HomeMy WebLinkAboutP001 - Water Entrance Riser DiagramPLUMBING GENERAL NOTES 1. INSTALLATION OF PLUMBING FIXTURES AND ACCESSORIES, INCLUDING FLUSH CONTROL VALVES INTENDED FOR PEOPLE WITH DISABILITIES, SHALL BE IN ACCORDANCE WITH ADA REQUIREMENTS. 2. INSTALLATION OF PLUMBING PIPING SHALL BE FULLY COORDINATED WITH STRUCTURAL, ARCHITECTURAL, ELECTRICAL, AND HVAC DRAWINGS TO AVOID CONFLICT. 3. NO PLUMBING (WATER, DRAINS, VENT, OR GAS PIPING) SHALL BE INSTALLED DIRECTLY ABOVE ANY ELECTRICAL PANELS. COORDINATE WITH OTHER DIVISIONS BEFORE PROCEEDING WITH INSTALLATION. 4. IF NON DESIGN BASE EQUIPMENT IS SELECTED, CONTRACTOR SHALL BEAR ADDITIONAL COSTS FOR MODIFICATIONS TO THE ORIGINAL SYSTEM(S). 5. PROVIDE WATER HAMMER ARRESTERS AT PLUMBING FIXTURES AND GROUPS OF PLUMBING FIXTURES THAT ARE SUBJECT TO WATER HAMMER. SELECT ARRESTERS IN ACCORDANCE WITH THE PLUMBING AND DRAINAGE INSTITUTE STANDARD. 6. CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIALS, LABOR AND EQUIPMENT PERMIT FEES, REQUIRED FOR, OR INCIDENTAL TO THE INSTALLATION OF A COMPLETE AND OPERATIONAL PLUMBING SYSTEM AS INDICATED IN THE CONTRACT DOCUMENTS INCLUDING SPECIFICATIONS. 7. ALL PLUMBING SERVICES GOING INTO THE BUILDING AND LEAVING THE BUILDING SHALL BE CONNECTED TO THE SITE UTILITIES, COORDINATE WITH SITE UTILITIES DWGS. COORDINATE ALL EXTERIOR UNDERGROUND PLUMBING WORK WITH THE SITE UTILITIES BEFORE COMMENCING WORK. COORDINATE ALL UNDERGROUND PIPING WITH FOUNDATION DRAWINGS. 8. ALL PLUMBING WORK SHALL BE IN CONFORMANCE WITH THE INTERNATIONAL PLUMBING CODE, LATEST EDITION ADOPTED BY THE STATE OF INDIANA WITH INDIANA AMENDMENTS, MUNICIPAL OR CITY CODES, AND THE AUTHORITY HAVING JURISDICTION. 9. INSTALL BALL VALVE CLOSE TO WATER MAIN ON EACH BRANCH AND RISER SERVING PLUMBING EQUIPMENT AND FIXTURES. 10. CONTRACTOR SHALL PROVIDE ACCESS DOORS, WHETHER SPECIFICALLY IDENTIFIED ON THE SHEETS OR NOT, IN ALL WALL AND CEILINGS WHERE SERVICE OR ADJUSTMENT TO PLUMBING ITEMS MAY BE REQUIRED. ACCESS DOORS SHALL BE OF AN APPROPRIATE SIZE REQUIRED FOR EACH APPLICATION. WHERE APPLICABLE, ACCESS DOORS SHALL MATCH THE FIRE RATING OF THE WALL / CEILING ASSEMBLY. 11. REFER TO DIVISION 23 SPECIFICATIONS FOR FACILITY NATURAL GAS REQUIREMENTS. 12. REFER TO ARCHITECTURAL ROOF DRAWINGS FOR ROOF DIMENSIONS. 13. PROVIDE SIZES TO FIXTURES AS INDICATED ON PLANS, RISERS AND SECTIONS. IF SIZE NOT INDICATED, PROVIDE SIZE SHOWN ON PLUMBING FIXTURE SCHEDULE. 14. COORDINATE SLEEVING REQUIREMENTS WITH PAN JOISTS WHERE REQUIRED WITH STRUCTURAL DRAWINGS. 15. REFERENCE SECTIONS AND RISER / ISOMETRICS FOR ADDITIONAL INFORMATION ON PIPE SIZES NOT SHOWN IN PLAN VIEWS. 16. ALL SHUT-OFF VALVES LOCATED ABOVE THE CEILING THROUGHOUT THE BUILDING SHALL BE WITHIN 24" OF THE CEILING. 17. INSTALLATION OF EQUIPMENT SHALL BE AS PER MANUFACTURER'S WRITTEN RECOMMENDATIONS. IF PLANS OR DETAILS DIFFER FROM THOSE RECOMMENDATIONS, REQUEST DIRECTION FROM THE ARCHITECT BEFORE CONTINUING. COLD WATER GAS -5,085 CFH -323 WSFU'S SANITARY STORM (ROOF)-26,730 S.F. -160.5 DFU'S PLUMBING BASIS OF DESIGN HOT WATER -65.5 WSFU'S PLUMBING SYMBOLS HW SAN SAN DOMESTIC HOT WATER SANITARY ABOVE GROUND SANITARY BELOW GROUND STM V STORM ABOVE GROUND ABOVE GROUND VENT CW DOMESTIC COLD WATER SHUT-OFF VALVE (SEE SPECIFICATIONS) CALIBRATED BALANCING VALVE CHECK VALVE V BELOW GROUND VENT A COMPRESSED AIR HWR DOMESTIC HOT WATER RETURN G NATURAL GAS SINGLE LINE - PIPE DROP SINGLE LINE - PIPE RISE SINGLE LINE - PIPE RISE TEE SINGLE LINE - PIPE DROP TEE TWO LINE - PIPE DROP TWO LINE - PIPE RISE STM STORM BELOW GROUND HW-140 DOMESTIC HOT WATER (140) SCW DOMESTIC SOFT COLD WATER HWR BALANCING VALVE OR EQUIPMENT ABBREVIATIONS AD CB DF DWBP EWC FCO FD FS GI HB LAV MS OI ORD RD RCP SH S TD TMV UR WH WC WH WTS AREA DRAIN CATCH BASIN DRINKING FOUNTAIN DOMESTIC WATER BOOSTER PUMP ELECTRIC WATER COOLER FLOOR CLEAN OUT FLOOR DRAIN FLOOR SINK GREASE INTERCEPTOR HOSE BIBB LAVATORY MOP SINK OIL INTERCEPTOR OVERFLOW ROOF DRAIN ROOF DRAIN RECIRCULATING PUMP SHOWER SINK TRENCH DRAIN THERMOSTATIC MIXING VALVE URINAL WALL HYDRANT WATER CLOSET WATER HEATER WATER TREATMENT SYSTEM PLUMBING ABBREVIATIONS AFF AFG BT BV CONT CW DN DWG. ELEV. FBG FFA FFB G GPM HW HWR IE LKW MAX MIN OS&Y PHE SAN STM SF TS TBG TFA TFB TYP V VTR W ABOVE FINISHED FLOOR ABOVE FINISHED GRADE BRINE TANK BALANCING VALVE CONTINUATION COLD WATER DOWN DRAWING ELEVATION FROM BELOW GRADE FROM FLOOR ABOVE FROM FLOOR BELOW NATURAL GAS GALLONS PER MINUTE HOT WATER HOT WATER RETURN INVERT ELEVATION LAVATORY KITCHEN WASTE MAXIMUM MINIMUM OUTSIDE SCREW & YOKE PLATE HEAT EXCHANGER SANITARY STORM SQUARE FEET TEMPERATURE SENSOR TO BELOW GRADE TO FLOOR ABOVE TO FLOOR BELOW TYPICAL VENT VENT THROUGH ROOF WASTE REFER TO P2.1 FOR CONTINUATION. DWBP-2 DWBP-1 4" CW4" CW4" CW 4" CW 4" CW4 " C W 4" OS&Y SHUT-OFF VALVE. WATER METER PROVIDED BY LOCAL UTILITY COMPANY. COORDINATE REQUIRED LENGTH NEEDED BETWEEN SHUTOFF VALVE AND BACKFLOW PREVENTER DEVICE. Y-STRAINER RPZ-1 WTS-1 WTS-2 NOTE: PIPING ISOMETRIC FOR DIAGRAMATIC PURPOSES ONLY. PIPE PER MANUFACTURER RECOMMENDATIONS. BY-PASS LINE FOR DOMESTIC WATER BOOSTER PUMPS WITH SHUT-OFF VALVE. CW LINE TO TPM-1. REFER TO P2.1 FOR CONTINUATION. 4" OS&Y SHUT-OFF VALVE FOR WATER MAIN AFTER DWBP (TYP. 2)DLZ INDIANA, LLCDRAWING NUMBERPROJECT NUMBERDATE:APPRV'D:DESIGNED:DRAWN:CHK'D:8/20/2020 2:00:08 PMC:\RevitBackups\2020\1963-1025-90_AdminBldg_MEP_sbhat6T6FS.rvtP0.1COMMUNITY BUILDINGCARMEL CLAY1963-1025-90SSBESAESAJULY 28, 2020SSBGENERAL NOTES, SYMBOLS, AND ABBREVIATIONSPLUMBINGCARMELINDIANABID PACKAGE 2BACKFLOW PREVENTER SCHEDULE TAG DESCRIPTION BASIS OF DESIGN NOTES RPZ 1 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER: ASSE 1013 APPROVED. MAIN BODY AND ACCESS COVER SHALL BE EPOXY COATED DUCTILE IRON (ASTM A 536 GRADE 4). THE SEAT RING AND CHECK VALVE SHALL BE NORYL, THE STEM SHALL BE STAINLESS STEEL (ASTM A 276) AND THE SEAT DISC ELASTOMERS SHALL BE EPDM. ZURN WILKINS MODEL 375ADA-4" OR EQUIVALENT. INSTALL PER MFGR AND WATER UTILITY REQUIREMENTS RPZ 2 REDUCED PRESSURE BACKFLOW PREVENTER ASSEMBLY: ASSE 1013 APPROVED. INCLUDES METERED BY-PASS TO DETECT LEAKS AND UNAUTHORIZED WATER USE. MAIN BODY AND ACCESS COVER SHALL BE EPOXY COATED DUCTILE IRON (ASTM A 536 GRADE 4). THE SEAT RING AND CHECK VALVE SHALL BE NORYL, THE STEM SHALL BE STAINLESS STEEL (ASTM A 276) AND THE SEAT DISC ELASTOMERS SHALL BE EPDM. ZURN WILKINS MODEL 375ADA-2" OR EQUIVALENT INSTALL PER MFGR REQUIREMENTS.(10 PSI) SCALE: NTSP0.1 1 DOMESTIC WATER ENTRANCE RISER DIAGRAM NO.REVISIONDATE