Loading...
HomeMy WebLinkAboutLS2-1 - LIFE SAFETY PLAN & CODE SUMMARYF.E.C.24x3621x48 21x4221x42 21x4221x42 21x48 21x48 21x36 21x48 21x48 24x48LIFE SAFETY LEGEND REQUIRED BUILDING EXIT ASSEMBLY (TABLES & CHAIRS) (UN-CONCENTRATED - 15 NET) ASSEMBLY (STANDING ROOM WAITING) (CONCENTRATED - 5 NET) BUSINESS (100 GROSS) KITCHEN (200 GROSS) UTILITY / MECH / STORAGE (300 GROSS) DESCRIPTIONSYMBOL LINE TYPE FIRE EXTINGUISHER LOCATION (REFER TO PLAN KEYNOTES) E.T. PATH OF EGRESS TRAVEL D.D. DIAGONAL DISTANCE OF SPACE ES RAISED CHARACTER AND BRAILLE EXIT SIGN 1 HR 1 HR FIRE RESISTANCE RATED CONSTRUCTION C.P.E.T. COMMON PATH OF TRAVEL M.R.P. E.A.T. MOST REMOTE POINT & EXIT ACCESS TRAVEL DISTANCE EXIT 37'-11 1/2"16'-9"60'-0" VIF76'-9"1'-4" 13'-1" VIF 36'-2 1/2" VIF 24'-10 1/2" VIF 10'-0" 13'-1" FOLDING PARTITION WALL SYSTEM WITH DOOR VEST. 101 LOBBY 102 COOLER 114 ALCOVE 104 PICK UP 107 WAIT STATION 108 SOUTH DINING 106 NORTH DINING 109PRIVATE DINING 110 DISHWASHING 111 KITCHEN 112 STORAGE 113 TLT 105 TLT 103 EXITEXITEXITMOVABLE BUFFETS EXTERIOR PATIO PROPOSED ONE-HOUR RATED DEMISING WALL (UL U465) (BY LANDLORD)F.E.F.E. F.E. COMMON PATH OF EGRESS TRAVEL (InBC 1014.3) ALLOWABLE / REQURED PROVIDED CODE SUMMARY CHART EXIT ACCESS TRAVEL DISTANCE (InBC 1016.2) FIRE-RESISTANT CORRIDORS (InBC 1018.1) CORRIDOR WIDTH (InBC 1018.2) EGRESS WIDTH PER OCC. STAIRS OTHER 75' MAX 250' (MAX) (WITH SPK) NON-RATED (SPRINKLED) 44" MIN. 48' MAX. 112' +/- NON-RATED N/A PLUMBING FIXTURE COUNT WATER CLOSETS LAVS DRINKING FOUNTAINS SERVICE SINK 150 OCC 1 PER 75 (2 REQ.) 1 PER 200 (2 REQ.) 1 PER 500 (1 REQ.) 1 (MIN.) 2 WC PROV. 2 LAVS PROV. 0 DF * 1 1.5" 10" (MIN.) N/A 72" * FACILITY WILL SERVE WATER TO CUSTOMERS, THEREFORE A DRINKING FOUNTAIN IS NOT REQUIRED. OCCUPANT LOAD SUMMARY TOTAL EXISTING TENANT AREA: 3,513 SF / 106 OCC DINING AREA (15 NET) ------------------------------- 1,315 SF / 88 OCC WAITING AREA (5 NET) ------------------------------ 60 SF / 13 OCC BUSINESS (100 GROSS) ----------------------------- 115 SF / 2 OCC KITCHEN (200 GROSS) ------------------------------- 910 SF / 5 OCC COMMON AREA (N/A) --------------------------------- 1,113 SF / - OCC EXTERIOR AREA: 660 SF / 44 OCC EXTERIOR PATIO (15 NET) -------------------------- 660 SF / 44 OCC USEABLE TOTAL AREA (INCL. SITE): 4,173 SF / 150 OCC NOTE: "COMMON AREA" REFERS TO SPACE WITHIN THE FLOOR PLAN WHICH IS NOT CONSIDERED OCCUPIED SUCH AS REQUIRED EGRESS PATHWAYS. "EXTERIOR PATIO" AREA AND "USEABLE TOTAL AREA" IS ONLY SHOWN TO BE APPLIED TOWARD PLUMBING FIXTURE COUNTS AS REQUIRED BY CHAPTER 29. GENERAL LSP NOTES & CODE SUMMARY 1. INFORMATION IS PROVIDED FOR USE BY CODE REVIEW PERSONNEL AND COORDINATION WITH ALL CONTRACTORS. ALL CONSULTANTS AND CONTRACTORS ARE RESPONSIBLE FOR COMPLYING WITH APPLICABLE CODE PROVISIONS INCLUDING, BUT NOT LIMITED TO, THOSE LISTED BELOW. NOT ALL DETAILS / CONDITIONS MAY BE SHOWN. NOTIFY ARCHITECT OF ANY DISCREPANCIES AS SOON AS POSSIBLE. 2. THIS PROJECT CONSISTS OF THE FIRST TIME BUILD-OUT OF A RETAIL STRIP CENTER TENANT AREA. THE BUILDING CONSISTS OF MULTIPLE TENANT BAYS. 3. THE EXISTING BUILDING CONSTRUCTION CONSISTS OF CONCRETE FOUNDATIONS AND SLAB WITH STRUCTURAL STEEL COLUMNS AND BEAMS WITH METAL BAR JOISTS AND DECKING AND A MEMBRANE ROOF SYSTEM. THE EXTERIOR CLADDING INCLUDES MASONRY AND METAL PANEL WITH STOREFRONT GLAZING AND ENTRANCE SYSTEMS. 4. REFER TO THE FLOOR PLANS FOR FOR FIRE EXTINGUISHER TYPES AND LOCATIONS. 5. OCCUPANCY CLASSIFICATION (PER InBC SECT. 303): EXISTING: M (MERCANTILE) PROPOSED: A-2 (RESTAURANT) 6. BUILDING TYPE CLASSIFICATION: II-B (EXISTING) 7. HEIGHT AND AREA: EXISTING BUILDING HEIGHT AND AREA ARE COMPLIANT WITH ALLOWABLE HEIGHT AND AREA FROM TABLE 503. NO CHANGE TO THE BUILDING ENVELOPE IS PROPOSED. 8. OCCUPANCY SEPARATIONS: THE BUILDING CONSISTS OF MULTIPLE TENANTS. A ONE (1) HOUR FIRE-RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER) IS BEING PROVIDED BETWEEN THE PROJECT AREA AND THE ADJACENT TENANT BAY. 9. FIRE-RESISTANCE RATED CONSTRUCTION: CONSTRUCTION ELEMENTS MUST BE NON-COMBUSTIBLE UNLESS OTHERWISE ALLOWED BY InBC SECTION 603. REFER TO THE "FIRE-RATED CONSTRUCTION NOTES" ON THIS SHEET. 10. AUTOMATIC SPRINKLERS: SPRINKLERS ARE REQUIRED BY InBC CHAPTER 9 FOR A-2 OCCUPANCIES WITH 100 OR MORE OCCUPANTS. A BUILDING-WIDE SPRINKLER SYSTEM EXISTS IN THE BUILDING AND WILL BE MODIFIED TO PROVIDE COVERAGE FOR THE TENANT AREA. 11. FIRE ALARM & DETECTION SYSTEMS: A FIRE ALARM SYSTEM IS NOT REQUIRED FOR THIS TENANT AREA DUE TO HAVING LESS THAN 300 OCCUPANTS (PER InBC 907.2.1). AN AUTOMATIC SMOKE DETECTION SYSTEM IS NOTREQUIRED. NOTIFICATION DEVICES WHICH ARE PART OF THE SPRINKLER SYSTEM MAY BE REQUIRED; THESE COMPONENTS SHALL BE PROVIDED BY THE SPRINKLER CONTRACTOR. 12. COMMON PATH OF EGRESS (CPE) TRAVEL: COMMON PATH OF EGRESS TRAVEL IS LIMITED TO 75' IN ASSEMBLY OCCUPANCY TENANT AREAS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (REFER TO THE CODE SUMMARY CHART AND LIFE SAFETY PLAN). 13. EXIT ACCESS TRAVEL (EAT) DISTANCE: EXIT ACCESS TRAVEL DISTANCE IS PERMITTED TO BE 250' PER InBC TABLE 1016.2 FOR ASSEMBLY OCCUPANCY TENANT AREAS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (REFER TO THE CODE SUMMARY CHART AND LIFE SAFETY PLAN). 14. CORRIDOR FIRE RESTANCE RATINGS: CORRIDORS IN ASSEMBLY OCCUPANCY TENANT AREAS WHERE AN AUTOMATIC SPRINKLER SYSTEM IS INSTALLED ARE ALLOWED TO BE NON-FIRE RATED. 15. GENERAL MEANS OF EGRESS: NUMBER AND WIDTH OF EXITS IS EQUAL TO OR GREATER THAN THE MINIMUM REQUIRED BY InBC CHAPTER 10 (REFER TO THE CODE SUMMARY CHART AND LIFE SAFETY PLAN ) 16. EMERGENCY / EGRESS LIGHTING: REFER TO THE ELECTRICAL PLANS FOR LOCATIONS AND CONFIGURATION OF EMERGENCY EGRESS LIGHTING AND EXIT SIGNAGE. 17. THE 2010 INDIANA ENERGY AND CONSERVATION CODE (InECC) DOES APPLY TO THIS PROJECT. COMCHECK ENERGY CODE ANALYSES SHALL BE PROVIDED FOR CHANGES TO THE BUILDING ENVELOPE, INTERIOR LIGHTING, AND MECHANICAL EQUIPMENT AS REQUIRED. 18. SIGNAGE SHALL BE INSTALLED TO MEET MINIMUM CODE STANDARDS AS FOLLOWS: INSTALL GRAPHIC & RAISED CHARACTER AND BRAILLE SIGNS AT EACH EXIT DOOR AND AT NEW TOILET FACILITIES. INSTALL SIGNS ON THE LATCH SIDE OF SINGLE LEAF DOORS (48" AFF TO THE BRAILLE) AND AT EITHER SIDE OF DOUBLE LEAF DOORS. INSTALL OTHER SIGNAGE AS REQUIRED BY CODE BASED ON FIELD CONDITIONS. VENDOR CONTACT LIST LANDLORD / BUILDING OWNER LOR CORPORATION ADAM HILL (317) 205 - 1200 ACCORDING TO THE LANDLORD THE FOLLOWING CONTRACTORS WERE INVOLVED IN THE CONSTRUCTION OF THIS BUILDING SHELL: GARDNER FIRE PROTECTION JASON GARDNER (317) 716 - 9756 IRC ROOFING (317) 299-0637 EM COMPANY (HVAC) (317) 783-3291 FIRE-RATED CONSTRUCTION NOTES 1. COORDINATE THE FIRE RESISTANCE RATED CONSTRUCTION REQUIREMENTS WITH THE OVERALL & LIFE SAFETY PLANS AND THE ENLARGED FLOOR PLANS AS REQUIRED TO PROVIDE ALL RATED CONSTRUCTION PURSUANT TO CODE COMPLIANCE. 2. A BRIEF SUMMARY OF PLANNED FIRE-RESISTANCE RATED CONSTRUCTION IS AS FOLLOWS. COORDINATE U.L. TESTED VERTICAL AND HORIZONTAL ASSEMBLIES WITH PLAN WALL TYPES: * EXTERIOR FIRE-RATED WALLS: N/A (EXISTING) 3. * OCCUPANCY SEPARATIONS: ONE-HOUR RATED CONSTRUCTION BETWEEN PROJECT AREA AND ADJACENT TENANT BAY * EXHAUST HOOD PROXIMITY: PROVIDE NON-COMBUSTIBLE FRAMING WITHIN 18" AND BEHIND TYPE I EXHAUST HOOD ELEMENTS WHETHER CONCEALED OR EXPOSED. * OTHER CONDITIONS: AS NOTED ON THE PLANS. TENANT AREA (3,513 S.F.) SITARA INDIANA CUISINE DINING PATIO (SEE ENLARGED DETAIL 3/LS2.1) 7 GENERAL SITE NOTES: 1. THE SITE PLAN IS SHOWN FOR REFERENCE PURPOSES ONLY. PROTECT ALL EXISTING PAVED HARD SURFACES AND LANDSCAPED SITE ELEMENTS TO REMAIN FOR RE-USE. 2. THE SITE DIAGRAM PROVIDED IS THAT WHICH WAS PREPARED DURING BUILDING SHELL CONSTRUCTION. DISREGARD KEYNOTE REFERENCES AND ANNOTATIONS ON THE SITE DIAGRAM AND FIELD VERIFY ALL EXISTING SITE CONDITIONS AND DIMENSIONS PRIOR TO THE START OF ALL TENANT IMPROVEMENT RELATED CONSTRUCTION ACTIVITIES. 3. THE SITE-RELATED PROJECT SCOPE INCLUDES SEMI-PERMANENT AND MOVABLE PATIO ELEMENTS SUCH AS FENCING, PLANTERS, DINING FURNITURE, ETC. 4. OBTAIN BUILDING OWNER (LANDLORD) AND LOCAL AUTHORITY HAVING JURISDICTION APPROVAL FOR ALL PATIO AND EXTERIOR SIGNAGE RELATED DESIGN ELEMENTS AND PROPOSED CONSTRUCTION DETAILS PRIOR TO STARTING ANY PATIO-RELATED CONSTRUCTION ACTIVITIES. 5. ALL DIMENSIONS ARE FROM FACE OF EXISTING MATERIAL, UNLESS NOTED OTHERWISE. EXISTING CONCRETE PATIO SLAB TO REMAIN FOR RE-USELINE OF EXISTING CONCRETE PATIO SLAB TO REMAIN FOR RE-USE RE-LOCATED EXTERIOR STOREFRONT ENTRANCE (SEE FLOOR PLANS) EXISTING LANDSCAPING TO REMAIN (COMPACT JAPANESE HOLLY) PUBLIC SIDEWALK CONNECTOR TO REMAIN (SEE OVERALL SITE PLAN -VIF) EXTERIOR PATIO 36" DECORATIVE METAL FENCE BY OWNER 36" DECORATIVE METAL FENCE BY OWNER 9'-6"22'-0"25'-0"22'-4"EXTERIOR PATIO NOTES: 1. PROVIDE PRODUCT DATA AND / OR CUT SHEETS FOR ALL EXTERIOR PATIO RELATED FENCING, PLANTERS, PLANTINGS, AND DINING FURNITURE FURNITURE FOR LANDLORD AND CITY APPROVAL PRIOR TO THE START OF PATIO-RELATED CONSTRUCTION ACTIVITIES. STATE OF 900019 No.MICHA E L W .HAL S TEADIND I A N AREGISTER E DA RCH I T E C T PROJECT NUMBER DATE 1139 SHELBY STREET INDIANAPOLIS, IN 46203 317.684.1431 CERTIFIED BY: 123 EAST THIRD ST. MARION, INDIANA 46952 765.662.9372 www.halstead-architects.com REVISIONS ISSUE DRAWING © 2019 Halstead Architects All Rights Reserved- - - - - - - 100% CONSTRUCTION DOCS. - 09/01/2020HAMILTON COUNTY | CLAY TOWNSHIPLS2.1 2026INTERIOR TENANT FINISH FORSEPTEMBER 1, 2020 LIFE SAFETY PLAN, CODE SUMMARY & SITE DIAGRAMSITARA INDIAN CUISINE13080 GRAND BLVDCARMEL, INDIANA 46032SCALE: 3/16" = 1'-0" 1 LIFE SAFETY PLAN TENANT AREA SCALE: 1" = 40'-0"2 3-SITE DIAGRAM EXISTING SCALE: 3/16" = 1'-0"3 PATIO PLAN ENLARGED EXTERIOR 10/20/20