HomeMy WebLinkAboutState_Release_Drawings_9152020MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO.
JOB NO.
SCOPE DOCUMENT
THE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE
MAJOR ARCHITECTURAL ELEMENTS AND
THE TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL
SYSTEMS. AS SCOPE DOCUMENTS, THE
DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK THAT
IS REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT
DOCUMENTS. ON THE BASIS OF THE
GENERAL SCOPE INDICATED OR
DESCRIBED, THE TRADE CONTRACTORS
SHALL FURNISH ALL ITEMS REQUIRED
FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY
ONLY TO THE DOCUMENT TO WHICH
THEY ARE AFFIXED AND WE EXPRESSLY
DISCLAIM ANY RESPONSIBILITY FOR ALL
OTHER PLANS, SPECIFICATIONS,
ESTIMATES, REPORTS, OR OTHER
DOCUMENTS OR INSTRUMENTS
RELATING TO OR INTENDED TO BE USED
FOR ANY PART OR PARTS OF THE
PROJECT.
COPYRIGHT 2020 HOLDER DESIGN, INC.
REVISIONS
A20-020 SHEET DESCRIPTION: -24 South 5th Street
Terre Haute, Indiana
47807
ph. 812.235.1300
www.holderdesign.net
HOLDERDESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:COVER SHEETDRAWING INDEX:
ARCHITECTURAL
COVER SHEET
CONTACT INFO
ARCHITECT:
HOLDER DESIGN, INC
24 South 5th Street
Terre Haute, IN 47807
PHONE:
E-MAIL:
CONTACT:
812.235.1300
mholder@holderdesign.net
Matthew L. Holder AIA
DRAWING NAME# REV. 1
A0.0
REV. 2
120 EAST CARMEL DRIVE, CAMEL, INDIANA 46032
LOCATOR MAP
NORTH
PROJECT LOCATION
HAMILITON COUNTY,
INDIANA
VICINITY MAP PROJECT INFO.
GENERAL NOTES:
PROPOSED INSTRUCTIONS FOR:
PROJECT ADDRESS 120 CARMEL DRIVE
CARMEL, INDIANA 46032
PROJECT DESCRIPTION TENANT EXPANSION INTO AN
EXISTING UNFINISHED SPACE
PLANNED SQUARE FOOTAGE NEW FIT-OUT: 1,172 SF
CONSTRUCTION TYPE V-B
OCCUPANCY B-BUSINESS
A0.0
GENERAL ADMINISTRATIVE RULES: (675-IAC-12)
INDIANA BUILDING CODE, 2014 EDITION: (675-IAC-13-2.6 IBC) BASED
ON; 2012 INTERNATIONAL BUILDING CODE (1ST PRINTING), ANSI
A117.1-2009, WITH INDIANA AMENDMENT, EFFECTIVE DECEMBER 1,
2014
INDIANA RESIDENTIAL CODE 2005 EDITION: (675-IAC-14-4.3 ) BASED
ON: 2003 INTERNATIONAL RESIDENTIAL CODE, WITH INDIANA
AMENDMENTS, EFFECTIVE APRIL 15, 2012
INDUSTRIALIZED BUILDING SYSTEMS: (675-IAC-15-1.1 THROUGH
15-1.7) EFFECTIVE SEPTEMBER 17, 2005
INDIANA PLUMBING CODE 2012 EDITION: (675-IAC-16-1.4P ) BASED
ON: 2006 INTERNATIONAL PLUMBING CODE WITH INDIANA
AMENDMENTS, EFFECTIVE DECEMBER 24, 2012
INDIANA ELECTRICAL CODE 2009 EDITION: (675-IAC-17-1.8 IEC)
BASED ON: 2008 NATIONAL ELECTRICAL CODE (1ST PRINTING) WITH
INDIANA AMENDMENTS, EFFECTIVE AUGUST 26, 2009
INDIANA MECHANICAL CODE 2014 EDITION: (675-IAC-18-1.6 IMC)
BASED ON: 2012 INTERNATIONAL MECHANICAL CODE (1ST PRINTING)
WITH INDIANA AMENDMENTS, EFFECTIVE DECEMBER 1, 2014
INDIANA ENERGY CONSERVATION CODE 2010, (675 IAC 19-4),
(ASHRAE 90.1 2007 EDITION, AS AMENDED)
INDIANA SAFETY CODE FOR ELEVATORS, ESCALATORS, MAN LIFTS
AND HOISTS; (675-IAC-21-11-2 SCEEMH) BASED ON: AUTOMATED
PEOPLE MOVER-PART 1, PART 2, AND PART 3, ANSI/ASCE/T &DI
21-08, AS AMENDED EFFECTIVE APRIL 13, 2011
INDIANA FIRE PREVENTION CODE: (675-IAC-22-2.5 IFC) BASED ON: 2012
INTERNATIONAL FIRE CODE, (1ST PRINTING) WITH INDIANA
AMENDMENTS, EFFECTIVE DECEMBER 1, 2014.
INDIANA SUPPLEMENTARY FIRE SAFETY RULES: (675-IAC-24-1 SFSR)
EFFECTIVE OCTOBER 11, 2001
INDIANA FUEL GAS CODE 2014: (675-IAC-25-3 IFGC) BASED ON: 2012
INTERNATIONAL FUEL GAS CODE (2ND PRINTING), WITH INDIANA
AMENDMENTS, EFFECTIVE DECEMBER 1, 2014
1. G.C. (GENERAL CONTRACTOR) SHALL REVIEW ALL DOCUMENTS AND FIELD VERIFY ALL
DIMENSION AND CONDITIONS AND SHALL CONFIRM THAT WORK IS BUILDABLE AS SHOWN.
ANY DISCREPANCIES OR OMISSIONS, ETC... SHALL BE REPORTED TO THE ARCHITECT
IMMEDIATELY FOR CLARIFICATION PRIOR TO BEGINNING WORK RELATED THERETO.
2. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CURRENT RULES AND
REGULATIONS OF APPLICABLE STATE AND/OR LOCAL CODES , LAWS, ORDINANCES,
STATUTES AND REGULATIONS. NOTHING IN THE DRAWINGS OR SPECIFICATIONS SHALL BE
CONSTRUED AS REQUIRING OR PERMITTING WORK CONTRARY TO THESE RULES,
REGULATIONS AND CODES. REPORT ANY DISCREPANCIES BETWEEN DRAWINGS AND
SPECIFICATIONS AND APPLICABLE REGULATIONS TO ARCHITECT IMMEDIATELY.
3. THE DRAWINGS INDICATE LOCATIONS, DIMENSIONS, AND TYPICAL DETAILS OF
CONSTRUCTION. THE DRAWINGS DO NOT ILLUSTRATE EVERY CONDITION. WORK NOT
EXPLICITLY DETAILED IS ASSUMED TO BE OF CONSTRUCTION SIMILAR TO PARTS THAT ARE
DETAILED. G.C. SHALL REPORT ANY DISCREPANCIES DISCOVERED TO THE ARCHITECT FOR
RESOLUTION BEFORE PROCEEDING WITH WORK.
4. ALL DIMENSIONS SHOWN IN DRAWING ARE BASED ON SPECIFIED MATERIALS AND
EQUIPMENT. ANY CHANGES OR SUBSTITUTIONS MAY AFFECT DIMENSIONS. G.C. TO NOTIFY
ARCHITECT BEFORE MAKING CHANGES.
5. G.C. TO COORDINATE ALL WORK WITH MECHANICAL, ELECTRICAL, PLUMBING AND
FIRE-PROTECTION CONTRACTORS. G.C. SHALL SUBMIT ALL DRAWINGS TO THE ARCHITECT
FOR REVIEW PRIOR TO CONSTRUCTION.
6. THE G.C SHALL COORDINATE AND COOPERATE WITH THE WORK OF SEPARATE
CONTRACTORS.
7. G.C. SHALL PROVIDE ALL SHOP DRAWINGS FOR FABRICATED ITEMS, CATALOG CUTS FOR
ALL FIXTURES AND EQUIPMENT, AND SAMPLES OF AL FINISHES SPECIFIED TO THE
ARCHITECT FOR APPROVAL THREE (3) WEEKS PRIOR TO FABRICATION AND/OR
PURCHASING.
8. ALL FIRE RESISTIVE ASSEMBLIES SHALL BE MAINTAINED AT ALL MECHANICAL, ELECTRICAL,
AND PLUMBING WALL PENETRATIONS THROUGH THE USE OF FIRE STOP MATERIAL AT
THESE LOCATIONS USING THE APPROPRIATE FIRE RATED ASSEMBLIES.
LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON
THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE
(INCLUDING, BUT NOT LIMITED TO, MANHOLES, INLETS, VALVES,
AND MARKS MADE UPON THE GROUND BY OTHERS) AND ARE
SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISTING
UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE
GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE
WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISITNG
UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE
CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION.
CALL 811 OR 1-800-382-5544
48 HOURS BEFORE DIGGING
NORTH
OWNER:
PREMIER FAMILY CHIROPRACTIC
120 E Carmel Drive
Carmel, Indiana 46032
PHONE: 317.250.7210
E-MAIL: drmike@premierfamilychiro.com
CONTACT: Dr. Mike Wasserstrom
EXISTING CONDITIONSA1.0
BUILDING CODES:
REV. 3
MEP
HVAC PLANM1.0
POWER, DATA, + SWITCHING PLANE1.0
WALL SECTIONSA3.0
LIFE SAFETY PLANA4.0
PROPOSED FLOOR PLANA1.1
REFLECTED CEILING PLANA2.0
E CARMEL DRIVES RANGELINE ROADEXECUTIVE DRIVEAM10/23/20
EXISTING FIRE WALL
SUPPORT COLUMN
WOOD ROOF TRUSSES
24" O.C. (TYP)
SUPPORT BEAM
ELECTRICAL PANEL
REMOVE BLOCK WALL
UNIT 120
NOT IN CONSTRUCTION
2,487 SF
NON-SPRINKLERED
UNFINISHED AREA
2,387 SF
NON-SPRINKLERED
UTILITIES
OFFICE
OFFICE
UNIT 116 UNIT 118
+11'-11 3/8"
RAFTERS60'-9 1/2"39'-5 1/2"
ELECTRICAL PANEL
OFFICE
OFFICE
STORAGE
LOBBY
OPEN OFFICE
MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO.
JOB NO.
SCOPE DOCUMENT
THE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE
MAJOR ARCHITECTURAL ELEMENTS AND
THE TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL
SYSTEMS. AS SCOPE DOCUMENTS, THE
DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK THAT
IS REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT
DOCUMENTS. ON THE BASIS OF THE
GENERAL SCOPE INDICATED OR
DESCRIBED, THE TRADE CONTRACTORS
SHALL FURNISH ALL ITEMS REQUIRED
FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY
ONLY TO THE DOCUMENT TO WHICH
THEY ARE AFFIXED AND WE EXPRESSLY
DISCLAIM ANY RESPONSIBILITY FOR ALL
OTHER PLANS, SPECIFICATIONS,
ESTIMATES, REPORTS, OR OTHER
DOCUMENTS OR INSTRUMENTS
RELATING TO OR INTENDED TO BE USED
FOR ANY PART OR PARTS OF THE
PROJECT.
COPYRIGHT 2020 HOLDER DESIGN, INC.
REVISIONS
A20-020 SHEET DESCRIPTION: -24 South 5th Street
Terre Haute, Indiana
47807
ph. 812.235.1300
www.holderdesign.net
HOLDERDESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:EXISTING CONDITIONSAMA1.0
KEYED PLAN NOTES:
DEMO PORTION OF EXISTING BLOCK WALL COMPLETE
DEMO EXISTING STUD WALL COMPLETE
REMOVE AND SALVAGE EXISTING INTERIOR POCKET DOOR
1
KEY:
DEMO
EXISTING PARTITIONS TO REMAIN
NEW STUD PARTITIONS
2
3
3
1
2
2
2
GENERAL DEMOLITION NOTES
REMOVE ALL EXISTING CONSTRUCTIONS AND FINISHES NECESSARY FOR THE COMPLETION OF THE WORK AS
DEPICTED ON THE DRAWINGS. INCLUDING BUT NOT LIMITED TO ITEMS SHOWN ON THE PLANS WITH DASHED
LINES. NECESSARY DISCONNECTS AND ALTERATIONS TO EXISTING MECHANICAL AND ELECTRICAL SYSTEMS
SHALL BE INCLUDED. PATCH AS REQUIRED ALL CONSTRICTIONS TO REMAIN IN ACCORDANCE WITH THE
CONTRACT DRAWINGS.WHERE CONTRACTOR IS DESIGNATED TO MAKE REMOVALS, DISPOSITION OF MATERIALS
IS THE RESPONSIBILITY OF THE CONTRACTOR. VERIFY WITH THE OWNER, THE DISPOSITION AND REMOVAL OF
ANY COMPONENTS OF SALVAGEABLE VALUE.
ALL REMOVALS AND SALVAGE, UNLESS SPECIFICALLY NOTED OR REQUESTED BY THE OWNER SHALL BECOME
THE PROPERTY OF THE CONTRACTOR.
REMOVE ONLY NON-LOAD BEARING CONSTRUCTION AND PARTITIONS. CONTRACTOR TO VERIFY, PRIOR TO
REMOVAL THAT NO STRUCTURAL COMPONENTS, I.E. BEARING WALLS, BEAMS, HEADERS, ETC.. SUPPORTING
FLOOR, ROOF, OR CEILING JOISTS ARE DESIGNATED FOR REMOVAL. CONTACT THE ARCHITECT PRIOR TO
REMOVAL OF ANY CONSTRUCTION IN QUESTION OR DEVIATING FROM THE DESIGN INTENT. CONTRACTORS
NON-CONTACT OF ARCHITECT PRIOR TO REMOVAL OF ANY WORK INDICATES HIS COMPLETE UNDERSTANDING
THAT NO LOAD BEARING OR STRUCTURAL WORK IS BEING ALTERED UNDER THIS CONTRACT.
PATCH ALL FINISHES TO MATCH EXISTING, INCLUDING BUT NOT LIMITED TO, GYPSUM BOARD, PLASTER,
ACOUSTIC SYSTEMS, WOODTRIM, COVERS, BASE, PANELS, RAILS, AND WAINSCOT. VERIFY MATCH OF NEW FINISH
MATERIALS TO EXISTING IN COLOR, TEXTURE, THICKNESS, CUT, ETC.. TO SATISFACTION OF OWNER PRIOR TO
INSTALLATIONS. PROVIDE OTHER MATERIALS TO MATCH EXISTING WHEN REQUIRED. TO BE APPROVED BY
OWNER.
PATCH EXISTING WALLS GYPSUM DRYWALL OR PLASTER TO MATCH EXISTING OF SUFFICIENT THICKNESS TO
MAINTAIN UNIFORM WALL THICKNESS. ALL EXPOSED PORTIONS OF WALL SHALL BE FINISHED WITH THREE (3)
COATS OF SPECKLING, SANDED AND LEFT IN A PAINT READY CONDITION.
WHERE APPLICABLE LEVEL ALL EXISTING FLOORS AS REQUIRED TO RECEIVE NEW FLOOR FINISHES. INSTALL
REQUIRED TRANSITION PIECES BETWEEN VARIOUS FLOOR FINISHED SUITABLE FOR CONDITIONS AND
ACCEPTABLE TO THE OWNER. MATCH EXISTING WHEREVER POSSIBLE.
CONTRACTOR SHALL INSURE ALL WORK IS IN CONFORMANCE WITH ALL APPLICABLE BUILDING CODES. WORK
SHALL BE COMPLETED IN STRICT ACCORDANCE WITH THE LATEST EDITIONS BUILDING CODE AND ENERGY
CONSERVATION CODE, PLUMBING CODE, NATIONAL ELECTRICAL CODE, AND ALL OTHER FEDERAL, STATE AND
LOCAL AGENCY REGULATIONS HAVING JURISDICTION OVER THIS PROJECT. IN THE EVENT OF ANY
DISCREPANCIES BETWEEN AGENCY REQUIREMENT. THE CONTRACTOR SHALL OBSERVE THE MORE STRINGENT
OF REQUIREMENTS.
ALL WORK SHALL COMPLY WITH THE STANDARDS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS (NBFU0,
INDUSTRIAL RISK INSURANCE UNERWRITERS (IRI), FACTORY MUTUAL (FW), OR THE APPLICABLE RATING BUREAU.
THE NATIONAL ELECTRIC CODE (NEC), THE AMERICAN GAS ASSOCIATION (AGA), AND THE AMERICAN SOCIETY OF
HEATING AND AIR CONDITIONING ENGINEERS (ASHAE), OCCUAPTIONAL SAFETY AND HEALTH ADMINISTRATION
(OSHA), APPLICABLE STATE AND CITY BUILDING CODES AND THE REQUIREMENTS OF ALL PUBLIC UTILITY
COMPANIES SERVING THE PROJECT SITE.
CONTRACTOR (AND HIS SUBCONTRACTORS) SHALL BE LICENSED BY THE STATE IN WHICH THE PROJECT IS
LOCATED AND APPROVED IN ADVANCE BY THE OWNER.
ALL WORK IS TO BE COORDINATED WITH THE OWNER. THE CONTRACTOR IS TO MEET WITH THE OWNER PRIOR TO
STARTING CONSTRUCTION.
CHECK WITH THE OWNER FOR COORDINATION OF THE WORK UNDER THIS CONTRACT WITH WORK OF OTHER
TRADES. OWNER'S REGULATIONS GOVERN ALL ASPECTS OF OUTSIDE CONTRACTORS WORKING ON THE
PROPERTY.
CONTRACTOR SHALL KEEP THE JOB FREE OF DEBRIS AND MAKE FINAL CLEANUP TO THE SATISFACTION OF THE
OWNER. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ALL CONSTRUCTION DEBRIS FROM PROJECT
SITE AND SHALL PROVIDE DUMPSTER'S ETC. AS REQUIRED. REMOVE ALL DEBRIS ON A DAILY BASIS.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING BUILDINGS AND OTHER
INSTALLATIONS THAT ARE TO REMAIN INTACT WHILE PERFORMING THE SPECIFIED WORK. PROVIDE AND
MAINTAIN FIRE EXTINGUISHERS ON PROJECT SITE DURING CONSTRUCTION.
UNLESS INDICATED OTHERWISE, ALL MATERIAL FURNISHED AND INCORPORATED INTO THE WORK SHALL BE NEW,
UNUSED, AND OF QUALITY STANDARD TO THE INDUSTRY FOR FIRST CLASS WORK OF SIMILAR NATURE AND
CHARACTER. INSTALL ALL MATERIALS TO THE MANUFACTURER'S RECOMMENDATIONS AND BEST STANDARD OF
THE TRADES INVOLVED.
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS IN FIELD PRIOR CONSTRUCTION. NOTIFY ARCHITECT IS ANY
DISCREPANCIES ON DRAWINGS.
PROVIDE SLEEVE THROUGH FOUNDATION FOR PENETRATIONS AS REQUIRED. COORDINATE W/ CIVIL
ENGINEERING DOCUMENTS.
CONTRACTOR SHALL PROVIDE ANY NECESSARY MEASURE TO PROTECT THE WORKERS AND OTHER PERSONS
DURING CONSTRUCTION.
CONTRACTOR & MEP CONTRACTOR SHALL VERIFY LOCATION OF ROOF MOUNTED EQUIPMENT.
INTERIOR FINISHES SHALL BE CLASS C (SURFACE FLAME SPREAD RATING OF 76-200)MINIMUM IN CONFORMITY
WITH GENERALLY ACCEPTED STANDARDS. CARPETING SHALL BE CLASS 2 WITH A MINIMUM CRITICAL RADIANT
FLUX OF 22-WATTS PER SQUARE CENTIMETER.
ALL GYPSUM BOARD WORK SHALL BE DONE IN ACCORDANCE WITH THE DRYWALL CONSTRUCTION HANDBOOK,
LATEST EDITION. PREPARED BY UNITED STATES GYPSUM. ALL JOINTS AND SEAMS SHALL BE TAPED AND
FINISHED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION RECOMMENDATIONS.
VISIT THE SITE TO VERIFY EXISTING CONDITIONS. EXISTING CONCEALED CONDITIONS AND CONNECTIONS ARE
BASED UPON INFORMATION TAKEN FROM LIMITED FIELD INVESTIGATIONS. CONTRACTOR SHALL MAKE REQUIRED
ADJUSTMENTS TO SYSTEM COMPONENTS AS NECESSITATED BY ACTUAL FIELD CONDITIONS AT NO ADDITIONAL
COST TO OWNER OR ARCHITECT. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD
CONDITIONS TO THE ARCHITECT BEFORE CONSTRUCTION.
A1.0 SCALE: 1/4" = 1'-0"
1 EXISTING CONDITIONS
N
10/23/20
EXISTING FIRE WALL
ELECTRICAL PANEL
UNIT 116
NOT IN SCOPE
1,215 SF
NON-SPRINKLERED
UTILITIES
108
UNIT 118
1,172 SF
NON-SPRINKLERED
+11'-11 3/8"
RAFTERS60'-9 1/2"39'-5 1/2"
ELECTRICAL PANEL
LOBBY
100
RECEPTION
101
OFFICE
102
HALL
103
OFFICE
104
HALL
105
CONFERENCE
106
STORAGE
107
OFFICE
OFFICE
STORAGE
UNIT 120
NOT IN SCOPE
2,487 SF
NON-SPRINKLERED
LOBBY
OPEN OFFICE
100
10
7
10
8
106104102
7'-10 1/2"7'-10 1/2"
3'-7"12'-4 1/8" 3'-7"
19'-6 1/8"
7'-1"3'-1 3/8"6'-3 1/8" 7'-10" 10'-3"3'-9 1/8" 3'-9" 20'-10 1/2" 8'-8 3/4"P2
P2
P2
P3 P31
A3.0
2
A3.0
2
A3.0
TYP.
2"x4" WOOD STUDS @ 16" O.C. WITH SOUND BATT AND
5/8" GYPSUM WALLBOARD EACH SIDE. EXTEND STUDS AND
GYPSUM WALLBOARD TO UNDERSIDE OF ROOF JOISTS,
UNLESS OTHERWISE NOTED. USE WATER RESISTANT
GYPSUM WALL BOARD AT ALL WET WALL LOCATIONS.
*ALL WALLS P1 UNLESS OTHERWISE NOTED
TYPICAL PARTITIONP1
1- HR FIRE RATED PARTITIONP2
6 3/4"2"x4" WOOD STUDS @ 16" O.C. WITH 5/8" GYPSUM
WALLBOARD EACH SIDE. EXTEND STUDS AND GYPSUM
WALLBOARD TO 3'-0" AFF, UNLESS OTHERWISE NOTED.
USE WATER RESISTANT GYPSUM WALL BOARD AT ALL
WET WALL LOCATIONS.
KNEE WALLP3 4 3/4" 4 3/4"2"x6" WOOD STUDS @ 16" O.C. WITH SOUND BATT AND
5/8" TYPE 'X' GYPSUM WALLBOARD EACH SIDE. EXTEND
STUDS AND GYPSUM WALLBOARD TO UNDERSIDE OF ROOF
JOISTS. USE WATER RESISTANT GYPSUM WALL BOARD AT
ALL WET WALL LOCATIONS.DOORNUMBERWIDTHHEIGHTFAMILY AND TYPE ELEVATIONMATERIALNOTES
SIZE
DOOR FRAME
DOOR & FRAME SCHEDULE
102 ELEVATION3'-0" 1 3/4"
1 3/4" 104 3'-0"THICKDOOR TYPES:
1. DOOR: HINGED SLAB. FRAME: WOOD, PAINTED, OWNER TO SELECT FROM FULL RANGE OF COLORS
2. DOOR: SOLID CORE WOOD POCKET W/ FULL-LITE FROSTED GLASS PANEL. FRAME: WOOD, PAINTED
106 1 3/4"
107
108
3'-0" GLASS100 Existing to RemainDOOR TYPEF1
F1
HARDWARE SCHEDULE
2
HARDWARE SET #1:
PRIVACY SET: SCHLAGE
SATURN AL80PD
CYLINDRICAL
STOREROOM LOCK
FINISH: 626 SATIN
HINGES: STANLEY / BEST
4 1/2" x 4 1/2"
FULL MORTISE
CB179 HARDWAREHARDWARE SET #2:
PRIVACY SET: SCHLAGE
SATURN AL70PD
OFFICE LOCK
FINISH: 626 SATIN
HINGES: STANLEY / BEST
4 1/2" x 4 1/2"
FULL MORTISE
CB179
1
2 6'-8" SCW Pocket/ Single-Flush
D1
D2
WD
WD#2
#1
Existing to Remain
Existing to Remain
Hinged Slab/ Single-Flush
F1SCW Pocket/ Single-Flush D2 WD#2 6'-8"
6'-8" 6'-8"3'-0"6'-8"3'-0"
DOOR 1 (D1) DOOR 2 (D2)
3'-4"6'-8" FRAME 1 (F1)
2"2" MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO.
JOB NO.
SCOPE DOCUMENT
THE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE
MAJOR ARCHITECTURAL ELEMENTS AND
THE TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL
SYSTEMS. AS SCOPE DOCUMENTS, THE
DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK THAT
IS REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT
DOCUMENTS. ON THE BASIS OF THE
GENERAL SCOPE INDICATED OR
DESCRIBED, THE TRADE CONTRACTORS
SHALL FURNISH ALL ITEMS REQUIRED
FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY
ONLY TO THE DOCUMENT TO WHICH
THEY ARE AFFIXED AND WE EXPRESSLY
DISCLAIM ANY RESPONSIBILITY FOR ALL
OTHER PLANS, SPECIFICATIONS,
ESTIMATES, REPORTS, OR OTHER
DOCUMENTS OR INSTRUMENTS
RELATING TO OR INTENDED TO BE USED
FOR ANY PART OR PARTS OF THE
PROJECT.
COPYRIGHT 2020 HOLDER DESIGN, INC.
REVISIONS
A20-020 SHEET DESCRIPTION: -24 South 5th Street
Terre Haute, Indiana
47807
ph. 812.235.1300
www.holderdesign.net
HOLDERDESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:PROPOSED FLOOR PLANAMA1.1
KEY:
DEMO
EXISTING PARTITIONS TO REMAIN
NEW STUD PARTITIONS
GENERAL NOTES:
PARTITION TYPES:
PARTITIONS ARE DIMENSIONED FROM FACE OF STUD OR MASONRY, UNLESS NOTED OTHERWISE. REFER TO WALL
TYPES FOR PARTITION THICKNESS.
PROVIDE WOOD BLOCKING SUPPORT AT ALL SURFACE MOUNTED ITEMS MOUNTED TO FACE OF DRYWALL.
PROVIDE MISCELLANEOUS METAL SUPPORTS FOR ALL CEILING SUPPORTED ITEMS.
ALL PLUMBING FIXTURES TO BE LOCATED IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL CODES.
CAULK ALL TOILET FIXTURES TO WALL USING CLEAR SILICONE SEALANT.
PROVIDE WATER RESISTIVE DRYWALL IN ALL WET LOCATIONS.
PROVIDE MISCELLANEOUS METAL SUPPORTS FOR ALL CEILING SUPPORTED ITEMS.
PROVIDE AND INSTALL FIRE EXTINGUISHERS AND OR CABINETS, OWNER APPROVED, AS REQUIRED BY ALL
APPLICABLE CODES
FEC CABINETS TO BE MOUNTED SO THE EXTINGUISHER HANDLE TO BE AT 48" A.F.F.
PROVIDE AND INSTALL PANIC HARDWARE AND ALL RELATED COMPONENTS AT ALL LOCATIONS REQUIRED BY
LOCAL, STATE AND FEDERAL CODES.
FIELD VERIFY ALL DIMENSIONS. FIELD VERIFY AND COORDINATE WITH ALL EXISTING CONDITIONS.
A1.1 SCALE: 1/4" = 1'-0"
1 PROPOSED FLOOR PLAN
N
10/23/20
EXISTING FIRE WALL
ELECTRICAL PANEL
UNIT 116
NOT IN SCOPE
1,215 SF
NON-SPRINKLERED
UTILITIES
108
UNIT 118
1,172 SF
NON-SPRINKLERED
+11'-11 3/8"
RAFTERS
ELECTRICAL PANEL
LOBBY
100
RECEPTION
101
OFFICE
102
HALL
103
OFFICE
104
HALL
105
CONFERENCE
106
STORAGE
107
R RR
R
RR R
R
R
R
R
R
R RR
R
R
R
R
R
R
R
R
R R R
R
R
R
R
OFFICE
OFFICE
STORAGE
UNIT 120
NOT IN SCOPE
2,487 SF
NON-SPRINKLERED
LOBBY
OPEN OFFICE
+9'-4"
ACT
+9'-4"
ACT
+9'-4"
ACT
+9'-4"
ACT
+9'-4"
ACT
+9'-4"
ACT
MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO.
JOB NO.
SCOPE DOCUMENT
THE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE
MAJOR ARCHITECTURAL ELEMENTS AND
THE TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL
SYSTEMS. AS SCOPE DOCUMENTS, THE
DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK THAT
IS REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT
DOCUMENTS. ON THE BASIS OF THE
GENERAL SCOPE INDICATED OR
DESCRIBED, THE TRADE CONTRACTORS
SHALL FURNISH ALL ITEMS REQUIRED
FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY
ONLY TO THE DOCUMENT TO WHICH
THEY ARE AFFIXED AND WE EXPRESSLY
DISCLAIM ANY RESPONSIBILITY FOR ALL
OTHER PLANS, SPECIFICATIONS,
ESTIMATES, REPORTS, OR OTHER
DOCUMENTS OR INSTRUMENTS
RELATING TO OR INTENDED TO BE USED
FOR ANY PART OR PARTS OF THE
PROJECT.
COPYRIGHT 2020 HOLDER DESIGN, INC.
REVISIONS
A20-020 SHEET DESCRIPTION: -24 South 5th Street
Terre Haute, Indiana
47807
ph. 812.235.1300
www.holderdesign.net
HOLDERDESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:REFLECTED CEILING PLANA2.0
A2.0 SCALE: 1/4" = 1'-0"
1 REFLECTED CEILING PLAN
N
45
ATTACHED AT
STARTING AND
ONE ADJACENT
RUNNERS AT WALLS
WALL
TYPICAL CEILING BRACING
CLEARANCE AT
OPPOSITE WALLS
(NOT ATTACHED)
2" MAX
MAIN RUNNER
8" MAX
No.12 GAGE SPLY WIRES
VERTICAL ANGLE = 45
8" MAX
3/8" MIN.
2" MAX
45
45
45
3/8" MIN.
2" MAX
SUSPENDED CEILING SYSTEM NOTES:
A. SUSPENSION SYSTEM COMPONENTS:
1. ONLY INTERMEDIATE AND HEAVY-DUTY SYSTEMS MAY BE USED.
2. MAIN RUNNERS AND CROSS RUNNERS OF THE CEILING GRID SYSTEMS AND THEIR
SPLICES AND INTERSECTION CONNECTIONS SHALL SUPPORT NOT LESS THAN 60 lbs.
DESIGN LOAD IN TENSION AND COMPRESSION. ACCEPTABLE TEST RESULTS SHALL
SHOW ULTIMATE LOADS AVERAGING NO LESS THAN 120 lbs.
B. SUSPENSION SYSTEM APPLICATION:
1. MAIN RUNNERS AND CROSS RUNNERS SHALL BE ATTACHED TO THE PERIMETER MEMBERS
ON TWO (2) ADJACENT WALLS. A CLEARANCE OF 1/4" SHALL BE MAINTAINED BETWEEN THE
MAIN RUNNERS AND CROSS RUNNERS AND THE PERIMETER MEMBERS ON THE TWO
REMAINING WALLS.
2. SUSPENSION WIRES SHALL BE SPACED ALONG EACH MAIN RUNNER IN ACCORDANCE WITH
THE LOAD CARRYING CAPACITY OF THE SYSTEM AND SHALL BE A MINIMUM OF No. 12 GAGE
(2.05 mm) SOFT ANNEALED GALVANIZED STEEL WIRE.
3. EACH VERTICAL WIRE SHALL BE ATTACHED TO THE CEILING SUSPENSION MEMBER WITH A
MINIMUM OF THREE (3) TURNS AND TO THE STRUCTURE ABOVE WITH A CONNECTION
CAPABLE OF CARRYING NOT LESS THAN A 100 lb. ALLOWABLE LOAD. THE POINTS OF
HANGER WIRE SUPPORTS SHALL NOT PERMIT DISENGAGEMENT THROUGH VERTICAL
LIFTING.
4. SUSPENSION WIRES SHALL NOT HANG MORE THAN ONE IN SIX (1:6) OUT OF PLUMB UNLESS
COUNTER SLOPING WIRES ARE PROVIDED.
5. WIRES SHALL NOT ATTACH TO, OR BEND AROUND, INTERFERING MATERIAL, SUCH AS
DUCTS. A TRAPESE OR EQUIVALENT DEVICE SHALL BE USED WHERE OBSTRUCTIONS
PRECLUDE DIRECT SUSPENSION.
6. AT ALL LOCATIONS, THE TERMINAL ENDS OF EACH CROSS RUNNER SHALL BE SUPPORTED
INDEPENDENTLY, A MAXIMUM OF 8 INCHES FROM EACH WALL WITH No. 12 GAGE (2.05 mm)
WIRE.
7. HORIZONTAL RESTRAINT SHALL BE EFFECTED BY FOUR No. 12 GAGE WIRES SECURED TO
THE MAIN RUNNER WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED
90 DEGREES FROM EACH OTHER, AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE
PLANE OF THE CEILING. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12
FEET ON CENTER IN BOTH DIRECTIONS, WITH THE FIRST POINT WITHIN 4 FEET OF EACH
WALL. ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE ABOVE SHALL BE
ADEQUATE FOR THE LOAD IMPOSED. (ALTERNATIVE METHODS FOR PROVIDING
HORIZONTAL RESTRAINT WILL BE CONSIDERED ACCEPTABLE SO LONG AS THEIR
PERFORMANCE IS PROVEN TO BE EQUAL TO OR BETTER THAN THE PRESCRIBED METHOD)
C. LIGHT FIXTURE APPLICATION
1. ALL RECESSED LIGHTING FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED
CEILING SYSTEM BY MECHANICAL MEANS AS SPECIFIED IN THE NATIONAL ELECTRICAL
CODE, UNLESS INDEPENDENTLY SUPPORTED. THE ATTACHMENT DEVICE, A MINIMUM OF
TWO (2) PER FIXTURE, SHALL HAVE A CAPACITY OF 100% OF THE LIGHTING FIXTURE
WEIGHT ACTING IN ANY DIRECTION.
2. SURFACE MOUNTED LIGHTING FIXTURES SHALL BE ATTACHED TO THE CEILING SYSTEM
WITH POSITIVE CLAMPING DEVICES THAT COMPLETELY SURROUND THE SUPPORTING
MEMBERS. SAFETY WIRES SHALL BE ATTACHED BETWEEN THE CLAMPING DEVICE AND THE
ADJACENT CEILING HANGER OR TO THE STRUCTURE ABOVE. IN NO CASE SHALL THE
APPLIED FIXTURE LOAD EXCEED THE DESIGN CARRYING CAPACITY OF THE SUPPORTING
MEMBER.
3. PENDANT HUNG LIGHTING FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE
STRUCTURE ABOVE USING No. 9 GAGE (2.91 mm) WIRE WITHOUT USING THE CEILING
SUSPENSION SYSTEM FOR DIRECT SUPPORT.
4. RIGID CONDUIT IS NOT RECOMMENDED FOR ATTACHMENT OF FIXTURES.
5. LIGHTING FIXTURES WEIGHING LESS THAN 56 lb. SHALL HAVE, IN ADDITION TO THE
REQUIREMENTS OUTLINED ABOVE, TWO (2) No. 12 GAGE HANGERS CONNECTED FROM THE
FIXTURE HOUSING TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK.
6. LIGHTING FIXTURES WEIGHING 56 lb. OR MORE SHALL BE SUPPORTED DIRECTLY FROM THE
STRUCTURE ABOVE BY APPROVED HANGERS.
D. SERVICES WITHIN THE CEILING:
1. THE SUSPENDED CEILING SHALL NOT BE USED TO SUPPORT DUCTWORK, PLUMBING, ETC.
THESE ITEMS SHOULD BE ATTACHED TO THE STRUCTURE ABOVE EXCEPT WHEN SUCH
UNITS WERE SPECIALLY DESIGNED FOR THIS APPLICATION, AS IN THE CASE OF
INTEGRATED CEILING SYSTEMS.
2. CEILING MOUNTED AIR TERMINALS, OR SERVICES WEIGHING LESS THAN 20 lb. SHALL BE
POSITIVELY ATTACHED TO THE SUSPENSION SYSTEM UNLESS DEFLECTION MINIMUMS ARE
EXCEEDED.
E. PARTITION APPLICATION TO SUSPENDED CEILINGS:
1. WHERE NON-BEARING PARTITIONS ARE ATTACHED TO CEILING SUSPENSION SYSTEMS, THE
LATERAL FORCE REACTION TRANSMITTED MUST FALL WITHIN THE DESIGN LIMITATION OF
THE SUSPENSION SYSTEM OR SUPPLEMENTARY BRACING MUST BE PROVIDED.
GENERAL CEILING NOTES:
REFER TO LIGHTING PLAN FOR FIXTURE TYPES AND SWITCHING LOCATIONS
ACT: INSTALL, WHERE NOTED, ARMSTRONG CEILING 24" x 24" GRID CANYON WITH TEGULAR EDGE
WITH PRELUDE ML EXPOSED TEE SUSPENSION SYSTEM
AM10/23/20
ACOUSTICAL CEILING TILE
Existing Slab
2x6 WOOD STUD FRAMING
R-15 BATT INSULATION
5/8" TYPE 'X' GYPSUM WALL
BOARD EACH SIDE
EXISTING ROOF STRUCTURE
ALL WALL PENETRATION TO
HAVE FIRE CAULK INSTALLED
2x4 WOOD STUD FRAMING
5/8" GYPSUM WALL BOARD
EACH SIDE
ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE
EXTEND STUDS TO
UNDERSIDE OF ROOF JOISTS
EXISTING ROOF STRUCTURE
Existing Slab Existing Slab
ACOUSTICAL CEILING TILE
5/8" GYPSUM WALL BOARDEACH SIDEFURRING STRIPS EACH SIDE9'-4"11'-11 3/8"9'-4"11'-11 3/8"8'-0"9'-4"MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO.
JOB NO.
SCOPE DOCUMENT
THE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE
MAJOR ARCHITECTURAL ELEMENTS AND
THE TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL
SYSTEMS. AS SCOPE DOCUMENTS, THE
DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK THAT
IS REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT
DOCUMENTS. ON THE BASIS OF THE
GENERAL SCOPE INDICATED OR
DESCRIBED, THE TRADE CONTRACTORS
SHALL FURNISH ALL ITEMS REQUIRED
FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY
ONLY TO THE DOCUMENT TO WHICH
THEY ARE AFFIXED AND WE EXPRESSLY
DISCLAIM ANY RESPONSIBILITY FOR ALL
OTHER PLANS, SPECIFICATIONS,
ESTIMATES, REPORTS, OR OTHER
DOCUMENTS OR INSTRUMENTS
RELATING TO OR INTENDED TO BE USED
FOR ANY PART OR PARTS OF THE
PROJECT.
COPYRIGHT 2020 HOLDER DESIGN, INC.
REVISIONS
A20-020 SHEET DESCRIPTION: -24 South 5th Street
Terre Haute, Indiana
47807
ph. 812.235.1300
www.holderdesign.net
HOLDER DESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:WALL SECTIONSAMA3.0
A3.0 SCALE: 3/4" = 1'-0"
1 FIRE WALL SECTION
A3.0 SCALE: 3/4" = 1'-0"
2 TYP. PARTITION SECTION
A3.0 SCALE: 3/4" = 1'-0"
3 BLOCK WALL SECTION
10/23/20
EXISTING FIRE WALL
ELECTRICAL PANEL
UNIT 116
NOT IN SCOPE
1,215 SF
NON-SPRINKLERED
UTILITIES
108
UNIT 118
1,172 SF
NON-SPRINKLERED
+11'-11 3/8"
RAFTERS
ELECTRICAL PANEL
LOBBY
100
RECEPTION
101
OFFICE
102
HALL
103
OFFICE
104
HALL
105
CONFERENCE
106
STORAGE
107
OFFICE
OFFICE
STORAGE
UNIT 120
NOT IN SCOPE
2,487 SF
NON-SPRINKLERED
LOBBY
OPEN OFFICEFEC
EXIT
REMOTE HEAD REQUIRED
AT ALL EXITS
EXIT
REMOTE HEAD REQUIRED
AT ALL EXITS
EXIT
REMOTE HEAD REQUIRED
AT ALL EXITS
EXIT
REMOTE HEAD REQUIRED
AT ALL EXITS
TRAVEL DISTANCE: 44'-7"TRAVEL DISTANCE: 60'-4"TRAV
EL DIS
T
A
N
C
E:
1
7'
-
1
"TRAVEL DI
STANCE: 63
'
-8"
TRAVEL DISTANCE
:
34'-9"
SD SD
SD
SD
SD
SD
MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO.
JOB NO.
SCOPE DOCUMENT
THE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE
MAJOR ARCHITECTURAL ELEMENTS AND
THE TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL
SYSTEMS. AS SCOPE DOCUMENTS, THE
DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK THAT
IS REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT
DOCUMENTS. ON THE BASIS OF THE
GENERAL SCOPE INDICATED OR
DESCRIBED, THE TRADE CONTRACTORS
SHALL FURNISH ALL ITEMS REQUIRED
FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY
ONLY TO THE DOCUMENT TO WHICH
THEY ARE AFFIXED AND WE EXPRESSLY
DISCLAIM ANY RESPONSIBILITY FOR ALL
OTHER PLANS, SPECIFICATIONS,
ESTIMATES, REPORTS, OR OTHER
DOCUMENTS OR INSTRUMENTS
RELATING TO OR INTENDED TO BE USED
FOR ANY PART OR PARTS OF THE
PROJECT.
COPYRIGHT 2020 HOLDER DESIGN, INC.
REVISIONS
A20-020 SHEET DESCRIPTION: -24 South 5th Street
Terre Haute, Indiana
47807
ph. 812.235.1300
www.holderdesign.net
HOLDERDESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:LIFE SAFETY PLANAMA4.0
A4.0 SCALE: 1/4" = 1'-0"
1 LIFE SAFETY PLAN
N
KEY:
CODE ANALYSIS
PROPOSED USE
NEW FIT-OUT: 1,172 SF
EXISTING SPACE: 2,678 SF
TOTAL TENANT SPACE: 3,850 SF
TYPE V-B
B - BUSINSESS
AREA
CONSTRUCTION TYPE
OCCUPANCY CLASSIFICATION
EXIT SIGN
SMOKE DETECTORS
FIRE EXTINGUISHER
ALL NEW FIRE ALARM DEVICES WILL BE SPECIFIED THROUGHOUT THE ENTIRE STRUCTURE
FIRE ALARM & LIFE SAFETY NOTES:
SD
FEC
OCCUPANT LOAD PER 1004.1.2 EXERCISE 100 GROSS: 39 OCCUPANTS
1 EXIT REQUIRED
4 EXITS ARE PROVIDED OK
> 30 OCCUPANTS: 75'-0" ALLOWED
MAXIMUM TRAVEL DISTANCE: 63'-8" OK
EXITING
TRAVEL DISTANCE PER 1014.3
EXIT ILLUMINATION - REMOTE HEADS REQUIRED AT ALL EXITS
# OF EXITS PER 1015.1
10/23/20
ELECTRICAL PANEL
UTILITIES
108
UNIT 118
1,172 SF
NON-SPRINKLERED
LOBBY
100
RECEPTION
101
OFFICE
102
HALL
103
OFFICE
104
HALL
105
CONFERENCE
106
STORAGE
107
R RR
R
RR R
R
R
R
R
R
R RR
R
R
R
R
R
R
R
R
R R R
R
R
R
R
$$4 $3
$4$$$3$3$3
$3
$3
$3 $4 $3ELECTRICAL PANEL
UTILITIES
108
UNIT 118
1,172 SF
NON-SPRINKLERED
LOBBY
100
RECEPTION
101
OFFICE
102
HALL
103
OFFICE
104
HALL
105
CONFERENCE
106
STORAGE
107
6'-0" AFF
MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO.
JOB NO.
SCOPE DOCUMENT
THE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE
MAJOR ARCHITECTURAL ELEMENTS AND
THE TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL
SYSTEMS. AS SCOPE DOCUMENTS, THE
DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK THAT
IS REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT
DOCUMENTS. ON THE BASIS OF THE
GENERAL SCOPE INDICATED OR
DESCRIBED, THE TRADE CONTRACTORS
SHALL FURNISH ALL ITEMS REQUIRED
FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY
ONLY TO THE DOCUMENT TO WHICH
THEY ARE AFFIXED AND WE EXPRESSLY
DISCLAIM ANY RESPONSIBILITY FOR ALL
OTHER PLANS, SPECIFICATIONS,
ESTIMATES, REPORTS, OR OTHER
DOCUMENTS OR INSTRUMENTS
RELATING TO OR INTENDED TO BE USED
FOR ANY PART OR PARTS OF THE
PROJECT.
COPYRIGHT 2020 HOLDER DESIGN, INC.
REVISIONS
A20-020 SHEET DESCRIPTION: -24 South 5th Street
Terre Haute, Indiana
47807
ph. 812.235.1300
www.holderdesign.net
HOLDERDESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:POWER, DATA, & SWITCHING PLANSE1.0
E1.0 SCALE: 1/4" = 1'-0"
1 SWITCHING PLAN
N AMNOTES:
ELECTRICAL, DATA, & AUDIO NOTES:
HOME OWNER SHALL DO A WALK-THRU WITH RELEVANT INSTALLERS TO VERIFY THE
EXACT LOCATION FOR OUTLETS, LIGHTS, SWITCHES, CABLE, DATA, PHONE, AUDIO,
ETC.
ELECTRICAL NOTES:
ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS AND GARAGES SHALL BE
G.F.I. ORG.F.I.C. PER NATIONAL ELECTRICAL CODE REQUIREMENTS.
PROVIDE ONE SMOKE DETECTOR IN EACH ROOM AND ONE IN EACH CORRIDOR
ACCESSING BEDROOMS. SMOKE DETECTORS TO BE BATTERY OPERATED.
CIRCUITS SHALL BE VERIFIED WITH HOME OWNER PRIOR TO WIRE INSTALLATION.
FINAL SWITCHES FOR TIMERS AND DIMMERS SHALL BE VERIFIED WITH HOME
OWNER.
FIXTURES TO BE SELECTED BY HOME OWNER.
AUDIO:
LOCATE SPEAKERS AND AUDIO CONTROLS AS INDICATED IN THE PLAN; RUN CIRCUIT
OF SPEAKER WIRING TO AUDIO HOME PANEL SPECIFIED BY FLOOR; IF APPLICABLE.
AUDIO SPEAKERS TO BE APPROVED BY RENTER OF SPACE; ALL AV LABOR AND
MATERIALS TO BE PERFORMED BY RENTER OF SPACE
LOCATE JACKS AS INDICATED IN THE PLAN; INSTALL DATA / CABLE PANEL SIMILAR
TO "ON Q". SYSTEM TO BE APPROVED BY HOME OWNER.
DATA / CABLE:
LOCATE SECURITY PANELS AS INDICATED IN THE PLAN; SYSTEM TO BE APPROVED
BY HOME OWNER. ALL DATA / CABLE LABOR AND MATERIALS TO BE PERFORMED BY
RENTER OF SPACE.
E1.0 SCALE: 1/4" = 1'-0"
2 POWER + DATA PLAN
N
10/23/20
ELECTRICAL PANEL
UTILITIES
108
UNIT 118
1,172 SF
NON-SPRINKLERED
LOBBY
100
RECEPTION
101
OFFICE
102
HALL
103
OFFICE
104
HALL
105
CONFERENCE
106
STORAGE
107
EXISTING RTU EXISTING SUPPLYEXISTING SUPPLY EXISTING SUPPLY EXISTING RETURN EXISTING RETURN EXISTING RETURNNOTE: HVAC IS
SUPPLIED FOR THIS
AREA BY UNIT 120
24x24 RETURN
24x24 RETURN 24x24 RETURN
24x24 RETURN
24x24 RETURN
MLHPLOT SCALE:DATE:CHECKED BY:DRAWN BY:SHEET NO.
JOB NO.
SCOPE DOCUMENT
THE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OF
ARCHITECTURAL DESIGN CONCEPT, THE
DIMENSIONS OF THE BUILDING, THE
MAJOR ARCHITECTURAL ELEMENTS AND
THE TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL
SYSTEMS. AS SCOPE DOCUMENTS, THE
DRAWINGS DO NOT NECESSARILY
INDICATE OR DESCRIBE ALL WORK THAT
IS REQUIRED FOR FULL PERFORMANCE
AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT
DOCUMENTS. ON THE BASIS OF THE
GENERAL SCOPE INDICATED OR
DESCRIBED, THE TRADE CONTRACTORS
SHALL FURNISH ALL ITEMS REQUIRED
FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK.AS NOTED09.11.2020THE SEAL(S) AND SIGNATURE(S) APPLY
ONLY TO THE DOCUMENT TO WHICH
THEY ARE AFFIXED AND WE EXPRESSLY
DISCLAIM ANY RESPONSIBILITY FOR ALL
OTHER PLANS, SPECIFICATIONS,
ESTIMATES, REPORTS, OR OTHER
DOCUMENTS OR INSTRUMENTS
RELATING TO OR INTENDED TO BE USED
FOR ANY PART OR PARTS OF THE
PROJECT.
COPYRIGHT 2020 HOLDER DESIGN, INC.
REVISIONS
A20-020 SHEET DESCRIPTION: -24 South 5th Street
Terre Haute, Indiana
47807
ph. 812.235.1300
www.holderdesign.net
HOLDERDESIGN, INC.Premier Family ChiropracticTENANT EXPANSIONCARMEL, INDIANA INSTRUCTIONS FOR:HVAC PLANM1.0
E1.0 SCALE: 1/4" = 1'-0"
1 SWITCHING PLAN
N AMNOTES:
10/23/20