HomeMy WebLinkAboutA2.1_ReflectedCeilingS ND SSSND SNSNSNSNSN3SN310' A.F.F.
10' A.F.F.
10' A.F.F.
10' A.F.F.10' A.F.F. 10' A.F.F.SN3DSN3D
10' A.F.F. 10' A.F.F.10' A.F.F. 10' A.F.F. 10' A.F.F.SN3D
SN3SN3SN3D SN3D SN3D
SN3SN3SNDSN115
UTILITY
116
UNISEX
RESTROOM
114
X-RAY
105
FAMILY
CONSULTATION
110
TREATMENT
ROOM 4
108
TREATMENT
ROOM 3
106
TREATMENT
ROOM 2
104
TREATMENT
ROOM 1
111
CONSULT
109
CONSULT
107
CONSULT
101
OFFICE
100
RECEPTION/
WAITING
102
HALL
113
HALL
112
UTILITY/
STORAGE
103
DAILY
ASSESSMENT
GFCI
+60"A.F.F.
GFCI
+44"
DISCONNECT SWITCH. REFER TO
X-RAY EQUIPMENT DRAWINGS
FOR ELECTRICAL REQUIREMENTS.
212" CONDUIT AT FLOOR
HEIGHT TO PASS CABLING
THROUGH OPERATOR WALL
NETWORK DROP AND DEDICATED
DUPLEX OUTLET FOR DIGITAL IMAGE
PROCESSING PC. INSTALL UNDER
COUNTER AT OUTLET HEIGHT.
EXISTING 400 AMP
ELECTRICAL PANEL
RECESSED IN WALL
FOR TV MOUNT
NORTH 1/4" = 1'-0"
Power and Data Plan Reflected Ceiling and Power PlansA2.1TMK TSRCP NOTES
GENERAL NOTES
QUANTUMARCHITECTUREPO Box 56032 Indianapolis, IN 46256317-413-9497 www.q-architecture.comHOPE CHIROPRACTIC4335 West 106th Street, Ste 1000Carmel IN 460329-24-202020008OPEN TO STRUCTURE ABOVE. CLEAN STRUCTURE AND EQUIPMENT
AND PAINT WITH DRYFALL PAINT, PT3. SEE FINISH SCHEDULE.
ACOUSTIC CEILING TILE AT 9'-0" A.F.F. PROVIDE BATT INSULATION
ABOVE CEILING FOR SOUND ATTENUATION.
EXISTING DUCTWORK TO REMAIN.
CLOSE OFF EXISTING DIFFUSER IN BOTTOM OF DUCT.
NEW LAY-IN SUPPLY DIFFUSER AND DUCT. TIE INTO EXISTING HVAC
SYSTEM.
1
2
A. SEE SHEET A7.1 FOR FINISH SCHEDULE.
3
4
NORTH 1/4" = 1'-0"
Reflected Ceiling Plan
5
POWER PLAN LEGEND
1
11 1 1
1
1
1
2 2 2 2
2
3 3
3
3
44
5
5 5 5 5
POC EXTEND DUCT
TOWARD
STOREFRONT
NEW SIDE DIFFUSER
(TYPICAL OF 6)
REMOVE EXISTING 24"x24"
DIFFUSER. EXTEND DUCT
TO NEW LAY-IN DIFFUSER.
REMOVE EXISTING
24"x24" DIFFUSER.
REPLACE CEILING DIFFUSER
AND RECONNECT TO
EXISTING DUCT
REPLACE CEILING DIFFUSER
AND RECONNECT TO
EXISTING DUCT S
RCP LEGEND
EXISTING FLUORESCENT LIGHT FIXTURE
NEW 1x4 L.E.D. SURFACE MOUNT DIMMABLE LIGHT
FIXTURE
NEW 2x4 L.E.D. LAY-IN LIGHT FIXTURE
4' LONG TRACK LIGHT WITH 4 TRACK HEADS.
MOUNTING HEIGHT AS SHOWN ON PLAN.
DIMMABLE L.E.D PENDANT LIGHT FIXTURE.
MOUNTING HEIGHT T.B.D.
EXISTING EXIT SIGN
EXISTING EMERGENCY LIGHT
LIGHT SWITCH: 'N' INDICATES NEW SWITCH, '3'
INDICATES 3-WAY SWITCH, 'D' INDICATES DIMMER
SWITCH
2x2 LAY-IN SUPPLY DIFFUSER
EXISTING DUPLEX RECEPTACLE
NEW DUPLEX RECEPTACLE
NEW 22V RECEPTACLE FOR CLOTHES DRYER
NEW PHONE/DATA BOX WITH CONDUIT TO ABOVE CEILING WITH
PULL STRING. COORDINATE PLATE WITH OWNER.
NEW DISCONNECT SWITCH FOR X-RAY EQUIPMENT. SEE X-RAY
DRAWING SUBMITTAL FOR MORE REQUIREMENTS.
NOTE:
REUSE SPARE CIRCUITS IN EXISTING 400 AMP SERVICE FOR
NEW OUTLETS AND LIGHT FIXTURES AS REQUIRED. ALL NEW
LIGHTING TO BE LED WHICH REPLACES FLUORESCENT AND
METAL HALIDE GENERAL LIGHTING FIXTURES, REDUCING
OVERALL ELECTRICAL LOAD.
10/23/20