HomeMy WebLinkAboutSPP010.0UMACMSPINVVICINITY MAP
ADDRESS:1215 E 105TH
ST,INDIANAPOLIS,IN 46280
39.939739, -86.138523
APN:291-312-107-002-000-018
CUSTOMER INFORMATION
NAME:JEFF YEGERLEHNER
DATE:10/8/2020
SCALE:AS NOTED REV:A
AHJ:IN- CITY OF CARMEL
PRN NUMBER:GRN-014487
DESIGNER /CHECKED
BY:SRI/BH PAPER SIZE:17"X11"
SCOPE OF WORK
GENERAL SYSTEM INFORMATION:
SYSTEM SIZE:
3840W DC, 7600W AC
MODULES:
(12)HANWHA Q.PEAK DUO BLK-G5 320W
INVERTER:
(1)SOLAREDGE TECHNOLOGIES SE7600H-US(240V)
OPTIMIZER:
(12)SOLAREDGE P340 POWER OPTIMIZER
SHEET CATALOG
INDEX NO.DESCRIPTION
T-1 COVER PAGE-1
T-2 COVER PAGE-2
M-1 MOUNTING DETAIL
M-2 STRUCTURAL DETAIL
E-1 SINGLE LINE DIAGRAM
PL-1 WARNING PLACARDS
SS SPEC SHEET(S)
SITE PLAN LAYOUT
·ELECTRIC CODE:NEC 2017
·FIRE CODE:IFC 2018
·BUILDING CODE:IBC 2018
·RESIDENTIAL CODE:IRC 2018
APPLICABLE CODES
JEFF YEGERLEHNER - 3.840kW DC, 7.600kW AC
COVER PAGE-1
T-1
SCALE:1/16" = 1'-0"
1.MODULES ARE LISTED UNDER UL 1703 AND
CONFORM TO THE STANDARDS.
2.INVERTERS ARE LISTED UNDER UL 1741 AND
CONFORM TO THE STANDARDS.
3.DRAWINGS ARE DIAGRAMMATIC, INDICATING
GENERAL ARRANGEMENT OF THE PV SYSTEM AND
THE ACTUAL SITE CONDITION MIGHT VARY.
4.WORKING CLEARANCES AROUND THE NEW PV
ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN
ACCORDANCE WITH NEC 110.26.
5.ALL GROUND WIRING CONNECTED TO THE MAIN
SERVICE GROUNDING IN MAIN SERVICE PANEL/
SERVICE EQUIPMENT.
6.ALL CONDUCTORS SHALL BE 600V, 75°C
STANDARD COPPER UNLESS OTHERWISE NOTED.
7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE
FOR INSPECTION IN COMPLIANCE WITH OSHA
REGULATIONS.
8.THE SYSTEM WILL NOT BE INTERCONNECTED BY
THE CONTRACTOR UNTIL APPROVAL FROM THE
LOCAL JURISDICTION AND/OR THE UTILITY.
9.ROOF ACCESS POINT SHALL BE LOCATED IN
AREAS THAT DO NOT REQUIRE THE PLACEMENT
OF GROUND LADDERS OVER OPENINGS SUCH AS
WINDOWS OR DOORS, AND LOCATED AT STRONG
POINTS OF BUILDING CONSTRUCTION WHERE THE
ACCESS POINT DOES NOT CONFLICT WITH
OVERHEAD OBSTRUCTIONS SUCH AS TREES,
WIRES OR SIGNS.
10.PV ARRAY COMBINER/JUNCTION BOX
PROVIDES TRANSITION FROM ARRAY WIRING TO
CONDUIT WIRING
GENERAL NOTES
(N) PV INVERTER (EXTERIOR)
PHOTOVOLTAIC ARRAY ON THE ROOF
(E) UTILITY METER (EXTERIOR)
(N) AC DISCONNECT (EXTERIOR)
10' APPROX DC TRENCHED
CONDUIT RUN
(E) MAIN SERVICE PANEL(INTERIOR)
UTILITY:DUKE ENERGY
NOTE: PV SYSTEM TO BE INSTALLED ON
DETACHED NON-HABITABLE STRUCTURE.
HOUSE-2
HOUSE-1