Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S001 - 411FA
8" 23' - 4" 8" 2 CAR GARAGE 8" 24' - 8" 8" 14' - 4" 8" 15' - 4" 9' - 0" 8' - 8" 8" SLAB RECESSED 4" BASEMENT 4" CONCRETE SLAB OVER 6 MIL VAPOR BARRIER OVER 4" MIN GRANULAR FILL 4" CONCRETE SLAB OVER 4" MIN GRANULAR FILL 4" CONCRETE SLAB OVER 4" MIN GRANULAR FILL 4" CONCRETE SLAB OVER 4" MIN GRANULAR FILL COVERED PORCH FRONT PORCH 42' - 8"9' - 8" 3' - 8" 19' - 0" 10' - 4"13' - 4" 10' - 0" 19' - 4"8" 7' - 0" 8" 8" 8"3' - 8" 8"5' - 4" 8" 16' - 9 3/4" 13' - 6 1/4" 16' - 8" 14' - 4" 8" 4' - 4" 9' - 0" 11' - 4" 8" 8" 15' - 4" 8" 13' - 10 3/4" 5' - 1 1/4"48"x48"x12" CONC. PAD 36"x36"x12" CONC. PAD 16"x8" CONCRETE UNDERSLAB FOOTING 8' - 8"19' - 4" 8"4' - 0" SLOPE 2" TO DOOR 16"x8" THICKENED SLAB 6' - 0" 4' - 0" 2' - 0"8" 7' - 4" 12' - 0" 8"8" 11' - 9 3/4" 1' - 4" 15' - 2 1/4" 8"3' - 0" 8" 21' - 8" 4' - 8" 5' - 4" 8" 4' - 0"16"x8" CONCRETE UNDERSLAB FOOTING DROP T.O.W. TO BELOW GARAGE SLAB 1' - 4"1' - 8" 8" 4' - 0" 8" 1' - 8"1' - 4"3' - 0"25' - 4" 15' - 8" 19' - 4" 29' - 8" 4' - 0"90' - 0"9' - 0" 8" 12' - 4" 8" 17' - 4" 2' - 0"3' - 2" 8"2' - 6"5' - 6"5' - 6" 2' - 4 3/4" 9' - 3" DROP T.O.W. AT O.H.D. 1' - 1" 9' - 3" DROP T.O.W. AT O.H.D. 3' - 4 1/4" 8' - 9 1/2" 3' - 6 1/2" 8"1' - 4" 3' - 0" 24' - 8" 13' - 0" 2' - 0"13' - 4"8"4' - 4"8" 4' - 0"8" 6' - 4" CONCRETE PILASTERS BELOW STEPS CONCRETE PILASTERS BELOW STEPS 3' - 6"5' - 8 1/2" 6' - 7"7' - 8 3/4"2' - 1" 4' - 3 1/2"8" 22' - 0" 17' - 4" 8"4' - 4"4' - 4" 8" 9' - 0" 8" 15' - 4" 8"11' - 0" 2' - 4" 20' - 4" 10' - 4"9' - 8" 8' - 8" 12' - 0" 4"1' - 8"7' - 8" 3' - 4"44' - 8" 29' - 0" 11' - 0" 21' - 3 1/2" DROP T.O.W. 4' - 8" 18' - 8 1/2" 88' - 0"44' - 0"2' - 8" DROP T.O.W. 4' - 8" 9' - 2" DROP T.O.W. 4' - 8" 8' - 6" 8" 5' - 4" 8" 12' - 4" 10' - 4" 25' - 4" 3' - 4" 6' - 8" 4' - 0"25' - 11 1/2" 1' - 4" 12' - 10 3/4" 4' - 11" 1' - 4" 7' - 2 3/4"8' - 10"16"x8" CONCRETE UNDERSLAB FOOTING 13' - 2 1/4" 8' - 0 1/4" 16' - 2 3/4" 5' - 2 3/4"21' - 0 3/4"FLOOR DRAIN AS REQUIRED FOR CONDENSATE 3' - 4"1' - 4"4' - 6 1/2" 1' - 4" 44' - 0"36"x36"x12" CONC. PAD 16"x8" CONCRETE UNDERSLAB FOOTING1' - 10 1/4"1' - 5"1' - 10"2' - 6 5/8"11' - 10 1/4" 36"x36"x12" CONC. PAD 36"x36"x12" CONC. PAD FLOOR DRAIN AS REQUIRED FOR STEAM UNIT 2' - 0"6' - 8" 2' - 7 1/4" THICKENED SLAB BELOW FIREPLACE CUSTOMER:PROJECT NAME:LOCATION:DRAWING TITLE: DRAWN BY:Copyright © 2020 Wedgewood Building Co. LLC. Wedgewood Building Co., LLC32 First Street NECarmel, IN 46032317.669.6300www.wedgewoodbc.com9/16/2020 1:14:00 PM S1THE DUSING RESIDENCE411 1st Ave. Southeast, Carmel, INFOUNDATION PLAN ABL1/4" = 1'-0"5 FOUNDATION PLAN Rev.No. Date DescriptionBy Andrew Lund at 1:15 pm, Sep 16, 2020 10/15/20