5ummary
Property
7128 CHERRY CREEK 6LVD
CARI,�EL. IN 45033
hlodel: STDCK6RIDGE
Communitv: THE GRDVE AT LEGACY 198A
THE GROVE A7 LEGRCY 198A
GL198A{AS DESIGNED]
Distributian 5ystem
Disiri�utian Type
Heating Equipment
Caaling Equipment
Sq. Feet Served
# Return Grilles
Supply Duct R Value
Return Duct R Value
Supply DuctArea [ftz]
Return Duct Area [ftZ]
Leakage ta Dutdaars
TotalLeakage
Total Leakage Duct Test Conditions
Use Default Flaw Rate
Duct 1
Duct La�ation
Percent 5upply Rrea
Percent ReturnArea
Duct 2
Duct La�ation
Percent 5upply Rrea
Percent ReturnArea
Duct 3
Duct La�ation
Percent 5upply Rrea
Percent ReturnArea
Duct 4
Duct Lacation
Percent 5upply Rrea
Percent ReturnArea
Duct 5
Duct La�ation
Percent 5upply Rrea
Percent ReturnArea
Duct 6
Duct La�ation
Percent 5upply Rrea
Percent ReturnArea
Geiling Fan
Has Ceiling Fan
Cfm Per Wari
argan ixation
TSI Energy Solutians
�evin Sielschatt
Builder
PYATT BL11L6ER5, LLC
Farced Air
Fuel-fired air distributian
Air canditioner
2267
2
25
25
�12.49
226.7
4 CFIv125 � 10� ftZ
181.3�i CFIv125
Post-Canstruction
Yes
Attic {well vented; under insulation}
75
5�
Conditianed 5pace
25
5[3
Conditio�ed 5pace
0
❑
Conditianed 5pace
0
4
Conditianed 5pace
0
d
Conditianed 5pace
0
0
Inspectian Status � �nergy S�lutir�ns
Results are proje�ted
No
1aa
Building 5ummary
Property
7128 CHERRY CREEK 6LVD
CARI,�EL. IN 45033
hlodel: STDCK6RIDGE
Communitv: THE GRDVE AT LEGACY 198A
THE GROVE A7 LEGRCY 198A
GL198A{AS DESIGNED]
argan ixation
TSI Energy Solutians
�evin Sielschatt
Builder
PYATT BL11L6ER5, LLC
Inspectian Status
Results are proje�ted
Water Distrihution
Water Fixture Type 5tandard
Use Default Hot Water Pipe Length �o
Hot Water Pipe Length [ft] 25
At Least R3 Pipe Insulatian? No
Hot Water Recirculation System7 No
Recirculation System Pipe Loop Length [ft] 10
Drain Water Heat Re�overy7 N❑
Clvthes Dryer
Cef
Fuel Type
Field Utilization
�s Outside Conditianed 5pace
Clothes DryerAvailable
Defaults Type
2.61?3913
Electric
Timer Contrals
No
Yes
HERS Reference
Clvthes Washer
Label Energy Rating
Annual Gas Gcst
Electric Rate
Gas Rate
Capacity
Imef
Defaults Type
Is Outside Conditianed 5pace
Clothes WasherAvailable
?��4 kWhr'Year
so oB�kWh
Sa.58rTherm
2.874
0.33052632
HERS Reference
ND
Yes
�ishwasher
Dish�,�asher Effi�iency 27� kWh
Dishwasher �ize 5tandard
Is Outside Conditianed 5pace N❑
Appliances and Cantrals
Proaramr�a�le thermastat?
Range'Duen Fuel
Canvectian Dven7
�nductian Range7
Range'Ouen Outside Conditioned Space?
Refrigeratar Gonsumption
Refrigeratar Outside Conditianed 5pace7
Yes
Natural Gas
No
ND
No
7�9 kWhr`Year
No
+ TS��nergyS�lutir�ns
::j
Building 5ummary
Property
7128 CHERRY CREEK 6LVD
CARI,�EL. IN 45033
hlodel: STDCK6RIDGE
Communitv: THE GRDVE AT LEGACY 198A
argan ixation
TSI Energy Solutians
�evin Sielschatt
Builder
PYATT BL11L6ER5, LLC
THE GROVE A7 LEGRCY 198A
GL198A{AS DESIGNED]
Nates
4`.'a DUCT LtAK,�1GE
�.5 ACH
Inspectian Status � �nergy S�lutir�ns
Results are proje�ted
POSSIBLY Iv10RE ALLOWABLE �EPEN�ING QN RQTATION OF HOME