LIFE SAFETY
PLAN
L100OVERALL BUILDING PLAN
DESCRIPTIONDATE
ISSUE
07.24.20 REVIEW SET
07.28.20 PERMIT SET
REVISIONS
DESCRIPTIONMARK DATE DB
08.18.20 EH UPDATED SET
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR TENANT LOUNGE +ELEVATOR LOBBYCITY CENTER AT PENN | 2ND FLOOR1320 CITY CEN TER DRIVE, CARMEL, IN 46032
JREH
2020.078
2ND FLOOR
N
1
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
LIFE SAFETY NOTES
L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN. PROVIDE NEW OR RELOCATE
EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM
NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES.
L3. RELOCATE EXISTING SPRINKLER HEADS TO FIT NEW WALL LAYOUT;
PROVIDE NEW AS REQUIRED, SPRINKLERS TO BE LOCATED PER FIRE
PROTECTION CODE.
L4. PROVIDE NEW LED EDGE LIT EXIT SIGNS, WALL MOUNTED EMERGENCY
BATTERY PACKS OR INTEGRATED EMERGENCY LIGHT FIXTURES AND LIFE
SAFETY STROBES/HORNS TO MATCH BUILDING STANDARD AS
REQUIRED BY BUILDING CODE.
GENERAL NOTES
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT - BUILDING STAIR LOCATION
EP
EX
LEGEND
FIRE EXTINGUISHER
EXIT SIGN
FE
EMERGENCY LIGHT
FE
AREA NOT IN CONTRACT
AREA OF WORK
TRAVEL DISTANCE
SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE
TOTAL BUILDING AREA
TOTAL PROJECT AREA
CHANGE OF OCCUPANCY CLASS?
OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
NO
OCCUPANCY CLASSIFICATION B(USINESS)
SOCIAL HUB/MEET SF
ELEV LOBBY/MEZZ
15
100 726 SF
NUMBER OF EXITS REQUIRED: 2 PROVIDED: 3
SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES 0
TOTAL AREA ON THE FLOOR
SF
SF/FLOOR X STORIES SF
SF
45,576 SF
ACCESSORY AREA EXCEEDS 10% NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
=
TOTAL OCCUPANTS IN PROJECT AREA 86
8
CODE SUMMARY
PREVIOUS USE OF SPACE B(USINESS)
ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN)
BUILT BEFORE 1978? NO
1,172
1,898
45,576 3 136,728
78
- LED EDGE LIT
BUILDING CONSTRUCTION TYPE II-B
BUSINESS
TRA
V
E
L
D
I
STA
N
C
E
= 8
0
'
0 8' 16'4'
ENLARGED LIFE SAFTEY PLAN
L100
1
NOT TO SCALE
EX
BUSINESS
BUSINESS
BUSINESS
BUSINESS
EX
EX
EX
L100
1
BUSINESS
REMAINING SPACE OF 14,227 SF
AREA TO BE ALTERED TO MEET CODE IN SEPARATE
PROJECT SCOPE
TRAVEL DISTANCE = 129'
INTENT IS FOR "FLOATING" EMERGENCY LIGHTS TO BE INSTALLED
ON VERTICAL FACE OF BULKHEAD; REFER TO CEILING PLAN.
10/14/20