HomeMy WebLinkAboutROOF PLANROOF PLAN GENERAL NOTESA. ALL DETAILS SHOWN ARE FOR GENERAL INFORMATION. ALL FINAL FLASHING CONDITIONS SHALL BE THE RESPONSIBILITY OF THE ROOF INSTALLER, AND SHALL MEET APPROVAL OF ROOF MANUFACTURER.B. ALL DETAIL MODIFICATIONS MUST HAVE SHOP DRAWINGS APPROVAL. CONTRACTOR SHALL INSPECT AND VERIFY ALL EXISTING FIELD CONDITIONS, CLEARANCES, AND DIMENSIONS BEFORE STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF EXISTING CONDITIONS. SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED, CONTACT ARCHITECT BEFORE PROCEEDING WITH ANY FURTHER WORK.C. PROVIDE FLASHING AND SADDLES FOR ALL EQUIPMENT PROVIDED UNDER MECHANICAL.D. SADDLES AND TAPERED INSULATION SYMBOLS INDICATE DESIGN INTENT TO SLOPE TO DRAIN. CONTRACTOR SHALL PROVIDE SUBMITTAL DRAWIINGS FOR TAPERED INSULATION AND SADDLES TO INSURE POSITIVE SLOPE.E. THE ROOF CONTRACTOR SHALL PROTECT ALL ROOF DRAINS, SCUPPERS, AND DOWNSPOUTS FROM DEBRIS CREATED DURING DEMOLITION AND CONSTRUCTION. THE ROOF CONTRACTOR SHALL INSPECT AND CLEAR ALL DRAINS, SCUPPERS, AND DOWNSPOUTS PRIOR TO COMPLETION OF WORK AND TO ENSURE THAT THEY ARE FREE OF DEBRIS AND ARE FUNCTIONING PROPERLY.VERIFICATION NOTECONTRACTOR SHALL VERIFY ALL DIMENSIONS ANDCLEARANCES AND ALL EXISTING FIELD CONDITIONSBEFORE STARTING CONSTRUCTION. COMMENCEMENTOF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS.SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED,CONTACT THE ARCHITECT BEFORE PROCEEDING WITHWORK.ROOF PLAN SYMBOL LEGENDSLOPE? / 12INDICATES ROOF DRAIN (RD) AND OVERFLOW DRAIN (OD). (FLASH IN ACCORDANCE WITH ROOF MEMBRANE MANUFACTURER'S RECOMMENDATION.) INDICATES VENT STACK -REFER TO PLUMBING DRAWINGS INDICATES FLUE -REFER TO MECHANICAL DRAWINGS INDICATES MECHANICAL EQUIPMENT -REFER TO MECHANICAL DRAWINGSINDICATES ROOF SLOPEINDICATES ROOF SADDLE -REFER TO PROJECT MANUAL.INDICATES EXPANSION JOINT -REFER TO ROOF PLAN AND WALL SECTIONS.INDICATES WALL LINE BELOW -REFER TO ARCHITECTURAL FLOOR PLANS INDICATES SLOPE OF TAPERED ROOF INSULATION 1/4 / FT MIN (UNO). INDICATES FORMED METAL DOWNSPOUT (6x6 UNO). REFER TO ROOF PLAN AND BUILDING ELEVATIONS FOR LOCATIONS (UNO) 12'-0"(UNO) 8'-0"VSDSFLROOF PLAN NOTES*MECHANICAL, ELECTRICAL AND PLUMBINGINFORMATION SHOWN ON THIS PLAN IS GENERAL IN NATURE. REFER TO P, M AND E DRAWINGS FOR FURTHER INFORMATION AND COORDINATE ALL REQUIRED ROOFOPENINGS OR ROOF MOUNTED EQUIPMENT.X3A5.02RIDGE1 1/2" / 12"1 1/2" / 12"1A5.031 1/2" / 12"1 1/2" / 12"RIDGEHIGHLOW1234144DSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDSDS2323232A5.033A5.03DSDS4A5.035661A5.022A5.028A5.014A5.028A5.01SIMDSDSDSSCREEN WALLSCREEN WALL2A1.022A1.02SIM1'-6"5'-0" 1'-6" 30'-0" 34'-0"71 34'-0"3SECOND ROW, THIS LOCATION ONLYB./ ROOF FRAMINGREFER TO WALL SECTIONS1" (UNO)MIN1'-0"ROOF FRAMING REFER TO STRUCTURALCOMPRESSIBLE INSULATION WITH FLEXIBLE MOISTURE BARRIERFACED METAL BUILDING INSULATION REFER TO WALL SECTIONSMETAL WALL PANEL REFER TO BUILDING ELEVATIONS AND WALL SECTIONS FOR TYPEMETAL BUILDING GIRTMETAL BUILDING PURLINSTANDING SEAM METAL ROOFING SYSTEM REFER TO ROOF PLANEXPANSION JOINT -SIDE WALL METAL FLASHING WITH 4" SEALED LAP JOINTS IN DIRECTION OF FLOWEXTEND VERTICAL LEG OF METAL FLASHING BEHIND METAL WALL PANEL (2" MIN) AND ANCHOR. PROVIDE SLOTTED ANCHORS TO ACCOMMODATE EXPANSION. SET ANCHORS IN MASTICMIN2"FACED METAL BUILDING INSULATION REFER TO WALL SECTIONS10 3/4" ±ROOF FRAMING REFER TO STRUCTURALNPLANNORTHNWSECOPYRIGHT 2020 BY FANNING/HOWEY ASSOC, INC.WWW.FHAI.COMARCHITECTCONSULTANT6/25/2020 4:44:24 PM\\data1\citrixprofiles$\amiller\My Documents\218052.00_ARCH_amiller.rvtPROJECT NUMBER: 218052.00INDOORFACILITY ATBADGERFIELDSCLAY TOWNSHIP5459 E MAIN STREETCARMEL, INDIANAROOF PLANA2.01PROJECT ISSUE DATE: JUNE 8, 2020CONSTRUCTION DOCUMENTSDRAWN BY: MDM AMPROJECT MANAGER: AMSCALE: 1/16" = 1'-0"ROOF PLAN1 ROOF TYPE: STANDING SEAM METAL ROOFINGSYSTEM ON PURLINS OVER STEEL TRUSSES2 FORMED METAL GUTTER (8x8 UNO)3 SNOW GUARDS BY METAL BUILDING MFGR. (1)ROW (UNO). LOCATE 1'-0" FROM ROOF EDGE(UNO)4 FORMED METAL GABLE TRIM WITH METAL FASCIA5 PREFORMED JOINT SEAL (CONT) 1" VERTICAL @SFCMU BELOW6 EXPANSION JOINT (1" VERTICAL) BY METALBUILDING MFGR.7 ROOF TYPE: METAL BUILDING STANDING SEAMMETAL ROOF PANELS OVER 3/4" EXTERIORGRADE PLYWOOD ON 3 5/8" COLD FORMEDMETAL FRAMINGSCALE: 1 1/2" = 1'-0"DETAIL1WILLIAME.PA YNEREGISTERED INDIANAAR CHITECT4169STATE OFNo.REV.NO.DESCRIPTION DATE1 ADD #1 6/25/201