Loading...
HomeMy WebLinkAboutA1.1 Proposed Floor PlanEXISTING FIRE WALL ELECTRICAL PANEL UNIT 116 NOT IN SCOPE 1,215 SF NON-SPRINKLERED UTILITIES 108 UNIT 118 1,172 SF NON-SPRINKLERED +11'-11 3/8" RAFTERS60'-9 1/2"39'-5 1/2" ELECTRICAL PANEL LOBBY 100 RECEPTION 101 OFFICE 102 HALL 103 OFFICE 104 HALL 105 CONFERENCE 106 STORAGE 107 OFFICE OFFICE STORAGE UNIT 120 NOT IN SCOPE 2,487 SF NON-SPRINKLERED LOBBY OPEN OFFICE 100 10 7 10 8 106104102 7'-10 1/2"7'-10 1/2" 3'-7"12'-4 1/8" 3'-7" 19'-6 1/8" 7'-1"3'-1 3/8"6'-3 1/8" 7'-10" 10'-3"3'-9 1/8" 3'-9" 20'-10 1/2" 8'-8 3/4"P2 P2 P2 P3 P31 A3.0 2 A3.0 2 A3.0 TYP. 2"x4" WOOD STUDS @ 16" O.C. WITH SOUND BATT AND 5/8" GYPSUM WALLBOARD EACH SIDE. EXTEND STUDS AND GYPSUM WALLBOARD TO UNDERSIDE OF ROOF JOISTS, UNLESS OTHERWISE NOTED. USE WATER RESISTANT GYPSUM WALL BOARD AT ALL WET WALL LOCATIONS. *ALL WALLS P1 UNLESS OTHERWISE NOTED TYPICAL PARTITIONP1 1- HR FIRE RATED PARTITIONP2 6 3/4"2"x4" WOOD STUDS @ 16" O.C. WITH 5/8" GYPSUM WALLBOARD EACH SIDE. EXTEND STUDS AND GYPSUM WALLBOARD TO 3'-0" AFF, UNLESS OTHERWISE NOTED. USE WATER RESISTANT GYPSUM WALL BOARD AT ALL WET WALL LOCATIONS. KNEE WALLP3 4 3/4" 4 3/4"2"x6" WOOD STUDS @ 16" O.C. WITH SOUND BATT AND 5/8" TYPE 'X' GYPSUM WALLBOARD EACH SIDE. EXTEND STUDS AND GYPSUM WALLBOARD TO UNDERSIDE OF ROOF JOISTS. USE WATER RESISTANT GYPSUM WALL BOARD AT ALL WET WALL LOCATIONS.DOORNUMBERWIDTHHEIGHTFAMILY AND TYPE ELEVATIONMATERIALNOTES SIZE DOOR FRAME DOOR & FRAME SCHEDULE 102 ELEVATION3'-0" 1 3/4" 1 3/4" 104 3'-0"THICKDOOR TYPES: 1. DOOR: HINGED SLAB. FRAME: WOOD, PAINTED, OWNER TO SELECT FROM FULL RANGE OF COLORS 2. DOOR: SOLID CORE WOOD POCKET W/ FULL-LITE FROSTED GLASS PANEL. FRAME: WOOD, PAINTED 106 1 3/4" 107 108 3'-0" GLASS100 Existing to RemainDOOR TYPEF1 F1 HARDWARE SCHEDULE 2 HARDWARE SET #1: PRIVACY SET: SCHLAGE SATURN AL80PD CYLINDRICAL STOREROOM LOCK FINISH: 626 SATIN HINGES: STANLEY / BEST 4 1/2" x 4 1/2" FULL MORTISE CB179 HARDWAREHARDWARE SET #2: PRIVACY SET: SCHLAGE SATURN AL70PD OFFICE LOCK FINISH: 626 SATIN HINGES: STANLEY / BEST 4 1/2" x 4 1/2" FULL MORTISE CB179 1 2 6'-8" SCW Pocket/ Single-Flush D1 D2 WD WD#2 #1 Existing to Remain Existing to Remain Hinged Slab/ Single-Flush F1SCW Pocket/ Single-Flush D2 WD#2 6'-8" 6'-8" 6'-8"3'-0"6'-8"3'-0" DOOR 1 (D1) DOOR 2 (D2) 3'-4"6'-8" FRAME 1 (F1) 2"2" MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO. JOB NO. SCOPE DOCUMENT THE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS AND THE TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK THAT IS REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY ONLY TO THE DOCUMENT TO WHICH THEY ARE AFFIXED AND WE EXPRESSLY DISCLAIM ANY RESPONSIBILITY FOR ALL OTHER PLANS, SPECIFICATIONS, ESTIMATES, REPORTS, OR OTHER DOCUMENTS OR INSTRUMENTS RELATING TO OR INTENDED TO BE USED FOR ANY PART OR PARTS OF THE PROJECT. COPYRIGHT 2020 HOLDER DESIGN, INC. REVISIONS A20-020 SHEET DESCRIPTION: -24 South 5th Street Terre Haute, Indiana 47807 ph. 812.235.1300 www.holderdesign.net HOLDERDESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:PROPOSED FLOOR PLANAMA1.1 KEY: DEMO EXISTING PARTITIONS TO REMAIN NEW STUD PARTITIONS GENERAL NOTES: PARTITION TYPES: PARTITIONS ARE DIMENSIONED FROM FACE OF STUD OR MASONRY, UNLESS NOTED OTHERWISE. REFER TO WALL TYPES FOR PARTITION THICKNESS. PROVIDE WOOD BLOCKING SUPPORT AT ALL SURFACE MOUNTED ITEMS MOUNTED TO FACE OF DRYWALL. PROVIDE MISCELLANEOUS METAL SUPPORTS FOR ALL CEILING SUPPORTED ITEMS. ALL PLUMBING FIXTURES TO BE LOCATED IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL CODES. CAULK ALL TOILET FIXTURES TO WALL USING CLEAR SILICONE SEALANT. PROVIDE WATER RESISTIVE DRYWALL IN ALL WET LOCATIONS. PROVIDE MISCELLANEOUS METAL SUPPORTS FOR ALL CEILING SUPPORTED ITEMS. PROVIDE AND INSTALL FIRE EXTINGUISHERS AND OR CABINETS, OWNER APPROVED, AS REQUIRED BY ALL APPLICABLE CODES FEC CABINETS TO BE MOUNTED SO THE EXTINGUISHER HANDLE TO BE AT 48" A.F.F. PROVIDE AND INSTALL PANIC HARDWARE AND ALL RELATED COMPONENTS AT ALL LOCATIONS REQUIRED BY LOCAL, STATE AND FEDERAL CODES. FIELD VERIFY ALL DIMENSIONS. FIELD VERIFY AND COORDINATE WITH ALL EXISTING CONDITIONS. A1.1 SCALE: 1/4" = 1'-0" 1 PROPOSED FLOOR PLAN N 10/23/20