Loading...
HomeMy WebLinkAboutC600 Storm Sewer Plan and Profile-C6000cc O 0 U 2 I>3 O cn a� U) L C:> m U \2 d L0 co 0 U) It QoN CD(606 O U U (9 L L U) C C 1144�.7W9 EX.CURBINL18" INV18" INV T.P 5 d W TEN C=860.8y9 I ' I'VAR EX. CRBI INLET R.D.C.&U.E.&P.A.E. IES.I8"PVC=839.9 T.C..S.E&L.M.A.E.&B.MY.E 18" R.C.P. E INV=850.16 J 18" R.C.P. W INV=R50.06 EX. OUTLET CONTRO #638 I } VAR p,&U.E.&L. I T.C=853.76 / I 18" 13 � R.C.P. W I I wAY I INV=850.73 I I I I SEX EXISTING a W J Hzoz / 23 I I HAMLET BMP I I W 1 3 I \ I I I DRY III DETENTION I I A BASIN > w 2 YEAR=852.14 I I 0 44 I 24 / \ \ 10 YEAR=853.10 I I - \r \ TOP OF ANK=854.8 I 1 1 4 I P.W.P' 1 1 l�'s 9 I1 1' 1 I 125 d 43 61B I I 21 PAVEMENT WIDTH e \ rt1 1 � 1 1 _ / EX. MH. #,IG840 1 T.0-856.93 1 I 8" S.D.R. 35 P.V.0 N / INV =R4 I \ 1 8" S.D.R. 35 P.V.0 W \ ,NV. .V. RI 1 1 R" S.D.R. 35 P.V.0 S INV=845.63 1 / � 1 1 II 1 1 � � 1 1 1 50' W \ 1 1 gq 1 CULTIVATED 11 I FIELD \ 11 1 _ _ EX. CURB INLET w/ 2'SUMP #6 40 T.C=854.23 HOLE #641 15" R.C.P. E \ C=855.06 INV.=849.30 8" R.C.P. E 18" R.C.P. W 1 QV =848.80 INV.=849.20 \ i" R.C.P. ,TV=848.W 70 EX. MH. #JG839 I 1 \ T.C..V.0 9 8" S.D.R. 35 P.V.0 N INV =844.18 8" S.D.R. 35 P.V.0 E S INV =844.08 E WOODED 00 H � m 00 N cn H 870 860 850 840 SCALE: 1 "=40' HOR. 1 "=4' VERT. 26 42 r 1 I r I I I w 1 v' T.C.=854.76 L 27 5' R.C.P. W I I ¢ I 6' MP END SECTI N [NV.=851.06 I I EX. ENDS CTION # 550 c TO BE RE OV 15" R.C.P. E I 15" R.C.P. 15" R C.P. ✓� INV=850.97 I INV.-851.. W VAR. } w \ 52 41 & S.S.E. 6 AR. \ 64 R.D.E,& &L.M.A.E. 1 I \ IU B.L. B.L. of 1\� 1 _ I 1 O\ ^ oI O a CAI 0 A r r I C4 co m I o W I w pI�C i 40 29 30 31 D' izlP'��S,2�3 I I 28 1 - I I 1 � W 39 1 \ \\ I 12" 8553 I 412"CMP=855.94' o \ CZ 6, B� I o � —4T B.L.— I 1 \ �ITUJE— I I / 3� 1 8 8 I � 1 BLOCKOB'o (PRIVATE) / w 6' B� 8¢6 15.0' G 00 �II ;;rF ,, " ` G . MH. F. 193 L.F.12" R.C.P. (a 030"/o T.C.=RJ57.18 � 37 IGH2 I A T 858.10 0 17 B.L. 1T B B.i- 8" _ INV.=841.28 G TC-857.24' 1 1 I I 10" .R. 35 P.V.0 E W I IE N. & S.18" PVC=838.99' INV.=841.08 \ / —I &�U. EX. I ' �/2 /W I 1 E . DBL. CURB r36T #639 \ T.C.=854.07 _12" C.P. SE ' / 35 34 33 32 I s .. A. O 1 ICK 49.56 79' .Y. / &h j E W P. W E V R4 . LET 36 SETEI I 1 C=R54.04 12" R.C.P. S a a INV.=850.09 t2"R. � D.E.&U.E\ I `� o vA[z_ I 11 \ �5:5&L.M.A.E. I S.L.E. I \ 10'B.L. 10 .L. 0 5 0 5 w I HAMLET DRIVE / C) ILLJ \ wI / EX. CURB INLET #635 EX. MH. #JG838 D39 12" R.C.P. N P.W.P. _ E E INV=850.23 E E E E E _8" S.D.R. 35 P.V.0 W 3 3 °"'PI INV.=842.47 _2 OH_E 8" S.D.R. 35 P.V.0 N r M 7 �k z WU O N OWM'N Up}O Q 2 Q Q H z w� EXISTING GRADE r PROPOSED GRADE \ _ — 193 L.F. 0.30% 12" R.C.P. CLASS III 852.4 851 145 L.F. 0.25% 15" R.C.P. CLASS III 1.50 \ 51.86 8" S.D.R. 35 P.V.0 INV.=848.34 HYDRAULIC GRADE LINE 34 L.F. 0.2 15" R.C.P. UP INV.=i DOWN IN 870 860 850 i% LASS III 51.50 J.=851.41 840 N w + N N Q 870 860 [— PROPOSED GRADE EX. EMP CONC. END SECTION TO I IE REMOVED Ex. 15" R.C.P. EXISTING GRADE 850 i 850 ��121 L.F. 0.27% 15" R.C.P. CLASS III HYDRAULIC GRADE LINE UP INV.=851.41 DOWN INV.=851.38 840 SCALE: 1 "=40' HOR. 1 "=4' VERT. CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. DENOTES FULL DEPTH GRANULAR BACKFILL (SEE DETAIL 10-31 ON SHEET C802) z z > U Q F W GRA1'111C SCALE Q 50' 0 25' 50' 14 > ( ilk FFFT ) 1"=50FT � W o q ST0EPPF�'•,. No. 19358 ate'; STATE OF ��' •. �NDI ANP °N 'S/ANAL LNG` "40"n1nno1,``% W 0 O Q W Q H d NOTES: A z ALL STORM STRUCTURES TO RECEIVE SOLID LID o z w CASTINGS ARE TO BE CONSTRUCTED TO PROVIDE ONE 4" RISER RING NO MORE, NO LESS TO ACHIEVE PLAN RIM a GRADE. 3 z a o Q Q�WP H ALL YARD INLETS ARE TO BE CONSTRUCTED AT A > °a TOLERANCE OF +0.00' TO -0.20' OF PLAN GRADE. o C4 Cj ALL STORM SEWER CASTINGS SHALL BE LABELED Z "DUMP NO WASTE -DRAINS TO WATERWAY" ALL SSD'S (SUBSURFACE DRAINS) WILL NEED TO BE DOUBLE WALL SMOOTH BORE PERFORATED (HDPE) PIPE.Ln H DEBRIS GUARDS ARE TO BE INSTALLED ON ALL OPEN O �� N Cj 01 ENDED INLETS. M � CR CR FOR STORM STRUCTURE SIZING AND CASTING TABLE SEE J Z Zco DETAIL D-18 ON SHEET C802.z Cl s ALL STORM SEWERS WITHIN PUBLIC RIGHT-OF-WAY , a SHALL BE RCP CLASS III. a o M z ` °' FOR INSTALLATION OF STORM UNDER CITY STREETS AND W L U Ln rL COVER REQUIREMENTS, SEE SHEET No. C802 ON THE 00 a TRENCH DETAIL. O THE MINIMUM COVER FROM THE TOP OF THE INSTALLED a PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL p" BE THE PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE • SUBGRADE) PLUS 1-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM ' THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. V STORM SEWER NOTE THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OR CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS AND 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS -BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS -BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. STORM SYSTEM STORM SEWERS FOR THIS DEVELOPMENT WILL BE PRIVATE. Know what's below. Call before you do *errr * " rr*� ,%pV1 y. Indiana Underground Plant Protection Service Q �-+ z H � O z a � O O � N F4 Gt V 1 O �Tl W U DRAWN BY: ADG CHECKED BY: BAH SHEET NO. C600 S & A JOB NO. 60160HAM-S2