Loading...
HomeMy WebLinkAboutC800 Details-C800CLAY TOWNSHIP REGIONAL WASTE DISTRICT SUMMARY OF LATERAL INSTALLATION REQUIREMENTS 1. All houses, buildings, etc, shall connect to the District's sanitary sewer system within 90 days of notice providing a sewer is within 300 feet for Hamilton County or 100 feet for Boone County of the properly line as dented through Indiana Code (IC 13-26-5-2). Only one building may conned to the sewer main per lateral unless otherwise approved by the District. 2. No foundation, Sump, Downspouts or other storm water drains shall be interconnected to District's sanilary sewer as addressed through our ill Ordinance 12.08,08 and ill Policy found on our website at www c€rwd.org. 3. The existing sewer line from the building to the septic lank may only be used if it is located under a building addition, patio, porch or paved driveway. Air test is required to show if acceptable for re -use. The property owner shall bear the cost of all testing. The District inspector must he onsile for the duration of the air test. 4. The owner or contractor shall notify the District prior to covering the installed lalerai so that the District can make an inspection to determine compliance with the District's sewer use ordinance. Lateral stubs shall remain capped until an Inspector is on site. Final connection shall only be made under direct supervision of a CTRWD inspector. Such notification shall be made 24 hours prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on sle for scheduled inspection, or fails to cancel inspection, an additional fee of $100.00 will be due. This must be paid prior to the time of the fellow up inspection. 5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public sewer, a septic lank "...shall be abandoned (pumped clean) and filled completely with earthen material or stone in a safe and sanitary manner," Please contact the appropriate County Board of Health for further information and to notify the department of the abandonment. 6. Acceptable Pipe Materials: PVC PIPE: SDR 35 or SDR 26, ASTM D3034, SIX INCH PIPE PVC PRESSURE RATED PIPE: SDR 21, ASTM D2241, SIX INCH PIPE RESTRAINED JOINT PVC PIPE (DIRECTIONAL DRILL): Yelomine SRD 21, ASTM D2241, SIX INCH PIPE (use on€y per approval of the District Engineer) GASKETFDJOINTS:ASTM D32T2 GASKETS: ASTM F477 FITTINGS: SDR 26 or better (NO femco's allowed) DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS PRIVATE GRINDER PUMPS ACCEPTABLE PIPE MATERIAL: IF CONNECTING INTO A LOW PRESSURE FORCE MAIN- - CTRWD must be contacted for explanation of allowable pumps and pump requirements -1,25" HDPE DR11 IPS (TYP-) connections are lobe made with Compression Fittings (Polypropylene or Brass), Mechanical Fillings or ETectrofusion ALL PUMP CONNECTIONS -Pumps located more than S perpendicular to or run longitudinally along the building for more than 3' shall haves cleanout installed and the pipe shall be tray itioned to 6" SDR 35 pipe forconnedion into the pump station, CLEAN OUTS ARE TO BE LOCATED NO MORE THAN THREE FEET FROM THE FOUNDATION AND FOR GRAVITY LATERALS NO MORE THAN 100 FEET APART (please see Clean Out Details Type 2 and Type 3 for multiple cleanout installation requirements). CLEAN OUT CAP REQUIREMENTS: 6" PVC Threaded Caps 7, Bedding: Use Number 8 crushed stone or Number B fractured face aggregate Number 8 stone backfili material Is to be placed from 6 inches below to 12 inches above the pipe The trench should be a minimum of 18 inches wide (six inches on both sides of the pipe) 8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting SDR 21 and ASTM D2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the District and the District's engineer Prior to Installation. 9. Where a transition is made between SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed mechanical coupling shall be used. 10. Laterals shall lan inate wrlhiri 3 €eel of the building unless the conditions in hem #3 above are met. No glued pipe shall be installed outside eb'ee feet of building foundation walls. 11. Additional information on District standards and specifications may be obtained from the District's office during business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site at htipalwww.clrwd.org. Clay Township Regional Waste District 10701 North College Suite A. Indianapolis, Indiana 46280 Phone: 844-9200 Fax: B44-9203 12. Septic effluent shall not be pumped out into the santary sewer system. 13. The District shall inspect ALL laterals. Please call the District office at 644.9200 24 hours prior is time of inspection 14. Contractors shall lay 14 gauge -solid wire the entire length of the lateral. Wire is to be placed on lop of the lateral. The District Inspector wit verify placement of the wire. After inspection, bedding is to be placed on top. 15. All exteriors structures and piping are subject to be tested andlor televised upon the Districts discretion. Examples of structures that may be included are manholes, grit interceptors, pump pits, grease interceptors, etc. Testing requirements are to verify that all structures are watertight and that they conform to the Districts III Policy. 16. Call before you dig! iUPPS- Indiana Bii, 48 hours prior to digging. Lateral-rev.03-26-D9rh �-C -3-3 -3 L=J 1:7:1 �n z �t C7 3 -3 `a d r � a w .1Z w i C- o y ey rig rHrcr -Ate d 55 O O 00 U 3 5 D 17: My My C) a) CD U 2E d (D00 to NLf) Q Ln N O U) =oo O N CD U U L72: 2: Notes: than 12" of adjustment rings above 12' a borrel section must be added PRECAST CONCRETE ADJUSTING RING OR FLANGE OF CASTING 30 1/2" OUTSIDE DIAMETER KENT SEAL �9UTYL RUBBER COATING WITH PLASTIC WRAP 24" INSIDE DIAMETER COVER 7 JOINT DETAIL 1/4" (TYPICAL 2"-12" 1/4" (TYPICAL)-m-I a 1/2" RISER RING THICKNESS 30 1/8" OUTSIDE DIAMETER - 4" - 12' OUTSIDE DIAMETER 34" OR 35' 1 1/2" RAISED LETTERING (RECESSED FLUSH) 1 5/8" (4) 1/2-13 X 2" HEX HD SS CAP }--^}-- [41mm] SCREWS & WASHERS 1 � 1/2"-13 BOLT \ STEEL WASHER & RUBBER WASHER = (TYP 4 PLACES) 1 1/2" 5/8" 1� [38mm] [16mm] BOLT DETAIL _ 223/4" CIA [578mm] 1 11/16" [43mm] / COVER SECTION i 23" CIA [584mm] 1 3/4" -1/4" (6mm) `m - [44mmJ NEOPRENE GASKET --- --. 7" [i 78mm] T- ' 20 13/16" DIA [529mm] 34" DIA [864mm] FRAME SECTION 2 1/4" 737mm) [57mm] �[11mm] [35mm] I [25mm] PiCKHOLE DETAIL PLAN VIEW WATERTITE ASSEMBLY PRODUCT NO, 00102306 CATALOG NO. 1020APT 1022Z1PT PRODUCT NUMBERS 102312 102163 EST. WT. COVER WT. 114 LBS, 521,9 FRAME WT. 145 L55 (i UNIT WT. 259 LBS 117kg MAT'L SPEC. COVER. - GRAY IRON ASTM A48 CL35B FRAME - GRAY IRON ASTM A48 CL35B LOAD RATING HEAVY DUTY NOTE: � SEPARATION BETWEEN W1t: FITTING: A OPPOSITE SIDE LATERALS 1)) V MINIMUM BELL TO BELL 1RACElt YIRE 2) BELL TO SPIGOT MAY BE ADJACENT (TYPICAL ALL PROPERTY, RIGHT-OF-WAY �I 11' LATERALS) OR EASEMENT UNE i FOR SEPARATION SEE NOTE ONE PIECE TEE -WEE I i REQUIRED -. ' __ RIGHT-OF-WAY, PROPERTY - --- -- OR EASEMENT UNE ! - - TRACER WIRE 6• SDR 35 PIPE MAIN SEWER UNE * BE ONNO STONNE�W I EARTH. CCOMPPACTI� IS CRITICAL UNDER ALL JOINTS AND FITTINGS. IF PROPER COMPACTION CANNOT BE ACHIEVED, THEN PUCE A MINIMUM OF 6. OF 3500 PSI, NOTE: 28 DAY COMPRESSIVE STRENGTH CONCRETE ALL FITTINGS SHALL BE SDR 26. PLAN VIEW AROUND THE PIPE TO BEAR ON STABLE GROUND (PER ENGINEER). PAINTED GREEN 2• X 4• LWTH ROD OR T POST (DETECTABLE BY METAL DETECTOR, S ABOVE GRADE) DEPTH TO LATERAL TO A MINIMUM OF 6. OF STONE OVER SHOWN ON MARKER (TYPICAL THE CONCRETE CAPPED ME SHALL BE (TYPICAL ALL LITERALS) PLACED PRIOR TO BACKFlWNG. 1Y RIGHT-OF-WAY 225' OR 45' FINISHED GRADE OR EASEMENT UNE �\ TRACER LWRE (TYPICAL ALL LATERALS) \ \ 22S OR �• 5' MINIMUM - 0, MAXIMUM (TYPICAL ALL LATERALS) ANGLE MUST BE BETWEEN CAP FOR `' 15• AND 45'. \ ANGLE MUST BE BETWEEN FUTURE CONNECTION I / 15' AND 45'. (TYPICAL ALL LATERALS) MINIMUM 4• CONCRETE CAP REQUIRED, _ NOT TO EXCEED BYOND FIRST PIPE 6•JOINMINIMUM• INIMUM FALL' PER FOOT OF IF A WYE IS 20 DEEP, T MAY NEED TO BE DEEPER FOR RE THEN } THEN CONCRETE CAP IS REWIRED AT TYPICAL ALL LATERALS) LONG BUILDING LATERALS OR FINISHED GRADES SLOPING AWAY THE ENGINEERS DISCRETION. MINIMUM CONCRETE STRENGTH OF 3500 PSI 28 FROMSEWER • DAY COMPRESSIVE SIREN111 NOT REWIRED FOR DUCTILE IRON TIE. SECTION \\\\\\��YYYOYIuuuuuRNpiuiiiriirrrrrp� NOTE BE P�\o A c�� AULATERALUN ISTURBBED INCH.. Gtsrfp�o MORE THAN 20' DEEP LESS THAN 20' DEEP No. NOTE: DEPTH OF SERNCE LATERAL SHALL BE MEASURED FROM 19300219 FINISHED GRADE TO THE TOP OFMAIN SEWER UNE STATE OF �141` PIPE REQUIREMENTS PER DEPTH ARE AS FO.OWS: O `(`V \ 3'-19' = SDR-35 20'-25' = SDR-26 /NOT ANP .. 26' OR GREATER = SDR-23.5 ALLTTG�\``\` SERVICE LATERAL DETAIL CLAY TOWNSHIP REGIONAL WASTE DISTRICT oaNA MaMur� 44bl SERVICE LATERAL DETAIL :cTRwD Schneider NORMAL AND DEEP CONNECTION REGIGNAe �V'+s Date 12/06/06 File T:\6E\6366\001\DWGS\DETAILS\IN-DTIS.DWG TRENCH BOX OR OTHER IOSHA ACCEPTABLE TRENCH SAFETY SYSTEM 1/2 D + 12" FOR PVC PIPE 1/2 D + 6" FOR DI 1/2 D SEE FIRST LAYER BEDDING TABLE BELOW /2 STONE AS REQUIRED BY ENGINEER FOR UNSTABLE SDIL CONDITIONS - DEPTH TO STABLE GROUND PER ENGINEER TRENCH WIDTH MAXIMUM 10 FEET AT TOP OF EXCAVATION TRENCH WIDTH SHALL NOT EXCEED BOX WIDTH BY MORE THAN 1.0 FOOT 0 FIRST LAYER BEDDING TABLE PIPE SIZE a TO 15' 1 18' & OVER BEDDING BELOW THE MINIMUM = 6' MINIMUM = 10" PIPE BARREL AND BELL tfJ ­3 L1 Ej L--L U] ?N3 ­3 CD d C CIO !;;d r=...� 0 i "CLEAN* BACKFILL MATERIAL FREE OF ROCKS, ETC. LARGER THAN 6" OR OTHER EXTRANEOUS MATERL. (COMPACT TO PREVENT SETTLEMENT), IN AREAS WITHIN 5' OF ROAD SURFACE, BACKFILL PER REQUIREMENTS OF IND€ANA DEPARTMENT OF TRANSPRTATION AND COMPACT FILL TO 95% MODIFIED PROCTOR DENSITY. NUMBER 8 CRUSHED STONE OR NUMBER 8 FRACTURED FACE AGGREGATE FILL MATERIAL IS 10 BE PLACED FROM 6 INCHES BELOW TO 12 INCHES ABOVE THE PIPE THE TRENCH SHOULD BE A MINIMUM OF 18 INCHES WOE, SHOVEL SLICED, HAND TAMPED AND WALKED IN. #B CRUSHED STONE SHOVEL SLICED. HAND TAMPED AND WALKED IN. (BELL HOLE EXCAVATED) SEWER AS PER CONSTRUCTION PLANS PIPE SIZE A B UP TO 16 3'-D 2'-6- 18' ANO GREATER I D + 24' D + 18' Y [5Tmm1 RKSFA LET11 FLUSH Wth StWACE � r CST �I cwlc,�At� pM13WOLE PER NF 9204-n Ta E I � 3/4•" � [1�rxn] T-SEAL GROOVE IN LPD SEAT FCR C(L-• fsi'ANT T-GASKET 1f11i6LE (60 W=H IEi 02797 T-SEAL w/ =QEALEl7 PtCKHOLE DETAIL SCALE 1;� 14aM � 3� S76 Al2ttn 01 �t " r1 7/8" E4#nrrt] T' [1] Ai°TC1-CM f4OLE flt"'WL SCALE 1: 2 FINISHED LATER MAIN I NOTE: WATER MAINS SHALL BE i LOCATED ON AN UNDISTURBED LEDGE. \ \\ .A" / d SANITARY SEWER 10• MINIMUM 10' MINIMUM WATER MAIN -JOINT SANITARY SEWER "A" JOINT FLOW --- IF "A" IS IF "B' IS THEN SANITARY SEWER PIPE SEGMENT SHALL BE 18" OR MORE 10' OR MORE NO SPECIAL PIPE MATERIAL OR GRADE REQUIREMENTS LESS THAN 18° LESS THAN 10' PVC (EITHER ASTM D 2241 (SDR 21) OR ANSI/AWWA C900 (DR 18) OR ANSI/AWWA C905 (DR 21) DR DUCTILE IRON (CLASS 51 MINIMUM) NOTE: SEPARATION DISTANCES FROM WATER SUPPLIES AND PIPE CLASSIFICATIONS SHALL CONFORM TO DISPOSAL INDIANA STATE BOARD OF HEALTH'S 'ON -SITE WATER SUPPLY AND WASTEWATER FOR PUBLIC AND COMMERCIAL ESTABLISHMENTS - BULLETIN S.E. 13" WELL/WATER SUPPLY & SEWER CROSSING DETAIL. -y S' [76mm7 1 E rs _ (2) NF-8204-A CONCEALED LIFTHOLES ' T-SE/.L 1 21/3r [42mrn] LID. puJs 3/az- [2wnj GA%(Er NOTE: ALL., DIMEN15 O Ns ARE SHOW IN R iQ-1 Y•1 AND [W�MCJ 11AT£"'2i &- ;Asr GRAY IRON ASTM A-46, MAss 353 FINI51£: NO PANT swa-1T: tlag 3/e' [SMktts ] T.? 7- [17flmrtl] 2" ['s'T' 'r 1l � I-- r '. _TF_ � I u ® LL t 3/4' [44+r1m] 31W [TOtten1] R= ALL nuavlsInNs sitlowx AW N x wai mci [Memel L: CAST MkY IR{g'f WIMI A-48. 0.4= 3SW Nff ?AB,IT LIMIT OF SUBGRADE FINAL BACKFILL SHALL BE PER NOTE 1. 6" MINIMUM OF TOPSOIL OR COMPACTED Ck� AGGREGATE #53 L _ PAVEMENT SECTION VARIES MINIMUM COVER SHALL BE PER NOTE 3. PIPE MATERIAL PER UTILITY BEDDING, HAUNCHING, HAVING JURISDICTION OVER TRENCH WIDTH, INITIAL INSTALLATION. BACKFILL MATERIALS, PLACEMENT, AND COMPACTION PER STANDARD PRACTICE OF UTILITY HAVING' r JURISDICITON OVER BC INSTALLAT101N. WATER & SEWER MAIN AND LATERAL TRENCH DETAIL FOR UTILITY INSTALLA TIONS WITHIN CITY R/W NOTES: NO SCALE 1. FINAL BACKFILL FOR UTILITY INSTALLATIONS WHERE I" IS 5' OR LESS SHAD_ BE B-BORROW FOR STRUCTURE BACKFILL MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL BE COMPACTED IN 6" MAXIMUM UFTS TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE MATERIAL PLACED. THE BACKFILL FOR THE TOP 6" OF THE EXCAVATION BELOW THE LIMIT OF SUBGRADE SHALL BE #53 STONE MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL BE COMPACTED TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE MATERIAL PLACED. IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE INSTALLATION HAS A MORE STRINGENT FINAL BACKFILL REQUIREMENT, THE MORE STRINGENT REQUIREMENT WILL GOVERN. CONTRACTOR SHALL PROVIDE A 3rd PARTY TESTING AGENCY TO PROVIDE COMPACTION TESTING AS NECESSARY. 2. THIS REQUIREMENT SHALL APPLY FOR ALL UTILITY INSTALLATIONS (INCLUDING BUT NOT LIMITED TO WATER MAINS, WATER SERVICE LATERALS, SANITARY MAINS, SANITARY SERVICE LATERALS, GAS PIPING, POWER, TELECOMM AND CAN CONDUITS OR DUCT BANK) WITHIN EXISTING AND PROPOSED CITY OF CARMEL R/W LIMITS. 3, FOR UTILITY INSTALLATIONS UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT OR FINAL GROUND ELEVATION TO THE TOP OF THE INSTALLED PIPE CONDUIT OR DUCT BANK SHALL BE NO LESS THAN 2.5 FEET. IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE INSTALLATION HAS A MORE STRINGENT COVER REQUIREMENT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. 4. IF EXISTING SUBGRADE HAS BEEN LIME STABIUZED, BACKFILL WITH B-BORROW TO BOTTOM OF EXISTING SUBGRADE AND FILL TO THE LIMIT OF TREATED SUBGRADE VWTH COMPACTED AGGREGATE, NO 53. CITY OF CARVEL STANDARDS STANDARD DRAWING WATER & SEWER MAIN AND LATERAL TRENCH DETAIL FOR UTILITY INSTALLATIONS WITHIN CITY R W 10-32 7, z z o W cri O U U H W o� Q W u> c4 M Q 0 `\\\111111111f//// STOEPPFz'�.,���' Q�0,\STEq .Fpti�., No. 19358 -0 ` STATE OF Q /IVDIANA �cv```, rl O Q w w H w Z I� Z T � V 1 I 4 O � � z O W � � W �O H yr--�W f� W DRAWN BY: CHECKED BY: ADG BAH SHEET NO. C800 S & A JOB NO. 60160HAM-S2