Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E3-1 - POWER & SYSTEMS FLOOR PLANS
24x3621x48 21x4221x42 21x4221x42 21x48 21x48 21x36 21x48 21x48 24x48F J J J J J J J J J J J J J B C E F G H 6 7 8 A -52 A -52 A -52 A -52 A -52 A -52 A -52 A -52 A -52 A -56 A -46 4 23 20 16.1 A EWH-1 DWH-1 A -32 A -34 A -37 A -38 A -40 A -39 A -39 A -36 A -43 24 A -41 37.1 36 A -23 A -27,29 A -13,15,17 3 A -42 33 A -31,33 A -48 A -48 30.2 30.3 14.2 14.1 16.2 A -50 A -45 15 A -54 A -49 A -49 WP WP WP A -47 A -47 A -47 37.2 A -57,59 13.1 A -25 A -44 A -55 18.1 18.2 A -60 A-60 6 6 7 7 8 8 B B C C E E F F G G H H A -62 A -64 6 6 A -66 A. SEE SHEET E0.1 FOR SYMBOLS AND ABBREVIATIONS. B. SEE SHEET E0.2 FOR ELECTRICAL SPECIFICATIONS. C. SEE SHEETS E8.1 FOR PANEL SCHEDULES. D. SEE SHEETS E9.1, E9.2, AND E9.3 FOR ELECTRICAL DETAILS. E. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR UNLESS NOTED OTHERWISE. USE SOLID CONDUCTOR FOR SIZE #10 AWG AND SMALLER. USE STRANDED CONDUCTOR FOR LARGER SIZES. MC CABLE SHALL NOT BE SURFACE MOUNTED IN FINISHED SPACES. F. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE WHITE IN COLOR. G. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT. H. CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO BUILDING LINES. OBTAIN PERMISSION FROM ARCHITECT PRIOR TO INSTALLATION. I. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. J. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND RAIN TIGHT. K. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL INTERCONNECT WIRING FOR MECHANICAL AND PLUMBING EQUIPMENT FURNISHED BY OTHERS. GENERAL SHEET NOTES B C E F G H 6 7 8 RTU-2 RTU-3 RTU-1 A -1,3,5 A -2,4,6 A -7,9,11 EF-1 KEF-1 MUA-1 A -35A -18,20,22 A -10,12,14 COOLER CONDENSER A -19,21 14.5 14.3 14.4 KEF-2 A -24,26,28 30.1 6 6 7 7 8 8 B B C C E E F F G G H H PROJECT NUMBER DATE CERTIFIED BY: REVISIONS ISSUE DRAWING © 2019 Halstead Architects All Rights Reserved- - - - - - - 100% CONSTRUCTION DOCUMENTS E3.1 20015Owner 09/01/2020 POWER & SYSTEMS FLOOR PLANSSitara Indian Restaurant13080 GRAND BOULEVARDCARMEL, IN 46032SCALE: 1/8" = 1'-0" 1 First Floor Plan -Power & Systems SCALE: 1/8" = 1'-0" 2 ROOF PLAN -Power & Systems SHEET KEYNOTES 1 MOUNT CENTER OF DEVICE +3'-6" ABOVE FINISHED FLOOR. 2 MOUNT CENTER OF DEVICE +5'-0" ABOVE FINISHED FLOOR. 3 MOUNT CENTER OF DEVICE 6" ABOVE TOP OF TABLE. 4RECESSED FLOOR BOX WITH SINGLE DUPLEX RECEPTACLE. HUBBELL #RF400 WITH #RF406BP COVER. 5 RECESSED FLOOR BOX WITH "FURNITURE FEED" COVER IN BRONZE. 6 POWER CONNECTION FOR FUTURE BUILDING SIGNAGE. VERIFY FINAL LOCATION IN FIELD WITH OWNER PRIOR TO ROUGH-IN. 1 1 2 23 3 4 5 10/20/20