Loading...
HomeMy WebLinkAboutE200 - P.8 Electrical PlanMEET 204 TV 15' L GR A B N G O V E N D I NG FINAL L AY O U T BY VEN D O R ELEVATOR LOBBY 202TV SOCIAL HUB 203 MEZZ 201MICRO+60"+60"+60" +60" +60" +42" DED GFCI ELECTRICAL PLAN E111 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 60" A.F.F. PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. PROVIDE POWER AND DATA FOR GRAB-N-GO VENDING AT THIS LOCATION. FINAL REQUIREMENTS TBD. PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND DATA. COORDINATE WITH TENANT'S FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO SDI AND BUILDING OWNERSHIP FOR APPROVAL PRIOR TO ORDERING. PROVIDE DIRECT HDMI/VGA CONDUIT CONNECTION FROM FLOOR CORE POKE THRU DEVICE TO WALL MOUNTED MONITOR. PLAN NOTES ELECTRICAL PLAN LEGEND DESCRIPTIONDATE ISSUE 07.24.20 REVIEW SET 07.28.20 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB 08.18.20 EH UPDATED SET THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR TENANT LOUNGE +ELEVATOR LOBBYCITY CENTER AT PENN | 2ND FLOOR1320 CITY CENTER DRIVE, CARMEL, IN 46032JREH 2020.078 2ND FLOOR N 1 0 2' 4' 8' 16' 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND AUTOMATIC SHUTOFF VALVES AS REQUIRED. 5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 6. ALL EXISTING POWER AND DATA TO REMAIN UNLESS NOTED OTHERWISE. ALL NEW AND EXISTING COVER PLATES AND DEVICES ARE TO BE WHITE; REPLACE EXISTING AS REQUIRED. 7. PROVIDE AMPLE WIFI COVERAGE IN AREA OF WORK, INCLUDING MEZZ AREA AND FIRST FLOOR LOBBY. COORDINATE WITH BUILDING MANAGEMENT FOR EXACT REQUIREMENTS. GENERAL NOTES DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, DUPLEX BOX, BLANK COVER PLATE BOX, OPEN BOX, BLANK COVER PLATE BOX, OPEN FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE B O +42" AREA NOT IN CONTRACT AREA OF WORK 10/14/20