Loading...
HomeMy WebLinkAboutA2.0 Reflected Ceiling PlanEXISTING FIRE WALL ELECTRICAL PANEL UNIT 116 NOT IN SCOPE 1,215 SF NON-SPRINKLERED UTILITIES 108 UNIT 118 1,172 SF NON-SPRINKLERED +11'-11 3/8" RAFTERS ELECTRICAL PANEL LOBBY 100 RECEPTION 101 OFFICE 102 HALL 103 OFFICE 104 HALL 105 CONFERENCE 106 STORAGE 107 R RR R RR R R R R R R R RR R R R R R R R R R R R R R R R OFFICE OFFICE STORAGE UNIT 120 NOT IN SCOPE 2,487 SF NON-SPRINKLERED LOBBY OPEN OFFICE +9'-4" ACT +9'-4" ACT +9'-4" ACT +9'-4" ACT +9'-4" ACT +9'-4" ACT MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO. JOB NO. SCOPE DOCUMENT THE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS AND THE TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK THAT IS REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY ONLY TO THE DOCUMENT TO WHICH THEY ARE AFFIXED AND WE EXPRESSLY DISCLAIM ANY RESPONSIBILITY FOR ALL OTHER PLANS, SPECIFICATIONS, ESTIMATES, REPORTS, OR OTHER DOCUMENTS OR INSTRUMENTS RELATING TO OR INTENDED TO BE USED FOR ANY PART OR PARTS OF THE PROJECT. COPYRIGHT 2020 HOLDER DESIGN, INC. REVISIONS A20-020 SHEET DESCRIPTION: -24 South 5th Street Terre Haute, Indiana 47807 ph. 812.235.1300 www.holderdesign.net HOLDERDESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:REFLECTED CEILING PLANA2.0 A2.0 SCALE: 1/4" = 1'-0" 1 REFLECTED CEILING PLAN N 45 ATTACHED AT STARTING AND ONE ADJACENT RUNNERS AT WALLS WALL TYPICAL CEILING BRACING CLEARANCE AT OPPOSITE WALLS (NOT ATTACHED) 2" MAX MAIN RUNNER 8" MAX No.12 GAGE SPLY WIRES VERTICAL ANGLE = 45 8" MAX 3/8" MIN. 2" MAX 45 45 45 3/8" MIN. 2" MAX SUSPENDED CEILING SYSTEM NOTES: A. SUSPENSION SYSTEM COMPONENTS: 1. ONLY INTERMEDIATE AND HEAVY-DUTY SYSTEMS MAY BE USED. 2. MAIN RUNNERS AND CROSS RUNNERS OF THE CEILING GRID SYSTEMS AND THEIR SPLICES AND INTERSECTION CONNECTIONS SHALL SUPPORT NOT LESS THAN 60 lbs. DESIGN LOAD IN TENSION AND COMPRESSION. ACCEPTABLE TEST RESULTS SHALL SHOW ULTIMATE LOADS AVERAGING NO LESS THAN 120 lbs. B. SUSPENSION SYSTEM APPLICATION: 1. MAIN RUNNERS AND CROSS RUNNERS SHALL BE ATTACHED TO THE PERIMETER MEMBERS ON TWO (2) ADJACENT WALLS. A CLEARANCE OF 1/4" SHALL BE MAINTAINED BETWEEN THE MAIN RUNNERS AND CROSS RUNNERS AND THE PERIMETER MEMBERS ON THE TWO REMAINING WALLS. 2. SUSPENSION WIRES SHALL BE SPACED ALONG EACH MAIN RUNNER IN ACCORDANCE WITH THE LOAD CARRYING CAPACITY OF THE SYSTEM AND SHALL BE A MINIMUM OF No. 12 GAGE (2.05 mm) SOFT ANNEALED GALVANIZED STEEL WIRE. 3. EACH VERTICAL WIRE SHALL BE ATTACHED TO THE CEILING SUSPENSION MEMBER WITH A MINIMUM OF THREE (3) TURNS AND TO THE STRUCTURE ABOVE WITH A CONNECTION CAPABLE OF CARRYING NOT LESS THAN A 100 lb. ALLOWABLE LOAD. THE POINTS OF HANGER WIRE SUPPORTS SHALL NOT PERMIT DISENGAGEMENT THROUGH VERTICAL LIFTING. 4. SUSPENSION WIRES SHALL NOT HANG MORE THAN ONE IN SIX (1:6) OUT OF PLUMB UNLESS COUNTER SLOPING WIRES ARE PROVIDED. 5. WIRES SHALL NOT ATTACH TO, OR BEND AROUND, INTERFERING MATERIAL, SUCH AS DUCTS. A TRAPESE OR EQUIVALENT DEVICE SHALL BE USED WHERE OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION. 6. AT ALL LOCATIONS, THE TERMINAL ENDS OF EACH CROSS RUNNER SHALL BE SUPPORTED INDEPENDENTLY, A MAXIMUM OF 8 INCHES FROM EACH WALL WITH No. 12 GAGE (2.05 mm) WIRE. 7. HORIZONTAL RESTRAINT SHALL BE EFFECTED BY FOUR No. 12 GAGE WIRES SECURED TO THE MAIN RUNNER WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER, AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12 FEET ON CENTER IN BOTH DIRECTIONS, WITH THE FIRST POINT WITHIN 4 FEET OF EACH WALL. ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE ABOVE SHALL BE ADEQUATE FOR THE LOAD IMPOSED. (ALTERNATIVE METHODS FOR PROVIDING HORIZONTAL RESTRAINT WILL BE CONSIDERED ACCEPTABLE SO LONG AS THEIR PERFORMANCE IS PROVEN TO BE EQUAL TO OR BETTER THAN THE PRESCRIBED METHOD) C. LIGHT FIXTURE APPLICATION 1. ALL RECESSED LIGHTING FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM BY MECHANICAL MEANS AS SPECIFIED IN THE NATIONAL ELECTRICAL CODE, UNLESS INDEPENDENTLY SUPPORTED. THE ATTACHMENT DEVICE, A MINIMUM OF TWO (2) PER FIXTURE, SHALL HAVE A CAPACITY OF 100% OF THE LIGHTING FIXTURE WEIGHT ACTING IN ANY DIRECTION. 2. SURFACE MOUNTED LIGHTING FIXTURES SHALL BE ATTACHED TO THE CEILING SYSTEM WITH POSITIVE CLAMPING DEVICES THAT COMPLETELY SURROUND THE SUPPORTING MEMBERS. SAFETY WIRES SHALL BE ATTACHED BETWEEN THE CLAMPING DEVICE AND THE ADJACENT CEILING HANGER OR TO THE STRUCTURE ABOVE. IN NO CASE SHALL THE APPLIED FIXTURE LOAD EXCEED THE DESIGN CARRYING CAPACITY OF THE SUPPORTING MEMBER. 3. PENDANT HUNG LIGHTING FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE USING No. 9 GAGE (2.91 mm) WIRE WITHOUT USING THE CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT. 4. RIGID CONDUIT IS NOT RECOMMENDED FOR ATTACHMENT OF FIXTURES. 5. LIGHTING FIXTURES WEIGHING LESS THAN 56 lb. SHALL HAVE, IN ADDITION TO THE REQUIREMENTS OUTLINED ABOVE, TWO (2) No. 12 GAGE HANGERS CONNECTED FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. 6. LIGHTING FIXTURES WEIGHING 56 lb. OR MORE SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. D. SERVICES WITHIN THE CEILING: 1. THE SUSPENDED CEILING SHALL NOT BE USED TO SUPPORT DUCTWORK, PLUMBING, ETC. THESE ITEMS SHOULD BE ATTACHED TO THE STRUCTURE ABOVE EXCEPT WHEN SUCH UNITS WERE SPECIALLY DESIGNED FOR THIS APPLICATION, AS IN THE CASE OF INTEGRATED CEILING SYSTEMS. 2. CEILING MOUNTED AIR TERMINALS, OR SERVICES WEIGHING LESS THAN 20 lb. SHALL BE POSITIVELY ATTACHED TO THE SUSPENSION SYSTEM UNLESS DEFLECTION MINIMUMS ARE EXCEEDED. E. PARTITION APPLICATION TO SUSPENDED CEILINGS: 1. WHERE NON-BEARING PARTITIONS ARE ATTACHED TO CEILING SUSPENSION SYSTEMS, THE LATERAL FORCE REACTION TRANSMITTED MUST FALL WITHIN THE DESIGN LIMITATION OF THE SUSPENSION SYSTEM OR SUPPLEMENTARY BRACING MUST BE PROVIDED. GENERAL CEILING NOTES: REFER TO LIGHTING PLAN FOR FIXTURE TYPES AND SWITCHING LOCATIONS ACT: INSTALL, WHERE NOTED, ARMSTRONG CEILING 24" x 24" GRID CANYON WITH TEGULAR EDGE WITH PRELUDE ML EXPOSED TEE SUSPENSION SYSTEM AM10/23/20