HomeMy WebLinkAboutA008 - General Notes and InformationA. CONTRACTOR IS RESPONSIBLE TO CONFORM WITH APPLICABLE FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS INCLUDING APPLICABLE ORDINANCES AND REFERENCED STANDARDS. B. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO SUBMITTING A BID OR BEGINNING ANY WORK. CONDITIONS FOUND TO BE IN VARIANCE FROM THE INFORMATION IN THE DRAWINGS OR PROJECT MANUAL SHALL BE SUBMITTED TO THE ARCHITECT IN WRITING FOR CLARIFICATION. C. KEYNOTES ARE MEANT AS A GENERAL GUIDE FOR TYPICAL LOCATIONS. CONTRACTOR TO PERFORM FULL EXTENT OF WORK REQUIRED TO ACCOMPLISH DESIGN INTENT. THE ABSENCE OF A KEYNOTE DOES NOT ABSOLVE THE CONTRACTOR FROM PROVIDING THE FEATURE GRAPHICALLY INDICATED ON THE DRAWINGS. D. SPECIFIC WORK ITEMS SHALL BE COORDINATED AND INTERFACED WITH ALL OTHER TRADES TO ALLOW FOR NEW CONSTRUCTION AND COMPLETE INSTALLATION AS REQUIRED TO ACCOMPLISH DESIGN INTENT. E. REFER TO DRAWINGS OF EACH TRADE OR DISCIPLINE FOR ADDITIONAL GENERAL NOTES AND INFORMATION, INCLUDING CIVIL/SITE DEVELOPMENT, ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL. F. CONTRACTOR IS RESPONSIBLE FOR ALL WORK IDENTIFIED ON ALL DRAWINGS AND INFORMATION IN THE PROJECT MANUAL, AS A COMPLETE PROJECT. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE SPECIFIC SCOPE OF WORK FOR ANY SUBCONTRACTORS FOR THIS PROJECT. G. FIELD VERIFY ACTUAL LOCATIONS OF EXISTING UNDERGROUND UTILITIES, STRUCTURES, WATER LINES, STORM AND SANITARY LINES, GAS LINES, ELECTRICAL CONDUIT, AND OTHER UNDERGROUND UTILITIES PRIOR TO PERFORMING EARTHWORK, EXCAVATION, OR UTILITY WORK. ENGAGE THE SERVICES OF A PRIVATE UTILITY LOCATE COMPANY IF NECESSARY TO COMPLETELY LOCATE EXISTING UNDERGROUND UTILITIES AND STRUCTURES. H. LOCATION OF ALL TEMPORARY FACILITIES SHALL BE COORDINATED WITH OWNER AND ARCHITECT PRIOR TO MOBILIZATION ON-SITE, INCLUDING BUT NOT LIMITED TO TEMPORARY STAGING AREA, MATERIAL STORAGE AREA, ACCESS DRIVE(S), PARKING AREA, TOPSOIL STOCKPILE AREA, WASTE DISPOSAL AREA, FIELD OFFICES AND TEMPORARY FACILITIES, JOB SIGN, AND TEMPORARY FENCING. I. CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL MISCELLANEOUS BLOCKING REQUIRED FOR INSTALLATION OF ALL BUILDING COMPONENTS, INCLUDING BUT NOT LIMITED TO FURNISHINGS, FIXTURES, EQUIPMENT, HARDWARE, BRACKETS, AND OWNER- PROVIDED EQUIPMENT. CONTRACTOR SHALL COORDINATE SPECIFIC REQUIREMENTS ASSOCIATED WITH EACH TRADE AND WITH OWNER'S REPRESENTATIVE. J. CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL MISCELLANEOUS WOOD AND METAL TRIM, FLASHING, CLIP ANGLES, ANCHORS, SUPPORTS, AND CLOSURE TRIM REQUIRED TO PROVIDE A COMPLETE, UNIFORM, AND WEATHERTIGHT ASSEMBLY AS REQUIRED TO ACCOMPLISH THE DESIGN INTENT. K. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE AND INSTALL ALL ACCESSORY COMPONENTS AS REQUIRED TO FULLY COMPLY WITH MANUFACTURER'S RECOMMENDATIONS. L. CONTRACTOR SHALL PROVIDE ACCESS DOORS IN ALL WALLS AND CEILINGS WHERE SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING, FIRE PROTECTION OR ELECTRICAL ITEMS MAY BE REQUIRED. ACCESS DOORS SHALL BE OF AN APPROPRIATE SIZE REQUIRED FOR EACH APPLICATION. WHERE APPLICABLE, ACCESS DOORS SHALL MATCH THE FIRE RATING OF THE WALL ASSEMBLY. M. WHERE DISCREPANCIES EXIST IN THE CONTRACT DOCUMENTS INCLUDING DISCREPANCIES BETWEEN DRAWINGS AND PROJECT MANUAL OR DRAWINGS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS, CONTRACTOR SHALL REQUEST CLARIFICATION IN WRITING FROM ARCHITECT. THE CONTRACTOR SHALL NOT ASSUME ANY ITEM TAKES PRECEDENCE OVER THE OTHER. ANY ACTION THE CONTRACTOR MAKES PRIOR TO NOTIFICATION IN WRITING SHALL BE SOLELY AT THE CONTRACTOR'S RISK. N. CONTRACTOR SHALL SEAL ALL PENETRATIONS IN EXTERIOR WALL AND ROOF ASSEMBLIES WITH APPROPRIATE JOINT SEALANT(S) AND FLASHING(S) TO MAINTAIN A WEATHERTIGHT AND AIRTIGHT BUILDING ENVELOPE. ALL JOINTS AND PENETRATIONS SHALL BE SEALED, GASKETED, OR WEATHER-STRIPPED TO MINIMIZE AIR LEAKAGE, INCLUDING THE FOLLOWING: a. JOINTS AROUND FENESTRATION AND DOOR FRAMES. b. JUNCTIONS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AT BUILDING CORNERS, BETWEEN WALLS AND FLOORS OR ROOFS, AND BETWEEN WALLS AND ROOF OR WALL PANELS. c. OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH ROOFS, WALLS, AND FLOORS. d. JOINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDERS. e. ALL OTHER OPENINGS IN THE BUILDING ENVELOPE. O. COORDINATE WITH OTHER CONSTRUCTION ACTIVITIES AND CONSTRUCTION SEQUENCING WITH OTHER PROJECT(S) AND WORK BEING PERFORMED CONCURRENTLY ON-SITE. P. BUILDING ELEVATION 100'-0" EQUALS SITE ELEVATION 826.58. Q. CONTRACTOR TO PROTECT ALL ITEMS WITHIN THE CONSTRUCTION LIMITS (INCLUDING SITE ELEMENTS) THAT ARE DESIGNATED TO REMAIN; ITEMS DAMAGED AS A RESULT OF WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED OR REPLACED TO ORIGINAL CONDITION. R. ALL PENETRATIONS AND JOINTS IN FIRE-RATED WALL ASSEMBLIES AND FLOOR/CEILING ASSEMBLIES SHALL BE SEALED WITH THE FIRESTOPPING SYSTEM OR FIRE-RESISTIVE JOINT SYSTEM WHICH IS THE MOST APPROPRIATE FOR THE SPECIFIC APPLICATION BASED ON THE TYPE OF ASSEMBLY AND TYPE OF PENETRATING ELEMENT. SYSTEMS SHALL BE U.L.-LISTED FOR EACH APPLICATION. S. ALL VERTICAL FENESTRATION (OPERABLE AND FIXED GLAZED ASSEMBLIES) SHALL BE LABELED BY THE MANUFACTURER WITH U-FACTOR, SHGC RATING, SAFETY RATING, AND FIRE-RESISTANCE RATING, WHERE APPLICABLE. WINDOWS AND DOORS SHALL BE CERTIFIED AS MEETING AIR LEAKAGE REQUIREMENTS PER NFRC 400. T. THESE DRAWINGS SHALL NOT BE SCALED TO OBTAIN DIMENSIONS. IF THE DIMENSIONS CANNOT BE DETERMINED BY THE INFORMATION GIVEN, CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE ARCHITECT. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CMU, OR FACE OF CONCRETE, UNLESS NOTED OTHERWISE. CEILING HEIGHT DIMENSIONS ARE FROM FINISHED FLOOR TO FACE OF FINISHED CEILING MATERIALS, UNLESS NOTED OTHERWISE. A5.1 KEYNOTE TARGET DRAWING TITLE SYMBOL # ROOM NAME ROOM NAME ROOM NUMBER DESCRIPTION X WALL TYPE TARGET BUILDING SECTION TARGET SECTION NUMBER SHEET NUMBER VERTICAL ELEVATION BUBBLE NORTH ARROW DOOR MARK TARGET X SHT DETAIL TARGET XXXXXXXX SHEET NUMBER DETAIL NUMBER X SHTSHEET NUMBER SECTION NUMBER WALL SECTION TARGET INTERIOR ELEVATION TARGET WINDOW TARGETX EXTERIOR ELEVATION TARGETELEVATION NUMBER SHEET NUMBER DRAWING SCALE # XXX SCALE: XXX DRAWING NAME DETAIL NUMBER 3 X SHT X SHT NORTH X SHEET NUMBER NUMBER ELEVATION X SHT SYMBOL DESCRIPTION SYMBOL DESCRIPTION PROJECT SITE 210 VETERANS WAY CARMEL, IN 46032 DLZ INDIANA, LLCDRAWING NUMBERPROJECT NUMBERDATE:APPRV'D:DESIGNED:DRAWN:CHK'D:9/25/2020 2:54:39 PMC:\RevitBackups\2020\1963-1025-90_AdminBldg_Arch_zakkaz11.rvtG1.1ACOMMUNITY BUILDINGCARMEL CLAY1963-1025-90ZJFHWSHWSSEPTEMBER 18, 2020ZJFGENERAL NOTES AND INFORMATION, SET AGENERALCARMELINDIANABID PACKAGE 2Symbols General Notes Location Map Sheet Index NUMBER SHEET NAME GENERAL G1.0A TITLE SHEET, SET A G1.1A GENERAL NOTES AND INFORMATION, SET A G1.2 CODE COMPLIANCE PLANS G1.3 CODE ANALYSIS G1.4 ABBREVIATIONS AND ADA MOUNTING HEIGHTS SITE DEVELOPMENT SD0.3 CITY OF CARMEL RIGHT OF WAY PAVING POLICY SD0.4 CITY OF CARMEL CONCRETE CURB POLICY SD3.7 STORM WATER POLLUTION PREVENTION PLAN SD4.1 PLANTING PLAN SD5.2 SITE DETAILS - 1 SD5.3 SITE DETAILS - 2 ARCHITECTURE A2.1 FIRST FLOOR PLAN A2.2 SECOND FLOOR PLAN A2.3 THIRD FLOOR PLAN A2.4 FOURTH FLOOR PLAN A2.5 ENLARGED FOURTH FLOOR GALLERY PLAN A3.1 ROOM FINISH AND PARTITION SCHEDULES A3.2 DOOR AND FRAME SCHEDULE & ELEVATIONS A3.3 DOOR DETAILS - 1 A3.4 DOOR DETAILS - 2 A3.5 WINDOW ELEVATIONS A3.6 EXTERIOR WINDOW 3D VIEWS A3.7 WINDOW DETAILS - 1 A3.8 WINDOW DETAILS - 2 A3.9 WINDOW DETAILS - 3 A3.10 WINDOW DETAILS - ALTERNATE A4.1 ROOF PLAN A4.2 ROOF DETAILS - 1 A4.3 ROOF DETAILS - 2 A4.4 ROOF DETAILS - 3 A4.5 ROOF DETAILS - 4 A5.1 EAST AND WEST EXTERIOR ELEVATIONS A5.2 NORTH AND SOUTH EXTERIOR ELEVATIONS A5.3 EXTERIOR ELEVATIONS A5.4 ALTERNATE EXTERIOR ELEVATIONS A6.1 E-W BUILDING SECTIONS - 1 A6.2 E-W BUILDING SECTIONS - 2 A6.3 E-W BUILDING SECTIONS - 3 A6.4 N-S BUILDING SECTIONS - 1 A6.5 N-S BUILDING SECTIONS - 2 A6.6 N-S BUILDING SECTIONS - 3 A7.1 WALL SECTIONS - 1 A7.2 WALL SECTIONS - 2 A7.3 WALL SECTIONS - 3 A7.4 WALL SECTIONS - 4 A7.5 WALL SECTIONS - 5 A7.6 WALL SECTIONS - 6 A7.7 SECTION DETAILS AND FIRESTOPPING DETAILS A7.8 STONE, METAL, AND GFRC TRIM PROFILES A8.1 CASEWORK PLANS, ELEVATIONS, AND DETAILS - FIRST AND SECOND FLOOR A8.2 CASEWORK PLANS, ELEVATIONS, AND DETAILS - SECOND FLOOR A8.3 ENLARGED TOILET PLANS AND INTERIOR ELEVATIONS - FIRST FLOOR A8.4 ENLARGED TOILET PLANS AND INTERIOR ELEVATIONS - SECOND FLOOR A8.5 ENLARGED TOILET PLANS AND INTERIOR ELEVATIONS - SECOND, THIRD, AND FOURTH FLOORS A9.1 INTERIOR ELEVATIONS - FIRST FLOOR A9.2 INTERIOR ELEVATIONS - THIRD AND FOURTH FLOOR A10.1 FIRST FLOOR REFLECTED CEILING PLAN A10.1A FIRST FLOOR REFLECTED CEILING PLAN - ALTERNATE A10.2 SECOND FLOOR REFLECTED CEILING PLAN A10.2A SECOND FLOOR REFLECTED CEILING PLAN - ALTERNATE A10.3 THIRD FLOOR REFLECTED CEILING PLAN A10.4 FOURTH FLOOR REFLECTED CEILING PLAN A11.1 FLOOR PLAN DETAILS A11.2 FLOOR PLAN DETAILS - THIRD FLOOR AND FOURTH FLOOR GALLERY A12.1 STAIR ST11 ENLARGED PLANS, SECTIONS, AND DETAILS A12.2 STAIR ST21 ENLARGED PLANS, SECTION, AND DETAILS A12.3 ELEVATOR ENLARGED PLAN, ELEVATIONS, AND DETAILS A13.1 FIRST FLOOR FINISH PLAN A13.2 SECOND FLOOR FINISH PLAN A13.3 THIRD FLOOR FINISH PLAN A13.4 FOURTH FLOOR FINISH PLAN STRUCTURAL S0.1 GENERAL NOTES S0.2 GENERAL NOTES & ABBRIVIATIONS S1.0 FOUNDATION PLAN S1.1 SECOND FLOOR FRAMING PLAN S1.2 THIRD FLOOR FRAMING PLAN S1.3 FOURTH FLOOR FRAMING PLAN S1.4 ROOF FRAMING PLAN S2.0 ENLARGED FRAMING PLANS S3.0 TYPICAL FOUNDATION DETAILS & SECTIONS S4.0 TYPICAL MASONRY DETAILS & SECTIONS S4.1 TYPICAL MASONRY DETAILS & SECTIONS S5.0 TYPICAL FRAMING DETAILS & SECTIONS S5.1 TYPICAL FRAMING DETAILS & SECTIONS S5.2 FRAMING DETAILS & SECTIONS S5.3 FRAMING DETAILS & SECTIONS S5.4 FRAMING DETAILS & SECTIONS S5.5 FRAMING DETAILS & SECTIONS S5.6 FRAMING DETAILS & SECTIONS S5.7 FRAMING DETAILS & SECTIONS TELEPHONE AT&T -DISTRIBUTIO 240 N. MERIDIAN STREET, ROOM 1791 INDIANAPOLIS, IN 46204 PHONE: (317) 610-5422 BRAD BAILEY FIBEROPTIC CARMEL CLAY COMMUNICATIONS CENTER 31 1ST AVENUE NW CARMEL, IN 46032 PHONE: (317) 571-2590 TODD LUCKOSKI FIBEROPTIC CENTURYLINK 100 S. CINCINNATI AVENUE, SUITE 1200 TULSA, OK 74103 PHONE: (918) 547-0547 KENDALL WILLIAMS-ZETINA SANITARY SEWERS CITY OF CARMEL UTILITIES SANITARY SEWER SYSTEM 30 WEST MAIN STREET, SUITE 200 CARMEL, IN 46032 PHONE: (317) 571-2443 JOE FAUCETT GAS VECTREN 16000 ALLISONVILLE ROAD NOBLESVILLE, IN 46060 PHONE: (317) 776-5590 CHAD MILLER WATER CITY OF CARMEL UTILITIES 30 WEST MAIN STREET, SUITE 200 CARMEL, IN 46032 PHONE: (317) 571-2443 STEVE COOK ELECTRIC DUKE ENERGY PHONE: (317) 776-5305 CHRISTINA GIROD STORMWATER CITY ENGINEER CARMEL CITY HALL, FIRST FLOOR ONE CIVIC SQUARE CARMEL, IN 46032 PHONE: (317) 571-2441 JEREMY KASHMAN TRANSPORTATION / TRAFFIC LIGHTS CITY OF CARMEL STREET DEPARTMENT 31 1ST AVENUE NW CARMEL, IN 46032 PHONE: (317) 571-2590 TODD LUCKOSKI NO.REVISIONDATE1ADD. 0109/20SUBJECT REAL ESTATE DESCRPTION INSTRUMENT NUMBER 2016029856 TAX PARCEL NUMBER 16-09-25-16-05-004.000 FIREMAN'S MUSEUM BEGINNING 32 RODS 7 FEET 1 INCH SOUTH AND 24 RODS 1 FEET 6 INCHES WEST OF THE NORTHEAST COMER OF THE SOUTHEAST QUARTER OF SECTION 25 TOWNSHIP 18 NORTH RANGE 3 EAST IN HAMILTON COUNTY, INDIANA AND RUN SOUTH 218 FEET, THENCE WEST 165 FEET, THENCE NORTH 218 FEET, THENCE EAST 165 FEET TO THE PLACE OF BEGINNING. LEGAL DESCRIPTION ZONING DISTRICT: C2 SETBACK DISTANCES: N/A TOTAL SITE DISTURBANCE: 35,785 SQUARE FEET BUILDING COVERAGE TO SITE AREA RATIO: 1:1.97 (50.74%) REQUIRED PARKING SPACES: 0 FIBEROPTIC ZAYO BANDWIDTH 9209 CASTLEGATE DRIVE INDIANAPOLIS, IN 46256 PHONE: (765) 341-1199 WAYLON HIGGINS CABLE SPECTRUM 3030 ROOSEVELT AVENUE INDIANAPOLIS, IN 46218 PHONE: (317) 429-6691 JASON KIRKMAN CABLE COMCAST CABLE (INDIANAPOLIS) PHONE: (317) 752-6569 SCOTT EVANS NUMBER SHEET NAME GENERAL G1.0B TITLE SHEET, SET B G1.1B GENERAL NOTES AND INFORMATION, SET B FIRE PROTECTION FP2.1 FIRST FLOOR FIRE PROTECTION PLAN FP2.2 SECOND FLOOR FIRE PROTECTION PLAN FP2.3 THIRD FLOOR FIRE PROTECTION PLAN FP2.4 FOURTH FLOOR FIRE PROTECTION PLAN PLUMBING P2.0 UNDERFLOOR PLUMBING PLAN P2.1 FIRST FLOOR PLUMBING PLAN P2.2 SECOND FLOOR PLUMBING PLAN P2.3 THIRD FLOOR PLUMBING PLAN P2.4 FOURTH FLOOR PLUMBING PLAN P2.5 ROOF PLUMBING PLAN P3.1 GAS ISOMETRIC P3.2 PLUMBING ISOMETRICS P4.1 PLUMBING ENLARGED PLANS P4.2 ENLARGED MECHANICAL ROOM PLAN P5.1 PLUMBING DETAILS P6.1 PLUMBING SCHEDULES MECHANICAL M0.1 GENERAL INFORMATION M2.1 FIRST FLOOR HVAC PLAN - BASE BID M2.1A FIRST FLOOR HVAC PLAN - ALTERNATE BID M2.2 SECOND FLOOR HVAC PLAN - BASE BID M2.2A SECOND FLOOR HVAC PLAN - ALTERNATE BID M2.3 THIRD FLOOR HVAC PLAN M2.4 FOURTH FLOOR HVAC PLAN M2.5 MECHANICAL ROOF PLAN M3.1 FIRST FLOOR MECHANICAL PIPING PLAN M3.2 SECOND FLOOR MECHANICAL PIPING PLAN M3.3 THIRD FLOOR MECHANICAL PIPING PLAN M3.4 FOURTH FLOOR MECHANICAL PIPING PLAN M5.1 MECHANICAL ISOMETRICS AND SECTIONS M6.1 MECHANICAL DETAILS - I M6.2 MECHANICAL DETAILS - II M7.1 MECHANICAL EQUIPMENT SCHEDULES M8.1 CONTROL SCHEMATICS - I M8.2 CONTROLS SCHMATICS - II M8.3 CONTROLS SCHMATICS - III ELECTRICAL E0.2 ELECTRICAL GENERAL INOTES E2.1 FIRST FLOOR POWER PLAN E2.2 SECOND FLOOR POWER PLAN E2.3 THIRD FLOOR POWER PLAN E2.4 FOURTH FLOOR POWER PLAN E2.5 FIRST FLOOR POWER CONNECTION PLAN HVAC/PLUMBING EQUIPMENT E2.6 SECOND FLOOR POWER CONNECTION PLAN HVAC/PLUMBING EQUIPMENT E2.7 THIRD FLOOR POWER CONNECTION PLAN HVAC/PLUMBING EQUIPMENT E2.8 FOURTH FLOOR POWER CONNECTION PLAN HVAC/PLUMBING EQUIPMENT E2.9 ENLARGED PLAN - ELECTRICAL PLANS - ELECTRICAL AND IT ROOMS E3.1 FIRST FLOOR LIGHTING PLAN E3.1A FIRST FLOOR LIGHTING PLAN - ALTERNATE E3.2 SECOND FLOOR LIGHTING PLAN E3.2A SECOND FLOOR LIGHTING PLAN - ALTERNATE E3.3 THIRD FLOOR LIGHTING PLAN E3.4 FOURTH FLOOR LIGHTING PLAN E3.5 STAIR ST11 LIGHTING E4.1 FIRST FLOOR SYSTEMS PLAN E4.2 SECOND FLOOR SYSTEMS PLAN E4.3 THIRD FLOOR SYSTEMS PLAN E4.4 FOURTH FLOOR SYSTEMS PLAN E5.1 ELECTICAL DETAILS E5.2 ELECTICAL DETAILS E5.3 ELECTICAL DETAILS E5.4 ELECTICAL DETAILS E5.5 ELECTICAL DETAILS E5.6 ELECTICAL DETAILS E5.7 ELECTICAL DETAILS E5.8 ELECTICAL DETAILS E5.9 ELECTRICAL DETAILS E6.1 CATV RISER DIAGRAM AND TRANSFORMER SCHEDULE E6.2 CONDUIT AND CABLE SCHEDULE - POWER (1 OF 2) E6.3 CONDUIT AND CABLE SCHEDULE - POWER (2 OF 2) E6.4 CONDUIT AND CABLE SCHEDULE (COMMUNICATIONS) E6.5 LIGHT FIXTURE SCHEDULE E7.1 PANELBOARD SCHEDULES E7.2 PANELBOARD SCHEDULES E7.3 PANELBOARD SCHEDULES E7.4 PANELBOARD SCHEDULES E7.5 PANELBOARD SCHEDULES E8.1 ONE-LINE DIAGRAM DRAWING SET A DRAWING SET B SITE INFORMATION Utility Contacts