HomeMy WebLinkAboutSU4_Site Utility PlanGENERAL NOTES
1. SEE SHEET G1.0 FOR GENERAL NOTES, LEGEND AND
ABBREVIATIONS.
2. REFER TO SURVEY SHEET FOR BOUNDARY AND TOPOGRAPHIC
SURVEY INFORMATION.
3. REFER TO LANDSCAPE PLANS FOR PLANTINGS.
4. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE
RESPONSIBILITY OF THE OWNER. .
5. SOUTHERN IRRIGATION WELL TO REMAIN ACTIVE INCLUDING
PUMPS, PRESSURE TANKS, BACK-FLOW PREVENTER, AND
ELECTRICAL FEEDS.
KEYNOTES
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
CONNECT TO EXISTING WATER LINE OFFSITE. PROVIDE TAP ON
EXISTING WATER LINE WITH GATE VALVE. CONTRACTOR SHALL
CONTACT LOCAL WATER UTILITY NOT LESS THAN 72 HOURS
BEFORE START OF CONSTRUCTION OF WATER LINE. SEE SHEET
SU1.3.
C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2
97' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2
53' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2
590' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2
344' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2
577' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2
348' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2
PIPE RESTRAINT - SEE DETAIL CW10 ON SHEET SU4.2 RESTRAINTS
SHALL COMPLY WITH CITY OF CARMEL STANDARDS.
FIRE DEPARTMENT CONNECTION - SEE DETAILS A ON SHEET SU4.1
FIRE HYDRANT - SEE DETAIL CW8 ON SHEET SU4.2
POST INDICATOR VALVE - SEE DETAIL A ON SHEET SU4.2
GAS LINE - SEE MEP PLANS FOR SIZE AND ADDITIONAL
INFORMATION
GAS METER AND REGULATOR.
SEE MEP PLANS FOR SIZE AND ADDITIONAL INFORMATION
40' OF 6" FIRE PROTECTION LINE - SEE DETAIL CW3 ON SHEET SU4.2
GATE VALVE ON 3" DOMESTIC WATER SERVICE LINE - SEE DETAIL B
ON SHEET SU4.2
WATER LINE/SANITARY SEWER CROSSING. SEE DETAIL CS 32/SU2.3
41' OF 2" DOMESTIC WATER LINE
4' ELECTRICAL TRANSFORMER CONCRETE PAD
PULL BOX - SEE ELECTRICAL PLAN
NEW LIFT STATION TO BE INSTALLED - SEE SHEET SU3.1
552' OF FIRE PROTECTION TO FIRE DEPARTMENT CONNECTION -
SEE DETAIL CW3 ON SHEET SU4.2
2" DOMESTIC WATER METER
GATE VALVE ON 6" FIRE PROTECTION LINE - SEE DETAIL B ON
SHEET SU4.2
RELOCATE EXISTING FORCE MAIN AS NEEDED
RELOCATE EXISTING FIRE HYDRANT AND VALVE TO SOUTH OF THE
MAIN
STORM SEWER CLEANOUT - SEE DETAIL ST-4/SU2.1
DOWNSPOUT LOCATION - SEE DETAIL G ON SHEET SU2.4
24
25
26
27
28
DEX. BUILDINGEX. BUILDING4PROPOSED 50' DRAINAGE& UTILITY EASEMENTPROPOSED 50' DRAINAGE& UTILITY EASEMENTINV @ 12" CPP W = 778.30
INV @ 12" CPP E = 778.41
INV @ 24" RCP W = 778.06
INV @ 24" RCP E = 778.32
12" CMP
ST-602
ST-601
ST-600
2
1
13
26
INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY
ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR
WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR
EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES
SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND
WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE
OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY
ALL CONSTRUCTION.
THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES,
SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND
CAUTION !!
Know what'sbelow.
before you dig.Call
R
Call 811 or 1-800-382-5544 Before You Begin Any Digging Project.
Call 48 hours or 2 working days before you dig.
It's Fast, It's Easy and It's the Law in the state of Indiana!
SITE UTILITY PLAN
SCALE: 1"= 40'N
40 1200 40 80
LEGEND
CLEANOUT
GAS LINE
STORM SEWER
MANHOLE / INLET
WATER LINE
SANITARY SEWER LINE
STORM SEWER PIPE AND STRUCTURE
NOTE:
SEE SHEET SU2.5 FOR STORM STRUCTURE
TABLE.
SITE ADDRESS:
5459 EAST MAIN STREET
CARMEL, IN 46033
DEPARTMENT OF PLANNING &
DEVELOPMENT ADDRESS:
ONE CIVIC SQUARE
CARMEL, IN 46032
SURVEY INFORMATION
FLOOD INFORMATION:
The described real estate lies within Zone X (Unshaded) as
plotted by scale on the Federal Emergency Management
Agency, National Flood Insurance Program, FIRM Flood
Insurance Rate Map for Community Number 180081, Map
Number 18057C0227G, effective November 19, 2014.
SEE SURVEY SHEETS (4 TOTAL) BY DLDS
DATED APRIL 18, 2016 FOR SURVEY
INFORMATION.
SITE UTILITY PLAN
SU1.3
MATCH LINE - SEE SHEET SU1.2 PLANNORTHN
WS ECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC.
WWW.FHAI.COM
ARCHITECT
CONSULTANT
PROJECT NUMBER: 2019199.00
INDOOR FACILITY
AT BADGER
FIELDS
CLAY TOWNSHIP
5459 E MAIN STREET
CARMEL, INDIANA
PROJECT ISSUE DATE: 06.08.2020
DRAWN BY: MTP
REV.
NO. DESCRIPTION DATE
CONSTRUCTION DOCUMENTS
PROJECT MANAGER: CNK
ADDENDUM #1 6/25/2020
ADDENDUM #2 7/1/2020
ADDENDUM #3 7/8/2020
COC REVISIONS 10/5/2020
10/22/20