Loading...
HomeMy WebLinkAboutG06_G3.4_Pad Grading PlanPROPOSED 50' DRAINAGE& UTILITY EASEMENTFP FP FPFPFPST-203 ST-104 ST-BMP-1 ST-101 ST-102 ST-103 ST-204 ST-200 ST-106 785 786 785 784 785 786 787 788 789 789 788 787 786 785 783783 777 776 772 773782 776777775774771 772777776 773776ST-105 ST-201 CONSTRUCTION LIMITS 78578478178277 4 774775779POND STORM ELEVATIONS 100 YR (DESIGN) = 779.39 100 YR (6" ORIFICE) = 779.28 10 YR (DESIGN) = 777.08 10 YR (6" ORIFICE) = 776.84 1% SLOPE782 784 783 786786786 786786786786 784784784784783783 775 777 778 776 779 780 781 782 783 780778783780779775780781782783 ST-202 784.48 787.43 785.30 785.30 783.40 786.33 786.32 785.40 784.40 784.29 784.37 784.00 783.70 783.70 783.63 783.70 783.63 784.48 784.40 784.39 784.32 784.14 784.07 783.73 783.79 783.42 783.48 784.30 783.77 784.00784.00 784.48 784.36 784.40 784.29 784.48784.48 784.48 783.08 783.15 783.65 783.42 783.42 784.48 784.48 783.40 783.60 783.55 783.90 784.10 783.70 786.56 787.10 787.00 787.05 786.80 786.30 786.62 786.12 786.85 786.35 787.23 786.73 787.05 786.55786.78 786.28 786.00 785.50786.25 785.75 786.50 786.00 786.25 785.75 785.01 784.51 784.84 784.34 784.75 784.25 784.55 784.05 784.62 784.12 784.50 784.00784.20 783.70 783.61 783.11 784.40 783.90 783.61 783.11 784.25 783.75 783.15 782.65 783.90 783.40 783.90 783.40 783.90 783.40 783.90 783.40 783.80 783.30 784.09 783.59 783.63 783.13 783.92 783.42 783.82 783.32 783.58 783.08 784.25 783.75 784.45 783.95 784.70 784.20 784.35 783.85 784.30 783.80 787.33 786.83 786.83 784.15 783.65 784.10 783.60 783.95 783.45 784.25 783.75 784.48 784.00 784.48 783.90 783.90 784.40 784.40 784.40 784.40 784.40 783.90 784.00 783.93 784.00 783.80784.00 784.48 784.00 784.40 784.29 784.36 783.75 783.68 783.75 783.68784.00 784.00 784.48 784.40 784.29 784.00 784.48 784.00 784.40 784.29 783.75 783.68 783.75 783.68 783.75 783.68 784.26 784.18 784.09 784.00 784.00 783.75 782.34 782.59 782.59 785.19 786.37 784.37 783.22 783.25 783.00 781.45 783.49 780.46 782.42 779.19 784.00 784.00 786.00 786.00 786.00 784.00 784.00 784.00 784.00 785 785785 785GENERAL NOTES 1. SEE SHEET G0.1 FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS. 2. REFER TO SURVEY SHEET FOR BOUNDARY, TOPOGRAPHIC, AND DATUM REFERENCE SURVEY INFORMATION. 3. REFER TO LANDSCAPE PLANS FOR PLANTINGS. 3. SEE SHEET SU2.3 FOR SANITARY PIPE INSTALLATION DETAILS. 4. SEE SHEET SU3.1 FOR WATER LINE INSTALLATION DETAILS. 5. DRAINAGE SYSTEM TO BE PRIVATE. 6. FLOOD PROTECTION GRADE - THE ELEVATION OF THE REGULATORY FLOOD PLUS TWO FEET AT ANY GIVEN LOCATION IN THE SPECIAL FLOOD HAZARD AREA. 7. NAVD 88 USED FOR ELEVATIONS LEGEND CLEANOUT SANITARY SEWER STORM SEWER MANHOLE / INLET WATER LINE GUTTER ELEV. TOP/CURB ELEV.600.50 600.00 650.00 SPOT ELEVATION CURB SPOT ELEVATION MATCH EXISTING GRADEMEG SEED DISTURBED AREA GRADING PLAN SCALE: 1"= 30'N 30 900 30 60 PLANNORTHN WS ECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT CONSULTANT PROJECT NUMBER: 2019199.00 INDOOR FACILITY AT BADGER FIELDS CLAY TOWNSHIP 5459 E MAIN STREET CARMEL, INDIANA PROJECT ISSUE DATE: 06.08.2020 DRAWN BY: MTP REV. NO. DESCRIPTION DATE 11300453 SOI STATE OF ORPFE S NEER N LA E N G IANAINIDERDAHC I IG S No. TERE DA C NIK.N DCONSTRUCTION DOCUMENTS PROJECT MANAGER: CNK PAD GRADING PLAN G3.4 SITE ADDRESS: 5459 EAST MAIN STREET CARMEL, IN 46033 DEPARTMENT OF PLANNING & DEVELOPMENT ADDRESS: ONE CIVIC SQUARE CARMEL, IN 46032 SURVEY INFORMATION FLOOD INFORMATION: The described real estate lies within Zone X (Unshaded) as plotted by scale on the Federal Emergency Management Agency, National Flood Insurance Program, FIRM Flood Insurance Rate Map for Community Number 180081, Map Number 18057C0227G, effective November 19, 2014. SEE SURVEY SHEETS (4 TOTAL) BY DLDS DATED APRIL 18, 2016 FOR SURVEY INFORMATION. STORM SEWER PIPE AND STRUCTURE NOTE: SEE SHEET SU2.5 FOR STORM STRUCTURE TABLE. INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what'sbelow. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 10/22/20