Loading...
HomeMy WebLinkAboutGD1.0_Demo Plan-Demo PlanPROPOSED 50' DRAINAGE& UTILITY EASEMENT6 12 19 12 21 12 12 1 1 1 12 13 13 13 1 13 121 2 312 112 22 1422 2 1 2 12 3 1 1 1 1 1 2 3 1 5 137 8 8 2 10 7 9 20 18 16 17 17 15 23 23 23 24 24 24 24 24 4 15 15 GENERAL NOTES 1. SEE SHEET G0.1 FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS. 2. REFER TO SURVEY SHEET FOR BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION. 3. REFER TO LANDSCAPE PLANS FOR PLANTINGS. 3. SEE SHEET SU2.3 FOR SANITARY PIPE INSTALLATION DETAILS. 4. SEE SHEET SU3.1 FOR WATER LINE INSTALLATION DETAILS. KEYNOTES REMOVE CHAIN LINK FENCE REMOVE CONCRETE REMOVE DUGOUT AND FOUNDATIONS LIFT STATION TO BE REMOVED REMOVE BUILDING REMOVE STEEL FRAME STRUCTURE REMOVE SANITARY DUCTILE IRON PIPE REMOVE SANITARY SEWER CLEANOUT - FIELD VERIFY ELECTRIC MANHOLE TO REMAIN - COORDINATE NEW SERVICE ROUTING WITH MEP PLANS REMOVE ELECTRIC LINE REMOVE IRRIGATION WATER LINE LIGHT POLE TO BE REMOVED AND THEN REINSTALLED - COORDINATE WITH MEP PLANS REMOVE IRRIGATION BOX REMOVE BLEACHERS AND CONCRETE PAD REMOVE SIGN REMOVE GATE REMOVE TREES SAWCUT EXISTING ASPHALT PAVEMENT REMOVE SCOREBOARD AND ELECTRIC SERVICE LINE REMOVE STORM SEWER STRUCTURE REMOVE FLAGPOLE AND FOUNDATION - COORDINATE WITH OWNER REMOVE BACKSTOP EXISTING 2" FORCE MAIN TO REMAIN - PROTECT THROUGHOUT CONSTRUCTION EXISTING STORM SEWER/STRUCTURE TO REMAIN - PROTECT THROUGHOUT CONSTRUCTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what'sbelow. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! LEGEND CLEANOUT SANITARY SEWER STORM SEWER MANHOLE / INLET WATER LINE GUTTER ELEV. TOP/CURB ELEV.600.50 600.00 650.00 SPOT ELEVATION CURB SPOT ELEVATION MATCH EXISTING GRADEMEG SITE ADDRESS: 5459 EAST MAIN STREET CARMEL, IN. 46033 DEPARTMENT OF PLANNING & DEVELOPMENT ADDRESS: 1100 WEST OAK STREET ZIONSVILLE, IN. 46225 SURVEY INFORMATION FLOOD INFORMATION: The described real estate lies within Zone X (Unshaded) as plotted by scale on the Federal Emergency Management Agency, National Flood Insurance Program, FIRM Flood Insurance Rate Map for Community Number 180081, Map Number 18057C0227G, effective November 19, 2014. SEE SURVEY SHEETS (4 TOTAL) BY DLDS DATED APRIL 18, 2016 FOR SURVEY INFORMATION. STORM SEWER PIPE AND STRUCTURE NOTE: SEE SHEET SU1.1 FOR STORM STRUCTURE TABLE. SEE SHEET SU1.3 FOR STORM PROFILE. SITE DEMO PLAN SCALE: 1"= 40' N 40 1200 40 80 PLANNORTHN WS ECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT CONSULTANT 6/13/2019 3:21:38 PM\\data1\citrixprofiles$\amiller\My Documents\218052.00_ARCH_amiller.rvtPROJECT NUMBER: 2019199.00 INDOOR FACILITY AT BADGER FIELDS CLAY TOWNSHIP 5459 E MAIN STREET CARMEL, INDIANA PROJECT ISSUE DATE: August 23, 2019 DRAWN BY: MTP REV. NO. DESCRIPTION DATE 11300453 SOI STATE OF ORPFE S NEER N LA E N G IANAINIDER DAHC IIGS No. TERE DA CNIK.N DTAC COMMENTS 09/06/20191 TAC COMMENTS 12/03/20192 TAC COMMENTS 01/10/20203 DEMOLITION PLAN GD1.0 10/22/20