Loading...
HomeMy WebLinkAboutG05_G3.2_Grading PlanEast Main St. (Public)EX. BUILDINGEX. BUILDINGPROPOSED 50' DRAINAGE& UTILITY EASEMENTD 50' DRAINAGEEASEMENTINV @ 12" CPP W = 778.30 INV @ 12" CPP E = 778.41 INV @ 24" RCP W = 778.06 INV @ 24" RCP E = 778.32 12" CMP 780 781 781781 ST-600 ST-602 ST-601 782.08 MEG 781.96 781.66 781.78 780.24 780.02 782.27 782.51 MEG 782.15 783.04 783.22 MEG 782.92 784.25 784.48 MEG 784.13 782.96 783.20 MEG 782.84 781.93 782.45 781.74 783.20 MEG 783.20 MEG 783.59 MEG 783.84 MEG 783.15 784.42 784.30 786.43 786.55 MEG 788.25 MEG 788.13 783.40 783.00 783.10 783.49 785.50 MEG 785.43 780.65 783.40 778 779 780 781 782 783 784 785 784 783 782781780779781.16 781.12 779.49 779.84 779.59 779.44 781.62 781.48 GENERAL NOTES 1. SEE SHEET G0.1 FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS. 2. REFER TO SURVEY SHEET FOR BOUNDARY, TOPOGRAPHIC, AND DATUM REFERENCE SURVEY INFORMATION. 3. REFER TO LANDSCAPE PLANS FOR PLANTINGS. 3. SEE SHEET SU2.3 FOR SANITARY PIPE INSTALLATION DETAILS. 4. SEE SHEET SU3.1 FOR WATER LINE INSTALLATION DETAILS. 5. DRAINAGE SYSTEM TO BE PRIVATE. 6. FLOOD PROTECTION GRADE - THE ELEVATION OF THE REGULATORY FLOOD PLUS TWO FEET AT ANY GIVEN LOCATION IN THE SPECIAL FLOOD HAZARD AREA. 7. NAVD 88 USED FOR ELEVATIONS KEYNOTES 1 EMERGENCY SPILLWAY RIPRAP - SEE DETAIL B ON SHEET G4.4 LEGEND CLEANOUT SANITARY SEWER STORM SEWER MANHOLE / INLET WATER LINE GUTTER ELEV. TOP/CURB ELEV.600.50 600.00 650.00 SPOT ELEVATION CURB SPOT ELEVATION MATCH EXISTING GRADEMEG FLOOD INFORMATION: The described real estate lies within Zone X (Unshaded) as plotted by scale on the Federal Emergency Management Agency, National Flood Insurance Program, FIRM Flood Insurance Rate Map for Community Number 180081, Map Number 18057C0227G, effective November 19, 2014. STORM SEWER PIPE AND STRUCTURE NOTE: SEE SHEET SU2.5 FOR STORM STRUCTURE TABLE. SURVEY INFORMATION SEE SURVEY SHEETS (4 TOTAL) BY DLDS DATED APRIL 18, 2016 FOR SURVEY INFORMATION. INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what'sbelow. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! SITE ADDRESS: 5459 EAST MAIN STREET CARMEL, IN 46033 DEPARTMENT OF PLANNING & DEVELOPMENT ADDRESS: ONE CIVIC SQUARE CARMEL, IN 46032 GRADING PLAN SCALE: 1"= 30'N 30 900 30 60 PLANNORTHN WS ECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT CONSULTANT PROJECT NUMBER: 2019199.00 INDOOR FACILITY AT BADGER FIELDS CLAY TOWNSHIP 5459 E MAIN STREET CARMEL, INDIANA PROJECT ISSUE DATE: 06.08.2020 DRAWN BY: MTP REV. NO. DESCRIPTION DATE 11300453 SOI STATE OF ORPFE S NEER N LA E N G IANAINIDERDAHC IIGS No. TERE DA C NIK.N DCONSTRUCTION DOCUMENTS PROJECT MANAGER: CNK GRADING PLAN G3.2 FLOOD PROTECTION GRADE NOTE: SEE SHEET G3.2 EMERGENCY FLOOD ROUTING PLAN FOR FLOOD PROTECTION GRADE AND SHADING OF SITE WITH THE GRADE. 10/22/20