HomeMy WebLinkAboutA1.1 Proposed Floor PlanEXISTING FIRE WALL
ELECTRICAL PANEL
UNIT 116
NOT IN SCOPE
1,215 SF
NON-SPRINKLERED
UTILITIES
108
UNIT 118
1,172 SF
NON-SPRINKLERED
+11'-11 3/8"
RAFTERS60'-9 1/2"39'-5 1/2"
ELECTRICAL PANEL
LOBBY
100
RECEPTION
101
OFFICE
102
HALL
103
OFFICE
104
HALL
105
CONFERENCE
106
STORAGE
107
OFFICE
OFFICE
STORAGE
UNIT 120
NOT IN SCOPE
2,487 SF
NON-SPRINKLERED
LOBBY
OPEN OFFICE
100
10
7
10
8
106104102
7'-10 1/2"7'-10 1/2"
3'-7"12'-4 1/8" 3'-7"
19'-6 1/8"
7'-1"3'-1 3/8"6'-3 1/8" 7'-10" 10'-3"3'-9 1/8" 3'-9" 20'-10 1/2" 8'-8 3/4"P2
P2
P2
P3 P31
A3.0
2
A3.0
2
A3.0
TYP.
2"x4" WOOD STUDS @ 16" O.C. WITH SOUND BATT AND
5/8" GYPSUM WALLBOARD EACH SIDE. EXTEND STUDS AND
GYPSUM WALLBOARD TO UNDERSIDE OF ROOF JOISTS,
UNLESS OTHERWISE NOTED. USE WATER RESISTANT
GYPSUM WALL BOARD AT ALL WET WALL LOCATIONS.
*ALL WALLS P1 UNLESS OTHERWISE NOTED
TYPICAL PARTITIONP1
1- HR FIRE RATED PARTITIONP2
6 3/4"2"x4" WOOD STUDS @ 16" O.C. WITH 5/8" GYPSUM
WALLBOARD EACH SIDE. EXTEND STUDS AND GYPSUM
WALLBOARD TO 3'-0" AFF, UNLESS OTHERWISE NOTED.
USE WATER RESISTANT GYPSUM WALL BOARD AT ALL
WET WALL LOCATIONS.
KNEE WALLP3 4 3/4" 4 3/4"2"x6" WOOD STUDS @ 16" O.C. WITH SOUND BATT AND
5/8" TYPE 'X' GYPSUM WALLBOARD EACH SIDE. EXTEND
STUDS AND GYPSUM WALLBOARD TO UNDERSIDE OF ROOF
JOISTS. USE WATER RESISTANT GYPSUM WALL BOARD AT
ALL WET WALL LOCATIONS.DOORNUMBERWIDTHHEIGHTFAMILY AND TYPE ELEVATIONMATERIALNOTES
SIZE
DOOR FRAME
DOOR & FRAME SCHEDULE
102 ELEVATION3'-0" 1 3/4"
1 3/4" 104 3'-0"THICKDOOR TYPES:
1. DOOR: HINGED SLAB. FRAME: WOOD, PAINTED, OWNER TO SELECT FROM FULL RANGE OF COLORS
2. DOOR: SOLID CORE WOOD POCKET W/ FULL-LITE FROSTED GLASS PANEL. FRAME: WOOD, PAINTED
106 1 3/4"
107
108
3'-0" GLASS100 Existing to RemainDOOR TYPEF1
F1
HARDWARE SCHEDULE
2
HARDWARE SET #1:
PRIVACY SET: SCHLAGE
SATURN AL80PD
CYLINDRICAL
STOREROOM LOCK
FINISH: 626 SATIN
HINGES: STANLEY / BEST
4 1/2" x 4 1/2"
FULL MORTISE
CB179 HARDWAREHARDWARE SET #2:
PRIVACY SET: SCHLAGE
SATURN AL70PD
OFFICE LOCK
FINISH: 626 SATIN
HINGES: STANLEY / BEST
4 1/2" x 4 1/2"
FULL MORTISE
CB179
1
2 6'-8" SCW Pocket/ Single-Flush
D1
D2
WD
WD#2
#1
Existing to Remain
Existing to Remain
Hinged Slab/ Single-Flush
F1SCW Pocket/ Single-Flush D2 WD#2 6'-8"
6'-8" 6'-8"3'-0"6'-8"3'-0"
DOOR 1 (D1) DOOR 2 (D2)
3'-4"6'-8" FRAME 1 (F1)
2"2" MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO.
JOB NO.
SCOPE DOCUMENT
THE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE
MAJOR ARCHITECTURAL ELEMENTS AND
THE TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL
SYSTEMS. AS SCOPE DOCUMENTS, THE
DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK THAT
IS REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT
DOCUMENTS. ON THE BASIS OF THE
GENERAL SCOPE INDICATED OR
DESCRIBED, THE TRADE CONTRACTORS
SHALL FURNISH ALL ITEMS REQUIRED
FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY
ONLY TO THE DOCUMENT TO WHICH
THEY ARE AFFIXED AND WE EXPRESSLY
DISCLAIM ANY RESPONSIBILITY FOR ALL
OTHER PLANS, SPECIFICATIONS,
ESTIMATES, REPORTS, OR OTHER
DOCUMENTS OR INSTRUMENTS
RELATING TO OR INTENDED TO BE USED
FOR ANY PART OR PARTS OF THE
PROJECT.
COPYRIGHT 2020 HOLDER DESIGN, INC.
REVISIONS
A20-020 SHEET DESCRIPTION: -24 South 5th Street
Terre Haute, Indiana
47807
ph. 812.235.1300
www.holderdesign.net
HOLDERDESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:PROPOSED FLOOR PLANAMA1.1
KEY:
DEMO
EXISTING PARTITIONS TO REMAIN
NEW STUD PARTITIONS
GENERAL NOTES:
PARTITION TYPES:
PARTITIONS ARE DIMENSIONED FROM FACE OF STUD OR MASONRY, UNLESS NOTED OTHERWISE. REFER TO WALL
TYPES FOR PARTITION THICKNESS.
PROVIDE WOOD BLOCKING SUPPORT AT ALL SURFACE MOUNTED ITEMS MOUNTED TO FACE OF DRYWALL.
PROVIDE MISCELLANEOUS METAL SUPPORTS FOR ALL CEILING SUPPORTED ITEMS.
ALL PLUMBING FIXTURES TO BE LOCATED IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL CODES.
CAULK ALL TOILET FIXTURES TO WALL USING CLEAR SILICONE SEALANT.
PROVIDE WATER RESISTIVE DRYWALL IN ALL WET LOCATIONS.
PROVIDE MISCELLANEOUS METAL SUPPORTS FOR ALL CEILING SUPPORTED ITEMS.
PROVIDE AND INSTALL FIRE EXTINGUISHERS AND OR CABINETS, OWNER APPROVED, AS REQUIRED BY ALL
APPLICABLE CODES
FEC CABINETS TO BE MOUNTED SO THE EXTINGUISHER HANDLE TO BE AT 48" A.F.F.
PROVIDE AND INSTALL PANIC HARDWARE AND ALL RELATED COMPONENTS AT ALL LOCATIONS REQUIRED BY
LOCAL, STATE AND FEDERAL CODES.
FIELD VERIFY ALL DIMENSIONS. FIELD VERIFY AND COORDINATE WITH ALL EXISTING CONDITIONS.
A1.1 SCALE: 1/4" = 1'-0"
1 PROPOSED FLOOR PLAN
N
10/23/20