HomeMy WebLinkAbout42230008 - GR2 52 - Energy CertificateIndiana 2�2� Perfarman�e �ompliance
Praperty
568 LAGERFIELD DRIVE
CARMEL, IN 4fi032
Madel: 98D0 GDMEZ 5L6 6D3 9PL
Community: GRAMERCY
909aAVIN GRAMERCY 568
LAGERFIELD DRIVE-98Q0 GOMEZ
Performance-based compliance passes by 11.7°'0
Air Leakage Testing
Area-weighted average fenestration SHGC
Area-weighted a�erage fenestration Ll-Factor
Annual Energy Cost
Design
Heating
Cooling
Water Heating
Mechanical Ventilatian
5ubTotal - Used to determine �omplian�e
Lights & Appliances wlout Ventilation
�nsite generation
Total
Indiana 2020 Performance
$838
$135
$324
$19
$1,31fi
$488
$0
$1,803
Inspe�tion 5tatus
Results are projected
This report is based an a proposed design and does not confirm field enforcement of design elements.
Requirements
�
�
�
�
�
�
�
�
11D5
11 D2.4.12
11 D2.5
11 D2.5
11D4.1 Lighting Equipment Efficiency
f�landatory Checklist �'�andatory code requirements that are not
checked by Ekotrope must be met.
11D3.6 Mechanical Ventilation Rate
1103.6.1 hlechanical Ventilation Efficacy
a Build
Home 5enrices
ENVIRCIN�IhENTSFOR J,�, f�
As aesigned
$713
$114
$324
$9
$1,161
$488
$0
$1,fi49
Air sealing is 4.16 AGH at 50 Pa. It must not exceed 5.0� ACH at 5a Pa.
Design exceeds requirements far Indiana 202D Performance compliance by 'I'1.7°/0.
As a 3rd party extension of the code jurisdi�tion utilizing these reports, I certify that this energy code complian�e document has been created in accordan�e with the requirements of
Chapter 4 of the adopted Intemational Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certiTy that the building design des�ribed herein is consistent with
the building plans, specifications, and other �al�ulations submitted �tiith the permit application. If rating is Confirmed, I �ertiTy that the address referenced abo�e has been
inspected.+tested and that the mandatory pro�isions of the IECC have 6een installed to meet or ex�eed the intent of the IECC or will be verified as such by another party.
Name
Organizatian
❑rganixatian
TopBuild Home 5ervi�es, I
Eric Bjerre
6uilder
QAVIQ 1NEEKLEY
HDMES
Eric 8jerre
TapBuild Home 5eruices. In�
Signature: ��'�'G ����
❑igitally sig��ed: 61�6!2D at 10:48 Af�9
Ekotrope RATER - Vers�on 3.2.3.247�
Indiana 202� Perforinance compliance results calculated using Ekotrope RATER's energ}� and code compliance algorithm, including appropriate amendments.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are 6ased on data entered 6y Ekotrope users.
Ekotrope disclaims all lia6ility for the information shown on this report.
5�8 LACERFIELD DRIVE
Ceiling Attic, R-38
Abawe Grade Walls R-22
Foundation Walls N!A
Framed Floor R-3�
Slab R-�.� Perimeter, R-1 D.0
Under
Ilnfiltration 1.37 ELAI 100 s.f. Shell Area
Window U-Value: fl.34, SHGC: 0.31
Building Features
Duct 5upply R-6.0, Return R-G.0
Duct Leakage ta Outside 3 CFM251 10� ft2
Tatal auct Leakage 4 CFM251 100 ft2 (Past-Canstructiony
Heating Furnace • IVatural Gas • 93 AFUE
Cooling Air Conditianer • Electri� • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3ro party ext�r7sion of tne code junsd�ci�on ut�lizir7g these reports, I cert�fy that ihis energy code can7pliar7ce documeryt has been created in accoraance �;rith the req�ire��erts of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consiste�t �;:ith :�e
building plans. specifications, and other calculations submitted with the permit application. If rating is Confrmed: I certiTy that the address referenced above has been inspected.+tested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent ofthe IEGC or vrill be verifed as such by : neth�r partV.
Name� Eric Bjerre Si�nature: "�'�'� ����
Organization: TapBuild Hom�e Services. Inc. Digitally signed: 6f2fi120 at 1 D:48 AM
o rope - Version 3.2.3.2470
Irdiara 2C2ii Certiicate cam��iance results calculated using Eko�rape 4.ATER's energy and code complia�c� �Inari:lim. including a���opriate ainerdme�ts
E4::�tr:��e R=.TER is a RESNETHcc-edited HERS Rat rg Tool. =.1 resul°s are based on d.=.:._. �n � a: :�: EF:otrope �sers.
-E:o�r��:e : a=1a -is all lial: :.: i� t a in-c ma:ic� a�o::n o� 1� a r=��c �.
CARM E L, 1 N 4G�32
Builder: ❑AVID WEEKLEY H�MES
Model: 98a� GONIEZ 5L6 6D3 9PL RR Cammunity: GRAIVIERCY
This repart is based an a propased design and does nat confirm field enfar�ement �f design elements.
Energy �ode Inspectian Checklist
Property ❑rganixatian
568 LAGERFIELD DRIVE TopBuild Home 5ervi�es, I
CARMEL, IN 4fi032 Eric Bjerre
Madel: 98D0 GDMEZ 5L6 6D3 9PL
Community: GRAMERCY 6uilder
QAVIQ 1NEEKLEY
909aAVIN GRAMERCY 568 HDMES
LAGERFIELD DRIVE-98Q0 GOMEZ
�eneral Building Infvrmatian
Canditioned Area �sq ft}
Canditioned Valume (�ubic ft)
Insulated Shell Area (sq ft�
1,694
17,985
5,DD2.8
Inspe�tion 5tatus
Results are projected
a Build
Home 5enrices
ENVIRCIN�IhENTSFOR J,�, f�
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will �hange in the field frorn what has been modeled. The inspection pro�ess should identify any �hanges and ensure
that the home cantinues to meet the applicable energy code.
51ab
� Name: SLAB(605 s.f., 110.1 ft. exterior perimetery
R-0 perimeter insulation, R-1 D under slab insulatian.
Framed Flvar
� Name: FDA �36 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulatian Grade: I
� Name: FDG (450 s.f.}
R-0 continuous insulation, R-30 cavity insulatian
Insulation Grade: I
Fvundatian Wall
Nane Present
Abvve �rade Wall
� Name: AMB [2,4D1.7 s.f.}
R-3 continuous insulati�n, R-19 cavity insulation
Insulation Grade: I
� Name: GAR (198 s.f.}
R-0 continuous insulation, R-19 cavity insulatian
Insulati�n Grade: I
Energy �ode Inspectian Checklist
Property ❑rganixatian
568 LAGERFIELD DRIVE TopBuild Home 5ervi�es, I
CARMEL, IN 4fi032 Eric Bjerre
Madel: 98D0 GDMEZ 5L6 6D3 9PL
Community: GRAMERCY 6uilder
QAVIQ 1NEEKLEY
909aAVIN GRAMERCY 568 HDMES
LAGERFIELD DRIVE-98Q0 GOMEZ
� Name: ATT � 13 s.f. y
R-0.5 continuous insulation, R-19 �avity insulation
Insulation Grade: I
Rim Jaist
� Name: AMB [191.1 s.f.}
R: 22.00
� Name: ATT � 17 s.f. }
R: 19.00
Ceiling 1 Rvvf
� Name: FLAT �1,091 s.f.y
R-25 continuous insulation, R-13 cavity insulation
Insulation Grade: I
❑paque Daar
� Name: FR�NT (24 s.f.}
U: 0.227
� Name: GAR (17.8 s.f.}
U: 0.227
Glazing
Inspe�tion 5tatus
Results are projected
� Name: FR�NT 1 ST (40 s.f.), U: 0.340, SHGC: 0.31, �rientatian: NDRTH_WEST
� Name: FRONT 1 ST (18 s.f.), U: 0.340, SHGC: 0.31, �rientatian: N�RTH_WEST
� Name: LEFT 1 ST (20 s.f.), U: 0.340, SHGC: 0.31, �rientatian: N�RTH_EAST
� Name: LEFT 15T (18 s.f.), U: 0.340, SHGC: 0.31, �rientation: N�RTH_EAST
� Name: FR�NT 2ND �40 s.f.}, lJ: 0.340, SHGC: 0.31, ❑rientation: N�RTH_WEST
a Build
Home 5enrices
ENVIRCIN�IhENTSFOR J,�, f�
2
Energy �ode Inspectian Checklist
Property ❑rganixatian
568 LAGERFIELD DRIVE TopBuild Home 5ervi�es, I
CARMEL, IN 4fi032 Eric Bjerre
Madel: 98D0 GDMEZ 5L6 6D3 9PL
Community: GRAMERCY 6uilder
QAVIQ 1NEEKLEY
Inspe�tion 5tatus
Results are projected
909aAVIN GRAMERCY 568 HDMES
LAGERFIELD DRIVE-98Q0 GOMEZ
� Name: FR�NT 2ND �30 s.f.}, lJ: 0.340, SHGC: 0.31, ❑rientation: N�RTH_WEST
� Name: LEFT 2ND �12.5 s.f.), lJ: 0.34D, SHGC: 0.31, �rientation: N�RTH_EAST
� Name: LEFT 21VD FR�R (21.4 s.f.�, lJ: a.34�, SHGC: D.31, ❑rientation: N�RTH_EAST
� Name: LEFT 2ND �12.5 s.f.}, lJ: 0.34D, SHGC: 0.31, �rientation: NDRTH_EAST
� Name: LEFT 2ND �12.5 s.f.), lJ: 0.34D, SHGC: �.31, �rientation: NDRTH_EAST
� Name: LEFT 2ND �12.5 s.f.), lJ: 0.34D, SHGC: 0.31, �rientation: NDRTH_EAST
!!!
�
�
Name: LEFT 2ND �12.5 s.f.), lJ: 0.34D, SHGC: D.31, �rientation: NORTH_EAST
Name: BAGK 2ND �3G s.f.}, U: 0.34a, SHGC: Q.31, ❑rientation: S�IJTH_EAST
Name: RIGHT 2Na (9 s.f.}, U: 0.340, SHGC: 0.31, �rientatian: SDUTH_WEST
5kylight
Nane Present
Mechanical Ventilativn
� Mechanical ventilatian system rated for, and capable af, providing cantinuous ventilation.
System shall include autamatic timing controls.
System type: Air Cycler, G hrslday, 67.54 lNatts
Mechanical Equiprnent
� Fuel-fired air distribution {1 }• Natural Gas • 10D°�o Heating Load [�7a 93 AFUE
� Air conditioner (2} • Electric • 1 DD°Io Caoling Load �a 13 SEER
� Water Heating �3} • Electric • 100°Io Hot UVater Load a� 0.93 Energy Factor
a Build
Home 5enrices
ENVIRCIN�IhENTSFOR J,�, f�
3
Energy �ode Inspectian Checklist
Property ❑rganixatian
568 LAGERFIELD DRIVE TopBuild Home 5ervi�es, I
CARMEL, IN 4fi032 Eric Bjerre
Madel: 98D0 GDMEZ 5L6 6D3 9PL
Community: GRAMERCY 6uilder
QAVIQ 1NEEKLEY
909aAVIN GRAMERCY 568 HDMES
LAGERFIELD DRIVE-98Q0 GOMEZ
Air Leakage Cvntrvl
Inspe�tion 5tatus
Results are projected
� Test Status: 6lower-door tested
House is air-sealed as to achieve 1,246 CFM�O �4.16 AGH50] or less at final blower-door test.
Infiltration Requirements for IECC in Climate Zone 5
2a09 IECC Infiltration limit for the design hame is 7 ACHS�.
2a12 IECC Infiltration limit for the design hame is 3 ACHS�.
2a15 IECC Infiltration limit for the design hame is 3 ACHS�.
2�18 IECC Infiltration limit for the design home is 3 ACH��.
Duct Leakage
Duct 5ystem 1
NOT entirely within ��nditioned spa�e, testing required
Leakage to ❑utside specified as: 3 CFM251 1 DD ftz
Total Leakage spe�ified as: 4 CFM251 1D� ft2 �Post-Constru�tion}
Duct Leakage Cvde Requirements fvr IECC
2009 IECC:
Postconstruction Leakage Test: auct Leakage ta Dutdaars �= 8 CFM251 100 sq ft CFR.
Rough in Test with AHLl: Total auct Leakage �= 6 CFM251 100 sq ft CFA.
Rough in Test without AHU: Tatal Duct Leakage �= 4 CFM25 ! 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstructian Leakage Test: Tatal au�t Leaka�e �= 4 CFM25 J 100 sq ft CFA.
Rough in Test with AHU: Tatal auct Leakage �= 4 CFM25 I 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage r= 3 CFM25 ! 100 sq ft CFA.
2015 Performance Path �Cost Campliance}:
a Build
Home 5enrices
ENVIRCIN�IhENTSFOR J,�, f�
Leakage testing is required UNLESS all ducts and air handlers are lo�ated entirely within the thermal envelope.
There is no passlfail threshold for duct leakage on the performance path.
4
Energy �ode Inspectian Checklist
Property ❑rganixatian
568 LAGERFIELD DRIVE TopBuild Home 5ervi�es, I
CARMEL, IN 4fi032 Eric Bjerre
Madel: 98D0 GDMEZ 5L6 6D3 9PL
Community: GRAMERCY 6uilder
QAVIQ 1NEEKLEY
909aAVIN GRAMERCY 568 HDMES
LAGERFIELD DRIVE-98Q0 GOMEZ
Inspe�tion 5tatus
Results are projected
Praject Nates
ORG ID: 48
ACC#: 909DAVIN
BUILDER NAME: DAVID WEEKLEY H�MES
PRQ]ECT ID: 59945
SUBDIVISI�N: GRAMERCY
PLAN ID: 857140
PLAN NAME: 55$ LAGERFIELD DRIVE-9$00 G�MEZ SLB BD3 9PL RR-CC
REVISIQN DATE: 05J25�2020
PR�GRAM: EFL�P�3Y�100��CH5:N❑
CREATED ❑N: 05�25J2020
a Build
Home 5enrices
ENVIRCIN�IhENTSFOR J,�, f�
5