Loading...
HomeMy WebLinkAboutA00 - GENERAL INFORMATION8'-1 1/8"1'-0" 1'-4"8" MIN8" MIN2'-8"6 MIL VAPOR BARRIER OVER 4" GRANULAR FILL 2" RIGID INSULATION BATT INSULATION AT BAND BOARD AND KNEE WALL ANCHOR BOLT PRESSURE-TREATED 2x4 PLATE OVER SILL SEALER VENTED WEEP HOLE FLASHING PERIMETER DRAIN TILE WRAPPED IN FILTER FABRIC DRAINAGE FILL SLOPE GRADE AWAY FROM FOUNDATION 8" CMU FOUNDATION WITH MOISTURE BARRIER CONCRETE FOOTING WITH REINFORCING BAND BOARD 2x10 JOISTS AT 16" O.C. 3/4" T&G PLYWOOD SUBFLOOR 2x4 PLATE 1/2" EXTERIOR SHEATHING AIR-INFILTRATION BARRIER 1" AIR SPACE BRICK TIES AT 16" O.C. E/W BRICK VENEER 2x4'S AT 16" O.C. 3 1/2" BATT INSULATION VAPOR BARRIER 1/2" GYPSUM BOARD FINISH FLOORING BASEBOARD 5/8" GYPSUM BOARD CEILING DOUBLE TOP PLATE INSULATION BAFFLE R-38 BATT INSULATION 1/2" ROOF SHEATHING 30# ROOFING FELT FIBERGLASS SHINGLES ICE AND WATER MEMBRANE METAL DRIP EDGE GUTTER 2x6 SUB FASCIA 1x8 FASCIA 3/8" VENTILATED SOFFIT 1x4 TRIM 2x8 RAFTERS AT 16" O.C. DOUBLE TOP PLATE KNEE WALL - 2X4's AT 16" ON CENTER 12 4 CEDAR WATERTABLE FLASHING 1x6 TRIM CEMENTITIOUS SIDING TO BEST MATCH EXISTING (2) 2x12 HDR (2) 2x12 HDR SEE FLOOR PLANS AND WALL SECTION FOR TOP PLATE HEIGHTS SEE FLOOR PLANS FOR HEADER HEIGHTS KING AND JACK STUDS DOOR WDW C2020 SURROUNDINGSTHIS PLAN IS PROPERTY OFSURROUNDINGS.ANY UNAUTHORIZED USE ORREPRODUCTION OF THIS PLAN, INWHOLE OR IN PART ISPROHIBITED. BERNARD DESIGNWILL USE ALL LEGAL MEANSAVAILABLE TO PURSUE THEUNAUTHORIZED USE OF THISPLAN OR ANY DESIGN ELEMENTSCONTAINED THEREIN.Carlberg ResidenceFamily Room AdditionQueens Manor - Section 2 - Lot 1911066 Queens Way Circle Carmel, Indiana 46032Date 09.28.20 Indiana Design Centert200 S. Rangeline Road Suite 120A Carmel, Indiana46032Area Location Map NO SCALE Typical Wall Section SCALE: 1/2" = 1'-0" Description General Information Sheet Number A-00Typical Door and Window Framing SCALE: 1/4" = 1'-0" PROPOSED SQUARE FOOTAGE TABLE SFGARAGE 925 SFROOM ADDITION 604 LOT ACRES4.71 SF SF SECOND FLOOR FIRST FLOOR 2462 1878 SFBASEMENT (FINISHED AND UNFINISHED) 2270 GENERAL NOTES: THE BUILDER SHALL VERIFY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING WORK. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AND LOCAL CODES. WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE INTENT OF THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). SEE ADDITIONAL NOTES CALLED OUT ON OTHER SHEETS. BUILDING PERFORMANCE: HEAT LOSS CALCULATIONS SHALL COMPLY WITH THE REQUIREMENTS OF REGIONAL AND LOCAL CODES. ALL EXHAUST FANS TO BE VENTED DIRECTLY TO THE EXTERIOR. ALL PENETRATIONS OF THE BUILDING ENVELOPE SHALL BE SEALED WITH CAULK OR FOAM. 10/16/20