HomeMy WebLinkAboutGD1.0_Demo Plan-Demo PlanPROPOSED 50' DRAINAGE& UTILITY EASEMENT6
12
19
12
21
12
12
1 1
1
12
13
13
13
1
13
121
2
312 112
22
1422
2
1
2
12
3
1
1
1
1 1 2
3 1
5
137
8
8
2
10
7 9
20
18
16
17 17
15
23
23
23
24
24
24
24
24
4
15
15
GENERAL NOTES
1. SEE SHEET G0.1 FOR GENERAL NOTES, LEGEND AND
ABBREVIATIONS.
2. REFER TO SURVEY SHEET FOR BOUNDARY AND TOPOGRAPHIC
SURVEY INFORMATION.
3. REFER TO LANDSCAPE PLANS FOR PLANTINGS.
3. SEE SHEET SU2.3 FOR SANITARY PIPE INSTALLATION DETAILS.
4. SEE SHEET SU3.1 FOR WATER LINE INSTALLATION DETAILS.
KEYNOTES
REMOVE CHAIN LINK FENCE
REMOVE CONCRETE
REMOVE DUGOUT AND FOUNDATIONS
LIFT STATION TO BE REMOVED
REMOVE BUILDING
REMOVE STEEL FRAME STRUCTURE
REMOVE SANITARY DUCTILE IRON PIPE
REMOVE SANITARY SEWER CLEANOUT - FIELD VERIFY
ELECTRIC MANHOLE TO REMAIN - COORDINATE NEW SERVICE ROUTING WITH
MEP PLANS
REMOVE ELECTRIC LINE
REMOVE IRRIGATION WATER LINE
LIGHT POLE TO BE REMOVED AND THEN REINSTALLED - COORDINATE WITH
MEP PLANS
REMOVE IRRIGATION BOX
REMOVE BLEACHERS AND CONCRETE PAD
REMOVE SIGN
REMOVE GATE
REMOVE TREES
SAWCUT EXISTING ASPHALT PAVEMENT
REMOVE SCOREBOARD AND ELECTRIC SERVICE LINE
REMOVE STORM SEWER STRUCTURE
REMOVE FLAGPOLE AND FOUNDATION - COORDINATE WITH OWNER
REMOVE BACKSTOP
EXISTING 2" FORCE MAIN TO REMAIN - PROTECT THROUGHOUT CONSTRUCTION
EXISTING STORM SEWER/STRUCTURE TO REMAIN - PROTECT THROUGHOUT
CONSTRUCTION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY
ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR
WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR
EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES
SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND
WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE
OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY
ALL CONSTRUCTION.
THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES,
SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND
CAUTION !!
Know what'sbelow.
before you dig.Call
R
Call 811 or 1-800-382-5544 Before You Begin Any Digging Project.
Call 48 hours or 2 working days before you dig.
It's Fast, It's Easy and It's the Law in the state of Indiana!
LEGEND
CLEANOUT
SANITARY SEWER
STORM SEWER
MANHOLE / INLET
WATER LINE
GUTTER ELEV.
TOP/CURB ELEV.600.50
600.00
650.00 SPOT ELEVATION
CURB SPOT ELEVATION
MATCH EXISTING GRADEMEG
SITE ADDRESS:
5459 EAST MAIN STREET
CARMEL, IN. 46033
DEPARTMENT OF PLANNING &
DEVELOPMENT ADDRESS:
1100 WEST OAK STREET
ZIONSVILLE, IN. 46225
SURVEY INFORMATION
FLOOD INFORMATION:
The described real estate lies within Zone X (Unshaded) as
plotted by scale on the Federal Emergency Management
Agency, National Flood Insurance Program, FIRM Flood
Insurance Rate Map for Community Number 180081, Map
Number 18057C0227G, effective November 19, 2014.
SEE SURVEY SHEETS (4 TOTAL) BY DLDS
DATED APRIL 18, 2016 FOR SURVEY
INFORMATION.
STORM SEWER PIPE AND STRUCTURE
NOTE:
SEE SHEET SU1.1 FOR STORM STRUCTURE
TABLE. SEE SHEET SU1.3 FOR STORM PROFILE.
SITE DEMO PLAN
SCALE: 1"= 40' N
40 1200 40 80 PLANNORTHN
WS ECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC.
WWW.FHAI.COM
ARCHITECT
CONSULTANT
6/13/2019 3:21:38 PM\\data1\citrixprofiles$\amiller\My Documents\218052.00_ARCH_amiller.rvtPROJECT NUMBER: 2019199.00
INDOOR FACILITY
AT BADGER
FIELDS
CLAY TOWNSHIP
5459 E MAIN STREET
CARMEL, INDIANA
PROJECT ISSUE DATE: August 23, 2019
DRAWN BY: MTP
REV.
NO. DESCRIPTION DATE
11300453
SOI
STATE OF
ORPFE
S NEER N LA E N G IANAINIDER
DAHC IIGS
No.
TERE
DA
CNIK.N
DTAC COMMENTS 09/06/20191
TAC COMMENTS 12/03/20192
TAC COMMENTS 01/10/20203
DEMOLITION PLAN
GD1.0
10/22/20