HomeMy WebLinkAboutLS200 - P.2 Life Safety PlanREFRIG BYTENANTR EF RIGB YTEN AN TR EF RIGB YTEN AN T REFRIGBYTENANT R E FR I GBYTENANT REFRIGBYTENANT x MEET 204 16'-2"21'-0" TV 15' L GRAB N GO VENDING FINAL LAYOU T BY VENDOR ELEVATOR LOBBY 202TV SOCIAL HUB 203 MEZZ 201MICROFE ELNELNELNELN x MEET 204 16'-2"21'-0" TV 15' L GR A B N GO V E N D I NG FINA L LAY O U T BY VEN D O R ELEVATOR LOBBY 202TV SOCIAL HUB 203 MEZZ 201MICROFE ELNELNELNELN LIFE SAFETY PLAN L100OVERALL BUILDING PLAN DESCRIPTIONDATE ISSUE 07.24.20 REVIEW SET 07.28.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 08.18.20 EH UPDATED SET THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TENANT LOUNGE +ELEVATOR LOBBYCITY CENTER AT PENN | 2ND FLOOR1320 CITY CEN TER DRIVE, CARMEL, IN 46032 JREH 2020.078 2ND FLOOR N 1 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. LIFE SAFETY NOTES L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. PROVIDE NEW OR RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. L3. RELOCATE EXISTING SPRINKLER HEADS TO FIT NEW WALL LAYOUT; PROVIDE NEW AS REQUIRED, SPRINKLERS TO BE LOCATED PER FIRE PROTECTION CODE. L4. PROVIDE NEW LED EDGE LIT EXIT SIGNS, WALL MOUNTED EMERGENCY BATTERY PACKS OR INTEGRATED EMERGENCY LIGHT FIXTURES AND LIFE SAFETY STROBES/HORNS TO MATCH BUILDING STANDARD AS REQUIRED BY BUILDING CODE. GENERAL NOTES EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT - BUILDING STAIR LOCATION EP EX LEGEND FIRE EXTINGUISHER EXIT SIGN FE EMERGENCY LIGHT FE AREA NOT IN CONTRACT AREA OF WORK TRAVEL DISTANCE SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE TOTAL BUILDING AREA TOTAL PROJECT AREA CHANGE OF OCCUPANCY CLASS? OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD NO OCCUPANCY CLASSIFICATION B(USINESS) SOCIAL HUB/MEET SF ELEV LOBBY/MEZZ 15 100 726 SF NUMBER OF EXITS REQUIRED: 2 PROVIDED: 3 SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 TOTAL AREA ON THE FLOOR SF SF/FLOOR X STORIES SF SF 45,576 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A = TOTAL OCCUPANTS IN PROJECT AREA 86 8 CODE SUMMARY PREVIOUS USE OF SPACE B(USINESS) ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN) BUILT BEFORE 1978? NO 1,172 1,898 45,576 3 136,728 78 - LED EDGE LIT BUILDING CONSTRUCTION TYPE II-B BUSINESS TRA V E L D I STA N C E = 8 0 ' 0 8' 16'4' ENLARGED LIFE SAFTEY PLAN L100 1 NOT TO SCALE EX BUSINESS BUSINESS BUSINESS BUSINESS EX EX EX L100 1 BUSINESS REMAINING SPACE OF 14,227 SF AREA TO BE ALTERED TO MEET CODE IN SEPARATE PROJECT SCOPE TRAVEL DISTANCE = 129' INTENT IS FOR "FLOATING" EMERGENCY LIGHTS TO BE INSTALLED ON VERTICAL FACE OF BULKHEAD; REFER TO CEILING PLAN. 10/14/20