Loading...
HomeMy WebLinkAboutA2-1 - FLOOR PLAN & DETAILS24x3621x48 21x4221x42 21x42 21x42 21x48 21x48 21x36 21x48 21x48 24x48 GENERAL PLAN NOTES: 1. THESE DRAWINGS ARE INTENDED TO OUTLINE THE GENERAL SCOPE OF THE WORK. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE STARTING ANY WORK. CONTRACTORS SHALL ALSO BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE CODES AND GENERALLY ACCEPTED TRADE PRACTICES. CONTRACTOR SHALL REPORT ANY DISCREPANCIES OR OMISSIONS THAT MAY OCCUR TO THE ARCHITECT OR OWNER. 2. CONTRACTORS SHALL USE ACTUAL CONSTRUCTION DOCUMENTS FOR ANY AND ALL MATERIAL TAKE OFFS, BUDGETING, AND OTHER CONSTRUCTION SERVICES. ELECTRONIC MODELS (INCLUDING, BUT NOT LIMITED TO, REVIT AND AUTOCAD) ARE NOT CONSIDERED CONSTRUCTION DOCUMENTS. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS PRIOR TO SUBMITTING SHOP DRAWINGS, FABRICATION, OR INSTALLATION. 3. ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD, MASONRY, OR EXISTING WALL SURFACE, UNLESS NOTED OTHERWISE. 4. PROVIDE NECESSARY BLOCKING, CONCEALED WITHIN THE CONSTRUCTION, AS REQUIRED FOR ANY AND ALL ITEMS THAT MUST BE SECURED TO THE WALL. VERIFY LOCATIONS WITH OWNER. 5. REFER TO WINDOW & DOOR SCHEDULES ON SHEET A3.1 FOR SIZE, TYPE, AND FINISH OF ALL DOORS, FRAMES, AND WINDOWS. ALL DOOR FRAME OPENINGS SHALL BE 6" FROM ADJACENT WALLS UNLESS NOTED OTHERWISE. 6. REFER TO PLUMBING AND / OR SPECIALIZED EQUIPMENT PLANS FOR ALL PLUMBING FIXTURE AND EQUIPMENT LOCATIONS, SPECIFICATIONS, AND QUANTITIES. THE ARCHITECTURAL FLOOR PLANS ARE FOR ILLUSTRATING DESIGN INTENT ONLY. 7. REFER TO THE INTERIOR DESIGN DRAWINGS FOR ALL INTERIOR FINISH RELATED DESIGN ELEMENTS AND PRODUCT SPECIFICATIONS. EXISTING DOOR AND FRAME TO REMAIN NEW DOOR AND FRAME NEW INTERIOR PARTITION (SEE WALL TYPES) EXISTING CONSTRUCTION TO REMAIN WALL LEGEND 37'-11 1/2"16'-9"60'-0" VIF76'-9"1'-4" 13'-1" 36'-2 1/2"VIF VIF 24'-10 1/2" VIF 10'-0"VIF4'-8"VIF 40'-5" VIF33'-4"13'-1" VIF78'-5"A3.1 4 A3.1 5 A3.1 3 7'-10" 4 7/8" 6'-2" 4 7/8" 6'-4" 4 7/8"4'-0" 4 7/8"6'-4" 2'-4" 17'-0 1/2" 4 7/8" 7'-4" 4 7/8" 6'-0" 18'-0" 7'-8 7/8"4 7/8" 6'-2 1/8" 4 7/8"4'-3" 1'-1 5/8" 4 7/8" 8 1/2" 14'-3 1/8" 4 7/8" 7'-0 3/8" 1'-8" 4 7/8" 7'-5" 8 1/2" 10'-1 3/8" 4'-0" 2'-11 1/8" 4 7/8" 7'-4" 4 7/8" 5'-7 7/8" 7'-8 7/8" 28'-8 1/8"6 7 8 B C E F G H4'-8"18'-2 1/4" 15'-1 3/4" 37'-5" 1'-8" 7'-4" VEST. 101 LOBBY 102 COOLER 114 ALCOVE 104 PICK UP 107 WAIT STATION 108 SOUTH DINING 106 NORTH DINING 109 PRIVATE DINING 110 DISHWASHING 111 KITCHEN 112 STORAGE 113 28'-0"FOLDING WALL12 1 2 1 2 1 2 1 2 6 4 5 5 2 101 113103 105107A 109TLT 105 TLT 103 A8.1 1 810 9 11 12 13 13 9'-9 3/8" 4'-1 1/8" 1'-6" 4 7/8" 1'-8"4 7/8"9'-4" 4 7/8" 25'-2 1/4" 4 7/8" 7'-8" 144'-0" 1'-8" 8" 15S4.1AS4.1A S4.1AA8.16 S4.1A S4.1A S4.1A S4.1AS4.1AS4.1A S6.1A S6.1A S6.1A S4.1A S4.1AS4.5 S4.5 S4.5 S4.5 1'-10 5/8" 10 3/8" 2 1/4"S4.516 108A 108B S4.2S4.2A8.1 7107B 17 17 17 17 17 17 1818 19 19 20 21 22 23 A8.1 8 S6.1A 101A 24 INTERIOR WALL TYPES NOTES A. BOTTOM EDGE OF GYPSUM BOARD SHALL BE HELD ABOVE THE SLAB / SUBFLOOR A MINIMUM OF 1/2". B. IN A ROOM THAT DOES NOT HAVE A CEILING, THE GYPSUM BOARD SHALL EXTEND TO THE DECK ABOVE ON THE SIDE OF THE WALL WHERE THE CEILING IS NOT PRESENT. C. AT ALL WALLS SCHEDULED TO RECEIVE CERAMIC TILE, CONTRACTOR SHALL SUBSTITUTE GLASS MAT INTERIOR GYPSUM WALLBOARD FOR THE STANDARD GYPSUM WALLBOARD IDENTIFIED IN THE WALL TYPES. REFER TO ROOM FINISH SCHEDULE FOR LOCATIONS OF CERAMIC TILE. D. BRACE WALLS TO DECK OR TO B/ JOISTS AS REQUIRED BY FIELD CONDITIONS AND BY MANUFACTURER'S RECOMMENDATIONS E. USE MOISTURE RESISTANT GYP. BD. IN RESTROOMS, KITCHEN, AND ALL WET AREAS CONTINUOUS DEFLECTION TRACK ANCHORED TO EXISTING FLOOR SLAB/STRUCT ABOVE ROOF/CEILING/JOIST STRUCTURE WALL BASE. REFER TO ROOM FINISH SCHEDULE REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISH. FLOOR CONSTRUCTION VARIES -SEE PLANS CONTINUOUS 6" METAL STUD TRACK ANCHORED TO EXISTING FLOOR 6" METAL STUD FRAMING @ 16" O.C. (2) 5/8" TYPE X GYPSUM BOARD BOTH SIDES 1/2"HEAD PLAN BASE 'S6.1' CONTINUOUS DEFLECTION TRACK ANCHORED TO EXISTING FLR SLAB/STRUCTURE ABOVE ROOF/CEILING TRUSS/STRUCTURE PROVIDE "ZIP-STRIP" TRIM AT TOP EDGE OF GYPSUM BOARD WALL BASE. REFER TO ROOM FINISH SCHEDULE REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISH. FLOOR CONSTRUCTION VARIES -SEE PLANS CONTINUOUS 3 5/8" METAL STUD TRACK ANCHORED TO EXISTING FLOOR 3 5/8" METAL STUD FRAMING @ 16" O.C. 5/8" TYPE X GYPSUM BOARD U.N.O.1/2"HEAD PLAN BASE 'S4.1' 'S4.5'PROVIDE ALL COMPONENTS IDENTIFIED WITHIN WALL TYPE 'S4.1' WITH THE FOLLOWING EXCEPTIONS: • DELETE LAYER OF 5/8" GYPSUM BOARD ON CHASE SIDE OF WALL ASSEMBLY 'S6.1A' PROVIDE ALL COMPONENTS IDENTIFIED WITHIN WALL TYPE 'S6.1' WITH THE FOLLOWING EXCEPTIONS: • 6" MINERAL WOOL THERMAFIBER ACOUSTIC INSULATION, FRICTION FIT, FULL EXTENT OF CAVITY • ACOUSTICAL SEALANT BOTH SIDES AT ALL INTERSECTIONS OF GYPSUM BOARD, FLOOR SYSTEM AND LEG OF STEEL RUNNER. • LOCATE OUTLETS AND PENETRATIONS ON COMMON WALLS FACING ADJACENT SPACES AT 24" APART MINIMUM. • WALL PENETRATIONS, INCLUDING BUT NOT LIMITED TO THOSE FROM HVAC, PLUBMING AND ELECTRICAL SHALL BE INSULATED AND ACCOUSTICALLY SEALED. 'S4.1A'PROVIDE ALL COMPONENTS IDENTIFIED WITHIN WALL TYPE 'S4.1' WITH THE FOLLOWING EXCEPTIONS: • PROVIDE 3" MEDIUM-DENSITY FIBERGLASS BATT ACOUSTIC INSULATION, FRICTION FIT, FULL EXTENT OF CAVITY HARD LID ABOVE LID WALL BASE. REFER TO ROOM FINISH SCHEDULE REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISH. FLOOR CONSTRUCTION VARIES -SEE PLANS CONTINUOUS 3 5/8" METAL STUD TRACK ANCHORED TO EXISTING FLOOR 3 5/8" METAL STUD FRAMING @ 16" O.C. 5/8" TYPE X GYPSUM BOARD UNO 1/2" 'S4.2' U.N.O.6"KICKER BRACING TO STRUCTURE ABOVE 4 7/8" HEAD PLAN BASE 8 1/2" 4 7/8" CONTINUOUS DEFLECTION TRACK ANCHORED TO EXISTING FLOOR SLAB/STRUCTURE ABOVE ROOF/CEILING TRUSS/STRUCTURE CONTINUOUS SEALANT BEAD AT JUNCTURE OF GYPSUM BOARD AND FLOOR/CEILING ASSEMBLY WALL BASE. REFER TO ROOM FINISH SCHEDULE REFER TO ROOM FINISH SCHEDULE FOR FLOOR FINISH. FLOOR CONSTRUCTION VARIES -SEE PLANS CONTINUOUS 1 5/8" METAL STUD TRACK ANCHORED TO FLOOR 1 5/8" METAL STUD FRAMING @ 16" O.C. 5/8" TYPE X GYPSUM BOARD U.N.O. HEAD PLAN BASE ACOUSTIC WALL DETAIL 2 1/4" EXISTING WALL CONSTRUCTION VARIES, V.I.F.1/2"VARIES GYP. BRD. (TYP.) (SEE WALL TYPES) MINERAL WOOL INSULATION TYP) (SEE WALL TYPES) WALL BASE (SEE ROOM FINISH SCHEDULE) FLOOR FINISH MATERIAL (SEE ROOM FIN. SCHEDULE) CONCRETE SLAB METAL STUD FRAMING (SEE WALL TYPES) POWER DRIVEN FASTENERS @ 2'-0" O.C. MAX AND WITHIN 1" OF ENDS -- MAX. 7/8" EMBEDMENT ACOUSTIC SEALANT (CONT. AT ALL EDGES) ACOUSTIC SEALANT (CONT. PERIMETER OF OPENING) ELECTRICAL BOX (SPACE 24" APART MINIMUM -TYP) FLOOR PLAN KEYNOTES: 1. EXISTING FLOOR SLAB TO REMAIN. 2. NEW 4" SLAB ON GRADE OVER VAPOR BARRIER. 3. FOLDING WALL. REFER TO FINISH DRAWINGS FOR COLOR AND FACE MATERIAL. 4. OPERABLE EGRESS DOOR AS PART OF FOLDING WALL SYSTEM. 5. TUBE STEEL COLUMN FOR FOLDING WALL. THICKEN CONCRETE FLOOR SLAB 36"x36"x12" THICK. 6. STEEL BEAM ABOVE CEILING FOR MOUNTING OF FOLDING WALL. 7. FINISHED DRYWALL FULL HEIGHT AROUND PERIMETER OF EXISTING EXTERIOR WALLS. 8. REMOVE EXISTING DOOR & HARDWARE. SALVAGE FOR REUSE. INSTALL NEW 1" INSULATED, TEMPERED GLASS PANEL TO MATCH EXISTING. 9. REMOVE GLASS VISION PANEL AND INSTALL SALVAGED DOOR & HARDWARE. 10. REMOVE GLASS VISION PANEL AND INSTALL NEW DOOR & HARDWARE TO MATCH EXISTING (SEE SCHEDULE). 11. NEW GLASS AND ALUMINUM STOREFRONT WALL AND 36" DOOR & HARDWARE TO MATCH EXISTING. 12. ALIGN FACE OF WALL W/ EXISTING JAMB. 13. CENTER WALL W CENTER OF MULLION. 14. REMOVE EXISTING GLASS PANELS AND INSTALL NEW INSULATED PANELS WITH FRIT GLAZING. 15. ADDITIONAL 2 1/4" FURRED WALL 'S2.5' WITH RECESS ALONG THIS WALL. REFER TO INTERIOR ELEVATIONS FOR LOCATION AND SIZE OF RECESS. 16. PARTIAL HEIGHT GYPSUM BOARD AND 3 5/8" WALL W/ EMBEDDED STEEL TUBES AND SCREEN WALL CAP (SEE INTERIOR FINISH DRAWINGS). 17. 5/8" FINISHED DRYWALL AROUND INTERIOR SIDE OF EXISTING TENANT PERIMETER WALLS. 18. METAL STUD AND DRYWALL BULKHEAD OVER UPPER GLAZED PANELS AT THIS OPENING. 19. STC RATED ALUMINUM CLOSURE PANEL "MULLION MATE - SERIES 40 PLUS" BY GORDON ARCHITECTURAL + ENGINEERD SOLUTIONS. 20. WALL HUNG FIRE EXTINGUISHER TYPE K. LOCATE AS AGREED BY THE FIRE MARSHALL. 21. WALL HUNG FIRE EXTEINGUISHER TYPE ABC. LOCATE AS AGREED BY THE FIRE MARSHALL. 22. 5 LB TYPE ABC FIRE EXTINGUISHER AND SEMI RECESSED CABINET "AMBASSADOR 1017 SERIES" BY JL INDUSTRIES OR EQUAL. LOCATE AS AGREED BY THE FIRE MARSHALL. 23. VERIFY FIRE DEPARTMENT KNOX BOX EXISTS FOR TENTANT SPACE. IF NOT, THEN PROVIDE BOX AND LOCATE AS AGREED BY THE FIRE MARSHALL. 24. REPLACE EXISTING PUSH / PULL HARDWARE WITH PANIC EGRESS HARDWARE (SEE SCHEDULE) STATE OF 900019 No.MICHA E L W .HAL S T EADI ND I A N AREGISTER E DA RCH I T E C T PROJECT NUMBER DATE 1139 SHELBY STREET INDIANAPOLIS, IN 46203 317.684.1431 CERTIFIED BY: 123 EAST THIRD ST. MARION, INDIANA 46952 765.662.9372 www.halstead-architects.com REVISIONS ISSUE DRAWING © 2019 Halstead Architects All Rights ReservedREV 1 - CARMEL PLAN REVIEW -10/14/2020 - - - - - - 100% CONSTRUCTION DOCS. -09/01/2020HAMILTON COUNTY | CLAY TOWNSHIPA2.1 2026INTERIOR TENANT FINISH FORSEPTEMBER 1, 2020 FIRST FLOOR PLAN & DETAILSSITARA INDIAN CUISINE13080 GRAND BLVDCARMEL, INDIANA 46032SCALE: 1/4" = 1'-0" 1 FIRST FLOOR PLAN 1 1 10/20/20