Loading...
HomeMy WebLinkAboutE (1)UM ACMSPINV WARNING PLACARD ADDRESS:1215 E 105TH ST,INDIANAPOLIS,IN 46280 39.939739, -86.138523 APN:291-312-107-002-000-018 CUSTOMER INFORMATION NAME:JEFF YEGERLEHNER DATE:10/8/2020 SCALE:AS NOTED REV:A AHJ:IN- CITY OF CARMEL PRN NUMBER: GRN-014487 DESIGNER /CHECKED BY: SRI/BH PAPER SIZE:17"X11" UTILITY:DUKE ENERGY WARNING PLACARDS PL-1 ! A V 15 480 400RATED MAXIMUM POWER- POINT VOLTAGE(Vmp) MAXIMUM SYSTEM VOLTAGE(Voc) MAXIMUM CIRCUIT CURRENT(Isc) RATED MAXIMUM POWER- POINT CURRENT(Imp) INVERTER 1 WARNING CAUTION: SOLAR CIRCUIT CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(7) [ Not Required if Panel board is rated not less than sum of ampere ratings of all overcurrent devices supplying it] ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION DC DISCONNECT,INVERTER [PER CODE: NEC 690.35(F)] [To be used when inverter is ungrounded] WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION CONDUIT, COMBINER BOX [PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4)] WARNING-Electric Shock Hazard No User Serviceable Parts inside Contact authorized service provide for assistance LABEL LOCATION INVERTER, JUNCTION BOXES(ROOF), AC DISCONNECT [PER CODE: NEC 690.13.G.3 & NEC 690.13.G.4] LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION [PER CODE: NEC690.13(B)] LABEL LOCATION AC DISCONNECT , POINT OF INTERCONNECTION [PER CODE: NEC 690.54] LABEL LOCATION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES. (PER CODE: IFC605.11.1.4) LABEL LOCATION POINT OF INTERCONNECTION [PER CODE: NEC705.12(D)(4)] ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: NEC 690.17(E)] DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: NEC 690.17(E)] LABEL LOCATION WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 38" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN THE MAIN SERVICE DISCONNECT,PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERATED WITH THE SERVICE PANEL CLOSED. (PWER CODE: NEC690.15 ,690.13(B)) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ! ! ! SOLAR DISCONNECT V A 9.60 LABEL LOCATION DC DISCONNECT[PER CODE: NEC690.14(C)(2)] WARNING! WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER-CURRENT DEVICE RATED AC OPERATING CURRENT AC NOMINAL OPERATING VOLTAGE 32.00 240 AMPS AC VAC PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL LOCATION AC DISCONNECT , DC DISCONNECT,POINT OF INTERCONNECTION (PER CODE: NEC690.56(C)) ! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN !WARNING: (E) MAIN SERVICE PANEL(INTERIOR) SOLAR PHOTOVOLTAIC ARRAYS ON ROOF (E) UTILITY METER(EXTERIOR) ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE. FASTENERS APPROVED BY THE LOCAL JURISDICTION (N) PV INVERTER (EXTERIOR) (N) AC DISCONNECT (EXTERIOR) HOUSE-2 HOUSE-1 10/21/20