Loading...
HomeMy WebLinkAboutA000.7MIN. 22 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "C" MIN. 303 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "A" MIN. 16 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"MIN. 40 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "E" PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION POT VENTS GUTTER AND DOWNSPOUTS \A1;1'-0"\PTYP. \A1;8'-0{\H0.75x;\S1#4;}" \A1;10'-6" \A1;14'-0" \A1;7'-0" \A1;12'-0" \A1;7'-0" 3.5:12 10:12 10:12 8:12 8:128:12 10:12 10:1210:12 3.5:12 8:128:12 3.5:12 10:12 10:12 8:12 10:12 7:12 8:12 8:12 "A" 2434ROOF AREA: SQ. FT. 10:12 8:12 "B" 498ROOF AREA: SQ. FT.10:12 10:12ELEVATION HR2VATTIC VENT SCHEDULEVENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATIONROOF AREA "A"SQ FTG2512AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY3.354.194.2450.00100AT EAVE5.024.194.2450.00061.00TOTAL (MIN)8.378.378.47100.003 HIGH -RIDGE VENT3.354.194.1348.930033.00AT EAVE5.024.194.3151.07062.00TOTAL (MIN)8.378.378.43100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEELEVATION HR2VROOF AREA "B"SQ FTG498AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.660.830.8548.4120AT EAVE1.000.830.9051.59013.00TOTAL (MIN)1.661.661.75100.003 HIGH -RIDGE VENT0.660.830.8849.22007.00AT EAVE1.000.830.9050.78013.00TOTAL (MIN)1.661.661.78100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEA4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Skyview 2056.300Home for * Market Home *, 7231-003002459 Towne Meadow Drive, Carmel, IN 46032ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) 10/19/20