Loading...
HomeMy WebLinkAboutS200 - P.4 Structural PlanMEET 204 ELEVATOR LOBBY 202 SOCIAL HUB 203 MEZZ 20121'-5"FE6'-11 4"5'-0" 14'-0"1'-0" 6'-0" 1'-0"8'-1012"2'-4" ARCHITECTURAL FLOOR PLAN A111 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. NEW SEMI-RECESSED FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. SEMI-RECESSED CABINET TO BE PAINTED TO MATCH ADJACENT WALL COLOR. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH BUILDING OWNERSHIP + PROPERTY MANAGEMENT. CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W1". IF NOT, ALTER EXISTING WALL AS REQUIRED TO MATCH "W1". PROVIDE ALLOWANCE FOR WHITE NOISE SYSTEM AT THIS LOCATION. FINAL LAYOUT AND PLACEMENT TO BE COORDINATED WITH BUILDING MANAGEMENT AND OWNERSHIP. RELOCATE EXISTING HERCULITE DOUBLE DOOR ASSEMBLY FROM DECONSTRUCTION TO THIS LOCATION. PROVIDE DRYWALL OPENING PER DIMENSIONS OF DOOR ASSEMBLY. PROVIDE 4'-0" X 8'-0" MAGNETIC GLASS WHITEBOARD WITH APPROPRIATE BLOCKING IN WALL AT THIS LOCATION. WHITEBOARD TO INCLUDE MAGNETIC MARKER + ERASER ACCESSORY CADDY PROVIDE FULLY UPHOLSTERED BUILT-IN BENCH AT THIS LOCATION. REFER TO ELEVATIONS + DETAILS FOR MORE INFORMATION. ON TENANT LOUNGE SIDE OF PARTIAL HEIGHT WALL, PROVIDE 3FORM EDGE MODULAR PARTITION FEATURE WITH SOLA FELT + UNIFORM PROFILE. PANELS ARE 42"W X 96"H; COLOR TBD. INTENT IS FOR WALL PANELS TO FORM 90 DEGREE ANGLE WITH 3FORM CEILING PANEL. REFER TO CEILING NOTES. PROVIDE PERIMETER-FRAMED STOREFRONT GLASS SYSTEM WITH TWO FRAMELESS CORNERS AS SHOWN; REFER TO DOOR SCHEDULE FOR MORE INFORMATION. _______________________________________________________________________________________________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO PROPERTY MANAGEMENT FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES AS REQUIRED. CONFIRM ANY REQUIRED WATER LINES WITH BUILDING OWNERSHIP'S FOOD+DRINK VENDOR. PLAN NOTES ARCHITECTURAL PLAN AREA NOT IN CONTRACT AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL WINDOW / SIDELIGHTWINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL W1 WALL WITH INSULATION 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING PARTIAL HEIGHT WALL 35 8 " METAL STUDS AT 16" O.C.; ONE LAYER OF 5 8" TYPE "X" GYPSUM BOARD EACH SIDE; SEE ELEVATION FOR WALL HEIGHT; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; PROVIDE DRYWALL TOP CAP. W2 WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DESCRIPTIONDATE ISSUE 07.24.20 REVIEW SET 07.28.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 08.18.20 EH UPDATED SET THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TENANT LOUNGE +ELEVATOR LOBBYCITY CENTER AT PENN | 2ND FLOOR1320 CITY CENTER DRIVE, CARMEL, IN 46032JREH 2020.078 2ND FLOOR N 1 0 2' 4' 8' 16' 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. IN AREA WITH EXPOSED CEILING DECK, ENSURE THAT DRYWALL ON ALL NEW AND EXISTING WALLS EXTENDS TO DECK; PROVIDE NEW DRYWALL AS REQUIRED. TRANSITION TO BE A CLEAN HORIZONTAL LINE FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. SEE REFLECTED CEILING PLAN FOR EXACT AREA OF EXPOSED CEILING. GENERAL NOTES W2 EXTEND WALL TO 4'-6"; W? A211 2 A211 3 DOOR AND FRAME 10/14/20