Loading...
HomeMy WebLinkAboutSU1 - Storm Sewer PlanPROPOSED 50' DRAINAGE& UTILITY EASEMENTP2P2P2P2P2P2P2P2P2P2P2P2P2P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P4P4P3P3P4P4P3P3P4P4P3P3 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2GGGGGGGGG FPFPFPFPFPFPFPFPGGGGGGGG G G G G G FP FPFPFPFP FP GG G G G G G G G G G G G G G G G GGGGGGGGG786 786 784 785 785784 785 786 787 788 789 789 788 787 786 785 7 8 4 783783 784783 783782783782781780780781782783772773 774 775 778 780 782 783 777778776775783782781779780777778774 776 775 778781 7827 8 0 783ST-202ST-203 ST-104 ST-BMP-1 ST-101 ST-102ST-103 ST-204 ST-200 ST-201 ST-106 ST-105 78 LF OF 30" RCP @ 0.40%220 LF OF 30" RCP @ 0.17% 210 LF OF 24" RCP @ 0.26%151 LF OF 30" RCP @ 0.35%236 LF OF 30" RCP @ 0.30%13 LF OF 30" HDPE @ 1.14% 18 LF OF 30" HDPE @ 0.40% 235 LF OF 24" RCP @ 0.30%224 LF OF 18" RCP @ 0.30% 128 L F O F 1 8" R C P @ 0. 3 0 %238 LF OF 15" RCP @ 0.30%1 11 1 11 1 1 2 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 14 1 ST-CO 1 RIM. = 773.44' INV. 772.92 (N) INV. 772.92 (S) ST-CO 2 RIM. = 774.42' INV. 773.90 (N) INV. 773.90 (S) ST-CO 4 RIM. = 776.38' INV. 775.86 (S) ST-CO 3 RIM. = 775.40' INV. 774.88 (N) INV. 774.88 (S)98 LF OF 6" PVC @ 1.00%98 LF OF 6" PVC @ 1.00%42 LF OF 6" PVC @ 1.00% 62 LF OF 6" PVC @ 1.00% ST-CO 5 RIM. = 773.64' INV. 773.12 (W) 3 5 67 7 68 9 1110 7 1213 1498 LF OF 6" PVC @ 1.00%15 16 16 16 16 ST-300 RIM. = 781.77' INV. 772.50 (N) INV. 772.50 (E) INV. 772.50 (S) 17 18 100 LF OF 12" RCP @ 0.50%ST-301 20 19 34 LF OF 10" PVC @ 0.50% 1 11 GENERAL NOTES 1.SEE SHEET G0.1 FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS. 2.REFER TO SURVEY SHEET FOR BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION. 3.REFER TO LANDSCAPE PLANS FOR PLANTINGS. 3.SEE SHEET SU2.3 FOR SANITARY PIPE INSTALLATION DETAILS. 4.SEE SHEET SU3.1 FOR WATER LINE INSTALLATION DETAILS. 5.SEE SHEET SU2.1 FOR STORM PIPE INSTALLATION DETAILS 6.ALL MANHOLES AND INLETS MUST BE PRE-STAMPED WITH "NO DUMPING DRAINS TO WATERWAY". SEE DETAIL CT-6 ON SHEET SU2.5. 7.NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 8.ALL EXISTING PERIMETER ROAD DRAINAGE STRUCTURES AND BRIDGES ACROSS THE FRONTAGE OF THIS DEVELOPMENT ARE INDICATED ON THE PLANS. PROVISIONS HAVE BEEN MADE TO IMPROVE OR REPLACE AND DRAINAGE STRUCTURES AND BRIDGES AS NECESSARY OR AS REQUESTED BY THE CITY TO ACCOMMODATE THE PAVEMENT WIDENING, AUXILIARY LANES, MULTI-USE PATH, AND ANY OTHER REQUIRED IMPROVEMENTS TO THE PROPERTY OR THE ROADWAY. THE COST TO IMPROVE OR REPLACE ANY DRAINAGE STRUCTURES AND BRIDGES WILL BE BORNE BY THE DEVELOPER. KEYNOTES 1 STORM SEWER CLEANOUT - SEE DETAIL ST-4/SU2.1 STORM LINE CROSSING/SANITARY SEWER LINE - 18" PVC STORM INV. EL. = 778.15' 6" PVC SANITARY INV. EL. = 778.98' (T/PIPE = 779.53') RIPRAP AT END SECTION - SEE DETAIL F/G4.2 DOWNSPOUT LOCATION - SEE DETAIL G ON SHEET SU2.4 11' OF 15" PVC @ 1.0% SLOPE 126' OF 12" PVC @ 1.00% SLOPE 64' OF 12" PVC @ 1.0% SLOPE 11' OF 18" PVC @ 1.0% SLOPE 64' OF 8" PVC @ 1.5% SLOPE 29' OF 12" PVC @ 5.0% SLOPE 128' OF 12" PVC @ 1.0% SLOPE 190' OF 15" PVC @ 1.0% SLOPE 24' OF 18" PVC @ 1.0% SLOPE 140' OF 8" PVC @ 1.0% SLOPE 8' OF 8" PVC @ 1.0% SLOPE UNDERDRAIN - SEE DETAIL B/SU2.4 10' OF 6" PVC CONNECT TO BLDG. PERIMETER DRAIN. SEE SEE STRUCTURAL FOR PERIMETER DRAIN INFORMATION. GAS METER - SEE MEP PLANS OUTLET CONTROL STRUCTURE - SEE DETAIL F/SU2.4 FOR ADDITIONAL INFORMATION AQUA-SWIRL BMP - SEE DETAIL A/SU2.4 FOR SIZE AND INVERT INFORMATION. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's below. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! LEGEND CLEANOUT GAS LINE STORM SEWER MANHOLE / INLET WATER LINE FIRE PROTECTION LINE FLOOD ROUTING SITE ADDRESS: 5459 EAST MAIN STREET CARMEL, IN. 46033 DEPARTMENT OF PLANNING & DEVELOPMENT ADDRESS: 1100 WEST OAK STREET ZIONSVILLE, IN. 46225 SURVEY INFORMATION FLOOD INFORMATION: The described real estate lies within Zone X (Unshaded) as plotted by scale on the Federal Emergency Management Agency, National Flood Insurance Program, FIRM Flood Insurance Rate Map for Community Number 180081, Map Number 18057C0227G, effective November 19, 2014. SEE SURVEY SHEETS (4 TOTAL) BY DLDS DATED APRIL 18, 2016 FOR SURVEY INFORMATION. STORM SEWER PIPE AND STRUCTURE NOTE: SEE SHEET SU1.1 FOR STORM STRUCTURE TABLE. SEE SHEET SU1.3 FOR STORM PROFILE. PIPE TABLE Downstream to Upstream Pipe Run ST-102 to ST-101 ST-103 to ST-102 ST-104 to ST-103 ST-105 to ST-104 ST-105 to ST-204 ST-106 to ST-BMP-1 ST-201 to ST-200 ST-202 to ST-201 ST-203 to ST-202 ST-204 to ST-203 ST-301 to ST-300 ST-BMP-1 to ST-105 Size 24" RCP 30" RCP 30" RCP 30" RCP 30" RCP 30" HDPE 15" RCP 18" RCP 18" RCP 24" RCP 12" RCP 30" HDPE Length 210' 220' 78' 151' 236' 18' 238' 128' 224' 235' 100' 13' Slope 0.26% 0.17% 0.40% 0.35% 0.30% 0.40% 0.30% 0.30% 0.30% 0.30% 0.50% 1.14% STORM STRUCTURE TABLE Str. 101 102 103 104 105 106 200 201 202 203 204 300 301 Rim 782.74 782.59 782.59 783.22 783.45 777.59 782.00 781.50 783.42 783.35 783.00 781.77 773.16 Inverts (SW) 10" PVC INV. = 779.65 (W) 24" RCP INV. = 777.99 (E) 24" RCP INV. = 777.44 (S) 18" PVC INV. = 779.70 (W) 30" RCP INV. = 777.30 (E) 30" RCP INV. = 776.92 (S) 15" PVC INV. = 779.70 (W) 30" RCP INV. = 776.81 (E) 30" RCP INV. = 776.50 (S) 30" RCP INV. = 776.40 (N) 30" RCP INV. = 775.87 (S) 30" RCP INV. = 776.21 (E) 6" PVC INV. = 779.50 (W) 30" HDPE INV. = 774.12 (E) 30" HDPE INV. = 773.80 (S) 15" RCP INV. = 779.78 (N) 15" RCP INV. = 779.07 (SW) 18" RCP INV. = 778.97 (NE) 18" RCP INV. = 778.59 (N) 8" PVC INV. = 779.20 (W) 18" RCP INV. = 778.49 (E) 18" RCP INV. = 777.82 (N) 18" PVC INV. = 780.35 (W) 24" RCP INV. = 777.72 (E) 24" RCP INV. = 777.02 (NE) 15" PVC INV. = 779.10 (N) 30" RCP INV. = 776.92 (N) 6" PVC INV. = 772.50 (E) 6" PVC INV. = 772.50 (S) 12" RCP INV. = 772.50 (N) 12" RCP INV. = 772.00 Casting R-2502 R-2502 R-2502 R-2502 R-1772 N/A R-2502 R-2502 R-1772 R-1772 R-1772 R-3405 N/A Detail A/SU2.1 A/SU2.1 B/SU2.1 B/SU2.1 B/SU2.1 C/SU2.1 A/SU2.1 A/SU2.1 A/SU2.1 A/SU2.1 B/SU2.1 F/SU2.4 C/SU2.1 Str. Size 4' DIA. 4' DIA. 5' DIA. 5' DIA. 5' DIA. (2' SUMP) N/A 4' DIA. 4' DIA. 4' DIA. 4' DIA. 6' DIA. 4' DIA. N/A PLANNORTHN WS ECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT CONSULTANT 6/13/2019 3:21:38 PM\\data1\citrixprofiles$\amiller\My Documents\218052.00_ARCH_amiller.rvtPROJECT NUMBER: 2019199.00 INDOOR FACILITY AT BADGER FIELDS CLAY TOWNSHIP 5459 E MAIN STREET CARMEL, INDIANA PROJECT ISSUE DATE: August 23, 2019 DRAWN BY: MTP REV. NO.DESCRIPTION DATE 11300453 SOI STATE OF ORPF E S NEER N LA E N GIANAINIDER DAHC I IG S No. TERE D A CNIK.N DTAC COMMENTS 09/06/20191 STORM SEWER PLAN SU1.1 NEW BUILDING FFE = 784.50' STORM SEWER PLAN SCALE: 1"= 40'N 40 12004080