Loading...
HomeMy WebLinkAboutP9-1 - PLUMBING DETAILSBALL VALVE REDUCED PRESSURE BACKFLOW PREVENTER, MAXIMUM MOUNTING HEIGHT OF 5'-0" ABOVE FLOOR. BALL VALVE TO SYSTEM FROM WATER SUPPLY SOURCE AIR GAP DRAIN FUNNEL PIPE DISCHARGE TO FLOOR DRAIN OR MOP SINK AT REFRIGERATORS = 12" AFF. AT ICE MACHINES = 12" AFF. AT COUNTERS = 1" ABOVE COUNTER BACK SPLASH, FOR COFFEE MAKER SUPPLY VARIESREFRIGERATOR ICE MAKER RECESSED WALL BOX WITH FACE PLATE; EQUAL TO OATEY SERIES RECESSED WALL BOXES ANGLE STOP VALVE WITH THREADED CONNECTION FOR ICE MAKER TUBING 1/2"CW FLOOR LINE MOUNT MOTOR SHAFT IN VERTICAL POSITION STRAINER FROM SYSTEM ISOLATION VALVE (REFER TO SPECS) SHUTOFF COCK (TYP) PRESSURE GAUGE CHECK VALVE UNION (TYP) PUMP AND MOTOR TO SYSTEM PIPE HANGER WITH SPRING ISOLATORS CONCENTRIC REDUCER (AS REQUIRED) CONCENTRIC INCREASER (AS REQUIRED) INOUT SPAN 4 JOIST PIPE PERPENDICULAR TO JOIST 3"x3"x1/4" ANGLE PIPE PARALLEL TO JOIST WELD WELD WELD WELD WELD 3"x3"x1/4" ANGLE 1. SPIDER INSTALLED FOR MAXIMUM TRAVEL. 2. INSTALL UPSTREAM AND DOWNSTREAM OF STEAM EXPANSION LOOPS. NOTE: PIPE AND INSULATION SPIDER GUIDE DRAIN VALVE WITH HOSE BIB ADAPTER AND CAP STRAINER CHECK VALVE BALL VALVE AUTOMATIC FLOW CONTROL VALVE BALL VALVE FLOWFLOW PROJECT NUMBER DATE CERTIFIED BY: REVISIONS ISSUE DRAWING © 2019 Halstead Architects All Rights Reserved- - - - - - - 100% CONSTRUCTION DOCUMENTS P9.1 20015Owner 09/01/2020 PLUMBING DETAILSSitara Indian Restaurant13080 GRAND BOULEVARDCARMEL, IN 4603212" = 1'-0" BACKFLOW PREVENTER1 12" = 1'-0" ICE MAKER WALL BOX2 12" = 1'-0" INLINE PUMP PIPING DETAIL3 12" = 1'-0" PIPE 4 AND SMALLER ANCHOR4 12" = 1'-0" PIPE ALIGNMENT GUIDE DETAIL5 12" = 1'-0" POTABLE HWR BALANCING VALVE STATION6 10/20/20