HomeMy WebLinkAboutFiling Exemption - Le PeepFrom: "Callahan, Sean" <SCallahan@dhs.IN.gov>
Date: Monday, August 31, 2020 at 11:52 AM
To: James Stutzman <jrs@pedcor.net>
Subject: RE: FILING EXEMPTION - SECOND REQUEST: LA PEEP - CARMEL
Mr. Stutzman,
Based on the information provided and the attached drawings, this project is currently EXEMPT
from filing with the State of Indiana DHS Plan Review section in accordance with 675 IAC 12-6-
4.
675 IAC 12-6-4 Exemptions from design release requirement
Authority: IC 22-13-2-13
Affected: IC 4-21.5; IC 12-13-4-3; IC 22-15-3
Sec. 4. (a) Design releases are necessary for construction on all Class 1 structures, except the following:
…
(b) Design releases are necessary for the remodeling or altering of all Class 1 structures, except
work limited to one (1) or more of the following:
(1) Any of the buildings or structures the new construction of which is exempted by
subsection (a).
(2) Plumbing work as follows:
(A) Replacement of piping, valves, or fixtures, provided that the replacement
does not involve relocation of fixtures.
(B) Installation of plumbing fixtures, provided that the drainage fixture unit
count does not exceed five (5).
(C) Replacement of water heaters with a similar type and capacity in the same
location.
(D) Installation of water heaters with a capacity of one hundred (100) gallons or
less.
(3) Electrical work as follows:
(A) Replacement in the same location of electrical equipment or devices of a
similar type and rating, including an increase in current capacity in
nonhazardous areas where there is no change in voltage or phases.
(B) Portable or temporary equipment and devices energized by means of cord
and plug.
(C) Temporary installation of wiring and devices.
(D) Installation of branch circuits not exceeding the capacity of the electrical
distribution system within the existing building.
(E) Low-energy power, control, and signal circuits of Classes II and III as
defined in the Indiana Electrical Code except circuits for fire detection or fire alarm
systems.
(F) Electrical wiring, apparatus, or equipment installed by a public or private
utility in the exercise of its function as a serving utility:
(i) for the generation, transmission, distribution, or metering of
electrical energy; or
(ii) in the operation of signals or the transmission of intelligence.
(G) Except for fire detection or fire alarm systems, electrical wiring, devices,
appliances, apparatus, or equipment:
(i) operating at less than twenty-five (25) volts; and
(ii) not capable of supplying more than fifty (50) watts of energy.
(4) Mechanical work as follows:
(A) Installation of any portable heating, ventilating, and air conditioning
appliance or equipment.
(B) Replacement of mechanical appliances and equipment with a similar type
and rating in the same location.
(C) Installation of any of the following:
(i) A heating system having an output not in excess of four hundred
thousand (400,000) British thermal units per hour.
(ii) A cooling system having an output not greater than fifteen (15) tons
(one hundred eighty thousand (180,000)) British thermal units per hour).
(iii) A combination of the two (2) having an air-handling capacity not
in excess of nine thousand (9,000) cubic feet per minute.
(D) Installation of heating or cooling equipment to be used for commercial
processing work or activities where comfort of personnel is not of primary concern.
(5) Miscellaneous work as follows:
(A) Painting, papering, and replacement of coverings on:
(i) walls;
(ii) ceilings;
(iii) roofs; or
(iv) floors; and similar finish work, including replacement or reglazing
of glass.
(B) Cases, counters, and partitions not over six (6) feet in height.
(C) Penetrations of nonfire-rated exterior walls where the width of the opening:
(i) does not exceed six (6) feet; and
(ii) is not for a required exit.
(D) Installation of one (1) or more nonload-bearing partitions not to exceed a
total of one hundred (100) lineal feet in length provided it is not part of a
corridor or a partition that is required to be of fire -resistive construction.
(6) Fire sprinkler systems as follows:
(A) Replacement of components of existing wet fire sprinkler systems of light
hazard or ordinary hazard classification as defined in 675 IAC 13, including:
(i) replacement of sprinkler heads;
(ii) replacement of equipment; or
(B) Alteration of existing light hazard or ordinary hazard fire sprinkler systems,
including:
(i) the addition or alteration of up to an aggregate of twenty (20)
sprinkler heads in a wet pipe system for light or ordinary hazard design;
(ii) conversion of a dry type system to a wet or antifreeze type system
not exceeding ten (10) sprinkler heads; or
(iii) conversion of a wet or antifreeze type system not exceeding ten
(10) sprinkler heads to a dry type system.
You may still be required to submit to local jurisdictions.
NOTIFICATION: Starting July 1, 2020, Indiana Code requires all applications to be filed electronically,
unless it imposes an undue hardship.
Please visit dhs.in.gov/3658.htm to file your project online. Email planreview@dhs.in.gov or
call 317.232.6422 for any filing questions.
Sean Callahan PE | Plan Review Assistant Section Chief
Division of Fire and Building Safety| Plan Review Branch
Indiana Department of Homeland Security
302 West Washington Street, Room E-245
Indianapolis, IN 46204
Tel: (317) 232-6422
Email: SCallahan@dhs.in.gov
Web: http://www.in.gov/dhs/3658.htm
From: Plan Review <planreview@dhs.in.gov>
Sent: Monday, August 31, 2020 8:18 AM
To: Callahan, Sean <SCallahan@dhs.IN.gov>
Subject: FW: FILING EXEMPTION - SECOND REQUEST: LA PEEP - CARMEL
Importance: High
Exemption request
Rex Mays CCRI CCBI CPE/ Deputy Director
Division of Fire and Building Services/Plan Review Branch
Indiana Department of Homeland Security
302 West Washinton Street, RM E-245
Indianapolis, Indiana 46204
Tel: (317) 232-1408
Email: rmays@dhs.in.gov
Web: https://www.in.gov/dhs/3658.htm
NOTIFICATION: Starting July 1, 2020, Indiana Code requires all applications to be filed electronically,
unless it imposes an undue hardship.
Please visit dhs.in.gov/3658.htm to file your project online. Email planreview@dhs.in.gov or
call 317.232.6422 for any filing questions.
From: Jim Stutzman <jrs@pedcor.net>
Sent: Monday, August 31, 2020 8:15 AM
To: Plan Review <planreview@dhs.in.gov>
Cc: Jim Stutzman <jrs@pedcor.net>
Subject: FILING EXEMPTION - SECOND REQUEST: LA PEEP - CARMEL
Importance: High
**** This is an EXTERNAL email. Exercise caution. DO NOT open attachments or click
links from unknown senders or unexpected email. ****
Gentlemen: The following submittal was made to IDHS on 08.24.20 as a request for filing
exemption. This project is on-hold awaiting your reply. Could you please revisit this request and let me
know if the filing exemption is acceptable?
Thanks very much.
James Robert Stutzman, AIA, CSI, NCARB, RID
Vice President; Senior Principal Architect
PEDCOR DESIGN GROUP, LLC
355 City Center Drive
Carmel, Indiana 46032
From: James Stutzman <jrs@pedcor.net>
Date: Monday, August 24, 2020 at 1:48 PM
To: "planreview@dhs.in.gov" <planreview@dhs.in.gov>
Cc: Jim Blanchard <jblanchard@carmel.in.gov>, Jodi Harder <joharder@pedcor.net>, James
Stutzman <jrs@pedcor.net>
Subject: LA PEEP - CARMEL
Plan Review Branch
IDHS / Division of Fire and Building Safety
302 West Washington Street, Room E245
Indianapolis, Indiana 46204
Re: EXEMPTION FROM STATE FILING REQUEST
Project: LA PEEP - CARMEL
Suite 109
200 South Rangeline Road
Carmel, Indiana 46032
To IDHS Plan Review:
This letter is to request an Exemption from State Filing based on 675 IAC 12-6-4 and allow direct
permitting through the City of Carmel.
The attached drawings represent a tenant remodeling project on the ground floor level of the Indiana
Design Center on Rangeline Road in Carmel, Indiana.
The tenant, LA PEEP, is a Group A-2 Occupancy (Restaurant); Type II-B Construction and occupying
2,634 square feet. The initial tenant build-out for this space was BLUE MOON CAFÉ. A CDR under IDHS
Project number 323831 was issued on 02.16.07. Blue Moon has been in operation since that time. The
Occupant count remains the same at 175.
The new tenant LA PEEP – CARMEL wishes to operate a similar restaurant with only minor interior
remodeling consisting of partial removal of non-load-bearing walls, new and relocated store fixtures and
relocation of some light fixtures and receptacles on existing branch circuits.
The Project is of a minor scope of work and involves no structural or mechanical modifications. Electrical
modifications include only relocation of some existing light fixtures and some duplex outlets on existing
branch circuits. Four (4) new duplex outlets are to be added. No new electrical loading will be introduced
and no new circuits are necessary.
There is no change in area, occupancy or life safety paths or alarm system.
Therefore, I am requesting approval for direct filing of construction documents by the Contractor with the
Carmel Building Department for local permitting. As always, I and my staff of architects at Pedcor Design
Group will be providing construction observation during the construction work and will report to the Owner
any observed deficiencies or variations in the work as represented in the documents submitted for
permits.
If you have any questions, please feel free to contact me at any time.
Sincerely,
Disclaimer: This email and any files transmitted with it are confidential and intended solely for the
use of the individual or entity to whom they are addressed. If you have received this email in error
please notify the system manager. Please note that any views or opinions presented in this email
are solely those of the author and do not necessarily represent those of the company. If you are not
the named addressee you should not disseminate, distribute or copy this e-mail. Finally, the
recipient should check this email and any attachments for the presences of viruses. The company
accepts no liability for any damage caused by any virus transmitted by this email.