Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A1.2 - CEILING_ELECTRICAL PLANS
Project Number: Sheet Title: Issue Date: Sheet Number: Project:CARMEL, INDIANA By: Architect: Architecture / Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone)46032LE PEEP - CARMELDrawn By Checked ByPrint Date Revisions: 8/18/20 State Release Plans COPYRIGHT & OWNERSHIP OF DOCUMENTS 200 SOUTH RANGE LINE ROADINDIANA DESIGN CENTERSUITE 109A1.2 CEILING/ ELECTRICAL PLANS Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 1 A E G M 11 5 8/18/20 CONSTRUCTION DOCUMENTS 8/18/20 MC TJ THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPY RIGHT 2020 JAMES R. STUTZMAN, AIA, Carmel, Indiana. PLAN NO RTH KEY PLAN SCALE: N.T.S. N N J 9'-0" 14'-0" OPEN OPEN OPEN 9'-6" 9'-6" OPEN 14'-0" 9'-6" CP2 CP1 CP1 CP1 CP1 CP6 CP3 CP6 CP10 CP11 CP4 CP5 CP4 CP5 CP12 CP3 CP6 CP7 CP9 CP8 A NL B B B UU U U DN UP A A B B B B C C C C DR A A E E E E E E E ER G G G G F F F F F F F F H H H I ER ER ER ER ER ER ER ER ER ER TYP RR F220 220 220 220 220 220 EP1 EP2 EP3 +48" D KITCHEN 103 DINING 101 +42" +42" +42" GFI +48" +48" DN UP SUITE 109 2,634 SF DISHES 104 DINING 105 PATIO +42" N +42" N +42" N +42" N N +36" N USB +36" N USB+36"NUSB+36"NUSBN N GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. 5. 6. 4. 3. 2. 1. DUPLEX WALL OUTLET. 220V CIRCUIT OUTLET. 220 ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +44" HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. FLOOR MOUNTED FLUSH MOUNT JUNCTION BOX FOR HARDWIRE CONNECTION. J ELECTRICAL/DATA PLAN NOTES: PROVIDE NEW POWER OUTLETS SHOWN WITH AN 'N'. TIE NEW ELECTRICAL INTO EXISTING SUITE 109 ELECTRICAL PANEL. EP1 N DENOTES NEW OUTLET LOCATION. USB 115/60/1 NEMA-5-15R OUTLET. DUPLEX OUTLET WITH TWO USB PORTS. OUTLET TO BE 220 VOLT 30 AMP PLUG RECEPTACLE.EP2 PROVIDE 110 VOLT POWER SUPPLY AND FINAL HOOK-UP FOR TENANT SUPPLIED DISHWASHER.EP3 WALL JUNCTION BOX. CEILING HEIGHT IS INDICATED BY BENCHMARK ON THE PLAN. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. GENERAL CEILING NOTES: CEILING PLAN NOTES: LOCATE NEW SMOKE DETECTORS DUE TO NEW LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. CP2 CP6 EXISTING DRYWALL SOFFIT TO BE PAINTED P3. SEE LIGHT FIXTURE SCHEDULE FOR NEW LIGHT FIXTURES. 5. 6. 7. 4. 1. 2. 3. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. RELOCATE TRACK LIGHT "DR" THAT WAS REMOVED DURING DEMOLITION.CP7 RELOCATE BANK OF LIGHT SWITCHES TO THIS LOCATION.CP9 CP1 DRY FOG OPEN CEILING WITH NEW PAINT COLOR P4. CP3 NEW DRYWALL CEILING CLOUD TO BE 3-5/8" METAL STUDS W/ 5/8" GYPSUM WALL BOARD 6" EDGE. SUSPEND FROM STRUCTURE WITH THREADED ROD. FINISH UNDERSIDE AND EDGE OF CLOUD WITH WD2 STAINED WOOD PANELS. CP4 EXISTING SUSPENDED CEILING GRID TO REMAIN. REPLACE CEILING TILES WITH NEW ARMSTRON, 2'X4' GEORGIAN 793 SQUARE LAY-IN TILES. CP5 EXISTING TROFFER LIGHT FIXTURES TO REMAIN. CLEAN AND RELAMP FIXTURES. RELOCATE HIGH BAY LIGHT FIXTURES "ER" THAT WERE REMOVED DURING DEMOLITION.CP8 RECONFIGURE HVAC DUCT WORK AS NEEDED FOR NEW COUNTER LAYOUT.CP10 RECONFIGURE FIRE SPRINKLERS AS NEEDED FOR NEW CEILING CLOUD LAYOUT.CP11 PROVIDE NEW ELECTRIC HEATERS. SEE LIGHT FIXTURE PLAN FOR SPECS. CP12 PROVIDE NEW AWNING FABRIC WITH GRAPHIC LOGOS ON EXISTING FRAME. J SYMBOL TYPE A LIGHT FIXTURE SCHEDULE PENDANT FIXTURE MODEL BY OWNER. WATTAGEDESCRIPTION MOUNTING HEIGHT NOTES X W B 4" RECESSED DOWNLIGHT LITHONIA LIGHTING, LDN4 W/LENSE, 3000K, 750 LUMENS, DOWNLIGHT, CLEAR, SEMI-SPECULAR.8.6W X'-X" CEILING C PENDANT FIXTURE BY OWNER. X W X'-X" DR RELOCATED TRACK LIGHT PROVIDE NEW TRACK AND LIGHT FIXTURES. 14W CEILING E HIGH BAY FIXTURE EXISTING IMPACT ARCHITECTURAL LIGHTING, P3416-PFR-242-BA-FROST/FLAT FROST-UNIVOLT, W/ (2) 42W CFTR TRIPLE TUBE LAMPS TO REMAIN. RETROFIT EXISTING FIXTURES WITH LED LAMPS, 3000K. 20W 12'-0" TO BOTTOM F 2' X 4' TROFFER EXISTING MERCURY LIGHTING, LENS TROFFER, 35E-432-OCT-9A-ELB-UNI, W/ (4) 32W T8 LAMPS TO REMAIN. 128W CEILING G CEILING FAN EXISTING EMERSON HF956BS, 56" BRUSHED STEEL W/ CFDRX-BS DOWNROD TO REMAIN. 98W 12'-0" TO BOTTOM EXIT SIGN EXISTING CEILING MOUNTED EXIT LIGHT W/DIRECTION INDICATION DUAL-LITE TO REMAIN. EMERGENCY LIGHT EXISTING EMERGENCY BATTERY BACK-UP LIGHT FIXTURE. H TRACK LIGHT LAMPS TO BE LED, 3000K.X W 10'-0" I JUNCTION BOX EXISTING JUNCTION BOX FOR DECORATIVE CHANDELIER.X W DECK ER RELOCATED HIGH BAY FIXTURE EXISTING IMPACT ARCHITECTURAL LIGHTING, P3416-PFR-242-BA-FROST/FLAT FROST-UNIVOLT, W/ (2) 42W CFTR TRIPLE TUBE LAMPS TO REMAIN. RETROFIT EXISTING FIXTURES WITH LED LAMPS, 3000K. 20W 12'-0" TO BOTTOM, ABOVE FAN INSTALLED BY EC. INSTALLED BY EC. PROVIDE NEW TRACK AND LIGHT FIXTURES. LAMPS TO BE LED, 3000K. SCALE: 1/8" = 1'-0" 1 REFLECTED CEILING PLAN A1.2 SCALE: 1/8" = 1'-0" 2 ELECTRICAL PLAN A1.2 11 L 10 9 M K L 11 10 9 MK 10/19/20