Loading...
HomeMy WebLinkAboutA101.0N9062MU3260PT 3627PT 3060PTW01W01 W01W01 W02W02 A A501 A A501 B A501 B A501 A A502 A A502 A A503 A A503 +/- 20'-9 1/4" O/S EXIST. STONE VENEER TO O/S NEW STUD +/- 11'-11" O/S EXIST. STONE VENEER TO O/S STUD19'-9 3/4" CL OF EXIST. COLUMN TO CL. OF EXIST. COLUMN 3'-3 1/4" 13'-3 1/4" 3'-3 1/4" 1'-7 3/4" 8'-3 1/8" 8'-3 1/8" 1'-7 3/4"10'-8 5/16" CL EXIST. COLUMN TO CL EXIST. COLUMN1'-11 1/2"3'-4 11/16" 3'-4 11/16" 1'-11 7/16" CONVERTED PORCH OUTSIDE FACE OF NEW WALL TO LINE UP WITH OUTSIDE OF EXISTING STONE VENEER (APPROX. 2" FROM EDGE OF CONCRETE SLAB) OUTSIDE FACE OF NEW WALL TO BE APPROX. 2" FROM EDGE OF CONCRETE SLAB EXISTING STRUCTURAL COLUMN WITH NEW 1X POPLAR TRIM (REFER TO DETAILS) EXISTING HOUSE EXISTING PAVER PATIO EXISTING STRUCTURAL COLUMN WITH NEW 1X POPLAR TRIM (REFER TO DETAILS) EXISTING STRUCTURAL COLUMN WITH NEW 1X POPLAR TRIM (REFER TO DETAILS) D01D01 PROPOSED CONSTRUCTION NOTES: - FURNISH & INSTALL (2) NEW 4X4 POSTS ON EXISITNG CONCRETE SLAB AS SHOWN - FURNISH & INSTALL (2) NEW EXTERIOR WALLS WITH TREATED 2X4 BOTTOM PLATE, 2X4 WALL STUDS @ 16" O/C, AND DOUBLE 2X4 TOP PLATES ON EXISITING CONCRETE SLAB. - FURNISH & INSTALL 7/16" OSB EXTERIOR WALL SHEATHING, TYVEK (OR EQUIV.) HOUSEWRAP, & SHINGLE PANEL SYSTEM ON OUTSIDE FACE OF NEW WALLS. FURNISH & INSTALL 1X ENGINEERED TRIM AS SHOWN. - FURNISH & INSTALL (1) SLIDING DOOR (REFER TO DOOR SCHEDULE FOR DETAILS) - FURNISH & INSTALL (5) DOUBLE-HUNG WINDOWS (REFER TO WINDOW SCHEDULE FOR DETAILS) - FURNISH & INSTALL R-15 KRAFT-FACED BATT INSULATION IN NEW EXTERIOR WALL CAVITIES. - FURNISH & INSTALL 9" DEPTH BLOWN-IN CELLULOSE INSULATION ABOVE EXISTING CEILING IN EXISTING ATTIC SPACE. - FURNISH & INSTALL NEW 1/2" FINISHED DRYWALL ON INTERIOR FACE OF NEW WALLS. - FURNISH & INSTALL NEW 1X POLAR TRIMS AS SHOWN ON ELEVATIONS & DETAILS. - INSTALL (1) HOMEOWNER-PROVIDED DOG DOOR - FURNISH & INSTALL NEW BEADBOARD CEILING TO MATCH EXISTING AS NECESSARY - REINSTALL SALVAGED 1X CEILING TRIM AS NECESSARY **ALL HVAC WORK TO BE PROVIDED BY HOMEOWNER** **ALL PREP, PRIMING, & PAINTING TO BE PROVIDED BY HOMEOWNER** **ANY MODIFICATIONS TO EXISTING FENCE TO BE PROVIDED BY HOMEOWNER** PERMIT #1 ISSUE DATE: 2020-08-27 REV: www.caseindy.com 99 E. Carmel Drive, Suite 100 Carmel, Indiana 46032 317.846.2600 317.846.2601(f) These drawings have been prepared by Case Design & Remodeling solely for its use and should not be reproduced or relied upon by any other parties. Dimensions shown or scaled are subject to change per actual job condition and must be verified. Materials are to be supplied as specified as equal or standard when not uniquely specified. Installed materials may vary in appearance from drawings. Reference manufacturer's product data for actual appearance and specifications.RAINES PROJECTPORCH CONVERSIONC.W. & JILL RAINES5331 RANDOLPH CRESCENT DRIVECARMEL, INDIANA 46033Approved By: Date: A101 Craig Dice Architectural Designer cdice@caseindy.com Dawn Ashburn Project Developer dashburn@caseindy.com 252590026 JOB NUMBER: PROPOSED FLOOR PLANA A101 A A101 SCALE: 3/8" = 1'-0" #2 2020-09-24 10/13/20