Loading...
HomeMy WebLinkAboutSU4_Site Utility PlanGENERAL NOTES 1. SEE SHEET G1.0 FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS. 2. REFER TO SURVEY SHEET FOR BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION. 3. REFER TO LANDSCAPE PLANS FOR PLANTINGS. 4. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE OWNER. . 5. SOUTHERN IRRIGATION WELL TO REMAIN ACTIVE INCLUDING PUMPS, PRESSURE TANKS, BACK-FLOW PREVENTER, AND ELECTRICAL FEEDS. KEYNOTES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 CONNECT TO EXISTING WATER LINE OFFSITE. PROVIDE TAP ON EXISTING WATER LINE WITH GATE VALVE. CONTRACTOR SHALL CONTACT LOCAL WATER UTILITY NOT LESS THAN 72 HOURS BEFORE START OF CONSTRUCTION OF WATER LINE. SEE SHEET SU1.3. C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2 97' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2 53' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2 590' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2 344' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2 577' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2 348' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2 PIPE RESTRAINT - SEE DETAIL CW10 ON SHEET SU4.2 RESTRAINTS SHALL COMPLY WITH CITY OF CARMEL STANDARDS. FIRE DEPARTMENT CONNECTION - SEE DETAILS A ON SHEET SU4.1 FIRE HYDRANT - SEE DETAIL CW8 ON SHEET SU4.2 POST INDICATOR VALVE - SEE DETAIL A ON SHEET SU4.2 GAS LINE - SEE MEP PLANS FOR SIZE AND ADDITIONAL INFORMATION GAS METER AND REGULATOR. SEE MEP PLANS FOR SIZE AND ADDITIONAL INFORMATION 40' OF 6" FIRE PROTECTION LINE - SEE DETAIL CW3 ON SHEET SU4.2 GATE VALVE ON 3" DOMESTIC WATER SERVICE LINE - SEE DETAIL B ON SHEET SU4.2 WATER LINE/SANITARY SEWER CROSSING. SEE DETAIL CS 32/SU2.3 41' OF 2" DOMESTIC WATER LINE 4' ELECTRICAL TRANSFORMER CONCRETE PAD PULL BOX - SEE ELECTRICAL PLAN NEW LIFT STATION TO BE INSTALLED - SEE SHEET SU3.1 552' OF FIRE PROTECTION TO FIRE DEPARTMENT CONNECTION - SEE DETAIL CW3 ON SHEET SU4.2 2" DOMESTIC WATER METER GATE VALVE ON 6" FIRE PROTECTION LINE - SEE DETAIL B ON SHEET SU4.2 RELOCATE EXISTING FORCE MAIN AS NEEDED RELOCATE EXISTING FIRE HYDRANT AND VALVE TO SOUTH OF THE MAIN STORM SEWER CLEANOUT - SEE DETAIL ST-4/SU2.1 DOWNSPOUT LOCATION - SEE DETAIL G ON SHEET SU2.4 24 25 26 27 28 DEX. BUILDINGEX. BUILDING4PROPOSED 50' DRAINAGE& UTILITY EASEMENTPROPOSED 50' DRAINAGE& UTILITY EASEMENTINV @ 12" CPP W = 778.30 INV @ 12" CPP E = 778.41 INV @ 24" RCP W = 778.06 INV @ 24" RCP E = 778.32 12" CMP ST-602 ST-601 ST-600 2 1 13 26 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what'sbelow. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! SITE UTILITY PLAN SCALE: 1"= 40'N 40 1200 40 80 LEGEND CLEANOUT GAS LINE STORM SEWER MANHOLE / INLET WATER LINE SANITARY SEWER LINE STORM SEWER PIPE AND STRUCTURE NOTE: SEE SHEET SU2.5 FOR STORM STRUCTURE TABLE. SITE ADDRESS: 5459 EAST MAIN STREET CARMEL, IN 46033 DEPARTMENT OF PLANNING & DEVELOPMENT ADDRESS: ONE CIVIC SQUARE CARMEL, IN 46032 SURVEY INFORMATION FLOOD INFORMATION: The described real estate lies within Zone X (Unshaded) as plotted by scale on the Federal Emergency Management Agency, National Flood Insurance Program, FIRM Flood Insurance Rate Map for Community Number 180081, Map Number 18057C0227G, effective November 19, 2014. SEE SURVEY SHEETS (4 TOTAL) BY DLDS DATED APRIL 18, 2016 FOR SURVEY INFORMATION. SITE UTILITY PLAN SU1.3 MATCH LINE - SEE SHEET SU1.2 PLANNORTHN WS ECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT CONSULTANT PROJECT NUMBER: 2019199.00 INDOOR FACILITY AT BADGER FIELDS CLAY TOWNSHIP 5459 E MAIN STREET CARMEL, INDIANA PROJECT ISSUE DATE: 06.08.2020 DRAWN BY: MTP REV. NO. DESCRIPTION DATE CONSTRUCTION DOCUMENTS PROJECT MANAGER: CNK ADDENDUM #1 6/25/2020 ADDENDUM #2 7/1/2020 ADDENDUM #3 7/8/2020 COC REVISIONS 10/5/2020 10/22/20