HomeMy WebLinkAboutM1 - MECHANICAL SCHEDULESCONTROL KEY: A. REMOTE TOUCHSCREEN LED WALL MOUNTED SPEED CONTROLS BY UNIT MANUFACTURER. CONTROLS SHALL BE CAPABLE OF CONTROLLING ALL FOUR FANS1. REFER TO SPECIFICATION SECTION 233423 FOR ADDITIONAL REQUIREMENTS.2. COLOR SHALL BE PROVIDED FROM MANUFACTURER'S FULL RANGE OF COLORS ASSELECTED BY ARCHITECT/ENGINEER.3. PROVIDE ALL SUPPLEMENTAL STEEL AS REQUIRED FOR PROPER HANGING OF THEFAN. FOLLOW THE MANUFACTURER'S INSTALLATION REQUIREMENTS.4. FAN SHALL BE HUNG AS HIGH AS POSSIBLE.5. VFC SHALL BE FACTORY MOUNTED TO THE MOTOR.6. COORDINATE LOCATION OF FAN AND ALL ASSOCIATED COMPONENTS WITH ALLTRADES.7. FANS SHALL BE INTERLOCKED TO SHUT DOWN IMMEDIATELY UPON RECEIVING AWATERFLOW SIGNAL FROM THE FIRE ALARM SYSTEM. COORDINATE WITH DIVISION 28 FROM A SINGLE CONTROLLER.DIFFUSER, REGISTER, AND GRILLE SCHEDULE(NOT ALL GRILLE TYPES MAY BE USED IN THIS SET OF PROJECT DOCUMENTS)NOTESHIGH VOLUME LOW SPEED CEILING FAN SCHEDULENOTESAIR-COOLED CONDENSING UNIT SCHEDULENOTES:62.3 51.867.4 51.1ACCU-1TONSNOMINALMARKMBHSUCTIONTEMPAMBIENTTEMPEERNOTES1. UNIT SHALL BE GROUND MOUNTED ON CONCRETE SUPPORT PAD.2. REFER TO PROJECT MANUAL SECTION 236200.56.5 5 45.0 95.0 11.01,2,3,4,5MCA10.64. UNIT SELECTED WITH R-410A REFRIGERANT.SERVICE460/33. INCLUDE THE FOLLOWING ACCESSORIES, HIGH AMBIENT UNLOARDER PRESSURESTAT, PROTECTIVE COIL GUARDS, PHASE LOSS/VOLTAGE PROTECTION, STANDARD AMBIENT CONTROL, AND VIBRATION ISOLATORS.5. INSTALL REFRIGERANT PIPING SIZE AND QUANTITY PER MANUFACTURERS REQUIREMENTS.MANUFACTURER& MODEL NO.DAIKIN - DX13SA0604AIR HANDLING/HEAT RECOVERY UNIT SCHEDULENOTESAHU/RTU MAXIMUM ALLOWABLE SOUND LEVELSROOFTOP UNIT SCHEDULENOTESMARK TYPEACDEFGHIJKLMNOPSIZENECKSIZE L"xW" NECK VEL.(FPM)MAX CORE/MAX. CFMCRITERIAMAX. NOISEMOUNTINGFRAME/REMARKSRETURN/AIRSIDEWALL-HEAVY DUTY5" 12"x12"8"10"24"x24"24"x24"8"x8"---12"x12"14"x14"16"x16"24"x24"SEE FLOOR800800800600500500500500500300-100300425175375475650PER PLANSPER PLANSPER PLANS13002120202020202020202020DUCT OR SIDEWALL:PROVIDE ALUMINUM SURFACE MOUNTREFER TO FLOOR PLANBORDER FOR DUCTED INSTALLATIONS.PLANS FOR SIZETRANSFER GRILLESUPPLY GRILLESUPPLY GRILLESQUARE PLAQUECEILING DIFFUSERSQUARE PLAQUECEILING DIFFUSERSQUARE PLAQUECEILING DIFFUSERRETURN/AIRTRANSFER GRILLERETURN/AIRTRANSFER GRILLERETURN/AIRTRANSFER GRILLERETURN/AIRTRANSFER GRILLESIDEWALL-RETURN GRILLESEE FLOORPLANS FOR SIZESEE FLOORPLANS FOR SIZEREFER TO REFLECTEDCEILING PLANREFER TO REFLECTEDCEILING PLANREFER TO REFLECTEDCEILING PLANREFER TO REFLECTEDCEILING PLANREFER TO REFLECTEDCEILING PLANREFER TO REFLECTEDCEILING PLANREFER TO REFLECTEDCEILING PLANREFER TO REFLECTEDCEILING PLANDUCT OR SIDEWALL:REFER TO FLOOR PLANDUCT OR SIDEWALL:REFER TO FLOOR PLANPROVIDE ALUMINUM SURFACE MOUNTBORDER FOR DUCTED INSTALLATIONS.PROVIDE ALUMINUM SURFACE MOUNTBORDER FOR DUCTED INSTALLATIONS.PROVIDE ALUMINUM SURFACE MOUNTBORDER FOR DUCTED INSTALLATIONS.PROVIDE ALUMINUM SURFACE MOUNTBORDER FOR DUCTED INSTALLATIONS.45 (DEGREE) DEFLECTION, UNLESSNOTED OTHERWISE ON FLOOR PLANFIXED 35 (DEGREE)DEFLECTION BLADESQHEAVY DUTY-- PER PLANS 20RETURN GRILLESEE FLOORPLANS FOR SIZEDUCT OR SIDEWALL:REFER TO FLOOR PLANFIXED 38 (DEGREE)DEFLECTION BLADES4-WAY BLOW DIFFUSERS, UNLESSINDICATED OTHERWISE ON DRAWINGS.4-WAY BLOW DIFFUSERS, UNLESSINDICATED OTHERWISE ON DRAWINGS.4-WAY BLOW DIFFUSERS, UNLESSINDICATED OTHERWISE ON DRAWINGS.FIXED 35 (DEGREE)DEFLECTION BLADES6"x6"10"x10"12"x12"14"x14"22"x22"OVERALLRTU-187 82 81 77 68 61 54 48RTU-1AHU-1UNIT SUPPLY DISCHARGEUNIT RADIATEDUNIT SUPPLY DISCHARGE- 101 96 94 93 90 87 8282 67 63 64 74 65 68 61MARK TYPERPMELECWATTSCONTROL DRIVE NOTESHVLS-1 HIGH VOLUME LOW SPEED CEILING FAN 78 1,100A DIRECT1,2,3,4,5,6,7HVLS-2A DIRECTHVLS-3A DIRECT7878HIGH VOLUME LOW SPEED CEILING FANHIGH VOLUME LOW SPEED CEILING FANMAXHVLS-4 HIGH VOLUME LOW SPEED CEILING FAN 78A DIRECTSERV480/3480/3480/3480/320'DIA.FAN6" 24"x24"8"10"24"x24"24"x24"600600600125200325292730MOTORIZED VAVCEILING DIFFUSERMOTORIZED VAVCEILING DIFFUSERMOTORIZED VAVCEILING DIFFUSERREFER TO REFLECTEDCEILING PLANREFER TO REFLECTEDCEILING PLANREFER TO REFLECTEDCEILING PLAN12" 24"x24" 600 450 32MOTORIZED VAVCEILING DIFFUSERREFER TO REFLECTEDCEILING PLAN4-WAY BLOW DIFFUSERS; DIV. 26CONTRACTOR TO SUPPLY 277/1 POWERAND TRANSFORMER TO MASTER DIFFUSER.PROVIDE LOW VOLTAGE WIRING TOSLAVE/DRONE DIFFUSER.& MODEL NO.MANUFACTURERGREENHECK - DS-6-20B6" 24"x24" 800 150 20SQUARE PLAQUECEILING DIFFUSERREFER TO REFLECTEDCEILING PLAN4-WAY BLOW DIFFUSERS, UNLESSINDICATED OTHERWISE ON DRAWINGS.20'20'20'1,1001,1001,100GREENHECK - DS-6-20GREENHECK - DS-6-20GREENHECK - DS-6-204-WAY BLOW DIFFUSERS; DIV. 26CONTRACTOR TO SUPPLY 277/1 POWERAND TRANSFORMER TO MASTER DIFFUSER.PROVIDE LOW VOLTAGE WIRING TOSLAVE/DRONE DIFFUSER.4-WAY BLOW DIFFUSERS; DIV. 26CONTRACTOR TO SUPPLY 277/1 POWERAND TRANSFORMER TO MASTER DIFFUSER.PROVIDE LOW VOLTAGE WIRING TOSLAVE/DRONE DIFFUSER.4-WAY BLOW DIFFUSERS; DIV. 26CONTRACTOR TO SUPPLY 277/1 POWERAND TRANSFORMER TO MASTER DIFFUSER.PROVIDE LOW VOLTAGE WIRING TOSLAVE/DRONE DIFFUSER.1,2,3,4,5,6,71,2,3,4,5,6,71,2,3,4,5,6,7INCFMOUTCFMCFMOUTINS.P.EXT.APDAPDELEC.H.P.HEAT WHEELCFMS.P.TOTAL2. REFER TO SPECIFICATION SECTION 237313.1. REFER TO PLANS & SCHEMATICS SHEETS FOR UNIT LAYOUT DETAILS.EAT LATTOTALCOOLING LOADCOILSCFMTOTALS.P.HPHPEXT.S.P.CFMEXHAUSTSUPPLYFANSNOTESHEAT WHEELEXHAUSTLATEATMARKSUPPLYSUMMER WINTERLATEATEATLATWINTERSUMMEREATLATSENS.DX COOLING COIL GAS FIRED HEATING COILLATEAT INPUTELEC.TYPETYPEELEC.5. VARIABLE FREQUENCY CONTROLLER (VFC) SHALL BE PROVIDED ON SUPPLY FAN, EXHAUST FAN, AND ENERGY RECOVERY WHEEL. VFC PROVIDED BY AHU MANUFACTURER.O.A.CFM3. MAXIMUM FILTER FACE VELOCITY SHALL BE 500 FPM.4. MAXIMUM COOLING COIL FACE VELOCITY SHALL BE 526 FPM.AHU-1460/3AFPURGE7. PROVIDE CONVENIENCE OUTLET AND LIGHTS ON A SEPARATE CIRCUIT.8. TOTAL STATIC PRESSURE REFLECTS A MEAN AIR PRESSURE9. BASIS OF DESIGN: DAIKIN - MODEL CAH005.5.60 3.02.501,70051066.361.70.1047.260.1460/32574.5 53.70.7951.038.61,2,3,4,5,6,7,8,9,1075.01,6005101,5755350.763.8AF1.5 3.03.811,600460/356.10.0180.1105.070.0MARK 63Hz 125Hz 250Hz 500Hz 1KHz 2KHz 4KHz 8KHzUNIT SOUNDDROP OF 0.55" FOR PREFILTERS AND FINAL FILTERS.APDAPDS.P.TOTAL5. REFER TO PLANS & SCHEMATIC SHEETS FOR UNIT LAYOUT DETAILS.2. REFER TO SPECIFICATION SECTION 237313.1. BASIS OF DESIGN: DAIKIN RPS090D.EAT LATTOTALCOOLING LOADCOILSCFMTOTALS.P.HPHPEXT.S.P.CFMEXHAUSTSUPPLYFANSNOTESMARKSENS.DX COOLING COIL GAS FIRED HEATING COILOUTPUTLATEAT INPUTELEC. TYPETYPEELEC.9. 20:1 TURNDOWN FOR NATURAL GAS HEAT MODULATION.6. FACTORY MOUNTED VARIABLE FREQUENCY CONTROLLER (VFC) SHALL BE PROVIDED ON THE SUPPLY FAN.MIN O.A.CFM3. MAXIMUM COOLING COIL FACE VELOCITY SHALL BE 500 FPM.4. MAXIMUM FILTER FACE VELOCITY SHALL BE 500 FPM.80.6 52.50.163.23RTU-120.01.5018,0001,375.0 1,100.096.340.0460/38,0000.36593.6917.17. PROVIDE CONVENIENCE OUTLET AND LIGHTS ON A SEPARATE CIRCUIT.1,2,3,4,5,6,7,8,9,10,11AIRFOIL8. PROVIDE SCROLL COMPRESSORS WITH STAGED CAPACITY CONTROL.PROP10.01.018,000460/391.3 75.8 2.6 65.2 74.0 79.3 72.0 50.7EER9.5IEER13.2OUPUT64.16. UNIT SHALL INCLUDE BYPASS DAMPER (SIZED FOR 100% AIRFLOW) AROUND HEAT WHEEL IN SUPPLY AIRSTREAM AND EXHAUST AIRSTREAM.10. 6 STAGE CAPACITY CONTROL FOR COOLING COIL.11. PROVIDE COIL GUARDS OF PAINTED, GALVANIZED-STEEL WIRE.10. SUMMER:INDOOR: 74° db/50% RHOUTDOOR: 91.3° db/75.0° wbWINTER:INDOOR: 72.0° dbOUTDOOR: 2.6° dbINDOOR: 72° db/50% RHOUTDOOR: 91.3° db/75.0° wbWINTER:INDOOR: 70.0° dbOUTDOOR: 2.6° db11. SUMMER:PLANNORTHNWSECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC.WWW.FHAI.COMARCHITECTCONSULTANT7/16/2019 3:49:21 PM\\data1\citrixprofiles$\mhopf\My Documents\218052.00_MECH_mhopf.rvtPROJECT NUMBER: 218052.00INDOOR FACILITYAT BADGERFIELDSCLAY TOWNSHIP5459 E MAIN STREETCARMEL, INDIANAMECHANICAL SCHEDULESM5.01PROJECT ISSUE DATE: JULY 16, 2019DRAWN BY: MZHPROPELLER UNIT HEATER SCHEDULEMark CFM RPM HP MBH HEATER KW ELEC LAT MANUFACTURER & MODEL NO. NOTESPUH-1 400 1550 1/8 11.2 3.3 480/3 86.1 RAYWALL - 5100 SERIES 1,2,3,4,5,6,8,9PUH-2 400 1550 1/8 11.2 3.3 480/3 86.1 RAYWALL - 5100 SERIES 1,2,3,4,5,6,8,9PUH-3 400 1550 1/8 17.1 5.0 480/3 99.5 RAYWALL - 5100 SERIES 1,2,3,4,5,6,8,9PUH-4 1100 1550 1/8 51.2 15.0 480/3 103.0 RAYWALL - 5100 SERIES 1,2,3,4,5,6,8,9PUH-5 400 1550 1/8 17.1 5.0 480/3 99.5 RAYWALL - 5100 SERIES 2,3,4,5,6,7,8,9CABINET UNIT HEATER SCHEDULEMARK CFM RPM HP MBH HEATER KW ELEC LAT MOUNTING MANUFACTURER & MODEL NO. NOTESCUH-1 250 1550 1/8 3.4 2 480/3 85.2 FACE SUPPLY / FACE RETURN RAYWALL - T33 1,2,3,4,5,6,7CUH-2 250 1550 1/8 3.4 2 480/3 85.2 FACE SUPPLY / FACE RETURN RAYWALL - T33 1,2,3,4,5,6,7CUH-3 250 1550 1/8 3.4 2 480/3 85.2 FACE SUPPLY / FACE RETURN RAYWALL - T33 1,2,3,4,5,6,7CUH-4 750 1550 1/8 23.1 15 480/3 123.2 FACE SUPPLY / FACE RETURN RAYWALL - T66 1,2,3,4,5,6,7CUH-5 750 1550 1/8 23.1 15 480/3 123.2 FACE SUPPLY / FACE RETURN RAYWALL - T66 1,2,3,4,5,6,7EXHAUST FAN SCHEDULEMARK TYPE CFM RPM EXT. S.P. MAX SONES HP ELEC CONTROL DRIVE MANUFACTURER & MODEL NO. NOTESEF-1 INLINE 850 1,296 0.375 in-wg 7.0 1/4 115/1 A DIRECT GREENHECK - SQ-100-A 1,2,3,4,5,6EF-2 INLINE 400 1,473 0.375 in-wg 6.8 1/10 115/1 A DIRECT GREENHECK - SQ-90-D 1,2,3,4,5,6EF-3 INLINE 1500 1,008 0.375 in-wg 7.9 1/3 277/1 B DIRECT GREENHECK - SQ-140-B 1,2,3,4,5,6EF-4 INLINE 1200 1,316 0.425 in-wg 8.2 1/2 277/1 B DIRECT GREENHECK - SQ-120-A 1,2,3,4,5,6NOTE:1 SUPPORT HEATER FROM STRUCTURE ABOVE WITH A MINIMUM OF (2) 3/8" DIAMETER THREADED RODS UNLESS OTHERWISE NOTED.2 UNIT SHALL BE SELECTED WITH THE LOW FAN SPEED SETTING.3 ELECTRIC HEAT4 UNIT FURNIISHED WITH ADJUSTABLE LOUVER FIN DIFFUSES TO PROVIDE DIRECTIONAL AIR FLOW CONTROL.5 INCLUDE FACTORY MOUNTED DISCONNECT6 UNIT SHALL BE SELECTED WITH A 60°F ENTERING AIR TEMPERATURE.7 SUPPORT HEATER FROM ADJACENT WALL WITH MANUFACTURER PROVIDED WALL BRACKETS.8 INCLUDE FACTORY MOUNTED THERMOSTAT BUILT INTO THE UNIT. THERMOSTAT SHALL BE FULLY ADJUSTABLE.9 REFER TO SPECIFICATION SECTION 238239.NOTE:1 COLOR SHALL BE PROVIDED FROM MANUFACTURER'S FULL RANGE OF COLORS AS SELECTED BY THE ARCHITECT/ENGINEER.2 INCLUDE FACTORY MOUNTED DISCONNECT3 HORIZONTAL RECESSED UNIT4 SUPPORT UNIT HEATER FROM STRUCTURE ABOVE WITH A MINIMUM OF (4) 3/8" DIAMETER THREADED RODS AND VIBRATION ISOLATORS.5 INCLUDE FACTORY MOUNTED THERMOSTAT BUILT INTO THE UNIT. THERMOSTAT SHALL BE FULLY ADJUSTABLE.6 UNIT SHALL BE SELECTED WITH A 60°F ENTERING AIR TEMPERATURE.7 REFER TO SPECIFICATION SECTION 238239.NOTE:1 INCLUDE FACTORY MOUNTED DISCONNECT SWITCH.2 INCLUDE BACKDRAFT DAMPER.3 SUPPORT FROM STRUCTURE ABOVE WITH THREADED ROD AND VIBRATION ISOLATORS.4 REFER TO SPECIFICATION SECTION 233423 FOR ADDITIONAL REQUIREMENTS5 INCLUDE FACTORY MOUNTED SPEED CONTROLLER.6 COLOR SHALL BE PROVIDED FROM MANUFACTURER'S FULL RANGE OF COLORS AS SELECTED BYARCHITECT/ENGINEER.KEY:A AUTOMATIC OPERATION BY REVERSE ACTING THERMOSTAT.B LIGHT SWITCH CONTROL BY DIVISION 26.WALL LOUVER SCHEDULEMARK LENGTH HEIGHTTOP OF LOUVERELEVATIONTYPE MODEL NOTESWL-1 32" 16" 9'-0" WL-1 EXHAUST 1,2,3,4,5WL-2 32" 16" 9'-0" WL-1 EXHAUST 1,2,3,4,5WL-3 48" 24" 21'-4" WL-1 INTAKE 1,2,3,4,5WL-4 64" 24" 22'-6" WL-1 EXHAUST 1,2,3,4,5NOTE:1 REFER TO PROJECT MANUAL SECTION 089119.2 SEAL ALL AROUND WITH SILICONE.3 REFER TO INSTALLATION DETAILS ON ARCHITECTURAL DRAWINGS AND MECHANICAL DRAWINGS.4 CUSTOM COLOR AS SELECTED BY ARCHITECT/ENGINEER.5 COORDINATE SIZE AND LOCATION WITH ALL TRADES. P R O FE S SIONALENGINEERNo.PE 19800147STATE OFREGISTERED INDIANATIMOTHYC.LEH MA N REV.NO.DESCRIPTION DATE