HomeMy WebLinkAboutLandscape Plan stamped approved - final - 10-19-20600CALC CORNER SET X IN WALK ON LINE
EXISTING TREE, 18"
EXISTING TREE, 12"
EXISTING TREE, 18"
EXISTING TREE, 18"
EXISTING TREE, 18"
EXISTING
TREE, 18"
EXISTING
TREE, 12"
EXISTING TREE, 36"
EXISTING TREE, 24"
EXISTING TREE, 12"
EXISTING TREE, 24"
EXISTING TREE, 8"
EXISTING TREE, 18"
EXISTING TREE, 15"
REPAIR TURF FOR
IRRIGATION
ROUTING AS
NECESSARY
SOD REPAIR AS
NECESSARY
ALONG NEW
WALKWAY
PROTECT PEDESTRIAN SIGNAL POLE, REFER TO M.O.T. PLANS, REFER TO C-SERIES DRAWINGS
PROTECT SIGNAL LIGHT POLE, REFER TO C-SERIES DRAWINGS
SALVAGE ELEPHANT AND STORE FOR OWNER
SALVAGE BENCHES AND TRASH CANS,
STORE FOR OWNER
SALVAGE BENCHES AND TRASH CANS, STORE FOR OWNER
SALVAGE BENCHES AND TRASH CANS, STORE FOR OWNER
SALVAGE BIKE RACKS, BENCHES AND TRASH CANS, STORE FOR OWNER
SALVAGE DUMPSTER,
PROVIDE TO OWNER
SALVAGE SCULPTURE,
USE PER PLAN
SALVAGE SCULPTURE, USE PER PLAN
SALVAGE SHRUBS AND
PERENNIALS FROM OVAL
GARDEN, CONTRACTOR TO
STORE AND MAINTAIN ON
SITE
EXISTING TREE, 15"
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
SITE PREPARATION PLAN
CF CF
TWL TWL
SITE PREPARATION NOTES
1. REFER TO GENERAL PROJECT NOTES PRIOR TO BEGINNING THE
SITE REMOVAL SCOPE OF WORK.
2. REFER TO CIVIL AND MEP CONTRACT DOCUMENTS FOR UTILITY
REMOVALS.
3. REFER TO CIVIL CONTRACT DOCUMENTS FOR HARDSCAPE
REMOVALS.
4. CONTRACTOR TO STUDY THE CONTRACT DOCUMENTS AND VISIT
THE SITE TO DETERMINE THE ITEMS THAT MUST BE REMOVED TO
COMPLY WITH THE SITE DEVELOPMENT PLANS.
5. REFER TO THE MAINTENANCE OF TRAFFIC PLAN FOR TEMPORARY
SIGNAGE, BARRIERS AND MISCELLANEOUS FACILITIES REQUIRED
DURING CONSTRUCTION.
6. REFER TO CIVIL DRAWINGS FOR PROVISION OF TEMPORARY
POWER/WATER
7. CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE
UNTIL INSTALLATION. PROVIDE EQUIVALENT WARRANTY TO OTHER
PROVIDERS' PLANT MATERIAL. REPLACE ANY DAMAGED OR DEAD
MATERIAL WITH EQUIVALENT SIZE PLANTS.
8. LIMB UP EXISTING TREES, BY ARBORIST AT DIRECTION OF THE
LANDSCAPE ARCHITECT
SITE PREPARATION LEGEND
CONSTRUCTION FENCE
TEMPORARY WORK LIMIT
TREE PROTECTION FENCE
REMOVE TREE
1. TREE PROTECTION FENCING SHALL BE 4'-0" HEIGHT GALVANIZED STEEL
CHAIN LINK FENCE WITH IN-GROUND POSTS DIRECT BURIED. NO
CONSTRUCTION TRAFFIC, MATERIAL OR EQUIPMENT STORAGE SHALL BE
ALLOWED WITHIN FENCE LIMITS. PROVIDE 4'-0" WIDE GATED OPENINGS
FOR OWNER ACCESS AND MAINTENANCE. GATES SHALL BE LOCKABLE.
PROVIDE LOCKS AND KEYS FOR OWNER USE DURING CONSTRUCTION.
2. TREE PROTECTION FENCING LOCATIONS ARE FIXED. INSTALL FENCING
WHERE SHOWN ON THESE PLANS. ANY ADJUSTMENTS TO FENCING
LOCATIONS MUST BE APPROVED BY LANDSCAPE ARCHITECT. FENCE
LOCATIONS MUST BE APPROVED IN THE FIELD BY LANDSCAPE
ARCHITECT. ANY DEVIATION FROM THIS PLAN SHALL BE CORRECTED
PRIOR TO THE START OF CONSTRUCTION.
3. AN APPROVED LICENSED ARBORIST IS TO OVERSEE ALL REMOVALS
WITHIN CRITICAL ROOT ZONES OF EXISTING TREES TO REMAIN.
ARBORIST IS TO PERFORM TREE PRUNING AND ROOT PRUNING ON TREE
TO REMAIN PER SPECIFICATIONS AND AS NEEDED DURING
CONSTRUCTION.
4. TREE PROTECTION FENCING AND STORMWATER POLLUTION
PREVENTION PLAN (SWPPP) NOTICE OF INTENT SHALL BE IN PLACE
PRIOR TO BEGINNING DEMOLITION (AS REQUIRED).
5. FAILURE TO PROVIDE AND MAINTAIN TREE PROTECTION FENCE AND
INDICATED AREA BY CONTRACTOR WILL REQUIRE CONSULTATION WITH
LICENSED ARBORIST TO DETERMINE EXTENT OF DAMAGE. COST TO
REMEDIATE DAMAGES TO PROTECTED TREES AT CONTRACTOR COST.
TREE PROTECTION NOTESX X X X X X X XXXXXXXXXXXXX
X
X X2'-0"2'-0"
57 8"
PROPOSED EDGE OF
PAVEMENT (IF APPLICABLE)
CHAIN LINK FENCING
EXISTING TREE TO BE PROTECTED
DRIP LINE OF CANOPY ABOVE (TYP.)
TREE PROTECTION ZONE
PLAN | TREE PROTECTION - SINGLE TREE
1/8" 1'-0"
2
P-CCPL-50L-101
2'-0" 2'-0"2'-0"2'-0"
PLAN | TREE PROTECTION - MULTIPLE
3/32" 1'-0"
DRIP LINE OF
CANOPY ABOVE
(TYP.)
4' HIGH CHAIN LINK FENCE WITH
POSTS AT 10' O.C. MAXIMUM
EXISTING TREE TRUNK (TYP.)
3
P-CCPL-51L-101
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-101
SITE PREPARATION
PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
REMOVE FLAGPOLE.
SALVAGE PLAQUE AND
RELOCATE TO NEW FLAG
POLE BASE
10/19/20 Daren Mindham
W W WW W WW WW WW WOHUOHU OHU OHU OHU OHU OHUGGG GO
HUOHU OHU OHUN89°45'41"E (M) EAST (R) 653.40'
G
G
G
G
G
G
GW W W WWWN6
2
°
1
8
'
5
1
"
W
145
.
8
8
'
DELTA=46°49'28"
R=139.96'
T=60.60'
L=114.38'
CH BRG=N23°04'32"E
CH LEN=111.22'
N46°29'09"E 1
1
8
.
03'251.37'4TH AVE
N
U
E
EXISTING TREE, 36"
EXISTING TREE, 8"
EXISTING TREE, 12"
EXISTING TREE, 12"
EXISTING TREE, 10"
EXISTING TREE, 12"
EXISTING TREE, 12"
EXISTING TREE, 8"
EXISTING TREE, 12"
EXISTING TREE, 10"
SALVAGE PLANTERS, STORE FOR OWNER
TREE PROTECTION ON ADJACENT
PROPERTY TO BE INSTALLED
ELEMENTARY SCHOOL
CONTRACTOR
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
SITE PREPARATION PLAN
CF CF
TWL TWL
SITE PREPARATION NOTES
1. REFER TO GENERAL PROJECT NOTES PRIOR TO BEGINNING THE
SITE REMOVAL SCOPE OF WORK.
2. REFER TO CIVIL AND MEP CONTRACT DOCUMENTS FOR UTILITY
REMOVALS.
3. REFER TO CIVIL CONTRACT DOCUMENTS FOR HARDSCAPE
REMOVALS.
4. CONTRACTOR TO STUDY THE CONTRACT DOCUMENTS AND VISIT
THE SITE TO DETERMINE THE ITEMS THAT MUST BE REMOVED TO
COMPLY WITH THE SITE DEVELOPMENT PLANS.
5. REFER TO THE MAINTENANCE OF TRAFFIC PLAN FOR TEMPORARY
SIGNAGE, BARRIERS AND MISCELLANEOUS FACILITIES REQUIRED
DURING CONSTRUCTION.
6. REFER TO CIVIL DRAWINGS FOR PROVISION OF TEMPORARY
POWER/WATER
7. CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE
UNTIL INSTALLATION. PROVIDE EQUIVALENT WARRANTY TO OTHER
PROVIDERS' PLANT MATERIAL. REPLACE ANY DAMAGED OR DEAD
MATERIAL WITH EQUIVALENT SIZE PLANTS.
8. LIMB UP EXISTING TREES, BY ARBORIST AT DIRECTION OF THE
LANDSCAPE ARCHITECT
SITE PREPARATION LEGEND
CONSTRUCTION FENCE
TEMPORARY WORK LIMIT
TREE PROTECTION FENCE
REMOVE TREE
1. TREE PROTECTION FENCING SHALL BE 4'-0" HEIGHT GALVANIZED STEEL
CHAIN LINK FENCE WITH IN-GROUND POSTS DIRECT BURIED. NO
CONSTRUCTION TRAFFIC, MATERIAL OR EQUIPMENT STORAGE SHALL BE
ALLOWED WITHIN FENCE LIMITS. PROVIDE 4'-0" WIDE GATED OPENINGS
FOR OWNER ACCESS AND MAINTENANCE. GATES SHALL BE LOCKABLE.
PROVIDE LOCKS AND KEYS FOR OWNER USE DURING CONSTRUCTION.
2. TREE PROTECTION FENCING LOCATIONS ARE FIXED. INSTALL FENCING
WHERE SHOWN ON THESE PLANS. ANY ADJUSTMENTS TO FENCING
LOCATIONS MUST BE APPROVED BY LANDSCAPE ARCHITECT. FENCE
LOCATIONS MUST BE APPROVED IN THE FIELD BY LANDSCAPE
ARCHITECT. ANY DEVIATION FROM THIS PLAN SHALL BE CORRECTED
PRIOR TO THE START OF CONSTRUCTION.
3. AN APPROVED LICENSED ARBORIST IS TO OVERSEE ALL REMOVALS
WITHIN CRITICAL ROOT ZONES OF EXISTING TREES TO REMAIN.
ARBORIST IS TO PERFORM TREE PRUNING AND ROOT PRUNING ON TREE
TO REMAIN PER SPECIFICATIONS AND AS NEEDED DURING
CONSTRUCTION.
4. TREE PROTECTION FENCING AND STORMWATER POLLUTION
PREVENTION PLAN (SWPPP) NOTICE OF INTENT SHALL BE IN PLACE
PRIOR TO BEGINNING DEMOLITION (AS REQUIRED).
5. FAILURE TO PROVIDE AND MAINTAIN TREE PROTECTION FENCE AND
INDICATED AREA BY CONTRACTOR WILL REQUIRE CONSULTATION WITH
LICENSED ARBORIST TO DETERMINE EXTENT OF DAMAGE. COST TO
REMEDIATE DAMAGES TO PROTECTED TREES AT CONTRACTOR COST.
TREE PROTECTION NOTESX X X X X X X XXXXXXXXXXXXX
X
X X2'-0"2'-0"
57 8"
PROPOSED EDGE OF
PAVEMENT (IF APPLICABLE)
CHAIN LINK FENCING
EXISTING TREE TO BE PROTECTED
DRIP LINE OF CANOPY ABOVE (TYP.)
TREE PROTECTION ZONE
PLAN | TREE PROTECTION - SINGLE TREE
1/8" 1'-0"
2
P-CCPL-50L-102
2'-0" 2'-0"2'-0"2'-0"
PLAN | TREE PROTECTION - MULTIPLE
3/32" 1'-0"
DRIP LINE OF
CANOPY ABOVE
(TYP.)
4' HIGH CHAIN LINK FENCE WITH
POSTS AT 10' O.C. MAXIMUM
EXISTING TREE TRUNK (TYP.)
3
P-CCPL-51L-102
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-102
SITE PREPARATION
PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
3 CITY PERMIT COMMENTS 09/11/20
10/19/20 Daren Mindham
DELTA=46°49'28"
R=139.96'
T=60.60'
L=114.38'
EXISTING TREE, 36"
EXISTING TREE, 15"
EXISTING TREE, 12"
EXISTING TREE, 12"
EXISTING TREE, 15"
EXISTING TREE, 30"
EXISTING TREE, 36"
EXISTING TREE, 18"
EXISTING TREE, 18"
EXISTING TREES, 4"
EXISTING TREE, 15"
EXISTING TREE, 12"
EXISTING TREE, 12"
EXISTING TREE, 12"
SITE PREPARATION PLAN
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
CF CF
TWL TWL
SITE PREPARATION NOTES
1. REFER TO GENERAL PROJECT NOTES PRIOR TO BEGINNING THE
SITE REMOVAL SCOPE OF WORK.
2. REFER TO CIVIL AND MEP CONTRACT DOCUMENTS FOR UTILITY
REMOVALS.
3. REFER TO CIVIL CONTRACT DOCUMENTS FOR HARDSCAPE
REMOVALS.
4. CONTRACTOR TO STUDY THE CONTRACT DOCUMENTS AND VISIT
THE SITE TO DETERMINE THE ITEMS THAT MUST BE REMOVED TO
COMPLY WITH THE SITE DEVELOPMENT PLANS.
5. REFER TO THE MAINTENANCE OF TRAFFIC PLAN FOR TEMPORARY
SIGNAGE, BARRIERS AND MISCELLANEOUS FACILITIES REQUIRED
DURING CONSTRUCTION.
6. REFER TO CIVIL DRAWINGS FOR PROVISION OF TEMPORARY
POWER/WATER
7. CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE
UNTIL INSTALLATION. PROVIDE EQUIVALENT WARRANTY TO OTHER
PROVIDERS' PLANT MATERIAL. REPLACE ANY DAMAGED OR DEAD
MATERIAL WITH EQUIVALENT SIZE PLANTS.
8. LIMB UP EXISTING TREES, BY ARBORIST AT DIRECTION OF THE
LANDSCAPE ARCHITECT
SITE PREPARATION LEGEND
CONSTRUCTION FENCE
TEMPORARY WORK LIMIT
TREE PROTECTION FENCE
REMOVE TREE
1. TREE PROTECTION FENCING SHALL BE 4'-0" HEIGHT GALVANIZED STEEL
CHAIN LINK FENCE WITH IN-GROUND POSTS DIRECT BURIED. NO
CONSTRUCTION TRAFFIC, MATERIAL OR EQUIPMENT STORAGE SHALL BE
ALLOWED WITHIN FENCE LIMITS. PROVIDE 4'-0" WIDE GATED OPENINGS
FOR OWNER ACCESS AND MAINTENANCE. GATES SHALL BE LOCKABLE.
PROVIDE LOCKS AND KEYS FOR OWNER USE DURING CONSTRUCTION.
2. TREE PROTECTION FENCING LOCATIONS ARE FIXED. INSTALL FENCING
WHERE SHOWN ON THESE PLANS. ANY ADJUSTMENTS TO FENCING
LOCATIONS MUST BE APPROVED BY LANDSCAPE ARCHITECT. FENCE
LOCATIONS MUST BE APPROVED IN THE FIELD BY LANDSCAPE
ARCHITECT. ANY DEVIATION FROM THIS PLAN SHALL BE CORRECTED
PRIOR TO THE START OF CONSTRUCTION.
3. AN APPROVED LICENSED ARBORIST IS TO OVERSEE ALL REMOVALS
WITHIN CRITICAL ROOT ZONES OF EXISTING TREES TO REMAIN.
ARBORIST IS TO PERFORM TREE PRUNING AND ROOT PRUNING ON TREE
TO REMAIN PER SPECIFICATIONS AND AS NEEDED DURING
CONSTRUCTION.
4. TREE PROTECTION FENCING AND STORMWATER POLLUTION
PREVENTION PLAN (SWPPP) NOTICE OF INTENT SHALL BE IN PLACE
PRIOR TO BEGINNING DEMOLITION (AS REQUIRED).
5. FAILURE TO PROVIDE AND MAINTAIN TREE PROTECTION FENCE AND
INDICATED AREA BY CONTRACTOR WILL REQUIRE CONSULTATION WITH
LICENSED ARBORIST TO DETERMINE EXTENT OF DAMAGE. COST TO
REMEDIATE DAMAGES TO PROTECTED TREES AT CONTRACTOR COST.
TREE PROTECTION NOTESX X X X X X X XXXXXXXXXXXXX
X
X X2'-0"2'-0"
57 8"
PROPOSED EDGE OF
PAVEMENT (IF APPLICABLE)
CHAIN LINK FENCING
EXISTING TREE TO BE PROTECTED
DRIP LINE OF CANOPY ABOVE (TYP.)
TREE PROTECTION ZONE
PLAN | TREE PROTECTION - SINGLE TREE
1/8" 1'-0"
2
P-CCPL-50L-101
2'-0" 2'-0"2'-0"2'-0"
PLAN | TREE PROTECTION - MULTIPLE
3/32" 1'-0"
DRIP LINE OF
CANOPY ABOVE
(TYP.)
4' HIGH CHAIN LINK FENCE WITH
POSTS AT 10' O.C. MAXIMUM
EXISTING TREE TRUNK (TYP.)
3
P-CCPL-51L-101
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-103
SITE PREPARATION
PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
10/19/20 Daren Mindham
STOPYIELDYIELDYIELDYIELDYIELD YIELDYIELD YIELDYIELD YIELDYIELDSTOPSTOP
STOPWWWWWOHUOHU
OHUOHUGO
H
UOHUOHUN89°45'41"E (M) EAST (R) 653.40'
G
G
G
WWWWWN62°18'51"W
145.88'
DELTA=46°49'28"
R=139.96'
T=60.60'
L=114.38'
CH BRG=N23°04'32"E
CH LEN=111.22'N00°00'09"E (M) NORTH (R) 1000.00'N46°29'09"E 118.0
3'251.37'4TH
A
V
E
NUE
600CALC CORNER SET X IN WALK ON LINE
W WWWWOHUOHUOHU OHUGO
H
UOHUOHUN89°45'41"E (M) EAST (R) 653.40'
G
G
G
W WWWWN62°18 '51"W
145. 88'
DELTA=46°49'28"
R=139.96'
T=60.60'
L=114.38'
CH BRG=N23°04'32"E
CH LEN=111.22'N00°00'09"E (M) NORTH (R) 1000.00'N46°29'09"E 118.0
3'251.37'4TH
A
V
E
NUE ORIGIN (STARTING POINT)SURVEY ORIGIN(TO BE MODIFIED)R.O.W. LINE
R.O.W. LINEBOUNDARY LINE BOUNDARY LINE R.O.W. LINER.O.W. LINER.O.W. LINE
R.O.W. LINE R.O.W. LINE
BOUNDARY LINE BOUNDARY LINE BOUNDARY LINER.O.W. LINE
R.O.W. LINELIMITS OF W
OR
K
LIMITS OF WORKLIMITS OF WORK R.O.W. LINELIMIT S OF WORKLI
MIT
S
O
F
WO
R
K18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
CF CF
TWL TWL
SITE FEATURES NOTES
1. SITE UTILITIES SHOWN FOR REFERENCE ONLY. SEE OTHER
DISCIPLINE SHEETS FOR PLANS AND DETAILS.
2. AUTOCAD .DWG FILES WILL BE PROVIDED FOR CONSTRUCTION
LAYOUT.
3. ALL PAVEMENT MARKINGS INTERRUPTED BY DEMOLITION AND
PROPOSED IMPROVEMENTS SHALL BE REPLACED WITH
MATCHING COLOR AND WIDTH.
4. REFER TO OTHER DISCIPLINE SHEETS FOR REPAIR OF EXISTING
SURFACE DUE TO EXTENSION OF OFF-SITE UTILITIES.
5. CONCRETE JOINTS TO BE SAWCUT UNLESS NOTED OTHERWISE.
6. DAMAGE TO EXISTING PAVMENT SHALL BE REPLACED WITH
MATCHING COLOR AND FINISH BY CONTRACTOR.
SITE FEATURES LEGEND
CONSTRUCTION FENCE
TEMPORARY WORK LIMIT
TREE PROTECTION FENCING
ISOLATION JOINT
JOINT TYPE B PER
ALIGN
IJ
B
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-200
SITE FEATURES
OVERALL PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
3 TAC COMMENT REVISIONS 7/31/2020
4 ADDENDUM 1 8/3/2020
PLANTING OVERALL PLAN
L-203
L-202
L-202
L-201
4
4
10/19/20 Daren Mindham
YIELD YIELDYIELD YIELD600CALC CORNER SET X IN WALK ON LINE
ORIGIN (STARTING POINT)SURVEY ORIGIN(TO BE MODIFIED)R.O.W. LINEARY LINE
R.O.W. LINE BOUNDARY LINER.O.W. LINE
R.O.W. LINELIM
I
T
S
OF
WO
R
K
LIMITS OF WORK12-93- AB
12-93- C
12-93- D
12-93- D
12-93- DA
12-93- C
12-93- DA
12-93- C
12-93- D
03-31- A
12-93- AB
RELOCATED SALVAGED SCULPTURES
RELOCATED SALVAGED
SCULPTURES
04-43- A
04-43- A
TRENCH DRAIN,
SEE CIVIL
03-45- A
05-52- A
04-43- A
03-45- A
12-93- C
ADD ALTERNATE: UNIT PAVERS
12-93- CA
12-93- CA
12-93- CA
12-93- CA
12-93- CA
12-93- CA
12-93- C
03-30- A
03-45- A
03-30- A
05-52- A
03-30- A
CAST-IN-PLACE CONCRETE
CODE DESCRIPTION DETAIL
03-30- A CAST-IN-PLACE CONCRETE, EXTERIOR STEPS E4/L-702
03-31- A CONCRETE BASE FOR SCULPTURE A4/L-701
PRECAST ARCHITECTURAL CONCRETE
CODE DESCRIPTION DETAIL
03-45- A PRECAST ARCHITECTURAL CONCRETE, EXTERIOR STEPS,
ALTERNATE
A4/L-702
STONE MASONRY
CODE DESCRIPTION DETAIL
04-43- A EXTERIOR STONE, RETAINING WALL, LIMESTONE BLOCK
METAL RAILINGS
CODE DESCRIPTION DETAIL
05-52- A METAIL RAILINGS, 316 STAINLESS STEEL /
FLAGPOLES
CODE DESCRIPTION DETAIL
10-75- A FLAGPOLE, 25` HT ALUMINUM TAPERED IN-GROUND, WITH
SALVAGED PLAQUE AT BASE
A2/L-701
SITE FURNISHINGS
CODE DESCRIPTION DETAIL
12-93- A SITE FURNISHINGS, SARIS SQUARE TUBE BIKE DOCK A5/L-701
12-93- AB SITE FURNISHINGS, FORMS+SURFACES CORDIA BIKE RACK D5/L-701
12-93- B BIKE REPAIR STATION, DERO FIXIT B5/L-701
12-93- C SITE FURNISHINGS, LANDSCAPE FORMS SCARBOROUGH
LITTER RECEPTACLE, OWNER FURNISHED
C4/L-701
12-93- CA SITE FURNISHING, LANDSCAPE FORMS SCARBOROUGH
RECYCLING RECEPTACLE, OWNER FURNISHED
C4/L-701
12-93- D SITE FURNISHINGS, LANDSCAPE FORMS PLAINWELL 6` BENCH,
SURFACE MOUNT ON CONCRETE BASE, OWNER SUPPLIED
E3/L-701
12-93- DA SITE FURNISHINGS, LANDSCAPE FORMS PARALLEL 42 BENCH,
SURFACE MOUNT
E3/L-701
12-93- H SITE FURNISHING, UTILITY BOLLARD, 6" WITH PLASTIC COVERS,
COLOR: REFER TO SPECS.
PACKAGED HEATING AND COOLING UNITS
CODE DESCRIPTION DETAIL
23-91- A HEATING SYSTEM, INFLOOR, VIEGA SNOWMELT; REF: MECH.
DWGS.
EXTERIOR LIGHTING
CODE DESCRIPTION DETAIL
26-56- A EXTERIOR LIGHTING, AREA LIGHT; REF: ELECT. DWGS.
26-56- AB EXTERIOR LIGHTING, PEDESTRIAN POLE; REF: ELECT. DWGS.
26-56- AC EXTERIOR LIGHTING, BOLLARD LIGHT; REF: ELECT. DWGS.
FENCES AND GATES
CODE DESCRIPTION DETAIL
32-31- A FENCES AND GATES, DOUBLE SWING GATE, BASTEEL
PARIMETER SYSTEM
C5/L-703
RIGID PAVING
SYMBOL DESCRIPTION DETAIL
CONCRETE PAVING, INTEGRAL COLOR CONCRETE WITH
STANDARD RETARDER FINISH, COLOR C-34 DARK GRAY
/
CONCRETE PAVING, STANDARD, STANDARD RETARDER FINISH /
CONCRETE PAVING, STANDARD, BROOM FINISH /
AGGREGATE SURFACING
SYMBOL DESCRIPTION DETAIL
AGGREGATE SURFACING, DECOMPOSED GRANITE C3/L-702
SEGMENTAL RETAINING WALLS
SYMBOL DESCRIPTION DETAIL
LIMESTONE WALL A2/L-703
REFERENCE NOTES SCHEDULE
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
SITE FEATURES PLAN
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-201
SITE FEATURES
PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
3 TAC COMMENT REVISIONS 7/31/20
4 ADDENDUM 1 8/3/2020
MATCHLINE - SEE 1/L-202
26-56- AB
26-56- AB
26-56- AB
10-75- A
26-56- AB
12-93- C
23-91- A
12-93- HMATCHLINE - SEE L-20326-56- AB
32-31- A
4
10/19/20 Daren Mindham
STOPL
IM
I
T
S
OF
WORKYIELDYIELDYIELDYIELD YIELD YIELDYIELDYIELDYIELDSTOPSTOP
STO
PWWWWWWWWWWWWOHUOHUOHUOHUOHUGGGG O
HUOHUOHUOHUG
G
G
G
G
G
GWWWW4TH
AVE
N
U
E
W WWW W WWW W WW WOHUOHU OHU OHU OHUGGGGO
HUOHU OHU OHUG
G
G
G
G
G
GW W WW4TH
AVE
N
U
E
BOUNDARY LINE BOUNDARY LINELIMITS OF WORKR.O.W. LINELIMITS OF WORK12-93- A
12-93- B
12-93- C
26-56- A
12-93- CA
BY OTHERS
DRINKING FOUNTAIN,
SEE MEP
COORDINATE SIDEWALK
WITH CARMEL CLAY
SCHOOLS
CAST-IN-PLACE CONCRETE
CODE DESCRIPTION DETAIL
03-30- A CAST-IN-PLACE CONCRETE, EXTERIOR STEPS E4/L-702
03-31- A CONCRETE BASE FOR SCULPTURE A4/L-701
PRECAST ARCHITECTURAL CONCRETE
CODE DESCRIPTION DETAIL
03-45- A PRECAST ARCHITECTURAL CONCRETE, EXTERIOR STEPS,
ALTERNATE
A4/L-702
STONE MASONRY
CODE DESCRIPTION DETAIL
04-43- A EXTERIOR STONE, RETAINING WALL, LIMESTONE BLOCK
METAL RAILINGS
CODE DESCRIPTION DETAIL
05-52- A METAIL RAILINGS, 316 STAINLESS STEEL /
FLAGPOLES
CODE DESCRIPTION DETAIL
10-75- A FLAGPOLE, 25` HT ALUMINUM TAPERED IN-GROUND, WITH
SALVAGED PLAQUE AT BASE
A2/L-701
SITE FURNISHINGS
CODE DESCRIPTION DETAIL
12-93- A SITE FURNISHINGS, SARIS SQUARE TUBE BIKE DOCK A5/L-701
12-93- AB SITE FURNISHINGS, FORMS+SURFACES CORDIA BIKE RACK D5/L-701
12-93- B BIKE REPAIR STATION, DERO FIXIT B5/L-701
12-93- C SITE FURNISHINGS, LANDSCAPE FORMS SCARBOROUGH
LITTER RECEPTACLE, OWNER FURNISHED
C4/L-701
12-93- CA SITE FURNISHING, LANDSCAPE FORMS SCARBOROUGH
RECYCLING RECEPTACLE, OWNER FURNISHED
C4/L-701
12-93- D SITE FURNISHINGS, LANDSCAPE FORMS PLAINWELL 6` BENCH,
SURFACE MOUNT ON CONCRETE BASE, OWNER SUPPLIED
E3/L-701
12-93- DA SITE FURNISHINGS, LANDSCAPE FORMS PARALLEL 42 BENCH,
SURFACE MOUNT
E3/L-701
12-93- H SITE FURNISHING, UTILITY BOLLARD, 6" WITH PLASTIC COVERS,
COLOR: REFER TO SPECS.
PACKAGED HEATING AND COOLING UNITS
CODE DESCRIPTION DETAIL
23-91- A HEATING SYSTEM, INFLOOR, VIEGA SNOWMELT; REF: MECH.
DWGS.
EXTERIOR LIGHTING
CODE DESCRIPTION DETAIL
26-56- A EXTERIOR LIGHTING, AREA LIGHT; REF: ELECT. DWGS.
26-56- AB EXTERIOR LIGHTING, PEDESTRIAN POLE; REF: ELECT. DWGS.
26-56- AC EXTERIOR LIGHTING, BOLLARD LIGHT; REF: ELECT. DWGS.
FENCES AND GATES
CODE DESCRIPTION DETAIL
32-31- A FENCES AND GATES, DOUBLE SWING GATE, BASTEEL
PARIMETER SYSTEM
C5/L-703
RIGID PAVING
SYMBOL DESCRIPTION DETAIL
CONCRETE PAVING, INTEGRAL COLOR CONCRETE WITH
STANDARD RETARDER FINISH, COLOR C-34 DARK GRAY
/
CONCRETE PAVING, STANDARD, STANDARD RETARDER FINISH /
CONCRETE PAVING, STANDARD, BROOM FINISH /
AGGREGATE SURFACING
SYMBOL DESCRIPTION DETAIL
AGGREGATE SURFACING, DECOMPOSED GRANITE C3/L-702
SEGMENTAL RETAINING WALLS
SYMBOL DESCRIPTION DETAIL
LIMESTONE WALL A2/L-703
REFERENCE NOTES SCHEDULE
SITE FEATURES PLAN
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-202
SITE FEATURES
PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
3 TAC COMMENT REVISIONS 7/31/2020
4 ADDENDUM 1 8/3/2020
MATCHLINE - SEE L-201
SITE FEATURES PLAN
MATCHLINE - SEE 2/L-202
MATCHLINE - SEE 1/L-202
4
4
10/19/20 Daren Mindham
R.O.W. LINER.O.W. LINEBOUNDARY LINE BOUNDARY LINE R.O.W. LINER.O.W. LINE R.O.W. LINER.O.W. LINE R.O.W. LINEFENCES AND GATES
CODE DESCRIPTION DETAIL
32-31- A FENCES AND GATES, DOUBLE SWING GATE, BASTEEL
PARIMETER SYSTEM
C5/L-703
RIGID PAVING
SYMBOL DESCRIPTION DETAIL
CONCRETE PAVING, INTEGRAL COLOR CONCRETE WITH
STANDARD RETARDER FINISH, COLOR C-34 DARK GRAY
/
CONCRETE PAVING, STANDARD, STANDARD RETARDER FINISH /
CONCRETE PAVING, STANDARD, BROOM FINISH /
AGGREGATE SURFACING
SYMBOL DESCRIPTION DETAIL
AGGREGATE SURFACING, DECOMPOSED GRANITE C3/L-702
SEGMENTAL RETAINING WALLS
SYMBOL DESCRIPTION DETAIL
LIMESTONE WALL A2/L-703
SITE FURNISHINGS
CODE DESCRIPTION DETAIL
12-93- A SITE FURNISHINGS, SARIS SQUARE TUBE BIKE DOCK A5/L-701
12-93- AB SITE FURNISHINGS, FORMS+SURFACES CORDIA BIKE RACK D5/L-701
12-93- B BIKE REPAIR STATION, DERO FIXIT B5/L-701
12-93- C SITE FURNISHINGS, LANDSCAPE FORMS SCARBOROUGH
LITTER RECEPTACLE, OWNER FURNISHED
C4/L-701
12-93- CA SITE FURNISHING, LANDSCAPE FORMS SCARBOROUGH
RECYCLING RECEPTACLE, OWNER FURNISHED
C4/L-701
12-93- D SITE FURNISHINGS, LANDSCAPE FORMS PLAINWELL 6` BENCH,
SURFACE MOUNT ON CONCRETE BASE, OWNER SUPPLIED
E3/L-701
12-93- DA SITE FURNISHINGS, LANDSCAPE FORMS PARALLEL 42 BENCH,
SURFACE MOUNT
E3/L-701
12-93- E SITE FURNISHING, DRINKING FOUNTAIN, MOST DEPENDABLE
FOUNTAINS, 440 SM
12-93- H SITE FURNISHING, UTILITY BOLLARD, 6" WITH PLASTIC COVERS,
COLOR: REFER TO SPECS.
PACKAGED HEATING AND COOLING UNITS
CODE DESCRIPTION DETAIL
23-91- A HEATING SYSTEM, INFLOOR, VIEGA SNOWMELT; REF: MECH.
DWGS.
EXTERIOR LIGHTING
CODE DESCRIPTION DETAIL
26-56- A EXTERIOR LIGHTING, AREA LIGHT; REF: ELECT. DWGS.
26-56- AB EXTERIOR LIGHTING, PEDESTRIAN POLE; REF: ELECT. DWGS.
26-56- AC EXTERIOR LIGHTING, BOLLARD LIGHT; REF: ELECT. DWGS.
CAST-IN-PLACE CONCRETE
CODE DESCRIPTION DETAIL
03-30- A CAST-IN-PLACE CONCRETE, EXTERIOR STEPS E4/L-702
03-31- A CONCRETE BASE FOR SCULPTURE A4/L-701
PRECAST ARCHITECTURAL CONCRETE
CODE DESCRIPTION DETAIL
03-45- A PRECAST ARCHITECTURAL CONCRETE, EXTERIOR STEPS,
ALTERNATE
A4/L-702
STONE MASONRY
CODE DESCRIPTION DETAIL
04-43- A EXTERIOR STONE, RETAINING WALL, LIMESTONE BLOCK
METAL RAILINGS
CODE DESCRIPTION DETAIL
05-52- A METAIL RAILINGS, 316 STAINLESS STEEL /
FLAGPOLES
CODE DESCRIPTION DETAIL
10-75- A FLAGPOLE, 25` HT ALUMINUM TAPERED IN-GROUND, WITH
SALVAGED PLAQUE AT BASE
A2/L-701
REFERENCE NOTES SCHEDULE
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
SITE FEATURES PLAN
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-203
SITE FEATURES
PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
EXISTING STORMWATER
MANAGEMENT
DETENTION AREA
10/19/20 Daren Mindham
STOPSTOPSTOP
STOP YIELDYIELDYIELDYIELDYIELD YIELDYIELD YIELDYIELD YIELDYIELD600CALC CORNER SET X IN WALK ON LINE
W WWWWOHUOHUOHU OHUGO
H
UOHUOHUG
G
G
W WWWW4TH
A
V
E
N
U
E ORIGIN (STARTING POINT)SURVEY ORIGIN(TO BE MODIFIED)R.O.W. LINE
R.O.W. LINEBOUNDARY LINE BOUNDARY LINE R.O.W. LINER.O.W. LINER.O.W. LINE
R.O.W. LINE R.O.W. LINE
BOUNDARY LINE BOUNDARY LINE BOUNDARY LINER.O.W. LINE
R.O.W. LINELIMITS OF W
OR
K
LIMITS OF WORKLIMITS OF WORKR.O.W. LINELIMIT S OF WORKLI
MIT
S
O
F
WO
R
KIWR
ISG
ISG
ISG
IWR
IWR
IWR
IWR
IWR
IWR
ISG
ISGISG
124
DLO
IWR
1
L-500
PLANTING OVERALL PLAN
1"=20'-0"0 10' 20' 40'
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
FROM OUTSIDE INDIANAINSIDE INDIANA
1-800-428-52001-800-382-5544
(TWO WORKING DAYS PLEASE)
HOLEY MOLEY SAYS,
"CALL BEFORE YOU DIG"
GENERAL NOTES:
1. 2" MULCH SHREDDED HARDWOOD MULCH IN ALL PLANTED AREAS EXCEPT LAWN.
2. ALL TREES IN LAWN TO HAVE 6' DIAMETER MULCH RING.
3. ALL TREES TO BE STAKED WITH TWO SUPPORTS EACH.
4. TOPSOIL DEPTHS:
5.1. TURF - 6"
5.2. GROUND COVER/SHRUBS - 14"
5.3. TREE - DEPTH OF ROOTBALL AND 2X WIDTH
6. ALL TOP SOIL TO BE HORTICULTURAL SOILS WITH SPENT MUSHROOM COMPOST
PLANTING NOTES
1. PARTICIPATE IN THE PRE-INSTALLATION CONFERENCE FOR THE PLANTING
SCOPE OF WORK, ACCORDING TO THE PROJECT SPECIFICATIONS, PRIOR
TO COMMENCEMENT.
2. MATCH GRAPHIC REPRESENTATION SHOWN UNLESS
NOTED / DIMENSIONED OTHERWISE. REFER TO PROJECT DETAILS FOR
PLACEMENT OF HATCHED AREAS.
3. EXISTING AND PROPOSED UTILITIES THAT ARE SHOWN ARE FOR
REFERENCE ONLY. REFER TO THE SITE SURVEY FOR EXISTING UTILITIES
AND VERIFY IN THE FIELD. REFER TO THE MEP AND CIVIL PLANS FOR
PROPOSED UTILITIES.
4. COMMENCEMENT OF PLANTING SCOPE CONSTITUTES ACCEPTANCE OF
SITE CONDITIONS. ENSURE THAT NECESSARY AND SPECIFIED PLANTING
CONDITIONS HAVE BEEN ACHIEVED PRIOR TO LANDSCAPE INSTALLATION.
5. INSTALL SPECIFIED TURFGRASS SEED AT DISTURBED AREAS NOT
OTHERWISE IDENTIFIED FOR PLANT MATERIAL.
6. PROVIDE 2" ORGANIC MULCH AT ALL PLANTING AREAS.
7. REFER TO SPECIFICATIONS FOR PLANT STAGING, HANDLING, PLANTING,
AND STAKING REQUIREMENTS.
8. FAILURE TO FOLLOW PLANTING PLAN DESIGN WILL RESULT IN REMOVAL
OF NON-CONFORMING PLANTS AND PURCHASE OF NEW PLANTS AT COST
OF CONTRACTOR.
9. CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE UNTIL
INSTALLATION. PROVIDE EQUIVALENT WARRANTY TO OTHER PROVIDERS'
PLANT MATERIAL. REPLACE ANY DAMAGED OR DEAD MATERIAL WITH
EQUIVALENT SIZE PLANTS.
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-500
SITE OVERALL
PLANTING PLAN
1 100% CONSTRUCTION DOCUMENTS 7/15/2020
2 STATE SUBMISSION SET 7/17/2020
L-503
L-506
L-505
L-504
10/19/20 Daren Mindham
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
FROM OUTSIDE INDIANAINSIDE INDIANA
1-800-428-52001-800-382-5544
(TWO WORKING DAYS PLEASE)
HOLEY MOLEY SAYS,
"CALL BEFORE YOU DIG"
GENERAL NOTES:
1. 2" MULCH SHREDDED HARDWOOD MULCH IN ALL PLANTED AREAS EXCEPT LAWN.
2. ALL TREES IN LAWN TO HAVE 6' DIAMETER MULCH RING.
3. ALL TREES TO BE STAKED WITH TWO SUPPORTS EACH.
4. TOPSOIL DEPTHS:
5.1. TURF - 6"
5.2. GROUND COVER/SHRUBS - 14"
5.3. TREE - DEPTH OF ROOTBALL AND 2X WIDTH
6. ALL TOP SOIL TO BE HORTICULTURAL SOILS WITH SPENT MUSHROOM COMPOST
PLANTING NOTES
1. PARTICIPATE IN THE PRE-INSTALLATION CONFERENCE FOR THE PLANTING
SCOPE OF WORK, ACCORDING TO THE PROJECT SPECIFICATIONS, PRIOR
TO COMMENCEMENT.
2. MATCH GRAPHIC REPRESENTATION SHOWN UNLESS
NOTED / DIMENSIONED OTHERWISE. REFER TO PROJECT DETAILS FOR
PLACEMENT OF HATCHED AREAS.
3. EXISTING AND PROPOSED UTILITIES THAT ARE SHOWN ARE FOR
REFERENCE ONLY. REFER TO THE SITE SURVEY FOR EXISTING UTILITIES
AND VERIFY IN THE FIELD. REFER TO THE MEP AND CIVIL PLANS FOR
PROPOSED UTILITIES.
4. COMMENCEMENT OF PLANTING SCOPE CONSTITUTES ACCEPTANCE OF
SITE CONDITIONS. ENSURE THAT NECESSARY AND SPECIFIED PLANTING
CONDITIONS HAVE BEEN ACHIEVED PRIOR TO LANDSCAPE INSTALLATION.
5. INSTALL SPECIFIED TURFGRASS SEED AT DISTURBED AREAS NOT
OTHERWISE IDENTIFIED FOR PLANT MATERIAL.
6. PROVIDE 2" ORGANIC MULCH AT ALL PLANTING AREAS.
7. REFER TO SPECIFICATIONS FOR PLANT STAGING, HANDLING, PLANTING,
AND STAKING REQUIREMENTS.
8. FAILURE TO FOLLOW PLANTING PLAN DESIGN WILL RESULT IN REMOVAL
OF NON-CONFORMING PLANTS AND PURCHASE OF NEW PLANTS AT COST
OF CONTRACTOR.
9. CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE UNTIL
INSTALLATION. PROVIDE EQUIVALENT WARRANTY TO OTHER PROVIDERS'
PLANT MATERIAL. REPLACE ANY DAMAGED OR DEAD MATERIAL WITH
EQUIVALENT SIZE PLANTS.
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-501
SITE PLANTING
PLAN DETAILS
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
SECTION | PLUG PLANTING
3/4" 1'-0"
O.C.
SPACING
VARIES
SPECIFIED SOIL MIX
PERENNIAL OR NATIVE
GRASS PLUG - TOP OF PLUG
FLUSH W/ SURROUNDING
PLANTING SOIL
2" MULCH - SEE
SPECIFICATION
UNDISTURBED SUBGRADE
E1
P-CCPL-54L-501
MULCH - SEE
SPECIFICATION
TOPSOIL
SUBGRADE
LAWN
SHARP SPADE-CUT
EDGE
DETAIL | SPADE EDGING
3" 1'-0"
F1
P-CCPL-55L-501
10/19/20 Daren Mindham
MUCA Muhlenbergia capillaris `Pink Cloud` / Pink Muhly 1 Gal.
MD Muscari armeniacum `Dark Eyes` / Dark Eyes Grape Hyacinth 5 Gal.
NK Narcissus x `King Alfred` / King Alfred Daffodil 5 Gal.
PHLOX Phlox subulata `Drummond Pink` / Drummond Piunk Creeping Phlox 1 Gal.
SO Symphyotrichum oolentangiense / Sky-blue Aster 10 Flat
SHRUB AREAS CODE BOTANICAL / COMMON NAME SIZE SPACING REMARKS
DLO Diervilla lonicera / Dwarf Bush Honeysuckle 3 Gal. 36" o.c.
GROUND COVERS CODE BOTANICAL / COMMON NAME SIZE SPACING REMARKS
CM Coreopsis x `Moonbeam` / Moonbeam Coreopsis 24 Flat 14" o.c.
LM Lamium maculatum `Chequers` / Chequers Dead Nettle 10 Flat 18" o.c.
LR Lamium maculatum `Red Nancy` / Spotted Nettle 10 Flat 8" o.c.
NR Nepeta racemosa `Walker`s Low` / Catmint #1 18" o.c.
PVS Panicum virgatum `Shenandoah` / Shenandoah Switch Grass 1 Gal. 24" o.c.
SAL Sisyrinchium angustifolium `Lucerne` / Lucerne Blue Eyed Grass 24 Flat 12" o.c.
TS3 Superior Turf Sod / Shade Tolerant Blend Sod
TS2 Turf Seed Seed
TS Turf Sod / Drought Tolerant Fescue Blend Sod
MIXES CODE BOTANICAL / COMMON NAME SIZE SPACING REMARKS
BUFF Bufferyard Mix 1 Gal. 50% Rhus aromatica `Gro-Low` 1 Gal. @42" O.C. / 50% Xanthorhiza
simpicissima 1 Gal. 36" O.C.
GERA Geranium Mix 24 Flat 12" o.c. 50% Geranium maculatum,50% Geranium sanguineum
SEDG Native Sedge Mix Plug 14" o.c. Sporobolis heterolepis 40%
Carex pennsylvanica 40%
Carex brevoir 20%
SPB Spring Bulb Mix bulb 12" o.c. Narcissus 40%
Muscari 40%
Crocus 20%
(Spacing - Typ. bulb practices)
FORB Supplemental Native Forb Mix Plug 28" o.c. Echinacea purpurea 50%
Liatris spicata 30%
Eryngium yuccifolium 20%
SWAL Swale Mix Seed "Dry Bottom Detention Basin Seen Mix" or approved equal. See Mix
Schedule.
TREES CODE BOTANICAL / COMMON NAME SIZE REMARKS
CO3 Celtis occidentalis / Common Hackberry 2.5" Cal.
CC Celtis occidentalis `Chicagoland` / Common Hackberry 2.5" Cal.
CK Cladrastis kentukea / American Yellowwood 2.5" Cal.
GT Gleditsia triacanthos `Skyline` / Skyline Honey Locust 2.5" Cal.
JV Juniperus virginiana `Canaertii` / Eastern Red Cedar 8` ht.
LT1 Liriodendron tulipifera / Tulip Tree 2.5" Cal.
LT2 Liriodendron tulipifera / Tulip Poplar 4" Cal.
LT3 Liriodendron tulipifera / Tulip Poplar 5" Cal.
NW Nyssa sylvatica `Wildfire` / Black Gum 2.5" Cal.
OV Ostrya virginiana / American Hophornbeam 2.5" Cal.
PB Platanus x acerifolia `Bloodgood` / London Plane Tree 2.5" Cal.
QB Quercus bicolor / Swamp White Oak 2.5" Cal.
QR Quercus rubra / Red Oak 2.5" Cal.
QR2 Quercus rubra / Red Oak 4" Cal.
QRF Quercus rubur `Fastigiat / Fastigiate English Oak 2.5" Cal.
TA Tilia americana / American Linden 2.5" Cal.
TC Tsuga canadensis / Canadian Hemlock 8` ht.
UP Ulmus americana `Princeton` / American Elm 2.5" Cal.
UM1 Ulmus x `Morton Glossy` / Triumph Elm 2.5" Cal. Non-native
UM3 Ulmus x `Morton Glossy` TM / Triumph Elm 3" Cal.
UM2 Ulmus x `Morton Glossy` TM / Triumph Elm 4" Cal.
UNDERSTORY TREES CODE BOTANICAL / COMMON NAME SIZE REMARKS
CE Cercis canadensis / Eastern Redbud Multi-trunk 1.5" Cal.
CA Cornus alternifolia / Pagoda Dogwood 1.5" Cal.
SHRUBS CODE BOTANICAL / COMMON NAME SIZE REMARKS
*HYD *Transplanted Hydrangea N/A
BG Buxus x `Green Mountain` / Green Mountain Boxwood #3
HAB Hydrangea arborescens `Abetwo` / Incrediball Hydrangea 5 Gal.
HPL Hydrangea paniculata `Little Lime` / Little Lime Hydrangea 5 Gal.
IJD Ilex verticillata `Jim Dandy` / Jim Dandy Winterberry 5 Gal.
IRS Ilex verticillata `Red Sprite` / Red Sprite Winterberry #3
ISG Ilex verticillata `Southern Gentleman` / Southern Gentleman Winterberry Holly 5 Gal.
IWR Ilex verticillata `Winter Red` / Winter Red Holly 5 Gal.
INM Ilex x meserveae `Mondo` TM / Little Rascal Holly #3
IVHG Itea virginica `Henry`s Garnet` / Henry`s Garnet Sweetspire 5 Gal.
ITLH Itea virginica `Little Henry` TM / Virginia Sweetspire 5 Gal.
SM Syringa meyeri `Palibin` / Dwarf Korean Lilac #5
VDE Viburnum dentatum `Arrowwood` / Arrowwood Viburnum 5 Gal.
ACCENT PERENNIALS CODE BOTANICAL / COMMON NAME SIZE REMARKS
ALSC Allium schoenoprasum / Ornamental Chives BULB Allium schoenoprasum
AMCA Amorpha canescens / Leadplant 1 Gal.
AHU Amsonia hubrichtii / Arkansas Blue-star 1 Gal.
AP Anemone x hybrida `Pamina` / Pamina Anemone PLUG
COVE Coreopsis verticillata `Moonbeam` / Threadleaf Coreopsis 1 Gal.
HEPP Heuchera x `Plum Pudding` / Plum Pudding Coral Bells 1 Gal.
ISG
IWR
PLANT SCHEDULE
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
FROM OUTSIDE INDIANAINSIDE INDIANA
1-800-428-52001-800-382-5544
(TWO WORKING DAYS PLEASE)
HOLEY MOLEY SAYS,
"CALL BEFORE YOU DIG"
GENERAL NOTES:
1. 2" MULCH SHREDDED HARDWOOD MULCH IN ALL PLANTED AREAS EXCEPT LAWN.
2. ALL TREES IN LAWN TO HAVE 6' DIAMETER MULCH RING.
3. ALL TREES TO BE STAKED WITH TWO SUPPORTS EACH.
4. TOPSOIL DEPTHS:
5.1. TURF - 6"
5.2. GROUND COVER/SHRUBS - 14"
5.3. TREE - DEPTH OF ROOTBALL AND 2X WIDTH
6. ALL TOP SOIL TO BE HORTICULTURAL SOILS WITH SPENT MUSHROOM COMPOST
PLANTING NOTES
1. PARTICIPATE IN THE PRE-INSTALLATION CONFERENCE FOR THE PLANTING
SCOPE OF WORK, ACCORDING TO THE PROJECT SPECIFICATIONS, PRIOR
TO COMMENCEMENT.
2. MATCH GRAPHIC REPRESENTATION SHOWN UNLESS
NOTED / DIMENSIONED OTHERWISE. REFER TO PROJECT DETAILS FOR
PLACEMENT OF HATCHED AREAS.
3. EXISTING AND PROPOSED UTILITIES THAT ARE SHOWN ARE FOR
REFERENCE ONLY. REFER TO THE SITE SURVEY FOR EXISTING UTILITIES
AND VERIFY IN THE FIELD. REFER TO THE MEP AND CIVIL PLANS FOR
PROPOSED UTILITIES.
4. COMMENCEMENT OF PLANTING SCOPE CONSTITUTES ACCEPTANCE OF
SITE CONDITIONS. ENSURE THAT NECESSARY AND SPECIFIED PLANTING
CONDITIONS HAVE BEEN ACHIEVED PRIOR TO LANDSCAPE INSTALLATION.
5. INSTALL SPECIFIED TURFGRASS SEED AT DISTURBED AREAS NOT
OTHERWISE IDENTIFIED FOR PLANT MATERIAL.
6. PROVIDE 2" ORGANIC MULCH AT ALL PLANTING AREAS.
7. REFER TO SPECIFICATIONS FOR PLANT STAGING, HANDLING, PLANTING,
AND STAKING REQUIREMENTS.
8. FAILURE TO FOLLOW PLANTING PLAN DESIGN WILL RESULT IN REMOVAL
OF NON-CONFORMING PLANTS AND PURCHASE OF NEW PLANTS AT COST
OF CONTRACTOR.
9. CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE UNTIL
INSTALLATION. PROVIDE EQUIVALENT WARRANTY TO OTHER PROVIDERS'
PLANT MATERIAL. REPLACE ANY DAMAGED OR DEAD MATERIAL WITH
EQUIVALENT SIZE PLANTS.
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-502
SITE PLANTING
PLAN SCHEDULES
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
3 TAC COMMENT RESPONSE 7/31/2020
4 CITY PERMIT COMMENTS 09/11/20
3
3
10/19/20 Daren Mindham
R.O.W. LINEBOUNDARY LINE BOUNDARY LINE R.O.W. LINER.O.W. LINER.O.W. LINE
R.O.W. LINE R.O.W. LINE
EXISTING TREE, 36"
EXISTING TREE, 15"
EXISTING TREE, 12"
EXISTING TREE, 12"
EXISTING TREE, 15"
EXISTING TREE, 30"
EXISTING TREE, 36"
EXISTING TREE, 18"
EXISTING TREE, 18"
EXISTING TREES, 4"
EXISTING TREE, 15"
EXISTING TREE, 12"
EXISTING TREE, 12"
EXISTING TREE, 12"
TS2
44,306 sI
4,316 s
3
CE
1
L-503
PLANTING PLAN
1"=20'-0"0 10' 20' 40'
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
FROM OUTSIDE INDIANAINSIDE INDIANA
1-800-428-52001-800-382-5544
(TWO WORKING DAYS PLEASE)
HOLEY MOLEY SAYS,
"CALL BEFORE YOU DIG"
GENERAL NOTES:
1. 2" MULCH SHREDDED HARDWOOD MULCH IN ALL PLANTED AREAS EXCEPT LAWN.
2. ALL TREES IN LAWN TO HAVE 6' DIAMETER MULCH RING.
3. ALL TREES TO BE STAKED WITH TWO SUPPORTS EACH.
4. TOPSOIL DEPTHS:
5.1. TURF - 6"
5.2. GROUND COVER/SHRUBS - 14"
5.3. TREE - DEPTH OF ROOTBALL AND 2X WIDTH
6. ALL TOP SOIL TO BE HORTICULTURAL SOILS WITH SPENT MUSHROOM COMPOST
PLANTING NOTES
1. PARTICIPATE IN THE PRE-INSTALLATION CONFERENCE FOR THE PLANTING
SCOPE OF WORK, ACCORDING TO THE PROJECT SPECIFICATIONS, PRIOR
TO COMMENCEMENT.
2. MATCH GRAPHIC REPRESENTATION SHOWN UNLESS
NOTED / DIMENSIONED OTHERWISE. REFER TO PROJECT DETAILS FOR
PLACEMENT OF HATCHED AREAS.
3. EXISTING AND PROPOSED UTILITIES THAT ARE SHOWN ARE FOR
REFERENCE ONLY. REFER TO THE SITE SURVEY FOR EXISTING UTILITIES
AND VERIFY IN THE FIELD. REFER TO THE MEP AND CIVIL PLANS FOR
PROPOSED UTILITIES.
4. COMMENCEMENT OF PLANTING SCOPE CONSTITUTES ACCEPTANCE OF
SITE CONDITIONS. ENSURE THAT NECESSARY AND SPECIFIED PLANTING
CONDITIONS HAVE BEEN ACHIEVED PRIOR TO LANDSCAPE INSTALLATION.
5. INSTALL SPECIFIED TURFGRASS SEED AT DISTURBED AREAS NOT
OTHERWISE IDENTIFIED FOR PLANT MATERIAL.
6. PROVIDE 2" ORGANIC MULCH AT ALL PLANTING AREAS.
7. REFER TO SPECIFICATIONS FOR PLANT STAGING, HANDLING, PLANTING,
AND STAKING REQUIREMENTS.
8. FAILURE TO FOLLOW PLANTING PLAN DESIGN WILL RESULT IN REMOVAL
OF NON-CONFORMING PLANTS AND PURCHASE OF NEW PLANTS AT COST
OF CONTRACTOR.
9. CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE UNTIL
INSTALLATION. PROVIDE EQUIVALENT WARRANTY TO OTHER PROVIDERS'
PLANT MATERIAL. REPLACE ANY DAMAGED OR DEAD MATERIAL WITH
EQUIVALENT SIZE PLANTS.
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-503
SITE PLANTING
PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020MATCHLINE - SEE L-504EXISTING STORMWATER
MANAGEMENT
DETENTION AREA
10/19/20 Daren Mindham
600CALC CORNER SET X IN WALK ON LINE
ORIGIN (STARTING POINT)SURVEY ORIGIN(TO BE MODIFIED)BOUNDARY LINER.O.W. LINE R.O.W. LINELIM
I
TS
O
F
W
O
R
K
LIMITS OF WORKLT2
4
STING CONDITIONSSIDE BUFFERYARD "D"
SPECIAL USE INSTITUTIONAL, WITH
ADJACENT SINGLE FAMILY.
MIN. 30' BUFFERYARD REQUIRED.
SHADE OR EVERGREEN TREES: 8.
ORNAMENTAL TREES: 2.
SHRUBS: 20.
NO WORK IN R.O.W. /
OUTSIDE OF PATH. SIDE BUFFERYARD "D" MINIMUM 30'PROPERTY LINE LENGTH = 746'IWR
IWR
IWR
91.22'IWR
ISG
ISGISG
FORB
30
FORB
30
3
IJD
3
ISG
3
JV
7
VDE
SEDG
899
FORB
12
FORB
30
FORB
30
FORB
12
FORB
12
SEDG
1,291
FORB
30
FORB
30
FORB
30
FORB
31 6
HPL
FORB
12
3
IJD
4
IWR
TC
5
JV
EXISTING TREE, 18"
EXISTING TREE, 12"
EXISTING TREE, 18"
EXISTING TREE, 18"
EXISTING TREE, 18"
EXISTING
TREE, 18"
EXISTING
TREE, 12"
EXISTING TREE, 36"
EXISTING TREE, 24"
EXISTING TREE, 12"
EXISTING TREE, 24"
EXISTING TREE, 8"
1
TA
1
CC
1
NW
EXISTING TREE, 18"
EXISTING TREE, 15" 601 sI
BUFF
1,180 sI
BUFF
87
GERA
63
CM
GERA
120
CM
101
6
HAB
HAB
7
OV
1
GERA
68
CM
74
HAB
7
OV
1
CM
420
GERA
603
HAB
21
649
PVS
680
GERA20
ALSC
20
ALSC
IWR
BG
5
MD
30
SM
2
NR
24 16
ALSC
2
SM
5
BG
SAL
116
28
NK
TS
8,192 sI
SAL
510
ALSC
60
SAL
340
ALSC
60
SAL
340
ALSC
60
ALSC
20
SAL
58
SAL
58
ALSC
20
1
IJD
5
IRS
8
AHU
SAL
345
ALSC
60
ALSC
20
ALSC
20
REPAIR TURF FOR
IRRIGATION
ROUTING AS
NECESSARY
4,796 sI
TS3
PVS
425
TS
615 sI
TS
1,030 sI
TS
1,534 sI
1
UM1
1
UM2
1
UM3 1
LT3
1
LT1
1
LT2
SOD REPAIR AS
NECESSARY
ALONG NEW
WALKWAY
SEDG
700
234 sI
BUFF
LT2
2
QR2
2
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
FROM OUTSIDE INDIANAINSIDE INDIANA
1-800-428-52001-800-382-5544
(TWO WORKING DAYS PLEASE)
HOLEY MOLEY SAYS,
"CALL BEFORE YOU DIG"
1
L-504
PLANTING PLAN
1"=20'-0"0 10' 20' 40'
GENERAL NOTES:
1. 2" MULCH SHREDDED HARDWOOD MULCH IN ALL PLANTED AREAS EXCEPT LAWN.
2. ALL TREES IN LAWN TO HAVE 6' DIAMETER MULCH RING.
3. ALL TREES TO BE STAKED WITH TWO SUPPORTS EACH.
4. TOPSOIL DEPTHS:
5.1. TURF - 6"
5.2. GROUND COVER/SHRUBS - 14"
5.3. TREE - DEPTH OF ROOTBALL AND 2X WIDTH
6. ALL TOP SOIL TO BE HORTICULTURAL SOILS WITH SPENT MUSHROOM COMPOST
PLANTING NOTES
1. PARTICIPATE IN THE PRE-INSTALLATION CONFERENCE FOR THE PLANTING
SCOPE OF WORK, ACCORDING TO THE PROJECT SPECIFICATIONS, PRIOR
TO COMMENCEMENT.
2. MATCH GRAPHIC REPRESENTATION SHOWN UNLESS
NOTED / DIMENSIONED OTHERWISE. REFER TO PROJECT DETAILS FOR
PLACEMENT OF HATCHED AREAS.
3. EXISTING AND PROPOSED UTILITIES THAT ARE SHOWN ARE FOR
REFERENCE ONLY. REFER TO THE SITE SURVEY FOR EXISTING UTILITIES
AND VERIFY IN THE FIELD. REFER TO THE MEP AND CIVIL PLANS FOR
PROPOSED UTILITIES.
4. COMMENCEMENT OF PLANTING SCOPE CONSTITUTES ACCEPTANCE OF
SITE CONDITIONS. ENSURE THAT NECESSARY AND SPECIFIED PLANTING
CONDITIONS HAVE BEEN ACHIEVED PRIOR TO LANDSCAPE INSTALLATION.
5. INSTALL SPECIFIED TURFGRASS SEED AT DISTURBED AREAS NOT
OTHERWISE IDENTIFIED FOR PLANT MATERIAL.
6. PROVIDE 2" ORGANIC MULCH AT ALL PLANTING AREAS.
7. REFER TO SPECIFICATIONS FOR PLANT STAGING, HANDLING, PLANTING,
AND STAKING REQUIREMENTS.
8. FAILURE TO FOLLOW PLANTING PLAN DESIGN WILL RESULT IN REMOVAL
OF NON-CONFORMING PLANTS AND PURCHASE OF NEW PLANTS AT COST
OF CONTRACTOR.
9. CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE UNTIL
INSTALLATION. PROVIDE EQUIVALENT WARRANTY TO OTHER PROVIDERS'
PLANT MATERIAL. REPLACE ANY DAMAGED OR DEAD MATERIAL WITH
EQUIVALENT SIZE PLANTS.
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-504
SITE PLANTING
PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
MATCHLINE - SEE L-505MATCHLINE - SEE L-5031
L-507
10/19/20 Daren Mindham
YIELDYIELD YIELDYIELD YIELD YIELDYIELD YIELDYIELD YIELDYIELDWW WW WW WOHUOHU OHUG G GGO
HU
O
HU
OHU OHU OHUOHU OHU OHUG
GW WORIGIN (STARTING POINT)BOUNDARY LINE BOUNDARY LINELIMITS OF WORKR.O.W. LINELIMITS OF WORKREAR BUFFERYARD "A"
SPECIAL USE ISNTITUTIONAL, WITH
ADJACENT INSTITUTIONAL USE.
MIN. 10' BUFFERYARD REQUIRED.
FOUR EVERGREEN OR SHADE
TREES, 0 ORNAMENTAL, AND 10
SHRUBS PER 100 LF.SIDE BUFFERYARD "D"; MINIMUM 30'CANNOT BE ACHIEVED WITH EXISTING CONDITIONSPROPERTY LINE LENGTH = 491'NO WORK IN R.O.W. /
OUTSIDE OF PATH.
IWR
ISG
ISG
ISG
216.13'
IWR
IWR
63.14'66.00
'
62.
2
2
'400.68'PARKING LOT: SPECIAL USE,
(73) PARKING SPACES, 8 TREES, 40
SHRUBS, REQUIRED
(12) SHADE TREES, (50) SHRUBS
PROVIDED
SIDE BUFFERYARD "D"
SPECIAL USE ISNTITUTIONAL, WITH
ADJACENT SINGLE FAMILY.
MIN. 30' BUFFERYARD REQUIRED.
SHADE OR EVERGREEN TREES: 8.
ORNAMENTAL TREES: 2.
SHRUBS: 20.
UP
9
2
NW
2
CC
1
OV
IWR
3
ISG
3
HPL
3
THESE PARKING SPOTS DO NOT MEET
PLANTING REQUIREMENTS. EACH
PARKING SPACE MUST BE WITHIN 66'
OF A SHADE TREE.
FORB
12
CA
6
QRF
6
339
SAL
SAL
43
SAL
193
36
SAL
SAL
70 SAL
163 SAL
46
HPL
10
5
HPL10
VDE
4
UP
2
UP
PB
3
UP
1
IVHG
6
UP
2
IVHG
10
IVHG
5
UP
1
GT
1
PB
1
GT
1
QR
4
2
TA
3
NW
1
NW
1
CC
HPL
5
HPL
3
VDE
2
VDE
2
1
CK
1
TA
VDE
3
1
TA
4
TCHPL
3
1
TC
HPL
5
2
TC
1
CK
1
CC
SWAL
7,840 sI
EXISTING TREE, 36"
EXISTING TREE, 8"
REAR BUFFERYARD "A"; MIN. 10'
PROPERTY LINE LENGTH = 217'
EXISTING TREE, 12"
EXISTING TREE, 12"
EXISTING TREE, 10"
EXISTING TREE, 12"
EXISTING TREE, 12"
EXISTING TREE, 10"
2,075 sI
BUFF
225 sI
BUFF
3,485
SEDG
TS
4,316 sI
230 sI
TS
TS
145 sI
680
GERA20
ALSC
20
ALSC
84
AHU
124
DLO
378
SAL
PB
2
2
QB
3
CO3
3
QB
3,555 sI
BUFF
4,414 sI
TS
QR2
4
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
FROM OUTSIDE INDIANAINSIDE INDIANA
1-800-428-52001-800-382-5544
(TWO WORKING DAYS PLEASE)
HOLEY MOLEY SAYS,
"CALL BEFORE YOU DIG"
1
L-505
PLANTING PLAN
1"=20'-0"0 10' 20' 40'
GENERAL NOTES:
1. 2" MULCH SHREDDED HARDWOOD MULCH IN ALL PLANTED AREAS EXCEPT LAWN.
2. ALL TREES IN LAWN TO HAVE 6' DIAMETER MULCH RING.
3. ALL TREES TO BE STAKED WITH TWO SUPPORTS EACH.
4. TOPSOIL DEPTHS:
5.1. TURF - 6"
5.2. GROUND COVER/SHRUBS - 14"
5.3. TREE - DEPTH OF ROOTBALL AND 2X WIDTH
6. ALL TOP SOIL TO BE HORTICULTURAL SOILS WITH SPENT MUSHROOM COMPOST
PLANTING NOTES
1. PARTICIPATE IN THE PRE-INSTALLATION CONFERENCE FOR THE PLANTING
SCOPE OF WORK, ACCORDING TO THE PROJECT SPECIFICATIONS, PRIOR
TO COMMENCEMENT.
2. MATCH GRAPHIC REPRESENTATION SHOWN UNLESS
NOTED / DIMENSIONED OTHERWISE. REFER TO PROJECT DETAILS FOR
PLACEMENT OF HATCHED AREAS.
3. EXISTING AND PROPOSED UTILITIES THAT ARE SHOWN ARE FOR
REFERENCE ONLY. REFER TO THE SITE SURVEY FOR EXISTING UTILITIES
AND VERIFY IN THE FIELD. REFER TO THE MEP AND CIVIL PLANS FOR
PROPOSED UTILITIES.
4. COMMENCEMENT OF PLANTING SCOPE CONSTITUTES ACCEPTANCE OF
SITE CONDITIONS. ENSURE THAT NECESSARY AND SPECIFIED PLANTING
CONDITIONS HAVE BEEN ACHIEVED PRIOR TO LANDSCAPE INSTALLATION.
5. INSTALL SPECIFIED TURFGRASS SEED AT DISTURBED AREAS NOT
OTHERWISE IDENTIFIED FOR PLANT MATERIAL.
6. PROVIDE 2" ORGANIC MULCH AT ALL PLANTING AREAS.
7. REFER TO SPECIFICATIONS FOR PLANT STAGING, HANDLING, PLANTING,
AND STAKING REQUIREMENTS.
8. FAILURE TO FOLLOW PLANTING PLAN DESIGN WILL RESULT IN REMOVAL
OF NON-CONFORMING PLANTS AND PURCHASE OF NEW PLANTS AT COST
OF CONTRACTOR.
9. CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE UNTIL
INSTALLATION. PROVIDE EQUIVALENT WARRANTY TO OTHER PROVIDERS'
PLANT MATERIAL. REPLACE ANY DAMAGED OR DEAD MATERIAL WITH
EQUIVALENT SIZE PLANTS.
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-505
SITE PLANTING
PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
MATCHLINE - SEE L-506
MATCHLINE - SEE L-504
10/19/20 Daren Mindham
STOPSTO
PW WOHU OHU OHU OHUOHUOHU OHU OHU OHUGG GW W WWW W W W WWL
I
MI
T
S
O
F
WORKQR
4
NW
2
LT1
2
3
LT1
2
TAEXISTING TREE, 10"
EXISTING TREE, 12"
EXISTING TREE, 12"
EXISTING TREE, 8"
EXISTING TREE, 10"
TS
2,897 sI
4,414 s
TS
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
FROM OUTSIDE INDIANAINSIDE INDIANA
1-800-428-52001-800-382-5544
(TWO WORKING DAYS PLEASE)
HOLEY MOLEY SAYS,
"CALL BEFORE YOU DIG"
1
L-506
PLANTING PLAN
1"=20'-0"0 10' 20' 40'
GENERAL NOTES:
1. 2" MULCH SHREDDED HARDWOOD MULCH IN ALL PLANTED AREAS EXCEPT LAWN.
2. ALL TREES IN LAWN TO HAVE 6' DIAMETER MULCH RING.
3. ALL TREES TO BE STAKED WITH TWO SUPPORTS EACH.
4. TOPSOIL DEPTHS:
5.1. TURF - 6"
5.2. GROUND COVER/SHRUBS - 14"
5.3. TREE - DEPTH OF ROOTBALL AND 2X WIDTH
6. ALL TOP SOIL TO BE HORTICULTURAL SOILS WITH SPENT MUSHROOM COMPOST
PLANTING NOTES
1. PARTICIPATE IN THE PRE-INSTALLATION CONFERENCE FOR THE PLANTING
SCOPE OF WORK, ACCORDING TO THE PROJECT SPECIFICATIONS, PRIOR
TO COMMENCEMENT.
2. MATCH GRAPHIC REPRESENTATION SHOWN UNLESS
NOTED / DIMENSIONED OTHERWISE. REFER TO PROJECT DETAILS FOR
PLACEMENT OF HATCHED AREAS.
3. EXISTING AND PROPOSED UTILITIES THAT ARE SHOWN ARE FOR
REFERENCE ONLY. REFER TO THE SITE SURVEY FOR EXISTING UTILITIES
AND VERIFY IN THE FIELD. REFER TO THE MEP AND CIVIL PLANS FOR
PROPOSED UTILITIES.
4. COMMENCEMENT OF PLANTING SCOPE CONSTITUTES ACCEPTANCE OF
SITE CONDITIONS. ENSURE THAT NECESSARY AND SPECIFIED PLANTING
CONDITIONS HAVE BEEN ACHIEVED PRIOR TO LANDSCAPE INSTALLATION.
5. INSTALL SPECIFIED TURFGRASS SEED AT DISTURBED AREAS NOT
OTHERWISE IDENTIFIED FOR PLANT MATERIAL.
6. PROVIDE 2" ORGANIC MULCH AT ALL PLANTING AREAS.
7. REFER TO SPECIFICATIONS FOR PLANT STAGING, HANDLING, PLANTING,
AND STAKING REQUIREMENTS.
8. FAILURE TO FOLLOW PLANTING PLAN DESIGN WILL RESULT IN REMOVAL
OF NON-CONFORMING PLANTS AND PURCHASE OF NEW PLANTS AT COST
OF CONTRACTOR.
9. CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE UNTIL
INSTALLATION. PROVIDE EQUIVALENT WARRANTY TO OTHER PROVIDERS'
PLANT MATERIAL. REPLACE ANY DAMAGED OR DEAD MATERIAL WITH
EQUIVALENT SIZE PLANTS.
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-506
SITE PLANTING
PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
MATCHLINE - SEE L-505
10/19/20 Daren Mindham
IWR
COVE
4
LR
116
SO
6
GERA
74
ALSC
19
SPB
74
MUCA
4
AMCA
6
HEPP
22
IRS
4
IWR
1
IJD
1
AMCA
4
50
LM
3
SO
AP
6
AHU
19
GERA
48
SPB
43
ITLH
12
PHLOX
11
MUCA
10
SM
3
AMCA
3
INM
1
IRS
4
COVE
8
ALSC
27 12
IRS
2
INM
53
SAL
7
AMCA
7
MUCA COVE
20 51
GERA
51
SPB
56
SPB
20
LM
3
SO
2
AP
40
LR
32
AHU
AP
3
38
ALSC
56
SAL
6
AMCA
3
*HYD
24
MUCA
9
AMCA
GERA
50
ITLH
8
ALSC
34
SAL
57
SPB
65
AP
3
8
AHU
7
IRS
1
INM
3
SO
LM
16
LR
71
AP
3
20
COVE
22
PHLOX
50
GERA
50
SPB
AHU
16
1810400
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 SRXWK PHQQV\OYDQL D SWUHHW
IQGLDQDSROLV IQGLDQD 46204
3176334040
RATIO
55 4TH AYH SE
CDUPHO IN 46032
3178143900
CARMEL CLAY PUBLIC LIBRARY
CDUPHO COD\
PXEOLF LLEUDU\
RHQRYDWLRQ
55 4WK AY H SE
CDUPHO IN 46032
Structural Engineer
10 SKRVKRQH DULYH
CDUPHO IN 46032
3178181912
CE Solutions
1344 SRXWK RDQJHOLQH SXLW H 202
CDUPHO IN 46032
3173448044
KBSO Consulting, LLC
530 E OKL R SWUHHW SXLW H G
IQGLDQDSROLV IN 46204
3176557777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 EDVW 49WK SWUHHW
IQGLDQDSROLV IN 46205
3175368000
Design 27
6602 EDVW 75WK SWUHHW SXLWH 210
IQGLDQDSROLV IN 46250
3178426890
Walker Consultants
)ROM OUTSIDE INDIANAINSIDE INDIANA
1800428520018003825544
TWO WOR.ING DAYS PLEASE
HOLEY MOLEY SAYS
CALL BE)ORE YOU DIG
1
L507
ENLARGED PLAN SENSORY GARDEN
1 8
00 4816
GENERAL NOTES
12 MULCH SHREDDED HARDWOOD MULCH IN ALL PLANTED AREAS EXCEPT LAWN
2 ALL TREES IN LAWN TO HAVE 6
DIAMETER MULCH RING
3ALL TREES TO BE STA.ED WITH TWO SUPPORTS EACH
4TOPSOIL DEPTHS
51TUR) 6
52 GROUND COVERSHRUBS 14
53TREE DEPTH O) ROOTBALL AND 2X WIDTH
6ALL TOP SOIL TO BE HORTICULTURAL SOILS WITH SPENT MUSHROOM COMPOST
PLANTING NOTES
1 PARTICIPATE IN THE PREINSTALLATION CON)ERENCE )OR THE PLANTING
SCOPE O) WOR. ACCORDING TO THE PROJECT SPECI)ICATIONS PRIOR
TO COMMENCEMENT
2 MATCH GRAPHIC REPRESENTATION SHOWN UNLESS
NOTED DIMENSIONED OTHERWISE RE)ER TO PROJECT DETAILS )OR
PLACEMENT O) HATCHED AREAS
3 EXISTING AND PROPOSED UTILITIES THAT ARE SHOWN ARE )OR
RE)ERENCE ONLY RE)ER TO THE SITE SURVEY )OR EXISTING UTILITIES
AND VERI)Y IN THE )IELD RE)ER TO THE MEP AND CIVIL PLANS )OR
PROPOSED UTILITIES
4 COMMENCEMENT O) PLANTING SCOPE CONSTITUTES ACCEPTANCE O)
SITE CONDITIONS ENSURE THAT NECESSARY AND SPECI)IED PLANTING
CONDITIONS HAVE BEEN ACHIEVED PRIOR TO LANDSCAPE INSTALLATION
5 INSTALL SPECI)IED TUR)GRASS SEED AT DISTURBED AREAS NOT
OTHERWISE IDENTI)IED )OR PLANT MATERIAL
6 PROVIDE 2 ORGANIC MULCH AT ALL PLANTING AREAS
7 RE)ER TO SPECI)ICATIONS )OR PLANT STAGING HANDLING PLANTING
AND STA.ING RE4UIREMENTS
8 )AILURE TO )OLLOW PLANTING PLAN DESIGN WILL RESULT IN REMOVAL
O) NONCON)ORMING PLANTS AND PURCHASE O) NEW PLANTS AT COST
O) CONTRACTOR
9 CONTRACTOR TO SALVAGE NOTED PLANTS ON SITE AND STORE UNTIL
INSTALLATION PROVIDE E4UIVALENT WARRANTY TO OTHER PROVIDERS
PLANT MATERIAL REPLACE ANY DAMAGED OR DEAD MATERIAL WITH
E4UIVALENT SI=E PLANTS
COPYRIGHT NOTICE THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CON)IDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO NO OTHER USE
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT O) RATIO ALL
COMMON LAW RIGHTS O) COPYRIGHT AND OTHERWISE ARE HEREBY SPECI)ICALLY RESERVED
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO
SEAL _ DATE
L507
SITE PLANTING
ENLARGED PLAN
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
10/19/20 Daren Mindham
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-701
SITE DETAILS
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
9.6
33.6
30.0
2.38
32.0
A A
2113 Shown SECTION A-A
SCALE 1 : 8
DETAIL | SARIS BIKE RACK
3/4" 1'-0"
SURFACE INSTALL PER MANUFACTURERS INSTRUCTION
A5
P-CCPL-59L-701
NOTES:
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
2. DO NOT SCALE DRAWING.
3. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS
FOR PLANNING PURPOSES ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.
4. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY
THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE.
5. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER
REFERENCE NUMBER
FRONT VIEW
- LASER-CUT STEEL DOM TUBING.
- STAINLESS STEEL AIRCRAFT CABLE.
- PHILIPS AND STANDARD SCREWDRIVERS, STEEL CORE TIRE
LEVERS (2), HEADSET/PEDAL WRENCH, 8/10 AND
9/11MM CONE WRENCHES, TORX T-25, HEX KEY SET.
SPECIFICATIONS:
MATERIAL:
TOOL TETHERING:
TOOLS INCLUDED:
SIDE VIEW
BIKE REPAIR STATION
3/4" 1'-0"
B5
P-CCPL-58L-701
DETAIL | CORDIA BIKE RACK
3/4" 1'-0"
1'-8"2'-1012"1 12"
8"
8"2"SURFACE
MOUNTED WITH
EMBEDDED
ANCHORS
312"
D5
P-CCPL-56L-701
DETAIL | BENCH PAD
1/2" 1'-0"
6'-0"
VARIES, SEE PLANS
3'-0" MIN.
COMPANION SEATING
4'-0" MIN., SEE PLANS
6"
CL
SCHEDULED PAVING, SEE PLANS.
5" POURED-IN-PLACE CONCRETE PAD
SURFACE MOUNT, PER MANUFAACTURER
6' BENCH, BACKED
5" POURED-IN-PLACE
CONCRETE PAD
6' BENCH, BACKED
6" 6"
P-CCPL-60
E3
L-701
GRADE
1" ߰ 1'-0"
2'-4" 6'-0" MIN.REFER TO SPEC SECTION
107516 "GROUND SET
POLES"
CONCRETE
FOOTING
BLACK
ASPHALTUM
PAINT ON POLE
BELOW GRADE
STEEL
CENTERING
WEDGES
(6) #6 VERTICAL
BARS, #3 TIES
SPACES AT 12"
O.C.
SECTION | FLAG POLE BASE
WATERPROOF COMPOUND
2" DEEP
HARDWOOD WEDGES
REMOVE AFTER
TAMPING SAND
DRY SAND TIGHTLY TAMPED
AFTER ALIGNING POLE
FOUNDATION SLEEVE
HOT DIP GALVANIZED STEEL
STEEL BASE PLATE
STEEL SUPPORT
PLATE WELDED TO
STEEL GROUND SPIKE
ELECTRICAL CONDUIT; REF
ELECTRICAL DWGS.
25' HT LIGHT POLE
P-CCPL-561
A2
L-701
DETAIL | SCULPTURE PAD
3/4" 1'-0"
V.I.F. SCULPTURE WIDTH
4" 3'-6" MIN. 1'-4"
V.I.F. SCULPTURE WIDTH
V.I.F. SCULPTURE WIDTHSCULPTURE BASE,
SURFACE
RETARDER FINISH
6"6"6"3" CLEAR MIN., TYP.
#3 12" O.C., EW
(2) #3 BENT BAR,
12" LAP MIN.
(4) #4 VERTICAL
BARS WITH #3
CLOSED TIES AT
12" O.C.
PLAN VIEW
SECTION2" MIN.2" CHAMFER EDGE
FG
A4
P-CCPL-68L-701
DETAIL | SCARBOROUGH RECEPTACLE
3/4" 1'-0"
LIFT AND TURN
LID TO EMPTY
SURFACE MOUNT OPTIONS. NON-CORROSIVE
ANCHORING HARDWARE SUPPLIED
BY OTHERS. (4) Ø7/16" [Ø11] MOUNTING HOLES.3"6" x 8" WELDED-ON
BACKER PLATE WITH
5" x 7" VINYL SIGN
VERTICAL STRAP
BASKET INSERT
Ø24 37/64 [624]
11"
NOTE: PROVIDE
GRAPHICS PER USE. SEE
PLANS FOR LITTER VS
RECYCLING
C4
P-CCPL-75L-701
DETAIL | BIKE RACK TYPICAL PLAN
1/4" 1'-0" 3'-0", MIN.BIKE RACK, TYP. SEE PLANS
FOR PRODUCT
SCHEDULED PAVING, SEE PLANSCL2'-0, MIN. 3'-0"
CLCL
WALL OR CURB, SEE PLANS
BIKE FOOTPRINT
2'-0"3'-0", MIN. CLEAR ZONENOTE:
REFER TO PLANS FOR LAYOUT
E1
P-CCPL-564 L-701
STEEL PIPE FILLED WITH
CONCRETE
CONCRETE FOOTING
1'-8"
COMPACTED SUBGRADE4'-0"3'-6" DETAIL | PIPE BOLLARD
3/4" 1'-0"
(REF: CONCRETE
PAVING DETAILS)
PLASTIC COVER, YELLOW
A1
L-701 P-CCPL-566
10/19/20 Daren Mindham
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-702
SITE DETAILS
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
3 ADDENDUM 2 8/11/2020PLAN:
SECTION 'A-A':
A A
NOTES:
1. SET ESCUTCHEON PLATE ON
SILICONE ADHESIVE BASE.
2. SUBMIT COMPLETE SHOP
DRAWINGS FOR REVIEW PER
SPEC. 055213.
DETAIL | HANDRAIL POST ESCUTCHEON PLATE
6" = 1'-0"
13 16"
CL
15 16"
13 4"
3 4" 3 4" 1"1"34"1" 1"234"13 4" 13 4"
13 16" 15 16"
13 4"
HANDRAIL POST PER
ELEVATIONS AND DETAILS
HANDRAIL POST PER
ELEVATIONS AND DETAILS
FINISH GRADE
PAVING OR STAIR TREAD
SUBSTRATE PER PLANS AND
DETAILS
NON-SHRINK GROUT PER
HANDRAIL EMBEDMENT
DETAILS
JOINT SEALANT (CLEAR), TYP.
CORE DRILL HOLE
3 12" x 2 3 4" ESCUTCHEON PLATE
(SPEC. 055213)
3 12" x 2 3 4" ESCUTCHEON PLATE
(SPEC. 055213)
CORE DRILL HOLE
C1
P-CCPL-64L-702
SECTION | PEDESTRIAN LIGHT POLE PAD
CL
CENTERLINE OF LIGHT POLE
LIGHT POLE (REF: ELEC.
DWGS.)
LIGHT POLE ANCHOR BOLT
SHROUD (REF: ELEC. DWGS.)
ORGANIC MULCH
(SPEC. 329300)
FINISH GRADE
PLANTING SOIL MIX FOR
PLANTS (SPEC. 329119)
CONCRETE PAVING OVERLAY
PER PLANS AND DETAILS
CAST-IN-PLACE CONCRETE
POLE BASE (REF: ELEC. DWGS.)
ANCHOR BOLTS, CONDUIT AND
GROUNDING (REF: ELEC.
DWGS.)
NOTE:
'D' = DEPTH PER CONCRETE PAVING DETAILS
1'-6"
9" 9" 'D'1/2" = 1'-0"
E1
P-CCPL-66L-702
'B'
EQ.
CL
EQ.
CENTERLINE OF LIGHT POLE
LIGHT POLE (REF: ELEC.
DWGS.)
LIGHT POLE ANCHOR BOLT
SHROUD (REF: ELEC. DWGS.)
ORGANIC MULCH
(SPEC. 329300)
FINISH GRADE
PLANTING SOIL MIX FOR
PLANTS (SPEC. 329119)
CONCRETE PAVING OVERLAY
PER PLANS AND DETAILS
CAST-IN-PLACE CONCRETE
POLE BASE (REF: ELEC. DWGS.)
ANCHOR BOLTS, CONDUIT AND
GROUDING (REF: ELEC. DWGS.)
NOTE:
'B' = WIDTH OF CONCRETE POLE BASE PER PLANS
PEDESTRIAN LIGHT POLE PAD | IN PLANTING
1/2" = 1'-0"
E3
P-CCPL-65L-702
4"FACE OF UTILITY
OR STRUCTURE
MINERAL MULCH,
FLUSH WITH FINISH GRADE
FILTER FABRIC,
TYP.
STEEL EDGING
FINISH GRADE
COMPACTED SUBGRADE
1" = 1'-0"
DETAIL | MAINTENANCE STRIP
1'-0"
C3
P-CCPL-67L-702
SECTION | AGGREGATE SURFACE PAVING
1 1/2" = 1'-0"
COMPACTED No. 53 STONE BASE
COMPACTED SUBGRADE TO
95% STANDARD PROCTOR
FINISH GRADE
6" 4"STABLIZED DECOMPOSED
GRANITE SURFACING
(SPEC. 321540), COMPACTED IN 2"
LIFTS
L-702 P-CCPL-560
A31'-6" 3"CLR. 3"CLR.4"
#3 VERT. @ 24" O.C.
#3 HORIZ. (CONT.) @ TOP &
BOTTOM
TRANSVERSE MEDIUM BROOM
FINISH
14" EDGE RADIUS, TYP.
CONCRETE RIBBON CURB
PLANTING AREA
FINISH GRADE
ISOLATION JOINT
(REF: )
SECTION | CONCRETE RIBBON CURB
SECTION
CONCRETE PAVING
(LIGHT DUTY)
D1/L-201
1 1/2" = 1'-0"
A1
P-CCPL-74L-702
DETAIL | HANDRAIL
1/2" = 1'-0"
T/STEP
SEE GRADING
FINISH GRADE
SEE GRADING 2'-10" 1'-0"1'-0"4" 1'-0"2'-8" 1'-0"116" EASED RADIUS, TYP.
MIN.MIN.
1'-8"
6'-8"
TERMINAL HANDRAIL POST:
1 12" X 3 4" RECTANGULAR 316 STAINLESS STEEL TUBE,
COLOR TBD TNEMEC PAINT
HANDRAIL:
1 12" X 3 4" RECTANGULAR 316 STAINLESS STEEL TUBE,
COLOR TBD TNEMEC PAINT
A2
L-703
SECTION
RETAINING WALL
A4
L-702
SECTION
PLAZA PRECAST STEPS
(ALTERNATE)
SCHEDULED PAVING, SEE CIVIL
C4
P-CCPL-77L-702
1'-0"
TYP.8" 3'-6"B/FTG.
T/STEP
SEE GRADING
FINISH GRADE
SEE GRADING 1'-0"4" 4" 4"1'-0"MIN.8"1'-6"
1'-4" 1'-4" 1'-4"
T/WALL
SEE GRADING
1'-4"SECTION
RETAINING WALL
SECTION | PLAZA STEPS
1/2" = 1'-0"
C4
L-702
DETAIL
HANDRAIL
ALTERNATE: SNOW MELT SYSTEM, SEE MEP
THICKEN CONCRETE PAVEMENT AT TOP OF STAIRS, TYP.
1
2"ØX18" DOWELS SET AT 24" O.C MIN. AT
CONCRETE SLAB EXPANSION JOINTS, FILL
VOIDS W/ NON-SHRINK EPOXY GROUT
CAST-IN-PLACE CONCRETE STAIRS
CAST IN PLACE CONCRETE BASE
COMPACTED AGGREGATE BASE
COMPACTED SUBGRADE
#5 @ 12" O.C. BOTH WAYS, EACH FACE, TYP.
SCHEDULED PAVING, SEE CIVIL
A2
L-703
12"R1
2"
2", TYP.
E4
L-702 P-CCPL-569
1'-0"
TYP. 8" 3'-6"B/FTG.
T/STEP
SEE GRADING
FINISH GRADE
SEE GRADING 1'-0"4" 4" 4"1'-0"MIN.8"1'-6"
1'-4" 1'-4" 1'-4"
3"
T/WALL
SEE GRADING
1'-4" SECTION
RETAINING WALL
SECTION | PLAZA PRECAST STEPS (ALTERNATE)
1/2" = 1'-0"
C4
L-702
DETAIL
HANDRAIL
JOINT SEALANT W/ BACKER ROD (SPEC. 079200), TYP.
ALTERNATE: SNOW MELT SYSTEM, SEE MEP
THICKEN CONCRETE PAVEMENT AT TOP OF
STAIRS, TURN DOWN REINFORCING, TYP.
1
2"ØX18" DOWELS SET AT 24" O.C MIN. AT
CONCRETE SLAB EXPANSION JOINTS, FILL
VOIDS W/ NON-SHRINK EPOXY GROUT
18" /FT WASH
ARCHITECTURAL PRECAST CONCRETE STAIR TREAD SET ON
MORTAR BASE W/ 1
2"Ø X 4" MIN. SS PIN, 2 PER PIECE, MIN.
4000 PSI, COLOR: REFER TO SPEC.
CAST IN PLACE CONCRETE BASE
COMPACTED AGGREGATE BASE
COMPACTED SUBGRADE
#5 @ 12" O.C. BOTH WAYS, EACH FACE, TYP.
SCHEDULED PAVING, SEE CIVIL
1" = 1'-0"
1 2" 3" R12"
1'-7"
A2
L-703
2", TYP.
A4
L-702 P-CCPL-62
3
3
10/19/20 Daren Mindham
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-703
SITE DETAILS
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
3 ADDENDUM 2 8/11/2020
SECTION | RETAINING WALL
3/4" 1'-0" P-CCPL-736" 3'-6"3"CLR.1'-4"VARIES12" T/WALL
SEE GRADING
PLAN
136 STAINLESS STEEL SKATE
DETERANT INSERT, D135-12 CHAMFER
BY SKATESTOPPERS, WITH LOCKING
PIN FOR GROUT JOINT, PER
MANUFACTURER.
1" CHAMFER (ALL CORNERS)
FINISH GRADE
SEE GRADING
PLAN
DOLOMITIC LIMESTONE BLOCK W/ BUSH
HAMMER FINISH EXPOSED VERTICAL
SURFACES (ALL OTHER FACES SHALL
BE SMOOTH SAWN)
ISOLATION JOINT WITHOUT DOWEL
SCHEDULED PAVING, SEE PLANS
COMPACTED SUBGRADE
MORTAR SETTING BED
STAINLESS STEEL MASONRY DOWEL:
3 4" Ø X 1'-6" PER OTHER DETAILS
(EMBED 9" IN CONCRETE; DRILL AND
EPOXY W/ HILTY HY-200)
CAST-IN-PLACE CONCRETE
FOUNDATION
#5 @ 12" O.C. (EACH FACE)
(4) #5 CONT. (EACH FACE)
SCHEDULED PAVING OR PLANTING,
SEE PLANS
18" WASH
1" WEEP HOLE
A2
P-CCPL-73L-703
CONCRETE PAVING JOINT DETAILS
1 1/2" 1'-0"
SAWCUT JOINT
TOOLED ISOLATION JOINT (1/4" EDGE
RADIUS) W/ PRE-FORMED JOINT MATERIAL,
ZIP-STRIP AND SEALANT
NOTE:
DO NOT RETRACE TOOLED JOINTS AFTER
BROOM FINISH, UNLESS NOTED
OTHERWISE.
18"1"18"1"12"
12"
BUILDING FACE AT
BUILDING ENTRY
THAT REQUIRES
PROTECTION FROM
FROST HEAVE OF
THE CONCRETE
PAVING
ISOLATION JOINT WITHIN PAVING:
ISOLATION JOINT @ VERTICAL CONSTRUCTION (FOR BUILDING ENTRY):
CONTRACTION JOINT 'A' (SINGLE CUT JOINT):
CONTRACTION JOINT 'B' (DOUBLE CUT JOINT):
NOTE:
SAWCUT JOINT AS SOON AS POSSIBLE
AFTER THE CONCRETE HARDENS. THE
CONCRETE IS HARD ENOUGH WHEN THE
BLADE DOES NOT DISLODGE AGGREGATE
AND WHEN THE EDGES OF THE CUT DO
NOT RAVEL. COMPLETE SAWCUTTING
BEFORE SHRINKAGE BECOMES
SUFFICIENT TO PRODUCT CRACKING.
3"
NOTE:
DO NOT RETRACE TOOLED JOINTS AFTER
BROOM FINISH, UNLESS NOTED
OTHERWISE.
TOOLED ISOLATION JOINT (1/4" EDGE
RADIUS) W/ PRE-FORMED JOINT MATERIAL,
ZIP-STRIP AND SEALANT
NOTE:
SAWCUT JOINT AS SOON AS POSSIBLE
AFTER THE CONCRETE HARDENS. THE
CONCRETE IS HARD ENOUGH WHEN THE
BLADE DOES NOT DISLODGE AGGREGATE
AND WHEN THE EDGES OF THE CUT DO
NOT RAVEL. COMPLETE SAWCUTTING
BEFORE SHRINKAGE BECOMES
SUFFICIENT TO PRODUCT CRACKING.
SAWCUT JOINT W/ BEVELED EDGE AS
SHOWN (BASED ON PROEDGE BEVELED
BLADE PROFILE 'XL-V23')
CONCRETE PAVING
CONCRETE PAVING
CONCRETE PAVING
CONCRETE PAVING (REF: CIVIL DWGS.)
'DIAMOND DOWEL' TAPERED PLATE DOWEL
@ 24" O.C.; INSTAL PER MANUFACTURER
INSTRUCTIONS
WELDED-WIRE REINFORCEMENT PER
PAVING DETAIL (IF REQUIRED)
1/4"1"CONTRACTION JOINT 'C' (TOOLED EDGE RADIUS):
NOTE:
DO NOT RETRACE TOOLED JOINTS AFTER
BROOM FINISH, UNLESS NOTED
OTHERWISE.
TOOLED CONTRACTION
JOINT W/ 1/4" EDGE RADIUS (EACH SIDE)
CONCRETE PAVING
WELDED-WIRE REINFORCEMENT PER
PAVING DETAIL
14"5 8"
TOOLED ISOLATION JOINT (1/4" EDGE
RADIUS) W/ PRE-FORMED JOINT MATERIAL,
ZIP-STRIP AND SEALANT
NOTE:
DO NOT RETRACE TOOLED JOINTS AFTER
BROOM FINISH, UNLESS NOTED
OTHERWISE.
12"
BUILDING FACE,
STRUCTURE,
COLUMN, AND/OR
WALL NOT
REQUIRING JOINT
DOWEL FOR
CONTROLLING
FROST HEAVE
ISOLATION JOINT @ VERTICAL CONSTRUCTION (NOT @ BUILDING ENTRY):
3"
CONCRETE PAVING
12"L x 3/8"Ø JOINT DOWEL @ 24" O.C.
DRILL HOLE 1/8" LARGER THAN JOINT
DOWEL Ø TO ALLOW FREE MOVEMENT
WELDED-WIRE REINFORCEMENT PER
PAVING DETAIL
WELDED-WIRE REINFORCEMENT PER
PAVING DETAIL
WELDED-WIRE REINFORCEMENT PER
PAVING DETAIL
WELDED-WIRE REINFORCEMENT PER
PAVING DETAIL
A1
P-CCPL-70L-703
ELEVATION | DOUBLE SWING GATE
1/2" 1'-0"
NOTES:
1. SEE PLANS FOR GATE LOCATIONS AND
OVERALL OUT-TO-OUT DIMENSIONS.
2. SUBMIT COMPLETE SHOP DRAWINGS FOR
EACH GATE WITH A UNIQUE OVERALL
OUT-TO-OUT DIMENSION.10'-4"3'-6" MIN. 3"VARIES2" 4" OVERALL OUT-TO-OUT DIMENSION PER PLANS
3"9" 9"EQ. EQ. FINISH GRADE;
REF: GRADING PLANS
HINGE ASSEMBLY
WELDED TO FRAME, TYP.
4" SQ. POST STANDARD BASTEEL
PAINTED FINISH, COLOR SELECTED
BY ARCHITECT, TYP.
BASTEEL PERIMETER SYSTEMS,
WINDSOR INFILL, TYP.
CONCRETE FOOTING, TYP.
BASTEEL PERIMETER SYSTEMS,
INFINITY DOUBLE SWING GATE
2X4 STEEL TUBE FRAMING, TYP.,
PER MANUFACTURER
1" INDUSTRIAL CANE BOLTS
WITH STAINLESS STEEL ROD
KEEPER AND CANE GUIDE, PER
MANUFACTURER
SLIDE BOLT WITH PADLOCK
VERFIY HINGE
CLEARANCE W/ MNFR.
P-CCPL-567
C5
L-703DETAIL | PAVER LAYOUT (ALTERNATE)
1/2" 1'-0"
TYPICAL PAVER PANEL,
HANOVER PREST; SIZES:
20% 12X12, 20% 12X18, 20%
12X24, 15% 24X24,15%
24X36; COLOR: 40% #1240,
30% #1185, 20% SUPER
BLACK, 10% #1119
CONCRETE BAND, INTEGRAL
COLOR:DARK CHARCOAL
TYPICAL PAVER PANEL,
HANOVER PREST; SIZES: 60%
6X12, 25% 6X24, 25% 6X36;
COLOR: 40% SUPER BLACK,
25% #1185, 25% #1240, 10%
#1119
C2
P-CCPL-570L-703
SECTION | UNIT PAVING (ALTERNATE)
1 1/2" 1'-0"5"4" 3 4" BITUMINOUS SETTING BED
COMPACTED SUBGRADE TO 95%
STANDARD PROCTOR
SCHEDULED UNIT PAVING
MASTIC ADHESIVE
34 "TACK COAT214"FINISH GRADE
BITUMINOUS SETTING BED APPLICATION
NOTES:
1. SEE DIVISION 32 OF THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
2. UNIT PAVING JOINTS: UNIT PAVERS TO HAVE A CONSISTENT SAND SWEPT JOINT IN
ACCORDANCE WITH THE SPECIFICATIONS.
3. DO NOT CREATE DAM CONDITIONS IN CONCRETE PAVING SUBSTRATE THAT WILL
PREVENT THE FLOW OF SUBSURFACE DRAINAGE RUNOFF. IF DAM CONDITIONS OR
OTHER LOW POINTS EXIST IN THE CONCRETE PAVING SUBSTRATE, PROVIDE 2"Ø
WEEP HOLES AT 2'-0" O.C. AS REQUIRED TO SUFFICIENTLY DRAIN THE CONCRETE
SURFACE. FILL WEEP HOLES WITH A FREE-DRAINING AGGREGATE AND COVER WITH
AN 8" SQUARE SEPARATION GEOTEXTILE SECURED BY TACK COAT.
4. SUBMIT SHOP DRAWINGS FOR ALL UNIT PAVING AREAS INDICATING PROPOSED
ISOLATION AND CONTRACTION JOINTS IN CONCRETE BASE.
CONCRETE PAVING
COMPACTED No. 53 STONE BASE
ALTERNATE: HEATING SYSTEM;
REF: MEP
1" DRAIN HOLES AT 24" O.C.,
FILLED WITH FREE DRAINING
AGGREGATE
L-703 P-CCPL-568
E2
SECTION | WALL AND PLANTING AREA
3/4" 1'-0"
1'-4" 5'-4"
T/WALL
SEE GRADING
UPPER PLAZA LOWER PLAZAPLANTING AREA
SOIL MIX (SPEC. 329119)SLOPE VARIES
SLOPE VARIES FINISH GRADE
2" DEPTH ORGANIC MULCH
(SPEC. 329300)
A2
L-703
SCHEDULED PAVING,
SEE CIVIL
B/WALL
SEE GRADING
L-703 P-CCPL-565
A4
3
10/19/20 Daren Mindham
18104.00
Owner
Mechanical / Electrical Engineer
Civil Engineer
Architect
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
RATIO
55 4TH Ave. SE
Carmel, IN 46032
317-814-3900
CARMEL CLAY PUBLIC LIBRARY
Carmel Clay
Public Library
Renovation
55 4th Ave SE
Carmel, IN 46032
Structural Engineer
10 Shoshone Drive
Carmel, IN 46032
317-818-1912
CE Solutions
1344 South Rangeline, Suite 202
Carmel, IN 46032
317-344-8044
KBSO Consulting, LLC
530 E. Ohio Street, Suite G
Indianapolis, IN 46204
317-655-7777
Civil & Environmental Consultants, INC
Technology Design
Garage Consultant
1650 East 49th Street
Indianapolis, IN 46205
317-536-8000
Design 27
6602 East 75th Street, Suite 210
Indianapolis, IN 46250
317-842-6890
Walker Consultants
COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND
SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE,
DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL
COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.
SHEET TITLE
SHEET NUMBER
SHEET ISSUE
PROJECT NO.
SEAL | DATE
L-704
SITE DETAILS
1 100% CONSTRUCTION DOCUMENTS 7/14/2020
2 STATE SUBMISSION SET 7/17/2020
ELEVATION | WALL AT PLANTER
3/8" 1'-0"
E4
L-702 A4
L-703
T/WALL
T/STEPS
FINISH GRADE
B/WALL 1'-4"4'-0" DOLOMITIC LIMESTONE BLOCK W/
BUSH HAMMER FINISH EXPOSED
VERTICAL SURFACE
CAST-IN-PLACE CONCRETE
FOOTING
SCHEDULED PAVING;
REF: CIVIL DWGS.
FINISH GRADE PROFILE @
OPP. FACE OF WALL1'-0" 1'-4" 50'-0"
5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0"
ALIGN JOINTING WITH
PAVEMENT JOINTS
A1
P-CCPL-571 L-704
ELEVATION | WALL AT BIKE RACKS
3/8" 1'-0"
E4
L-702
T/WALL
T/STEPS
FINISH GRADE
B/WALL 1'-4"4'-0" 1'-0" 1'-4" 22'-0" 1'-4"
5'-6" 5'-6" 5'-6" 5'-6"
A4
L-703
DOLOMITIC LIMESTONE BLOCK
W/ BUSH HAMMER FINISH
EXPOSED VERTICAL SURFACE
CAST-IN-PLACE CONCRETE
FOOTING
SCHEDULED PAVING;
REF: CIVIL DWGS.
FINISH GRADE PROFILE @
OPP. FACE OF WALL
ALIGN JOINTING WITH
PAVEMENT JOINTS
D5
L-701
DETAIL
CORDIA BIKE RACK
B1
P-CCPL-572L-704
10/19/20 Daren Mindham