Loading...
HomeMy WebLinkAboutG-002-2 - VOLUME 2 -SHEET INDEX, PROJ LOCATION AND GENERAL NOTESPROJECT SITEPROJECT SITEA. THE FOLLOWING GENERAL NOTES APPLY TO THESE CONTRACT DOCUMENTS AND ARE NOT SPECIFIC TO ANY ONE DISCIPLINE.B. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY.C. PARTIAL SETS OF DRAWINGS ARE INCOMPLETE AND SHOULD NOT BE DISTRIBUTED OR UTILIZED BY THE CONTRACTOR.D. THE CONSTRUCTION DOCUMENTS ESTABLISH DETAILED MINIMUM REQUIREMENTS FOR THE CONSTRUCTION OF THE PROJECT.E. THE GENERAL NOTES, SYMBOLS AND DEFINITIONS APPLICABLE ONLY TO EACH DISCIPLINE CAN BE FOUND AT THE FRONT OF EACH DISCIPLINES PORTION OF THE SET OF DRAWINGS AND IS LISTED AS PART OF THE OVERALL PROJECT INDEX OF DRAWINGS. F. BASIC FIRE PROTECTION AND THE EXITING SCHEME ARE ILLUSTRATED BY THE LIFE SAFETY PLAN(S) AND APPLICABLE FIRE AND BUILDING CODE SUMMARY ON SHEET G-003.G. THE ARCHITECTURAL DRAWINGS ESTABLISH, COORDINATE, AS WELL AS TAKE PRECEDENCE FOR THE FINISH APPEARANCE OF ALL EXPOSED ELEMENTS OF THE WORK OF ALL TRADES INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES.H. THE DRAWINGS MAY MAKE REFERENCE TO AND/OR ILLUSTRATE ITEMS WHICH ARE NOT PART OF THE WORK OF THE CONTRACT. THESE NOT IN CONTRACT ITEMS ARE REFERENCED AND/OR ILLUSTRATED FOR THE CONTRACTORS REFERENCE, INFORMATION, AND COORDINATION ONLY.I. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH APPLICABLE LAWS, CODES, REGULATIONS, AND ORDINANCES OF THE PLACE (CITY, COUNTY, DISTRICT AND STATE) WHERE THE PROJECT IS LOCATED. SUCH REQUIREMENTS MAY NOT BE REFLECTED BY THESE CONTRACT DOCUMENTS.J. EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE RECORD DRAWINGS AND OR VISUAL FIELD SURVEYS. THE CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS AT THE SITE PRIOR TO SUBMITTING A BID. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.K. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASES REQUIRED FOR THE CONSTRUCTION AND OCCUPANCY OF THE PROJECT. THE CONTRACTOR SHALL FURNISH COPIES OF ALL SUCH ITEMS TO THE OWNER AND ARCHITECT WITHIN 10 DAYS OF RECEIPT OF SUCH ITEMS. IF PERMITS ARE ISSUED SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE WORK OR IF PERMITS ARE DELAYED FOR ANY REASON, THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT.L. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO MAINTAIN AND PROTECT NEW WORK AS WELL AS EXISTING SYSTEMS AND ELEMENTS WHICH ARE TO REMAIN. ANY DAMAGE TO SUCH SYSTEMS AND ELEMENTS SHALL BE IMMEDIATELY REPAIRED IN A MANNER ACCEPTABLE TO THE ARCHITECT. IF SATISFACTORY REPAIRS CANNOT BE MADE, THE CONTRACTOR SHALL REPLACE SYSTEMS AND ELEMENTS WITH LIKE NEW QUALITY ACCEPTABLE TO THE ARCHITECT. ALL REPAIRS AND REPLACEMENT COST SHALL BE THE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR.SHEET TITLESHEET NUMBERCARMEL CLAY PUBLIC LIBRARY55 4th Ave. SECarmel, IN 46032317-814-3900OwnerRATIO Architects, Inc.101 South Pennsylvania StreetIndianapolis, Indiana 46204317-633-4040ArchitectCE Solutions, Inc.Structural EngineerMechanical / Electrical EngineerCivil Engineer10 Shoshone DriveCarmel, IN 46032317-818-1912KBSO Consulting, LLC1344 South Rangeline, Suite 202Carmel, IN 46032317-344-8044Civil & Environmental Consultants, Inc.530 E. Ohio Street, Suite GIndianapolis, IN 46204317-655-7777PROJECT NO.COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.SHEET ISSUESEAL | DATETechnology DesignDesign 271650 East 49th StreetIndianapolis, IN 46205317-536-8000Garage ConsultantWalker Consultants6602 East 75th Street, Suite 210Indianapolis, IN 46250317-842-68908/3/2020 3:10:28 PMG-002-2VOLUME 2 - SHEETINDEX, PROJLOCATION ANDGENERAL NOTES18104.000CARMEL CLAYPUBLIC LIBRARYRENOVATION55 4th Avenue SECarmel, IN 46032Sheet # Sheet NameSTRUCTURALSG-001 STRUCTURAL GENERAL NOTESSG-003 POST-TENSION POUR SEQUENCESG-100 FOUNDATION PLANSG-101 GROUND TIER PLANSG-102 SECOND TIER PLANSG-103 TOP TIER PLANSG-410 STAIR TOWER NO. 1 ENLARGED PLANSSG-501 TYPICAL DETAILSSG-510 FOUNDATION DETAILSSG-530 CIP BEAM DETAILS/CIP COLUMN DETAILSSG-535 SLAB DETAILSSG-540 BUMPER WALL DETAILSSG-550 CIP COLUMN SCHEDULE AND DETAILSSG-570 STAIR DETAILSSG-580 MASONRY DETAILSSG-690 LAP SPLICE SCHEDULESARCH GRAPHICSAGG-101 GROUND TIER PLANAGG-102 SECOND TIER PLANAGG-103 TOP TIER PLANAGG-201 GROUND TIER SIGNAGE PLANAGG-202 SECOND TIER SIGNAGE PLANAGG-203 TOP TIER SIGNAGE PLANAGG-601 SIGN SCHEDULE AND DETAILSAGG-701 SIGN MOUNTING DETAILSGARAGE ARCHITECTUREAG-111 GROUND TIER GARAGE PLANAG-112 SECOND TIER GARAGE PLANAG-113 THIRD TIER GARAGE PLANAG-201 GARAGE ELEVATIONSAG-202 GARAGE ELEVATIONSAG-301 GARAGE WALL SECTIONSAG-302 GARAGE WALL SECTIONSAG-303 GARAGE WALL SECTIONSAG-411 GARAGE STAIR AND ELEVATOR PLANSAG-412 GARAGE STAIR AND ELEVATOR SECTIONSAG-501 GARAGE DETAILSAG-502 GARAGE DETAILSAG-503 GARAGE DETAILSAG-601 GARAGE DOOR SCHEDULE AND DETAILSPLUMBINGPG-001 GENERAL NOTES, SYMBOLS & ABBREVIATIONSPG-101 GROUND TIER PLANPG-102 SECOND TIER PLANPG-103 TOP TIER PLANPG-601 RISER DIAGRAMS AND ENLARGED WATER ROOM PLANFIRE PROTECTIONFG-001 GENERAL NOTES, SYMBOLS & ABBREVIATIONSFG-101 GROUND TIER PLANFG-102 SECOND TIER PLANFG-103 TOP TIER PLANFG-601 STANDPIPE RISER DIAGRAMELECTRICAL/MECHANICALEMG-001 LIGHT FIXTURE SCHEDULE AND GENERAL NOTESEMG-101 GROUND TIER PLANEMG-102 SECOND TIER PLANEMG-103 TOP TIER PLANEMG-401 ENLARGED ROOM PLANEMG-410 NORTH STAIR/ELEVATOR PLANSEMG-420 SOUTH STAIR PLANSEMG-501 DETAILSEMG-601 RISER DIAGRAMSEMG-602 ELECTRICAL PANEL & MECHANICAL EQUIPMENTSCHEDULESEMG-603 POWER ONE LINE DIAGRAMG-TECHT201G GROUND TIER GARAGE TELECOM PLANT202G SECOND TIER GARAGE TELECOM PLANT203G THIRD TIER GARAGE TELECOM PLANSheet # Sheet NameELECTRICALE-001 ELECTRICAL SYMBOLS & ABBREVIATIONSED-101 FIRST FLOOR LIGHTING DEMOLITION PLANED-102 SECOND FLOOR LIGHTING DEMOLITION PLANED-111 FIRST FLOOR POWER DEMOLITION PLANED-112 SECOND FLOOR POWER DEMOLITION PLANED-401 ENLARGED ELECTRICAL DEMOLITION PLANSES-101 SITE PLAN - ELECTRICALES-102 SITE PLAN - PHOTOMETRICES-103 CUTSHEETSES-104 CUTSHEETSEL-101 FIRST FLOOR LIGHTING PLAN - OVERALLEL-101A FIRST FLOOR LIGHTING PLAN - AREA AEL-101B FIRST FLOOR LIGHTING PLAN - AREA BEL-101C FIRST FLOOR LIGHTING PLAN - AREA CEL-101D FIRST FLOOR LIGHTING PLAN - AREA DEL-102 SECOND FLOOR LIGHTING PLAN - OVERALLEL-102A SECOND FLOOR LIGHTING PLAN AREA AEL-102B SECOND FLOOR LIGHTING PLAN - AREA BEL-102C SECOND FLOOR LIGHTING PLAN - AREA CEL-102D SECOND FLOOR LIGHTING PLAN - AREA DEL-103 CLERESTORY LIGHTING PLAN - OVERALLEP-101 FIRST FLOOR POWER PLAN - OVERALLEP-101A FIRST FLOOR POWER PLAN - AREA AEP-101B FIRST FLOOR POWER PLAN - AREA BEP-101C FIRST FLOOR POWER PLAN - AREA CEP-101D FIRST FLOOR POWER PLAN - AREA DEP-102 SECOND FLOOR POWER PLAN - OVERALLEP-102A SECOND FLOOR POWER PLAN - AREA AEP-102B SECOND FLOOR POWER PLAN - AREA BEP-102C SECOND FLOOR POWER PLAN - AREA CEP-102D SECOND FLOOR POWER PLAN - AREA DEP-103 ROOF ELECTRICAL PLAN - OVERALLEF-101 FIRST FLOOR FIRE ALARM PLAN - OVERALLEF-102 SECOND FLOOR FIRE ALARM PLAN - OVERALLE-401 ENLARGED ELECTRICAL PLANSE-402 ENLARGED ELECTRICAL PLANSE-403 ENLARGED ELECTRICAL PLANSE-404 ENLARGED ELECTRICAL PLANE-501 ELECTRICAL DETAILSE-601 ELECTRICAL SCHEDULESE-602 ELECTRICAL SCHEDULESE-603 ELECTRICAL SCHEDULESE-604 ELECTRICAL SCHEDULESE-605 ELECTRICAL SCHEDULESE-901 ELECTRICAL RISER DIAGRAMTECHTD201 FIRST FLOOR DEMO PLAN - OVERALLTD201A FIRST FLOOR DEMO PLAN - AREA ATD201B FIRST FLOOR DEMO PLAN - AREA BTD201C FIRST FLOOR DEMO PLAN - AREA CTD201D FIRST FLOOR DEMO PLAN - AREA DTD202 SECOND FLOOR DEMO PLAN - OVERALLTD202A SECOND FLOOR DEMO PLAN - AREA ATD202B SECOND FLOOR DEMO PLAN - AREA BTD202C SECOND FLOOR DEMO PLAN - AREA CTD202D SECOND FLOOR DEMO PLAN - AREA DT101 FIRST FLOOR DISTRIBUTION PLAN - OVERALLT101A FIRST FLOOR DISTRIBUTION PLAN - AREA AT101B FIRST FLOOR DISTRIBUTION PLAN - AREA BT101C FIRST FLOOR DISTRIBUTION PLAN - AREA CT101D FIRST FLOOR DISTRIBUTION PLAN - AREA DT102 SECOND FLOOR DISTRIBUTION PLAN - OVERALLT102A SECOND FLOOR DISTRIBUTION PLAN - AREA AT102B SECOND FLOOR DISTRIBUTION PLAN - AREA BT102C SECOND FLOOR DISTRIBUTION PLAN - AREA CT102D SECOND FLOOR DISTRIBUTION PLAN - AREA DT201A FIRST FLOOR TELECOM PLAN - AREA AT201B FIRST FLOOR TELECOM PLAN - AREA BT201C FIRST FLOOR TELECOM PLAN - AREA CT201D FIRST FLOOR TELECOM PLAN - AREA DT202A SECOND FLOOR TELECOM PLAN - AREA AT202B SECOND FLOOR TELECOM PLAN - AREA BT202C SECOND FLOOR TELECOM PLAN - AREA CT202D SECOND FLOOR TELECOM PLAN - AREA DT300 TELECOM DIAGRAMST301 TELECOM DIAGRAMST302 ENLARGED TELECOM ROOM LAYOUTST303 TELECOM RACK ELEVATIONST304 AV DIAGRAMST307 SECURITY DIAGRAMST400 TELECOM DETAILST401 TELECOM & SECURITY DETAILST402 SECURITY DETAILST403 SECURITY DETAILST500 TELECOM SCHEDULEST501 SECURITY SCHEDULESSheet # Sheet NameGENERALG-001-2 COVER - VOLUME 2G-002-2 VOLUME 2 - SHEET INDEX, PROJ LOCATION AND GENERALNOTESFIRE PROTECTIONFPD-101 FIRST FLOOR FIRE PROTECTION DEMOLITION PLANFPD-102 SECOND FLOOR FIRE PROTECTION DEMOLITION PLANFP-101 FIRST FLOOR FIRE PROTECTION PLANFP-102 SECOND FLOOR FIRE PROTECTION PLANPLUMBINGP-001 PLUMBING SYMBOLS & ABBREVIATIONSPD-100 FOUNDATION PLUMBING DEMOLITION PLANPD-101 FIRST FLOOR PLUMBING DEMOLITION PLANPD-102 SECOND FLOOR PLUMBING DEMOLITION PLANPD-103 ROOF PLUMBING DEMOLITION PLANP-100 FOUNDATION PLUMBING PLAN - OVERALLP-100A FOUNDATION PLUMBING PLAN - AREA AP-100B FOUNDATION PLUMBING PLAN - AREA BP-100C FOUNDATION PLUMBING PLAN - AREA CP-100D FOUNDATION PLUMBING PLAN - AREA DP-101 FIRST FLOOR PLUMBING PLAN - OVERALLP-101A FIRST FLOOR PLUMBING PLAN - AREA AP-101B FIRST FLOOR PLUMBING PLAN - AREA BP-101C FIRST FLOOR PLUMBING PLAN - AREA CP-101D FIRST FLOOR PLUMBING PLAN - AREA DP-102 SECOND FLOOR PLUMBING PLAN - OVERALLP-102A SECOND FLOOR PLUMBING PLAN - AREA AP-102B SECOND FLOOR PLUMBING PLAN - AREA BP-102C SECOND FLOOR PLUMBING PLAN - AREA CP-102D SECOND FLOOR PLUMBING PLAN - AREA DP-103 ROOF PLUMBING PLANP-401 PLUMBING ENLARGED PLANSP-501 PLUMBING DETAILSP-601 PLUMBING SCHEDULESP-602 PLUMBING SCHEDULESP-901 PLUMBING DIAGRAMSMECHANICALM-001 MECHANICAL SYMBOLS AND ABBREVIATIONSMD-101 FIRST FLOOR MECHANICAL DEMOLITION PLANMD-102 SECOND FLOOR MECHANICAL DEMOLITION PLANMD-103 MECHANICAL ROOF DEMOLITION PLANMD-401 ENLARGED MECHANICAL DEMOLITION PLANSMH-101 FIRST FLOOR MECHANICAL DUCTWORK PLAN - OVERALLMH-101A FIRST FLOOR MECHANICAL DUCTWORK PLAN - AREA AMH-101B FIRST FLOOR MECHANICAL DUCTWORK PLAN - AREA BMH-101C FIRST FLOOR MECHANICAL DUCTWORK PLAN - AREA CMH-101D FIRST FLOOR MECHANICAL DUCTWORK PLAN - AREA DMH-102 SECOND FLOOR MECHANICAL DUCTWORK PLAN - OVERALLMH-102A SECOND FLOOR MECHANICAL DUCTWORK PLAN - AREA AMH-102B SECOND FLOOR MECHANICAL DUCTWORK PLAN - AREA BMH-102C SECOND FLOOR MECHANICAL DUCTWORK PLAN - AREA CMH-102D SECOND FLOOR MECHANICAL DUCTWORK PLAN - AREA DMH-103 ROOF MECHANICAL PLAN - OVERALLMH-103A ROOF MECHANICAL PLAN - AREA AMH-103B ROOF MECHANICAL PLAN - AREA BMH-103C ROOF MECHANICAL PLAN - AREA CMH-103D ROOF MECHANICAL PLAN - AREA DMP-101 FIRST FLOOR MECHANICAL PIPING PLAN - OVERALLMP-101A FIRST FLOOR MECHANICAL PIPING PLAN - AREA AMP-101B FIRST FLOOR MECHANICAL PIPING PLAN - AREA BMP-101C FIRST FLOOR MECHANICAL PIPING PLAN - AREA CMP-101D FIRST FLOOR MECHANICAL PIPING PLAN - AREA DMP-102 SECOND FLOOR MECHANICAL PIPING PLAN - OVERALLMP-102A SECOND FLOOR MECHANICAL PIPING PLAN - AREA AMP-102B SECOND FLOOR MECHANICAL PIPING PLAN - AREA BMP-102C SECOND FLOOR MECHANICAL PIPING PLAN - AREA CMP-102D SECOND FLOOR MECHANICAL PIPING PLAN - AREA DM-301 MECHANICAL SECTIONSM-401 ENLARGED MECHANICAL PLANSM-501 MECHANICAL DETAILSM-502 MECHANICAL DETAILSM-503 MECHANICAL DETAILSM-504 MECHANICAL DETAILSM-601 MECHANICAL SCHEDULESM-602 MECHANICAL SCHEDULESM-901 TEMPERATURE CONTROL DIAGRAMSM-902 TEMPERATURE CONTROL DIAGRAMSM-903 TEMPERATURE CONTROL DIAGRAMSM-904 TEMPERATURE CONTROL DIAGRAMSPROJECT LOCATIONREGION MAPGENERAL PROJECT NOTESDRAWING INDEX - VOLUME 21 100% CONSTRUCTION DOCUMENTS 7/14/202 STATE SUBMISSION SET 7/17/203 Addendum 1 7/31/207/31/20GARAGEGARAGEGARAGEGARAGEGARAGEGARAGE3