HomeMy WebLinkAboutSU4_Site Utility PlanGENERAL NOTES1.SEE SHEET G1.0 FOR GENERAL NOTES, LEGEND ANDABBREVIATIONS.2.REFER TO SURVEY SHEET FOR BOUNDARY AND TOPOGRAPHICSURVEY INFORMATION.3.REFER TO LANDSCAPE PLANS FOR PLANTINGS.4.UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THERESPONSIBILITY OF THE OWNER. .5.SOUTHERN IRRIGATION WELL TO REMAIN ACTIVE INCLUDINGPUMPS, PRESSURE TANKS, BACK-FLOW PREVENTER, ANDELECTRICAL FEEDS.KEYNOTES1234567891011121314151617181920212223CONNECT TO EXISTING WATER LINE OFFSITE. PROVIDE TAP ONEXISTING WATER LINE WITH GATE VALVE. CONTRACTOR SHALLCONTACT LOCAL WATER UTILITY NOT LESS THAN 72 HOURSBEFORE START OF CONSTRUCTION OF WATER LINE. SEE SHEETSU1.3.C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.297' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.253' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2590' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2344' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2577' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2348' OF C-900 6" WATER LINE - SEE DETAIL CW3 ON SHEET SU4.2PIPE RESTRAINT - SEE DETAIL CW10 ON SHEET SU4.2 RESTRAINTSSHALL COMPLY WITH CITY OF CARMEL STANDARDS.FIRE DEPARTMENT CONNECTION - SEE DETAILS A ON SHEET SU4.1FIRE HYDRANT - SEE DETAIL CW8 ON SHEET SU4.2POST INDICATOR VALVE - SEE DETAIL A ON SHEET SU4.2GAS LINE - SEE MEP PLANS FOR SIZE AND ADDITIONALINFORMATIONGAS METER AND REGULATOR.SEE MEP PLANS FOR SIZE AND ADDITIONAL INFORMATION40' OF 6" FIRE PROTECTION LINE - SEE DETAIL CW3 ON SHEET SU4.2GATE VALVE ON 3" DOMESTIC WATER SERVICE LINE - SEE DETAIL BON SHEET SU4.2WATER LINE/SANITARY SEWER CROSSING. SEE DETAIL CS 32/SU2.341' OF 2" DOMESTIC WATER LINE4' ELECTRICAL TRANSFORMER CONCRETE PADPULL BOX - SEE ELECTRICAL PLANNEW LIFT STATION TO BE INSTALLED - SEE SHEET SU3.1552' OF FIRE PROTECTION TO FIRE DEPARTMENT CONNECTION -SEE DETAIL CW3 ON SHEET SU4.22" DOMESTIC WATER METERGATE VALVE ON 6" FIRE PROTECTION LINE - SEE DETAIL B ONSHEET SU4.2RELOCATE EXISTING FORCE MAIN AS NEEDEDRELOCATE EXISTING FIRE HYDRANT AND VALVE TO SOUTH OF THEMAINSTORM SEWER CLEANOUT - SEE DETAIL ST-4/SU2.1DOWNSPOUT LOCATION - SEE DETAIL G ON SHEET SU2.42425262728DEX. BUILDING
EX. BUILDING
4PROPOSED 50' DRAINAGE& UTILITY EASEMENTPROPOSED 50' DRAINAGE& UTILITY EASEMENT
INV @ 12" CPP W = 778.30INV @ 12" CPP E = 778.41INV @ 24" RCP W = 778.06INV @ 24" RCP E = 778.3212" CMPST-602ST-601ST-600211326INLETS, VALVES, AND MARKS MADE UPON THE GROUND BYALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOREXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIESSHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAYALL CONSTRUCTION.THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIESEVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES,SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUNDCAUTION !!Know what'sbelow.before you dig.CallRCall 811 or 1-800-382-5544 Before You Begin Any Digging Project.Call 48 hours or 2 working days before you dig.It's Fast, It's Easy and It's the Law in the state of Indiana! SITE UTILITY PLAN SCALE: 1"= 40'N4012004080LEGENDCLEANOUTGAS LINESTORM SEWERMANHOLE / INLETWATER LINESANITARY SEWER LINESTORM SEWER PIPE AND STRUCTURENOTE:SEE SHEET SU2.5 FOR STORM STRUCTURETABLE.SITE ADDRESS:5459 EAST MAIN STREETCARMEL, IN 46033DEPARTMENT OF PLANNING &DEVELOPMENT ADDRESS:ONE CIVIC SQUARECARMEL, IN 46032SURVEY INFORMATIONFLOOD INFORMATION:The described real estate lies within Zone X (Unshaded) asplotted by scale on the Federal Emergency ManagementAgency, National Flood Insurance Program, FIRM FloodInsurance Rate Map for Community Number 180081, MapNumber 18057C0227G, effective November 19, 2014.SEE SURVEY SHEETS (4 TOTAL) BY DLDSDATED APRIL 18, 2016 FOR SURVEYINFORMATION.SITE UTILITY PLANSU1.3MATCH LINE - SEE SHEET SU1.2PLAN
NORTH NW
SE COPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC.WWW.FHAI.COMARCHITECTCONSULTANTPROJECT NUMBER: 2019199.00INDOOR FACILITYAT BADGERFIELDSCLAY TOWNSHIP5459 E MAIN STREETCARMEL, INDIANAPROJECT ISSUE DATE: 06.08.2020DRAWN BY: MTPREV.NO.DESCRIPTIONDATECONSTRUCTION DOCUMENTSPROJECT MANAGER: CNKADDENDUM #16/25/2020ADDENDUM #27/1/2020ADDENDUM #37/8/2020COC REVISIONS10/5/2020