Loading...
HomeMy WebLinkAboutAG-502 - GARAGE DETAILSGARAGE GROUND TIER99'-7"G-C4"1'-2"8"042000.A01A072726.A00042000.B0104-A2SEE CIVIL DWGS FOR GRADING INFORMATIONG-CREGLET2 1/2"T/ WALL104'-7"T/ BRICK103'-7"1'-0"1"8"2"1/2"084413.A00PANEL SYSTEM ANCHOR SEE:F2 / AG-201PANEL SYSTEM BASE EXTRUSION 2"x8"PROVIDE WEEP HOLES, TYPICAL1"076200.A01ON CONT. CLEAT042000.A01A033000.A05G-CT/ WALLREFER TO GARAGE7"x4"x3/8" GALV. STEEL ANGLE SET INTO CONCRETE WALL W/ EXPANSION ANCHORS @ 16" O.C. -LOCATE BETWEEN METAL PANEL SYSTEM SUPPORTS LESS 1" ON EACH ENDSTRUCT DWGS1'-0"1"8"084413.A005"055000.A00GARAGE SECOND TIER110'-11"G-A1'-0"1"084413.A00PANEL SYSTEM ANCHOR SEE:F2 / AG-201PANEL SYSTEM BASE EXTRUSION 2"x8"PROVIDE WEEP HOLES, TYPICALBTM/ PANEL SYSTEM109'-1 1/2"GARAGE STRUCTUREGARAGE CLEARANCE BAR -SEE GARAGE STRUCT DWGSG-C1'-1"8"PANEL SYSTEM TOP EXTRUSION 2"x8"084413.A00T/ MTL PANEL SYSTEM127'-7 1/2"GARAGE GROUND TIER99'-7"G-1084113.B03SEE CIVIL DWGS FOR PAVEMENT INFORMATION11 5/8"PROVIDE INTUMESCENT FIRE PROOFING AT COLUMNS, TYPICAL AT GARAGE LOBBIES051200.A00033000.A02SHIM AS REQ'D079200.C01TYP. EACH SIDEGARAGE SECOND TIER110'-11"G-14 1/8"1'-1 3/4"2 1/4"9 1/4"2 1/4"11 5/8"HEAD109'-7"T/ FRAMING114'-11 3/8"6"4"1"MANUF. STD WINDOW FLASHINGS AND TRIMWRAP AIR/MOISTURE BARRIER UNDER PLYWOODTYP. EACH SIDEPROVIDE INTUMESCENT FIRE PROOFING AT COLUMNS, TYPICAL AT GARAGE LOBBIES079200.C01084113.B03092900.B04061053.F05051200.A00078100.A002 LAYERS053100.B01075423.A02075423.C01061600.D025/8"076200.D07MANUF. STD BASE FLASHINGS AND TRIM074213.13.A00061600.B01054000.B03074213.13.A00072726.A00072726.A00061600.B01077100.A01061053.F052 LAYERSWRAP LAYER OF ROOFING MEMBRANE OVER TOP OF WALLEXTEND AIR/MOISTURE BARRIER UP AND UNDER ROOFING MEMBRANE, EACH SIDEMANUF. STD CAP FLASHINGS AND TRIM1'-5"GARAGE SECOND TIER110'-11"G-227D6AG-501084413.A00PANEL SYSTEM BASE EXTRUSION 2"x8"PROVIDE WEEP HOLES, TYPICALBTM/ PANEL SYSTEM115'-3 1/2"T/ FRAMING114'-11 3/8"074213.13.A00072726.A00061600.B01054000.B02MANUF. STD BASE FLASHINGS AND TRIM076200.D07061600.A00075423.C01075423.A025/8"053100.B01051200.A00078100.A00MANUF. STD CAP FLASHINGS AND TRIMEXTEND AIR/MOISTURE BARRIER UP AND UNDER ROOFING MEMBRANE.WRAP LAYER OF ROOFING MEMBRANE OVER TOP OF WALL4"1"6"061053.F052 LAYERS077100.A01061053.F05REGLET076200.A01079200.A01GARAGE STRUCTURE1'-5"2"1'-0"GARAGE THIRD TIER121'-3"GARAGE STRUCTURE079513.19.B01079513.19.E012"2"084113.B03SHIM AS REQ'D078100.A00051200.A00033000.A01079200.C01TYP, EACH SIDETOP OF STEEL-BRIDGE132'-11 1/2"HEAD129'-5"074213.13.A00072100.A01072726.A00061600.B01MANUF. STD CAP FLASHINGS AND TRIMWRAP AIR/MOISTURE BARRIER UP AND UNDER MEMBRANE FLASHINGTHROUGH-WALL AND WALL FLASHING BEYOND -EXTEND FLASHING OUT UNDER COPING SYSTEM, ABOVE MEMBRANE FLASHING6"T/ FRAMING134'-4"1"4"077100.A01EXTEND MEMBRANE FLASHING OVER TOP OF WALL061053.F052 LAYERS1'-0 1/2"10 1/2"2"076200.D07BEYOND075423.C01061600.A00075423.A02FILL STUD CAVITY W/ BATT INSUL.PROVIDE CROSS CHANNEL TO SUPPORT INSUL.053100.B01051200.A00078100.A0009-A4054000.B02092900.B043/8"061053.F05079200.A01079200.C01084113.B032 LAYERSTYP EACH SIDEWRAP AIR/MOISTURE BARRIER AROUND END OF PLYWOODMANUF. STD WINDOW FLASHINGS AND TRIMGARAGE SECOND TIER110'-11"H.92 3/4"1'-4 3/4"2 1/4"1'-0 1/4"2 1/4"PROVIDE INTUMESCENT FIRE PROOFING AT COLUMNS, TYPICAL AT GARAGE LOBBIESPANEL MANUF. STD BASE FLASHINGS AND TRIM033000.A01078100.B01051200.A00074213.13.A1061600.B01054000.B03075423.A02075423.C01061600.A005/8" PLYWOOD076200.D07PANEL MANUF. STD BASE FLASHINGS AND TRIM074213.13.A1072100.A01072726.A00061600.B01053100.B011'-1 5/8"GARAGE THIRD TIER121'-3"G-BH.91/4"1 3/4"2'-8 1/4"5"1'-2 1/2"092900.B04054000.B03061600.B01033000.A01051200.A00078100.B01079513.19.E01MANUF. STD AND MODIFIED BASE FLASHINGS AND TRIMRECEIVER -SET IN SEALANT, HEM EXPOSED EDGESPARKING GARAGE STRUCTURE074213.13.A00ALIGN JOINTS W/ WALL BEHIND072100.A01072726.A00061600.B011'-6 1/4"2"1'-0"3GARAGE SECOND TIER110'-11"G-13 1/8"1'-2 3/4"2 1/4"10 1/4"2 1/4"MANUF. STD WINDOW FLASHINGS AND TRIMWRAP AIR/MOISTURE BARRIER AROUND END OF PLYWOODHEAD109'-7"079200.C01084113.B03TYP. EACH SIDE074213.13.A00072100.A01072726.A00061600.B01074213.13.A00061600.B01054000.B02033000.A01051200.A00078100.B0111 5/8"PROVIDE INTUMESCENT FIRE PROOFING AT COLUMNS, TYPICAL AT GARAGE LOBBIES1'-0"PANEL MANUF. STD BASE FLASHINGS AND TRIMSHIM AS REQ'DSHEET TITLESHEET NUMBERCARMEL CLAY PUBLIC LIBRARY55 4th Ave. SECarmel, IN 46032317-814-3900OwnerRATIO Architects, Inc.101 South Pennsylvania StreetIndianapolis, Indiana 46204317-633-4040ArchitectCE Solutions, Inc.Structural EngineerMechanical / Electrical EngineerCivil Engineer10 Shoshone DriveCarmel, IN 46032317-818-1912KBSO Consulting, LLC1344 South Rangeline, Suite 202Carmel, IN 46032317-344-8044Civil & Environmental Consultants, Inc.530 E. Ohio Street, Suite GIndianapolis, IN 46204317-655-7777PROJECT NO.COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.SHEET ISSUESEAL | DATETechnology DesignDesign 271650 East 49th StreetIndianapolis, IN 46205317-536-8000Garage ConsultantWalker Consultants6602 East 75th Street, Suite 210Indianapolis, IN 46250317-842-68908/3/2020 4:10:17 PMAG-502GARAGE DETAILS18104.000CARMEL CLAYPUBLIC LIBRARYRENOVATION55 4th Avenue SECarmel, IN 46032KEYNOTES (ACTION)04-A2 GROUT SOLID BELOW FLASHING09-A4 CEILING, REFER TO REFLECTED CEILING PLANFOR TYPEKEYNOTES (SPEC BASED)033000.A01 CAST-IN-PLACE CONCRETE, REFERENCESTRUCTURAL033000.A02 CAST-IN-PLACE CONCRETE SLAB033000.A05 CAST-IN-PLACE CONCRETE WALL042000.A01A FACE BRICK, TYPE A042000.B01 MASONRY VENEER, FLASHING051200.A00 STRUCTURAL STEEL FRAMING053100.B01 ROOF DECK054000.B02 COLD-FORMED METAL FRAMING - 6" WITH SOUNDATTENUATION054000.B03 COLD-FORMED METAL FRAMING - 8" WITH SOUNDATTENUATION055000.A00 METAL FABRICATIONS061053.F05 MISCELLANEOUS ROUGH CARPENTRY,PLYWOOD, 3/4"061600.A00 SHEATHING061600.B01 WALL SHEATHING061600.D02 PARAPET SHEATHING, PLYWOOD, 1/2"072100.A01 EXTRUDED POLYSTYRENE BOARD INSULATION(RIGID)072726.A00 FLUID APPLIED MEMBRANE AIR BARRIER074213.13.A00 FORMED METAL WALL PANELS074213.13.A1075423.A02 TPO ROOFING SYSTEM075423.C01 TPO ROOFING, FLASHING076200.A01 SHEET METAL FLASHING AND TRIM076200.D07 TWO PIECE RECEIVER AND COUNTERFLASHING077100.A01 COPING, METAL, MANUFACTURED078100.A00 APPLIED FIREPROOFING078100.B01 1 HOUR RATED SPRAYED FIRE RESISTIVEMATERIAL079200.A01 SEALANT079200.C01 BACKER ROD AND SEALANT079513.19.B01 METAL-PLATE PARKING DECK JOINT COVER079513.19.E01 EPOXY-BONDED-SEAL PARKING DECK JOINTCOVER084113.B03 ALUMINUM-FRAMED ENTRANCES ANDSTOREFRONTS - EXTERIOR, 6" FRAME DEPTH084413.A00 GLAZED ALUMINUM CURTAIN WALLS092900.B04 GYPSUM BOARD, 5/8"1 1/2" = 1'-0"AG-502A6SECTION DETAIL1 1/2" = 1'-0"AG-502B6SECTION DETAIL1 1/2" = 1'-0"AG-502D6SECTION DETAIL1 1/2" = 1'-0"AG-502A5SECTION DETAIL1 1/2" = 1'-0"AG-502E6SECTION DETAIL1 1/2" = 1'-0"AG-502A3SECTION DETAIL1 1/2" = 1'-0"AG-502B3SECTION DETAIL1 1/2" = 1'-0"AG-502A1SECTION DETAIL1 1/2" = 1'-0"AG-502D1SECTION DETAIL1 1/2" = 1'-0"AG-502E1SECTION DETAIL1 1/2" = 1'-0"AG-502D5SECTION DETAIL1 1/2" = 1'-0"AG-502F3SECTION DETAIL1 1/2" = 1'-0"AG-502B5SECTION DETAIL1 100% CONSTRUCTION DOCUMENTS 7/14/202 STATE SUBMISSION SET 7/17/203 Addendum 1 7/31/207/31/20