Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E8-1 - ELECTRICAL SCHEDULES
NOTES: 1. INSTALL OVERCURRENT PROTECTION AND BRANCH CIRCUITS PER UL LISTED REQUIREMENTS FOR EQUIPMENT SERVED. REFER TO EQUIPMENT CUT SHEETS AND MANUFACTURER'S DATA FOR ROUGH-IN LOCATIONS OF ELECTRICAL CONNECTIONS AND INTERCONNECTIONS FOR ALL EQUIPMENT. PROVIDE DISCONNECT SWITCH (NON-FUSED, UNLESS NOTED OTHERWISE). COORDINATE EXACT NAMEPLATE DATA OF EQUIPMENT TO BE USED WITH DIVISION 15. 2. PROVIDE WP DEVICES (NEMA 3R RATING) IN ALL EXTERIOR OR DAMP LOCATIONS. 3. COORDINATE AND CONNECT DUCT SMOKE DETECTORS AND ASSOCIATED WIRING WHERE REQUIRED BY DOCE. 4. MAGNETIC STARTER PROVIDED WITH EQUIPMENT. 5. PROVIDE MAGNETIC STARTER FOR CONTROL INTERFACE. 6. DISCONNECT PROVIDED WITH EQUIPMENT. 7. PROVIDE DUPLEX RECEPTACLE AT UNIT PER REQUIREMENT OF NEC 210-63. EXTEND AND CONNECT TO COMMON 120V BRANCH CIRCUIT. PROJECT NUMBER DATE CERTIFIED BY: REVISIONS ISSUE DRAWING © 2019 Halstead Architects All Rights Reserved- - - - - - - 100% CONSTRUCTION DOCUMENTS E8.1 20015Owner 09/01/2020 ELECTRICAL SCHEDULESSitara Indian Restaurant13080 GRAND BOULEVARDCARMEL, IN 46032LIGHTING FIXTURE SCHEDULE FIXTURE TYPE BASE MANUFACTURER EQUAL MANUFACTURER LAMPING WATTAGE VOLTS MOUNTING DESCRIPTION A A1 CONTECH LIGHTING CLT8071M3DP LED 1150LM 3500K 15W 120 TRACK LED TRACK HEAD A2 CONTECH LIGHTING CTL182V3DP LED 4700LM 3500K 36W 120 TRACK LED TRACK HEAD B1 LUMENWERX VIA2R-HLO-FH-LED-QUADRO-3WF-16FT-120-0-10-1-XX-W 48W 120 RECESSED 16' RECESSED LINEAR LED B2 LUMENWERX VIA2R-HLO-FH-LED-QUADRO-3WF-6FT-120-0-10-1-XX-W 18W 120 RECESSED 6' RECESSED LINEAR LED B3 LUMENWERX VIA2R-HLO-FH-LED-QUADRO-3WF-8FT-120-0-10-1-XX-W 24W 120 RECESSED 8' RECESSED LINEAR LED C CALIBER PLUS C85 P V 20 35K M L9 XX M LED 2015LM 3500K 15.8W 120 PENDANT CYLINDER PENDANT MOUNT LED DOWNLIGHT D HALO PRS4 40 DLV SM4 34 8FS 41S MD H XX XX TIR4SMD LED 4000LM 3500K 39.8W 120 RECESSED 4" SQUARE LED DOWNLIGHT DE HALO PRS4 40 DLV REMV14 SM4 34 4"8FS 41S MD H XX XX TIR4SMD LED 4000LM 3500K 39.8W 120 RECESSED 4" SQUARE LED DOWNLIGHT WITH EMERGENCY MODULE AND REMOTE TEST E JUSTICE DESIGN GROUP FAB-9594 (8) 9W LED A-19 72W 120 PENDANT 36" LED DRUM PENDANT F DUTTON BROWN COLOR CAP DOUBLE SCONCE 6" (2) 9W LED A19 18W 120 WALL 6" DOUBLE LED SCONCE; COLOR ORANGE WITH NICKEL FINISH AND WHITE GLOBE G LUMINII LED 50W 120 WALL H1 BASELITE UCD14 XX-XX-XX-XX-25W-35K-LDM0-10 LED 1900LM 3500K 25W 120 PENDANT PENDANT HUNG LED 14.5"X14.5" H2 BASELITE UCD16 XX-XX-XX-XX-25W-35K-LDM0-10 LED 1900LM 3500K 25W 120 PENDANT PENDANT HUNG LED 10.75"X16" H3 BASELITE UCD20 XX-XX-XX-XX-25W-35K-LDM0-10 LED 1900LM 3500K 25W 120 PENDANT PENDANT HUNG LED 8.5"X20" I METALUX 24CGT5550C LED 5337LM 5000K 46.8W 120 LAY-IN 2X4 LED FLAT PANEL IE METALUX 24CGT5550CEBPLED14W LED 5337LM 5000K 46.8W 120 LAY-IN 2X4 LED FLAT PANEL WITH EMERGENCY BATTERY X1 EVENLITE: TCXCOM-R-U-W-TCRH2 LED W/2 1.5W LED FLOODS 2.4W MVOLT UNIVERSAL COMBINATION EXIT SIGN/EMERGENCY EGRESS LIGHT X2 EVENLITE: TCXCOM-R-U-W-TCRH2-PRWLED2-MV LED WITH (2) INTEGRAL W LED FLOODS AND (2) REMOTE 1.0W LED FLOODS 2.4W MVOLT UNIVERSAL COMBINATION EXIT SIGN/EMERGENCY EGRESS LIGHT WITH REMOTE HEAD ELECTRICAL CONNECTION TO MECHANICAL AND PLUMBING EQUIPMENT SCHEDULE UNIT ID FLA HP KW MCA VOLTS PHASE BREAKER SIZE CONDUIT WIRE GRD CONTROLLER DISCONNECT SWITCH CONNECTION TYPE NOTES EF-1 120 1 20A 3/4" #12 #12 20A-1P 1,2 EWH-1 15 A 1.8 120 1 20A 3/4" #12 #12 1 RTU-1 37.0 208 3 60A 1" #6 #10 1,3,6 RTU-2 48.0 208 3 60A 1" #6 #10 1,3,6 RTU-3 48.0 208 3 60A 1" #6 #10 1,3,6 Notes: L 0.2 kVA 100.00% 0.2 kVA Receptacle 0.7 kVA 100.00% 0.7 kVA Power 1.5 kVA 100.00% 1.5 kVA Total Est. Demand: 265 A Other 2.5 kVA 100.00% 2.5 kVA Total Conn.: 299 A Lighting 9.7 kVA 125.00% 12.1 kVA Total Est. Demand: 95.5 kVA Kitchen Equipment - Non-Dwelling Unit 42.0 kVA 65.00% 27.3 kVA Total Conn. Load: 107.7 kVA HVAC 51.3 kVA 100.00% 51.3 kVA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: * = GROUND FAULT CIRCUIT BREAKER Total Amps: 302 A 299 A 297 A Total Load: 36.2 kVA 35.9 kVA 35.7 kVA 83 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 84 81 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 82 79 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 80 77 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 78 75 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 76 73 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 74 71 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 72 69 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 70 67 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 68 65 Spare 20 A 1 0.0 kVA 0.2 kVA 1 20 A LC-1 CONTROL POWER 66 63 Spare 20 A 1 0.0 kVA 1.0 kVA 1 20 A NORTH BUILDING SIGN 64 61 Spare 20 A 1 0.0 kVA 1.0 kVA 1 20 A SOUTH BUILDING SIGN 62 59 -- -- -- 2.5 kVA 1.8 kVA 1 20 A VESTIBULE WALL HEATER 60 57 SOUTH HOT FOOD WELL 20 A 2 2.5 kVA 0.4 kVA 1 20 A HOSTESS STAND RECEPTACLE 58 55 SOUTH HEAT LAMP 30 A 1 2.4 kVA 0.8 kVA 1 20 A * REACH-IN COOLER 56 53 Lighting 20 A 1 0.8 kVA 0.8 kVA 1 20 A * REACH-IN COOLER 54 51 Lighting 20 A 1 0.2 kVA 1.6 kVA 1 20 A DINING CONVENIENCE RECEPTACLES 52 49 KITCHEN CONVENIENCE RECEPTACLES 20 A 1 0.4 kVA 0.8 kVA 1 20 A * NORTH MEGA TOP SANDWICH/SALAD PRE... 50 47 OUTDOOR RECEPTACLES 20 A 1 0.5 kVA 0.4 kVA 1 20 A KITCHEN CONVENIENCE RECEPTACLES 48 45 * SOUTH MEGA TOP SANDWICH/SALAD PRE... 20 A 1 0.8 kVA 0.4 kVA 1 20 A * BACK BAR REFRIGERATED CABINET 46 43 WALK-IN COOLER LIGHTS 20 A 1 0.2 kVA 2.4 kVA 1 30 A NORTH HEAT LAMP 44 41 * REACH-IN FREEZER 20 A 1 1.7 kVA 0.2 kVA 1 20 A * FOOD WASTE DISPOSER 42 39 RESTROOM RECEPTACLES 20 A 1 0.4 kVA 0.3 kVA 1 20 A DWH-1 40 37 DWH-1 20 A 1 0.5 kVA 0.5 kVA 1 20 A DWH-1 38 35 EF-1 20 A 1 0.1 kVA 1.0 kVA 1 20 A WALK-IN COOLER EVAPORATOR 36 33 -- -- -- 1.1 kVA 0.3 kVA 1 20 A ANSUL SYSTEM POWER 34 31 ICE MAKER 20 A 2 1.1 kVA 0.5 kVA 1 20 A KITCHEN HOOD LIGHTS 32 29 -- -- -- 2.5 kVA 0.2 kVA 1 20 A SHUNT TRIP - KITCHEN HOOD LIGHTS 30 27 MOBILE BUFFET RECEPTACLE 30 A 2 2.5 kVA 0.3 kVA -- -- -- 28 25 FRENCH FRY WARMER * 20 A 1 0.8 kVA 0.3 kVA -- -- -- 26 23 BUFFETT - COLD SECTION * 20 A 1 1.4 kVA 0.3 kVA 3 15 A KEF-2 24 21 -- -- -- 2.4 kVA 0.3 kVA -- -- -- 22 19 WALK-IN COOLER CONDENSER 30 A 2 2.4 kVA 0.3 kVA -- -- -- 20 17 -- -- -- 4.6 kVA 0.3 kVA 3 15 A KEF-1 18 15 -- -- -- 4.6 kVA 0.6 kVA 1 20 A Lighting 16 13 DISH MACHINE 60 A 3 4.6 kVA 0.5 kVA -- -- -- 14 11 -- -- -- 4.4 kVA 0.5 kVA -- -- -- 12 9 -- -- -- 4.4 kVA 0.5 kVA 3 15 A MUA-1 10 7 RTU-1 60 A 3 4.4 kVA 0.9 kVA 1 20 A Lighting 8 5 -- -- -- 5.8 kVA 5.8 kVA -- -- -- 6 3 -- -- -- 5.8 kVA 5.8 kVA -- -- -- 4 1 RTU-2 60 A 3 5.8 kVA 5.8 kVA 3 60 A RTU-3 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: * = GROUND FAULT PROTECTED CIRCUIT BREAKER Enclosure: Type 1 MCB Rating: 400 A Mounting: Surface Wires: 4 Mains Rating: 400 A Supply From: Phases: 3 Mains Type: MCB Location: STORAGE 113 Volts: 120/208 Wye A.I.C. Rating: Branch Panel:A 10/20/20